1
|
Zoratto S, Heuser T, Friedbacher G, Pletzenauer R, Graninger M, Marchetti-Deschmann M, Weiss VU. Adeno-Associated Virus-like Particles' Response to pH Changes as Revealed by nES-DMA. Viruses 2023; 15:1361. [PMID: 37376661 DOI: 10.3390/v15061361] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/29/2023] [Accepted: 06/08/2023] [Indexed: 06/29/2023] Open
Abstract
Gas-phase electrophoresis on a nano-Electrospray Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) separates single-charged, native analytes according to the surface-dry particle size. A volatile electrolyte, often ammonium acetate, is a prerequisite for electrospraying. Over the years, nES GEMMA has demonstrated its unique capability to investigate (bio-)nanoparticle containing samples in respect to composition, analyte size, size distribution, and particle numbers. Virus-like particles (VLPs), being non-infectious vectors, are often employed for gene therapy applications. Focusing on adeno-associated virus 8 (AAV8) based VLPs, we investigated the response of these bionanoparticles to pH changes via nES GEMMA as ammonium acetate is known to exhibit these changes upon electrospraying. Indeed, slight yet significant differences in VLP diameters in relation to pH changes are found between empty and DNA-cargo-filled assemblies. Additionally, filled VLPs exhibit aggregation in dependence on the applied electrolyte's pH, as corroborated by atomic force microscopy. In contrast, cryogenic transmission electron microscopy did not relate to changes in the overall particle size but in the substantial particle's shape based on cargo conditions. Overall, we conclude that for VLP characterization, the pH of the applied electrolyte solution has to be closely monitored, as variations in pH might account for drastic changes in particles and VLP behavior. Likewise, extrapolation of VLP behavior from empty to filled particles has to be carried out with caution.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Thomas Heuser
- Electron Microscopy Facility, Vienna BioCenter Core Facilities GmbH, A-1030 Vienna, Austria
| | - Gernot Friedbacher
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| | - Robert Pletzenauer
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria
| | - Michael Graninger
- Pharmaceutical Sciences, Baxalta Innovations GmbH (Part of Takeda), A-1221 Vienna, Austria
| | | | - Victor U Weiss
- Institute of Chemical Technologies and Analytics, TU Wien, A-1060 Vienna, Austria
| |
Collapse
|
2
|
Zoratto S, Weiss VU, Friedbacher G, Buengener C, Pletzenauer R, Foettinger-Vacha A, Graninger M, Allmaier G. Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy. ACS OMEGA 2021; 6:16428-16437. [PMID: 34235314 PMCID: PMC8246466 DOI: 10.1021/acsomega.1c01443] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/27/2021] [Indexed: 05/30/2023]
Abstract
Adeno-associated virus (AAV)-based virus-like particles (VLPs) are thriving vectors of choice in the biopharmaceutical field of gene therapy. Here, a method to investigate purified AAV serotype 8 (AAV8) batches via a nanoelectrospray gas-phase mobility molecular analyzer (nES GEMMA), also known as an nES differential mobility analyzer, is presented. Indeed, due to AAV's double-digit nanometer scale, nES GEMMA is an excellently suited technique to determine the surface-dry particle size termed electrophoretic mobility diameter of such VLPs in their native state at atmospheric pressure and with particle-number-based detection. Moreover, asymmetric flow field-flow fractionation (AF4, also known as AFFFF) and atomic force microscopy (AFM) techniques were employed as orthogonal techniques for VLP characterization. In addition, AF4 was implemented to size-separate as well as to enrich and collect fractions of AAV8 VLPs after inducing analyte aggregation in the liquid phase. Bionanoparticle aggregation was achieved by a combination of heat and shear stress. These fractions were later analyzed with nES GEMMA (in the gas phase) and AFM (on a solid surface). Both techniques confirm the presence of dimers, trimers, and putative VLP oligomers. Last, AFM reveals even larger AAV8 VLP aggregates, which were not detectable by nES GEMMA because their heterogeneity combined with low abundance was below the limit of detection of the instrument. Hence, the combination of the employed orthogonal sizing methods with the separation technique AF4 allow a comprehensive characterization of AAV8 VLPs applied as vectors.
Collapse
Affiliation(s)
- Samuele Zoratto
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Victor U. Weiss
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Gernot Friedbacher
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Carsten Buengener
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Robert Pletzenauer
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Alexandra Foettinger-Vacha
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| | - Michael Graninger
- Pharmaceutical
Sciences, Baxalta Innovations (part of Takeda), Vienna A-1221, Austria
| | - Guenter Allmaier
- Institute
of Chemical Technologies and Analytics, TU Wien (Vienna University of Technology), Vienna A-1060, Austria
| |
Collapse
|
3
|
Mi X, Fuks P, Wang SC, Winters MA, Carta G. Protein Adsorption on Core-shell Particles: Comparison of Capto™ Core 400 and 700 Resins. J Chromatogr A 2021; 1651:462314. [PMID: 34144396 DOI: 10.1016/j.chroma.2021.462314] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 05/26/2021] [Accepted: 05/29/2021] [Indexed: 01/15/2023]
Abstract
Structural and functional characteristics of the two core-shell resins Capto™ Core 400 and 700, which are useful for the flow-through purification of bioparticles such as viruses, viral vectors, and vaccines, are compared using bovine serum albumin (BSA) and thyroglobulin (Tg) as models for small and large protein contaminants. Both resins are agarose-based and contain an adsorbing core surrounded by an inert shell. Although shell thicknesses are comparable (3.6 and 4.2 µm for Capto Core 400 and 700, respectively), the two resins differ substantially in pore size (pore radii of 19 and 50 nm, respectively). Because of the smaller pores and higher surface area, the BSA binding capacity of Capto Core 400 is approximately double that of Capto Core 700. However, for the much larger Tg, the attainable capacity is substantially larger for Capto Core 700. Mass transfer in both resins is affected by diffusional resistances through the shell and within the adsorbing core. For BSA, core and shell effective pore diffusivities are about 0.25 × 10-7 and 0.6 × 10-7 cm2/s, respectively, for Capto Core 400, and about 1.6 × 10-7 and 2.6 × 10-7 cm2/s, respectively, for Capto Core 700. These values decrease dramatically for Tg to 0.022 × 10-7 and 0.088 × 10-7 cm2/s and to 0.13 × 10-7 and 0.59 × 10-7 cm2/s for Capto Core 400 and 700, respectively. Adsorbed Tg further hinders diffusion of BSA in both resins. Column measurements show that, despite the higher static capacity of Capto Core 400 for BSA, the dynamic binding capacity is greater for Capto Core 700 as a result of its faster kinetics. However, some of this advantage is lost if the feed is a mixture of BSA and Tg since, in this case, Tg binding leads to greater diffusional hindrance for BSA.
Collapse
Affiliation(s)
- Xue Mi
- Department of Chemical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Preston Fuks
- Department of Chemical Engineering, University of Virginia, Charlottesville, VA, USA
| | - Sheng-Ching Wang
- Vaccine Process Research and Development, Merck & Co., Inc., West Point, PA, USA
| | - Michael A Winters
- Vaccine Process Research and Development, Merck & Co., Inc., West Point, PA, USA
| | - Giorgio Carta
- Department of Chemical Engineering, University of Virginia, Charlottesville, VA, USA.
| |
Collapse
|
4
|
Real-Hohn A, Groznica M, Löffler N, Blaas D, Kowalski H. nanoDSF: In vitro Label-Free Method to Monitor Picornavirus Uncoating and Test Compounds Affecting Particle Stability. Front Microbiol 2020; 11:1442. [PMID: 32676065 PMCID: PMC7333345 DOI: 10.3389/fmicb.2020.01442] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 06/04/2020] [Indexed: 12/30/2022] Open
Abstract
Thermal shift assays measure the stability of macromolecules and macromolecular assemblies as a function of temperature. The Particle Stability Thermal Release Assay (PaSTRy) of picornaviruses is based on probes becoming strongly fluorescent upon binding to hydrophobic patches of the protein capsid (e.g., SYPRO Orange) or to the viral RNA genome (e.g., SYTO-82) that become exposed upon heating virus particles. PaSTRy has been exploited for studying the stability of viral mutants, viral uncoating, and the effect of capsid-stabilizing compounds. While the results were usually robust, the thermal shift assay with SYPRO Orange is sensitive to surfactants and EDTA and failed at least to correctly report the effect of excipients on an inactivated poliovirus 3 vaccine. Furthermore, interactions between the probe and capsid-binding antivirals as well as mutual competition for binding sites cannot be excluded. To overcome these caveats, we assessed differential scanning fluorimetry with a nanoDSF device as a label-free alternative. NanoDSF monitors the changes in the intrinsic tryptophan fluorescence (ITF) resulting from alterations of the 3D-structure of proteins as a function of the temperature. Using rhinovirus A2 as a model, we demonstrate that nanoDFS is well suited for recording the temperature-dependence of conformational changes associated with viral uncoating with minute amounts of sample. We compare it with orthogonal methods and correlate the increase in viral RNA exposure with PaSTRy measurements. Importantly, nanoDSF correctly identified the thermal stabilization of RV-A2 by pleconaril, a prototypic pocket-binding antiviral compound. NanoDFS is thus a label-free, high throughput-customizable, attractive alternative for the discovery of capsid-binding compounds impacting on viral stability.
Collapse
Affiliation(s)
- Antonio Real-Hohn
- Center for Medical Biochemistry, Max Perutz Labs, Vienna Biocenter, Medical University of Vienna, Vienna, Austria
| | | | | | | | - Heinrich Kowalski
- Center for Medical Biochemistry, Max Perutz Labs, Vienna Biocenter, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
5
|
Farsang E, Guillarme D, Veuthey JL, Beck A, Lauber M, Schmudlach A, Fekete S. Coupling non-denaturing chromatography to mass spectrometry for the characterization of monoclonal antibodies and related products. J Pharm Biomed Anal 2020; 185:113207. [DOI: 10.1016/j.jpba.2020.113207] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 02/21/2020] [Accepted: 02/22/2020] [Indexed: 01/31/2023]
|
6
|
Joshi PU, Turpeinen DG, Weiss M, Escalante-Corbin G, Schroeder M, Heldt CL. Tie line framework to optimize non-enveloped virus recovery in aqueous two-phase systems. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1126-1127:121744. [DOI: 10.1016/j.jchromb.2019.121744] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 07/18/2019] [Accepted: 08/02/2019] [Indexed: 01/01/2023]
|