1
|
Cortolillo NS, Guerra A, Murphy E, Hoel AW, Eskandari MK, Tomita TM. Outcomes of the Gore ® Excluder ® Iliac Branch Endoprosthesis Using Self Expanding or Balloon-Expandable Stent Grafts for the Internal Iliac Artery Component. J Endovasc Ther 2024; 31:1227-1233. [PMID: 37148192 DOI: 10.1177/15266028231169177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
OBJECTIVE The GORE® EXCLUDER® Iliac Branch Endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Arizona) was developed to be used in combination with a self-expanding stent graft (SESG) for the internal iliac artery (IIA) bridging stent. Balloon-expandable stent grafts (BESGs) are an alternative for the IIA, offering advantages in sizing, device tracking, precision, and lower profile delivery. We compared the performance of SESG and BESG when used as the IIA bridging stent in patients undergoing EVAR with IBE. METHODS This is a retrospective review of consecutive patients who underwent EVAR with IBE implantation at a single center from October 2016 to May 2021. Anatomic and procedural characteristics were recorded via chart review and computed tomography (CT) postprocessing software (Vitrea® v7.14). Devices were assigned to SESG vs. BESG groups based on the type of device landing into the most distal IIA segment. Analysis was performed per device to account for patients undergoing bilateral IBE. The primary endpoint was IIA patency, and secondary endpoint was IBE-related endoleak. RESULTS During the study period, 48 IBE devices were implanted in 41 patients (mean age 71.1 years). All IBE devices were implanted in conjunction with an infrarenal endograft. There were 24 devices in each of the self-expanding internal iliac component (SE-IIC) and balloon-expandable internal iliac component (BE-IIC) groups. The BE-IIC group had smaller diameter IIA target vessels (11.6±2.0 mm vs. 8.4±1.7 mm, p<0.001). Mean follow-up was 525 days. Loss of IIA patency occurred in 2 SESG devices (8.33%) at 73 and 180 days postprocedure, and in zero BESG devices, however, this difference was not statistically significant (p=0.16). There was 1 IBE-related endoleak requiring reintervention during the study period. A BESG device required reintervention due to Type 3 endoleak at 284 days. CONCLUSIONS There were no significant differences in outcomes between SESG and BESG when used for the IIA bridging stent in EVAR with IBE. The BESGs were associated with using 2 IIA bridging stents and were more often deployed in smaller IIA target arteries. Retrospective study design and small sample size may limit the generalizability of our findings. CLINICAL IMPACT This series compares postoperative and midterm outcomes of self expanding stent grafts and balloon expandable stent grafts (BESG) when used as the internal iliac stent graft as part of a Gore® Excluder® Iliac Branch Endoprosthesis (IBE). With similar outcomes between the two stent-grafts, our series suggests that some of the advantages of BESG, device sizing, tracking, deployment, and profile, may be able to be leveraged without impacting the mid-term performance of the IBE.
Collapse
Affiliation(s)
- Nicholas S Cortolillo
- Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Andres Guerra
- Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Eric Murphy
- Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Andrew W Hoel
- Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Mark K Eskandari
- Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Tadaki M Tomita
- Division of Vascular Surgery, Department of Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| |
Collapse
|
2
|
Kostiuk V, Rodriguez PP, Aboian E, Kuwayama DP, Guzman RJ, Ochoa Chaar CI. Ruptured Complex Aortoiliac Aneurysm in an Elderly Patient With a Kidney Transplant Presenting With Sciatica. Vasc Endovascular Surg 2024:15385744241296220. [PMID: 39438778 DOI: 10.1177/15385744241296220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2024]
Abstract
Background: Common iliac artery aneurysms are uncommon, with an estimated incidence of less than 0.01% in adults and accounting for only 1% of all intra-abdominal aneurysms. While the risk of rupture is approximately 5%, it increases significantly to 29% once the aneurysm reaches 4 cm. Similarly to abdominal aortic aneurysms, common iliac artery aneurysms often develop silently, remaining asymptomatic in about 70% of cases. This report describes the treatment of a patient with a kidney transplant who underwent endovascular repair of a ruptured left common iliac artery aneurysm with a concomitant abdominal aortic aneurysm and a focal aneurysm of the right renal artery origin. Case Description: A 78-year-old male patient with a kidney transplant presented with left sciatica symptoms and was found to have a contained rupture of a 10 x 7 cm left common iliac artery aneurysm with a concomitant 8 cm abdominal aortic aneurysm and a focal 1.8 cm aneurysm of the right renal artery origin. He underwent an endovascular aneurysm repair with an Aorto-Uni-iliac stent graft and a concomitant right-to-left femoral-femoral bypass using 8 mm ringed PTFE graft and ligation of left external iliac artery to prevent retrograde flow into the left common iliac artery aneurysm. At 3-year follow-up, patient remains stable with a functioning kidney transplant and excluded aneurysms with no evidence of endoleak. Conclusion: This report describes the endovascular repair of a ruptured left common iliac artery aneurysm conducted under local anesthesia in a patient with a renal transplant and complex aneurysm anatomy. The calcification pattern observed on a non-contrast CT scan was effectively used for surgical planning, leading to a successful aneurysm repair while preserving kidney transplant function.
Collapse
Affiliation(s)
| | - Paula Pinto Rodriguez
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
| | - Edouard Aboian
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
| | - David P Kuwayama
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
| | - Raul J Guzman
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
| | - Cassius Iyad Ochoa Chaar
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale University School of Medicine, New Haven, CT, USA
| |
Collapse
|
3
|
Bresler AM, Panthofer A, Kuramochi Y, Olson SL, Eagleton M, Schneider DB, Lyden SP, Blackwelder WC, Uhl CF, Bischoff MS, Matsumura JS, Böckler D. Image-based assessment of aortoiliac aneurysm anatomical characteristics in patients from the global iliac branch study. Langenbecks Arch Surg 2024; 409:135. [PMID: 38649506 PMCID: PMC11035386 DOI: 10.1007/s00423-024-03326-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 04/15/2024] [Indexed: 04/25/2024]
Abstract
OBJECTIVE Endovascular repair is the preferred treatment for aortoiliac aneurysm, with preservation of at least one internal iliac artery recommended. This study aimed to assess pre-endovascular repair anatomical characteristics of aortoiliac aneurysm in patients from the Global Iliac Branch Study (GIBS, NCT05607277) to enhance selection criteria for iliac branch devices (IBD) and improve long-term outcomes. METHODS Pre-treatment CT scans of 297 GIBS patients undergoing endovascular aneurysm repair were analyzed. Measurements included total iliac artery length, common iliac artery length, tortuosity index, common iliac artery splay angle, internal iliac artery stenosis, calcification score, and diameters in the device's landing zone. Statistical tests assessed differences in anatomical measurements and IBD-mediated internal iliac artery preservation. RESULTS Left total iliac artery length was shorter than right (6.7 mm, P = .0019); right common iliac artery less tortuous (P = .0145). Males exhibited greater tortuosity in the left total iliac artery (P = .0475) and larger diameter in left internal iliac artery's landing zone (P = .0453). Preservation was more common on right (158 unilateral, 34 bilateral) than left (105 unilateral, 34 bilateral). There were 192 right-sided and 139 left-sided IBDs, with 318 IBDs in males and 13 in females. CONCLUSION This study provides comprehensive pre-treatment iliac anatomy analysis in patients undergoing endovascular repair with IBDs, highlighting differences between sides and sexes. These findings could refine patient selection for IBD placement, potentially enhancing outcomes in aortoiliac aneurysm treatment. However, the limited number of females in the study underscores the need for further research to generalize findings across genders.
Collapse
Affiliation(s)
- Alina-Marilena Bresler
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.
| | - Annalise Panthofer
- Department of Surgery, Division of Vascular Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Yuki Kuramochi
- Vascular Surgery Department, Heart Vascular Thoracic Surgery Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Sydney L Olson
- Department of Surgery, Division of Vascular Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Matthew Eagleton
- Department of Surgery, Division of Vascular and Endovascular Surgery, Massachusetts General Hospital, Boston, MA, USA
| | - Darren B Schneider
- Department of Surgery, Division of Vascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Sean P Lyden
- Vascular Surgery Department, Heart Vascular Thoracic Surgery Institute, Cleveland Clinic, Cleveland, OH, USA
| | - William C Blackwelder
- Department of Epidemiology and Public Health, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Christian F Uhl
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
- Department of Vascular Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - Moritz S Bischoff
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Jon S Matsumura
- Department of Surgery, Division of Vascular Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
- Department of Surgery, Division of Vascular Surgery, University of Colorado School of Medicine, Aurora, CO, USA
| | - Dittmar Böckler
- Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| |
Collapse
|
4
|
Zhou G, Ma H, Liu J, Sun X, Liu Y, Luan J, Li Y, Guo M. Quadruple fenestration aortic stent implantation combined with unilateral IBE and internal iliac artery stent implantation for complex abdominal aortic aneurysm: one case report. Front Cardiovasc Med 2023; 10:1276064. [PMID: 37881725 PMCID: PMC10595028 DOI: 10.3389/fcvm.2023.1276064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Accepted: 09/27/2023] [Indexed: 10/27/2023] Open
Abstract
An abdominal aortic aneurysm is a frequently encountered clinical condition, which necessitates prompt and effective remediation to avoid rupture. Surgeons must meticulously select an appropriate method of repair and assess the long-term surgical prognosis when dealing with patients with complex abdominal aortic aneurysms. In this case report, a 74-year-old man was hospitalized due to acute abdominal pain. Upon further examination, it was discovered that he was suffering from a complex abdominal aortic aneurysm. The thoracoabdominal aorta CTA showed that the aneurysm involved both renal arteries, the part below the kidney was severely twisted, the neck of the aneurysm was short, and it was accompanied by bilateral common iliac and internal iliac aneurysms, and there were considerable thrombus attached to the vessel wall. In this case, our team used 3D technology to simulate the spatial structure of the aneurysm and comprehensively evaluate the patient's condition. Ultimately, we decided to perform a quadruple fenestration aortic stent implantation and endovascular repair of aortic aneurysm, combined with right IBE and internal iliac artery stent implantation, right internal iliac artery reconstruction, and left internal iliac artery aneurysm embolization on this patient. This is an innovative surgical method. The operation was successful and the patient recovered well after the operation.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Yongxin Li
- Department of Vascular Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| | - Mingjin Guo
- Department of Vascular Surgery, The Affiliated Hospital of Qingdao University, Qingdao, China
| |
Collapse
|
5
|
de Athayde Soares R, Campos ABC, Figueiredo PWS, Vaz JHLG, Brienze CS, Waisberg J, Sacilotto R. The Importance of the Hypogastric Artery Preservation during Treatment for Aortoiliac Aneurysms: A Prospective Single-Center Study. Ann Vasc Surg 2023; 92:201-210. [PMID: 36690249 DOI: 10.1016/j.avsg.2022.12.095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 11/27/2022] [Accepted: 12/12/2022] [Indexed: 01/22/2023]
Abstract
BACKGROUND To determine the importance of the hypogastric artery for the outcomes of survival, endoleaks, reinterventions, buttock claudication (BC), and perioperative mortality rate (PMR) in patients with aortoiliac aneurysms (AIA) receiving endovascular or open surgical (OS) repair. METHODS This was a prospective consecutive cohort study of patients with AIA who underwent endovascular treatment or OS repair during the period of 2010-2021. Endovascular repair was performed with use of aortoiliac endoprosthesis associated with internal iliac artery (IIA) coil embolization and/or with iliac branch endoprosthesis (IBE) in order to preserve the IIA. The AIA OS repairs were performed with the artery ligation in order to exclude the IIA, or in some cases, the exclusion of the IIA was performed with an endosuture in the proximal stump of the artery. Three groups were identified in the postprocedural period: group 0 (no hypogastric arteries (HAs) preserved), group 1 (1 hypogastric artery preserved), and group 2 (2 hypogastric arteries preserved). RESULTS A total of 91 patients were submitted to OS or endovascular surgery. Regarding the HA patency, there were 17 patients in group 0, 45 patients in group 1, and 29 patients in group 2. There were 17 cases of bowel ischemia (BI) (94.1% in group 0, 5.9% in group 1, and no cases in group 2, P < 0.001) most of them in group 0, with statistical significance, 12 cases of BC (91.7% in group 0, 8.3% in group 1, and no cases in group 2, P < 0.001), most of them in group 0, with statistical significance. The perioperative mortality was 14.3%, 13 patients (9 patients - 52.9% group 0, 3 patients - 6.7% group 1, and 1 patient - 3.4% group 2, P < 0.001). The linear regression analysis for survival rates showed that BI [P = 0.026 to hazard ratio (HR) = 1.69], emergency aortoiliac repair (P < 0.001, HR = 8.86), and number of HAs (P < 0.001, HR = 5.46) in postoperative were related to poorer survival rates in both univariate and multivariate analysis. The linear regression analysis showed that the number of HAs (P < 0.001, HR = 3.61) in postoperative, emergency aortoiliac repair (P = 0.002, HR 3.233), and cardiac disease (P = 0.048, HR = 3.84) were related to BI. CONCLUSIONS In conclusion, the number of HA is crucial for adequate and safe outcomes after abdominal aortic aneurysm (AAA) repair. The main factors related to death were BI, emergency aortoiliac repair, and the number of HAs preserved. Moreover, the main factors related to BI were the number of HAs in postoperative, emergency aortoiliac repair, and cardiac disease.
Collapse
Affiliation(s)
- Rafael de Athayde Soares
- Division of Vascular and Endovascular Surgery, Hospital do Servidor Público Estadual de São Paulo, São Paulo, Brazil.
| | - Ana Beatriz Campelo Campos
- Division of Vascular and Endovascular Surgery, Hospital do Servidor Público Estadual de São Paulo, São Paulo, Brazil
| | | | | | - Carolina Sabadoto Brienze
- Division of Vascular and Endovascular Surgery, Hospital do Servidor Público Estadual de São Paulo, São Paulo, Brazil
| | - Jaques Waisberg
- Division of Vascular and Endovascular Surgery, Hospital do Servidor Público Estadual de São Paulo, São Paulo, Brazil
| | - Roberto Sacilotto
- Division of Vascular and Endovascular Surgery, Hospital do Servidor Público Estadual de São Paulo, São Paulo, Brazil
| |
Collapse
|
6
|
Schneider DB, Matsumura JS, Lee JT, Peterson BG, Chaer RA, Oderich GS. Five-year outcomes from a prospective, multicenter study of endovascular repair of iliac artery aneurysms using an iliac branch device. J Vasc Surg 2023; 77:122-128. [PMID: 35842202 DOI: 10.1016/j.jvs.2022.07.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 06/30/2022] [Accepted: 07/06/2022] [Indexed: 02/03/2023]
Abstract
OBJECTIVE We have reported the 5-year results of a pivotal prospective, multicenter study conducted in the United States of a specifically designed iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, AZ) for endovascular repair of aortoiliac aneurysms and common iliac artery aneurysms. METHODS A total of 63 patients (98.4% male; mean age, 70 years) with aortoiliac or common iliac artery aneurysms had undergone implantation of a single IBE device and a bifurcated aortoiliac stent graft. Patients with bilateral common iliac artery aneurysms (n = 22; 34.9%) had undergone either staged occlusion or surgical revascularization of the contralateral internal iliac artery before study enrollment. At 5 years, 36 of the 63 patients had completed the final study follow-up examinations, including clinical examinations (n = 35) and computed tomography (n = 32), with the results evaluated by an independent core laboratory and adverse events adjudicated by a clinical events committee. RESULTS At 5 years, freedom from all-cause mortality was 85.7% and freedom from aneurysm-related mortality was 100%. The nine deaths that had occurred (range, 132-1898 days) were adjudicated as unrelated to the aneurysm or procedure. Primary patency of the internal and external iliac artery IBE limbs was 95.1% and 100%, respectively. No patients had experienced new-onset buttock claudication on the IBE side or self-reported new-onset erectile dysfunction. The common iliac artery diameter on the IBE side was either unchanged or had decreased by ≥5 mm in 30 of the 31 patients (96.8%) with a baseline (1 month) and 5-year (range, 1641-2006 days) computed tomography scan available. Of the 31 evaluable patients, 9 (29.0%) had had an increase of ≥5 mm in the aortic diameter, 5 of whom had had a concurrent type II endoleak. No type I or type III endoleaks or device migration were identified by the core laboratory. Six patients had undergone eight secondary interventions, including five interventions for a type II endoleak. The freedom from secondary intervention was 90.5%. CONCLUSIONS The 5-year results of our prospective, multicenter study have confirmed the safety, efficacy, and durability of the IBE device for the treatment of aortoiliac and iliac artery aneurysms. The device effectively prevented common iliac artery aneurysm rupture, maintained the patency of the internal iliac artery, and avoided the complications associated with internal iliac artery sacrifice. Although common iliac artery aneurysm enlargement was rare, abdominal aortic enlargement was more common, suggesting that the outcomes of endovascular aneurysm repair might be different for patients with or without associated common iliac artery aneurysms.
Collapse
Affiliation(s)
- Darren B Schneider
- Division of Vascular Surgery and Endovascular Therapy, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA.
| | - Jon S Matsumura
- Division of Vascular Surgery, University of Wisconsin School of Medicine and Public Health, Madison, WI
| | - Jason T Lee
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA
| | - Brian G Peterson
- Heart and Vascular Institute, St. Luke's Hospital, Chesterfield, MO
| | - Rabih A Chaer
- Division of Vascular Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA
| | - Gustavo S Oderich
- Division of Cardiothoracic and Vascular Surgery, University of Texas Health Science Center, Houston, TX
| |
Collapse
|
7
|
Franklin RN, Timi JRR, Baumgardt G, Bortoluzzi C, Galego G, Oderich GS, Silveira PG. Laboratory "In-vitro" Evaluation of the Parallel Stent Graft Association for the Iliac Sandwich Technique. Cardiovasc Intervent Radiol 2022; 45:1377-1384. [PMID: 35778578 DOI: 10.1007/s00270-022-03182-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Accepted: 05/11/2022] [Indexed: 11/02/2022]
Abstract
OBJECTIVES The Iliac Sandwich is an off-label technique that uses parallel stent grafts to treat aortoiliac aneurysms. The purpose of this experimental study is to evaluate the conformability and juxtaposition of stent grafts combinations used in this technique through in-vitro mechanical evaluation, computed tomography (CT) analyses, and a controlled pulsatile flow system. METHODS The combinations of two Viabahn® ("V-V") or Viabahn® and Excluder® iliac extension ("V-E") were analysed using CT imaging with measurement of the gutter area by two independent analysts before and after balloon angioplasty. In a second phase, the parallel stent combinations were also evaluated using CT imaging after being implanted in the aortic aneurysm model with a pulsatile flow system with controlled temperature, viscosity, and density. RESULTS The "V-E" group had a better conformability when compared to the "V-V" group, ensuring smaller gutter areas (0.0064 cm2 ± 0.01 vs. 0.0228 cm2 ± 0.03, p < 0.001). Post dilatation with two non-compliant balloons resulted in enlargement of the gutter area (Area A, p 0.065; Area B, p 0.071). Conversely, post dilatation with a non-compliant balloon for the internal iliac component and a compliant balloon for the external iliac device reduced the gutter area (Area A, p 0.008; Area B, p 0.010). CONCLUSION The combination of Viabahn® and Excluder® iliac extension device ("V-E") had a smaller gutter area compared to two Viabahn® parallel stents for the Iliac Sandwich Technique. Post dilatation using a non-compliant balloon for the internal iliac device and a compliant balloon for the external iliac provided superior conformability and juxtaposition.
Collapse
Affiliation(s)
- Rafael Narciso Franklin
- Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil. .,Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil.
| | | | | | - Cristiano Bortoluzzi
- Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil
| | - Gilberto Galego
- Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil.,Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil
| | - Gustavo S Oderich
- The University of Texas Health Science Center at Houston, Houston, TX, USA
| | - Pierre Galvagni Silveira
- Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil.,Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil
| |
Collapse
|
8
|
Torrealba J, Panuccio G, Rohlffs F, Gandet T, Gronert C, Heidemann F, Tsilimparis N, Kölbel T. One-Year Results of ZBIS Iliac Branch Device With an Off-Label Connection Limb. J Endovasc Ther 2021; 29:402-408. [PMID: 34711093 DOI: 10.1177/15266028211054760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE The purpose of this article is to study 1-year results of Zenith branch iliac endovascular graft (ZBIS) with the off-label use of a 13 mm spiral Z limb to connect to the aortic main body. MATERIALS AND METHODS A retrospective review from 2015 to 2019 of all iliac branch devices (IBDs) was performed at 1 institution that were connected to an aortic main body with a 13 mm spiral Z limb and had at least 1-year follow-up with computed tomography (CT). Primary endpoints are freedom from ZBIS separation from the connection limb, endoleak (EL), or reintervention at 1 year. Secondary endpoints are primary and secondary ZBIS patency, presence of any EL, and aortic reinterventions. RESULTS Of 149 IBDs implanted in this period, 45 ZBIS in 35 patients were connected with a 13 mm limb and had a 1-year CT; 97% of patients had common iliac artery (CIA) aneurysms, 7% of patients had hypogastric artery (HA) aneurysms, and 30% of patients had bilateral ZBIS implantation. Technical success was 98%. In 84% of cases, the Advanta V12 was used as the HA mating stent; 56% of patients had an EL, mostly type II, which resolved spontaneously in 70% at 1 year, and 9% of ZBIS required reinterventions at 1 year (2 for thrombosis, 2 for type Ic EL from HA mating stent). One-year ZBIS primary patency and secondary patency were 96% and 100%, respectively. No EL was noted to be related to the 13 mm connection limb. No migration or separation of the devices occurred. CONCLUSIONS The use of 13 mm spiral Z limb to connect a ZBIS with the main body in our series yields a high technical success rate and good 12-month outcomes without device separation or migration.
Collapse
Affiliation(s)
- Jose Torrealba
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Giuseppe Panuccio
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Fiona Rohlffs
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Thomas Gandet
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Catharina Gronert
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Franziska Heidemann
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Nikolaos Tsilimparis
- Vascular Surgery Department, Hospital of the Ludwig-Maximilians-University (LMU), Munich, Germany
| | - Tilo Kölbel
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
9
|
DeRoo E, Harris D, Olson S, Panthofer A, Meadows W, Pauli T, Peterson B, Schneider D, Matsumura J. Conformability of the GORE EXCLUDER iliac branch endoprosthesis is associated with freedom from adverse iliac events. J Vasc Surg 2021; 74:1558-1564.e1. [PMID: 34082005 DOI: 10.1016/j.jvs.2021.05.026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Accepted: 05/01/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The GORE EXCLUDER iliac branch endoprosthesis (IBE; W.L. Gore & Associates, Flagstaff, Ariz) is designed to preserve internal iliac artery (IIA) patency during endovascular treatment of aneurysms involving the common iliac artery. The device is intended to conform to iliac tortuosity, which may decrease adverse iliac events (AIE). The objective of this study was to evaluate risk factors for AIE after IBE implantation. METHODS This was a post hoc analysis of the prospective, multicenter GORE 12-04 IBE pivotal trial. Patients with preoperative and postoperative axial imaging were included, with analysis based on each treated iliac system. An independent core laboratory performed all scan measurements, including iliac diameters, lengths, and tortuosity. Conformability was analyzed by the changes in tortuosity after IBE deployment, with less change indicating greater conformation. The end point was AIE, defined as ipsilateral radiographic or clinical complications. Critical nonconformation was defined as a threshold change in tortuosity associated with a significant increase in AIE. RESULTS We included 98 patients with 101 treated iliac systems. There were eight AIE (8%; six IIA component occlusions, one iliac branch component occlusion, and one EIA dissection requiring reintervention). Patients with AIE had smaller IIA diameters and less IBE conformability. After multivariable logistic regression analysis, an IIA diameter of less than 10 mm and a change in total iliac tortuosity beyond -15% were independently associated with AIE (odds ratio, 12 [interquartile range, 1.4-110] and odds ratio, 8.2 [interquartile range, 1.5-46], respectively), and the latter was used to define critical nonconformation. Critical nonconformation occurred in 11% of treated systems, and was associated with a high rate of AIE (36% vs 4%; P = .004). CONCLUSIONS Endograft conformation is a novel device property and technical outcome that, along with a larger IIA diameter, is associated with freedom from AIE after IBE deployment. An evaluation of these risk factors may better inform the management of patients with iliac aneurysmal disease. Further research on endograft conformation and patient outcomes is warranted, particularly for those with challenging anatomy undergoing complex procedures.
Collapse
Affiliation(s)
- Elise DeRoo
- Division of Vascular Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisc.
| | - Donald Harris
- Division of Vascular Surgery, Department of Surgery, University of Washington, Valley Medical Center, Seattle, Wash
| | - Sydney Olson
- Division of Vascular Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisc
| | - Annalise Panthofer
- Division of Vascular Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisc
| | - Wendy Meadows
- Division of Vascular Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisc
| | - Thomas Pauli
- Division of Vascular Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisc
| | - Brian Peterson
- St. Luke's Heart and Vascular Institute, St. Luke's Hospital, St. Louis, Mo
| | - Darren Schneider
- Division of Vascular and Endovascular Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pa
| | - Jon Matsumura
- Division of Vascular Surgery, Department of Surgery, University of Wisconsin School of Medicine and Public Health, Madison, Wisc
| |
Collapse
|
10
|
Abugov SA, Polyakov RS, Puretsky MV, Mardanyan GV, Pirkova AA, Kraynikov DA, Vartanyan EL, Charchyan ER. [Endovascular treatment of common iliac artery aneurisms]. Khirurgiia (Mosk) 2021:52-58. [PMID: 34032789 DOI: 10.17116/hirurgia202106252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To demonstrate endovascular management of common iliac artery aneurysms with iliac branch devices and to discuss some technical aspects of these interventions including bilateral procedures. MATERIAL AND METHODS Endovascular abdominal aortic aneurysm repair with concomitant implantation of iliac branch devices was performed in 9 patients at the Petrovsky National Research Center of Surgery for the period from January 2019 to December 2020. Mean age of patients was 64.8± years (min 52; max 72 years). Preoperative planning and morphometric analysis were based on CT data with a slice thickness of 1 mm. Angiographic reconstruction was made using Osirix 3D software (OsiriX Foundation, Geneva, Switzerland). Abdominal aortic aneurysm was combined with common iliac artery aneurysm in 7 patients (77.7%). Three (33.3%) patients had isolated common iliac artery aneurysm without significant abdominal aorta enlargement (Reber type I). Bilateral common iliac artery aneurysms were detected in 1 (11.1%) patient. All patients had iliac artery aneurysms over 4 cm. Iliac branch device implantation was accompanied by endovascular abdominal aneurysm repair in all patients. RESULTS Technical success rate was 100%. Six-month results were followed-up in 5 patients (55.5%), annual outcomes - in 2 patients (22.2%). Control examination consisted of a telephone interview, ultrasound of abdominal aorta, pelvic and lower limb arteries and computed tomography. All patients had no endoleaks, stent-graft thrombosis, as well as signs of ischemia of pelvic organs and lower extremities. Incidence of iliac artery aneurysm combined with abdominal aortic aneurysms is about 20%. Until recently, treatment of these patients was performed exclusively with covering of internal iliac artery. Improvement of technologies and development of iliac branch devices made it possible to preserve blood flow in internal iliac artery after endovascular management. This approach allowed avoiding of ischemic complications associated with embolization of internal iliac arteries.
Collapse
Affiliation(s)
- S A Abugov
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - R S Polyakov
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - M V Puretsky
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - G V Mardanyan
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - A A Pirkova
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - D A Kraynikov
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - E L Vartanyan
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| | - E R Charchyan
- Petrovsky Russian Scientific Center of Surgery, Moscow, Russia
| |
Collapse
|
11
|
Soares RDA, Matielo MF, Brochado FC, Palomo AT, Lourenço RA, Tanaka C, Sacilotto R. The outcomes of internal iliac artery preservation during endovascular or open surgery treatment for aortoiliac aneurysms. J Vasc Bras 2020; 19:e20200087. [PMID: 34211525 PMCID: PMC8218172 DOI: 10.1590/1677-5449.200087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background Internal iliac artery (IIA) preservation continues to be a challenge during open surgery or endovascular repair of abdominal aortoiliac aneurysm (AAIA). Objectives To determine the results in terms of survival and clinical outcomes in patients with aortoiliac aneurysms (AAIA) treated with endovascular (EV) or open surgical (OS) repair. Methods This was a retrospective consecutive cohort study of patients with AAIA who underwent EV or OS repair. Results Post-procedure hospitalization time and intensive care unit stay were both longer in the OS group than in the EV group (7.08 ± 3.5 days vs. 3.32 ± 2.3 days; p = 0.03; 3.35 ± 2.2 days vs. 1.2 ± 0.8 days; p = 0.02, respectively). There were two cases of bowel ischemia (4.7%; OS 8.3% and EV 3.2%; p = 0.48), two cases of buttock claudication (4.7%; OS 8.3% and EV 3.2%; p = 0.48), and one case of sexual dysfunction (2.3% OS), all of them in patients with bilateral occlusion of the internal iliac artery (five patients, 11.6%; p = 0.035). Overall survival at 720 days was 80.6% in the EV group and 66.7% in the OS group (p = 0.58). Conclusions In the present study, OS and EV repair of aortoiliac aneurysms had similar overall survival and outcomes. Preservation of at least one internal iliac artery is associated with good results and no further complications.
Collapse
Affiliation(s)
- Rafael de Athayde Soares
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| | - Marcelo Fernando Matielo
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| | - Francisco Cardoso Brochado
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| | - Amanda Thurler Palomo
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| | - Rodrigo Andrade Lourenço
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| | - Caroline Tanaka
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| | - Roberto Sacilotto
- Hospital do Servidor Público Estadual de São Paulo, Serviço de Cirurgia Vascular e Endovascular, São Paulo, SP, Brasil
| |
Collapse
|
12
|
Simonte G, Isernia G, Fino G, Centonza E, Parlani G, Lenti M, Cieri E. The Effect of Manufacturer's Instructions for Use Compliance on Cook ZBIS Iliac-Branched Endograft Long-Term Outcomes. Ann Vasc Surg 2020; 72:454-463. [PMID: 33160059 DOI: 10.1016/j.avsg.2020.09.055] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Revised: 09/17/2020] [Accepted: 09/17/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND Current guidelines indicate iliac-branched endografts (IBDs) as the ideal means to preserve pelvic perfusion during endovascular aortic repair. Because patient vascular anatomy represents the main limitation to extensive use of these devices, off-label application may be considered to expand the number of patients being treated. The aim of this study is to evaluate long-term outcomes obtained using the Cook ZBIS endograft in the treatment of aortoiliac aneurysms as per or outside manufacturer's instruction for use (IFU). METHODS Data from all patients who underwent IBD implant in a single center were reviewed. Study population was divided into two subgroups: Group I treated as per manufacturer's IFU and group II treated outside IFU. RESULTS During the study period (2008-2018), 119 patients were treated with 130 IBDs. Eighty-six patients were treated as per IFU (group I) and 44 outside IFU (group II). Overall technical success was 99.2%. Mean follow-up was of 63.5 ± 38.3 months for group I and 58.3 ± 35.9 months for group II (P = 0.45). Freedom from reintervention at ten years was 79.8% in group I and 69.6% in group II (P = 0.29). Freedom from IBD-related reintervention rate was 98.7% and 95.3% in groups I and II, respectively (P = 0.240). Iliac-branched module thrombosis occurred significantly more in patients treated outside IFU with 4 cases in group I (4.7%) and 10 cases in group II (22.7%), (P = 0.005). Cox regression analysis identified hypogastric artery aneurysm as the only independent predictor for both IBD thrombosis and hypogastric artery occlusion during follow-up. CONCLUSIONS When used by an experienced team, Cook IBDs are safe and effective in the treatment of aortoiliac aneurysms both inside and outside IFU. Anyway a lower target hypogastric patency rate should be expected when treating patients with hypogastric aneurysms.
Collapse
Affiliation(s)
- Gioele Simonte
- Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy.
| | - Giacomo Isernia
- Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Gianluigi Fino
- Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | | | - Gianbattista Parlani
- Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Massimo Lenti
- Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| | - Enrico Cieri
- Vascular Surgery Unit, S. Maria della Misericordia Hospital, University of Perugia, Perugia, Italy
| |
Collapse
|
13
|
Everything Flows, Nothing Stays Still. Eur J Vasc Endovasc Surg 2020; 61:227. [PMID: 32771285 PMCID: PMC7405874 DOI: 10.1016/j.ejvs.2020.06.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2020] [Accepted: 06/30/2020] [Indexed: 11/23/2022]
|
14
|
A 35 Year History of Stent Grafting, and How EVAR Conquered the World. Eur J Vasc Endovasc Surg 2020; 59:685-694. [PMID: 32307304 DOI: 10.1016/j.ejvs.2020.03.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2020] [Accepted: 03/13/2020] [Indexed: 12/23/2022]
|
15
|
Abstract
Most abdominal aortic aneurysms are treated with endovascular repair (EVAR) in current practice. EVAR has lower periprocedural mortality and morbidity than open surgical repair. Aneurysm neck morphology, iliac anatomy, and access vessel anatomy need careful assessment for the successful performance of EVAR. Regular and long-term follow-up with imaging is mandatory after EVAR, and patients who are less likely to comply are less favorable EVAR candidates. Endoleaks are the most frequent complication of EVAR. Most can be managed with transcatheter or endovascular means. Evolving technology and techniques are allowing more patients to be treated with EVAR with better long-term outcomes.
Collapse
Affiliation(s)
- Akshit Sharma
- Department of Cardiovascular Medicine, University of Kansas School of Medicine, 3901 Rainbow Boulevard, Delp 1001, Kansas City, KS 66160, USA
| | - Prince Sethi
- Department of Cardiovascular Medicine, University of Kansas School of Medicine, 3901 Rainbow Boulevard, Delp 1001, Kansas City, KS 66160, USA
| | - Kamal Gupta
- Department of Cardiovascular Medicine, University of Kansas School of Medicine, 3901 Rainbow Boulevard, Delp 1001, Kansas City, KS 66160, USA.
| |
Collapse
|
16
|
Drac P, Cerna M, Kocher M, Utikal P, Thomas RP. Is endovascular treatment of aorto-iliac aneurysms with simultaneous unilateral revascularization of internal iliac artery by branched iliac stentgraft sufficient? Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub 2020; 165:169-174. [PMID: 32116312 DOI: 10.5507/bp.2020.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Accepted: 01/28/2020] [Indexed: 11/23/2022] Open
Abstract
AIMS The coverage / occlusion of internal iliac artery (IIA) during endovascular treatment of aorto-iliac aneurysms (AIA) can be associated with risk of ischemic complications. To reduce these complications, unilateral or bilateral iliac branch device implantation (IBDI) has been reported. This study aims at evaluating the efficacy of simultaneous unilateral IBDI in the treatment of AIAs and comparing our results with literature. MATERIALS AND METHODS From March 2010 to December 2019, 27 patients (25 men, 2 women, range 54-84 years) were treated for aorto-iliac/isolated common iliac aneurysms with simultaneous unilateral revascularization of IIA and surgical / endovascular occlusion of contralateral IIA. 27 iliac-branched devices were implanted in 27 patients. The results including ischemic complications were evaluated and compared with literature. RESULTS The technical success was 100% with no perioperative mortality and morbidity of 3.7%. Primary internal iliac branch patency at a median follow-up of 52 months (range 1-118 months) was 96.42%. Secondary endoleak was observed in 6 patients (Type 1a [1], Type 1b [1], Type II [4]) and inflammatory complication in 1 patient. The incidence of buttock claudication one year after the procedure was 11.1%. Except for buttock claudication no other ischemic complications occurred. CONCLUSION Unilateral flow preservation in the IIA territory using IBDI is associated with a lesser, but a certain risk of ischemic complications. Bilateral IBDI with bilateral flow preservation of IIAs increases the complexity, procedure -/ fluoroscopy times, contrast agent volume and cost, however, may further reduce these ischemic complications.
Collapse
Affiliation(s)
- Petr Drac
- Department of Surgery II - Vascular and Transplantation Surgery, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - Marie Cerna
- Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - Martin Kocher
- Department of Radiology, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - Petr Utikal
- Department of Surgery II - Vascular and Transplantation Surgery, University Hospital Olomouc and Faculty of Medicine and Dentistry, Palacky University Olomouc, Czech Republic
| | - Rohit Philip Thomas
- Department of Diagnostic and Interventional Radiology, UKGM University Hospital Marburg, Philipps University, Marburg, Germany
| |
Collapse
|
17
|
Oliveira-Pinto J, Martins P, Mansilha A. Endovascular treatment of iliac aneurysmal disease with internal iliac artery preservation: a review of two different approaches. INT ANGIOL 2019; 38:494-501. [PMID: 31782280 DOI: 10.23736/s0392-9590.19.04215-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
INTRODUCTION The feasibility of endovascular aneurysm repair (EVAR) is often challenged by the concurrent presence of common iliac artery aneurysms, which prevent the attainment of a successful distal sealing. The present review aims to portray the safety and efficacy of two internal iliac artery (IIA) preservation strategies in the endovascular treatment of aortoiliac aneurysms: the iliac branch extension device (IBED) and the parallel graft - "sandwich" technique (PG-ST). EVIDENCE ACQUISITION A comprehensive literature review was conducted to identify publications on endovascular treatment of iliac aneurysmal disease using IBED or PG-ST. Primary endpoints were freedom from endoleak, IIA branch occlusion and secondary interventions. EVIDENCE SYNTHESIS Twenty-eight studies were selected for analysis describing a total of 1316 patients, 1169 in the IBED group and 147 in the PG-ST group. The technical success rates were akin for IBED and PG-ST (83.9-100% versus 81.3-100%). The defined primary endpoints were reported by fourteen articles. Freedom from endoleak, IIA branch occlusion and reintervention, at 6 months, were as follows: 82-100% versus 86%, 90-94% versus 88%, and 90-98% versus 87%, respectively for IBED and PG-ST. Later outcomes were only recorded in the IBED group, and freedom from endoleak, IIA branch occlusion and reintervention, at 9 years, were 83%, 81-90%, and 64-75%, respectively. CONCLUSIONS Both IBED and PG-ST have proven to be safe and valid approaches. However, while IBED has established as a durable procedure, mid-term data lacks on PGs performance and further studies are required to attest durability of the latter procedure.
Collapse
Affiliation(s)
- José Oliveira-Pinto
- Department of Surgery and Physiology, Faculty of Medicine of Porto, Porto, Portugal -
| | - Pedro Martins
- Department of Surgery and Physiology, Faculty of Medicine of Porto, Porto, Portugal
| | - Armando Mansilha
- Department of Surgery and Physiology, Faculty of Medicine of Porto, Porto, Portugal
| |
Collapse
|
18
|
Sayed T, Ahmed I, Rodway A, El Sakka K, Yusuf SW. Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience. Ann Vasc Dis 2019; 12:171-175. [PMID: 31275469 PMCID: PMC6600105 DOI: 10.3400/avd.oa.18-00101] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
Objectives: To evaluate the outcomes of the E-ventus BX balloon-expandable stent graft system (Jotec, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) and the iliac branch device (IBD) of complex aneurysms. Methods: This was a single centre retrospective analysis prospective study including all consecutive patients treated by FEVAR and the IBD performed with E-ventus BX stent grafts as bridging stents. Demographics of patients, the diameter and length of the bridging stent grafts, technical success, reinterventions, occlusions, post-operative events, and imaging (computed tomography [CT] scan and ultrasound) were prospectively collected in an electronic database. Follow-ups were performed with clinical assessment and a CT angiogram scan at four weeks after discharge followed by a duplex ultrasound every six months for two years and then a yearly duplex scan afterwards. Results: Between June 2015 and October 2017, 40 consecutive patients (three females) were treated with custom made fenestrated endografts and the iliac branch device for complex aneurysms, using the E-Ventus BX stent graft. All 82 E-Ventus BX stent grafts were successfully delivered and deployed. There was no in-hospital mortality. The early bridging stents patency rate was 97.6% (80 out of 82). The two-target vessel post-operative occlusion was secondary to kink of the renal stents and failure for re-lining of the renal artery. Of the two patients, only one needed permanent dialysis. On the late follow-up (after 30 days), two other patients demonstrated a renal stent occlusion, with one treated successfully with re-lining of the stent and the other patient treated conservatively. Neither of them needed permanent dialysis. A follow-up was maintained for 36 patients until April 2018 with a median follow-up of 18 months. All bridging stents E-Ventus BX stent grafts remained patent (78 out of 82, 95.1%). Conclusion: E-Ventus BX stent grafts used as bridging stents during FEVAR and the IBD are associated with favourable outcomes at the mid-term follow-up. Long-term follow-up is required to confirm these promising results.
Collapse
Affiliation(s)
- Tamer Sayed
- Vascular and Endovascular Surgery Department, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK
| | - Islam Ahmed
- Vascular and Endovascular Surgery Department, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK
| | - Alexander Rodway
- Vascular and Endovascular Surgery Department, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK
| | - Karim El Sakka
- Vascular and Endovascular Surgery Department, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK
| | - Syed Waquar Yusuf
- Vascular and Endovascular Surgery Department, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK
| |
Collapse
|
19
|
Marques de Marino P, Botos B, Kouvelos G, Verhoeven EL, Katsargyris A. Use of Bilateral Cook Zenith Iliac Branch Devices to Preserve Internal Iliac Artery Flow During Endovascular Aneurysm Repair. Eur J Vasc Endovasc Surg 2019; 57:213-219. [DOI: 10.1016/j.ejvs.2018.08.002] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2018] [Accepted: 08/01/2018] [Indexed: 11/15/2022]
|
20
|
Verzini F, Cieri E, Parlani G, Pula G, Simonte G. Comparison of aortoiliac repair with iliac branch endoprosthesis versus hypogastric occlusion in aortoiliac aneurysms. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 2019. [DOI: 10.23736/s1824-4777.18.01390-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
Surgical internal iliac artery preservation associated with endovascular repair of infrarenal aortoiliac aneurysms to avoid buttock claudication and distal type I endoleaks. J Vasc Surg 2018; 68:1736-1743. [DOI: 10.1016/j.jvs.2018.03.416] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2017] [Accepted: 03/05/2018] [Indexed: 11/21/2022]
|
22
|
Riambau V, Yugueros X, Blanco C, Mestres G. Endovascular solutions for iliac aneurysms. ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY 2018. [DOI: 10.23736/s1824-4777.18.01357-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
23
|
Bosiers MJ, Panuccio G, Bisdas T, Stachmann A, Donas KP, Torsello G, Austermann M. Longer bridging stent-grafts in iliac branch endografting does not worsen outcome and expands its applicability, even in concomitant diseased hypogastric arteries. THE JOURNAL OF CARDIOVASCULAR SURGERY 2018; 61:191-195. [PMID: 30370756 DOI: 10.23736/s0021-9509.18.10504-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The iliac side branch device (IBD) is a valid method for the treatment of abdominal aorto-iliac aneurysms. However there is still a lack of evidence regarding the optimal length of the bridging stent graft (BSG) since aneurysmal degeneration of the hypogastric artery (HA) is an exclusion criterion. The aim of this study was to analyse the impact of longer BSG compared to the widely used 38mm stent-grafts in terms of reintervention rate and primary patency. METHODS We retrospectively analyzed our prospectively collected database of all patients who underwent an endovascular aneurysm repair using an IBD in our center between April 2005 and May 2015. The used BSGs were divided into 2 groups. In group A, the BSG was ≤38 mm, and group B>38 mm. The primary endpoint was BSG-related events, including stenosis, occlusion or endoleak. Secondary endpoints were technical success, primary patency and 30-day mortality. RESULTS Two hundred sixty IBDs were implanted in 215 consecutive patients. Ninetyseven (37%) in group A and 163 (63%) in group B. The technical success rate was 100%. The 30-day mortality was 1% (N.=1) and 1.2% (N.=2) respectively for group A and B (P=0.8). The freedom from BSG-related events amounted to 84% at 60 months for the total cohort. The comparison between the two groups shows no significant difference, while a slight favorable trend for group B (75% vs. 91% at 60 months, P=0.081) was observed. No differences were found as to primary patency (96% and 99% at 60 months respectively for group A and B, P=0.237). CONCLUSIONS The use of longer stent-grafts (>38 mm) seems not to affect the performance of BSG even in the long run, expanding the indication for IBD also for aneurysms of the hypogastric artery.
Collapse
Affiliation(s)
- Michel J Bosiers
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany -
| | - Giuseppe Panuccio
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Theodosios Bisdas
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Arne Stachmann
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Konstantinos P Donas
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Giovanni Torsello
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| | - Martin Austermann
- Clinic for Vascular and Endovascular Surgery, St. Franziskus Hospital, Münster, Germany
| |
Collapse
|
24
|
Hypogastric Preservation Using Retrograde Endovascular Bypass. Ann Vasc Surg 2018; 52:67-71. [DOI: 10.1016/j.avsg.2018.04.018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Revised: 04/10/2018] [Accepted: 04/15/2018] [Indexed: 11/24/2022]
|
25
|
|
26
|
Endoprótesis GORE ® EXCLUDER ® con rama iliaca para el tratamiento de aneurismas aortoiliacos. Experiencia multicéntrica. Resultados a un año. ANGIOLOGIA 2018. [DOI: 10.1016/j.angio.2017.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
27
|
Giaquinta A, Ardita V, Ferrer C, Beggs CB, Veroux M, Barbante M, Orrico M, Cao P, Veroux P. Isolated Common Iliac Artery Aneurysms Treated Solely With Iliac Branch Stent-Grafts: Midterm Results of a Multicenter Registry. J Endovasc Ther 2018; 25:169-177. [PMID: 30141378 DOI: 10.1177/1526602818754862] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To assess early and midterm outcomes of iliac branch device (IBD) implantation without an aortic stent-graft for the treatment of isolated common iliac artery aneurysm (CIAA). METHODS From December 2006 to June 2016, 49 isolated CIAAs in 46 patients were treated solely with an IBD at 7 vascular centers. Five patients were lost to follow-up, leaving 41 male patients (mean age 72.5±7.8 years) for analysis. Mean CIAA diameter was 39.1±10.5 mm (range 25-65). Thirty-two patients (2 with bilateral CIAAs) were treated with a Cook Zenith iliac branch device; 9 patients (1 bilateral) received a Gore Excluder iliac branch endoprosthesis. Primary endpoints were technical success, survival, aneurysm exclusion, device patency, and freedom from reintervention at 1 and 5 years. Freedom from major adverse events and aneurysm shrinkage at 1 year were also assessed. RESULTS Thirty-day mortality and the IBD occlusion rate were 2.4% and 2.3%, respectively. At a mean follow-up of 40.2±33.9 months, no patient presented buttock claudication, erectile dysfunction, or bowel or spinal cord ischemia. Three patients died within 6 months after the procedure. Estimates of cumulative survival, device patency, and freedom from reintervention were 90.2%, 95.2%, and 95.7%, respectively, at 1 and 5 years. At 1 year, CIAA shrinkage ≥5 mm was recorded in 21 of 38 survivors. No evidence of endoleak, device migration, or disconnection was found on imaging follow-up. CONCLUSION The use of IBDs without an aortic stent-graft for isolated CIAAs resulted in excellent patency, with low morbidity and mortality. This, in conjunction with no endoleak or migration and a low reintervention rate, supports the use of isolated IBDs as a stable and durable means of endovascular reconstruction in cases with suitable anatomy. Longer follow-up and a larger cohort are needed to validate these results.
Collapse
Affiliation(s)
- Alessia Giaquinta
- 1 Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Italy
| | - Vincenzo Ardita
- 1 Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Italy
| | - Ciro Ferrer
- 2 Department of Surgery "Pietro Valdoni," "Sapienza" University, Rome, Italy
| | - Clive B Beggs
- 3 Research Institute for Sport, Physical Activity and Leisure, Carnegie Faculty, Leeds Beckett University, Leeds, UK
| | - Massimiliano Veroux
- 1 Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Italy
| | - Matteo Barbante
- 4 Vascular Surgery Unit, Department of Biomedicine and Prevention, University of Rome "Tor Vergata," Rome, Italy
| | - Matteo Orrico
- 5 Department of Vascular Surgery, San Filippo Neri Hospital, Rome, Italy
| | - Piergiorgio Cao
- 6 Division of Vascular Surgery, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy
| | - Piefrancesco Veroux
- 1 Vascular Surgery and Organ Transplant Unit, University Hospital of Catania, Italy
| | | |
Collapse
|
28
|
The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg 2018; 67:2-77.e2. [DOI: 10.1016/j.jvs.2017.10.044] [Citation(s) in RCA: 1150] [Impact Index Per Article: 191.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
29
|
Bannazadeh M, Jenkins C, Forsyth A, Kramer J, Aggarwal A, Somerset AE, Bove PG, Long GW. Outcomes for concomitant common iliac artery aneurysms after endovascular abdominal aortic aneurysm repair. J Vasc Surg 2017; 66:1390-1397. [DOI: 10.1016/j.jvs.2017.02.058] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Accepted: 02/23/2017] [Indexed: 12/11/2022]
|
30
|
Naji F, Srivatsav V, Qadura M, Harlock J, Andrinopoulos T, Iyer V, Rapanos T. Evaluating the Effectiveness of Internal Iliac Artery Branched Endovascular Stent Grafts. Ann Vasc Surg 2017; 45:247-252. [PMID: 28689946 DOI: 10.1016/j.avsg.2017.06.126] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 06/14/2017] [Accepted: 06/16/2017] [Indexed: 11/18/2022]
Abstract
BACKGROUND The aim of this study is to describe our institutional experience using iliac branch grafts (IBGs) in aortoiliac aneurysm repair. METHODS From October 2009 to April 2016, 41 consecutive patients (all men), mean age 71.7 years (range 55-87), underwent IBG implantation. Abdominal aortic aneurysm with common iliac artery involvement (n = 21) or bilateral common iliac artery aneurysms (n = 20) were indications. Computed tomography was used to evaluate patency and postoperative endoleaks within 1 month of implantation and after 1 year. RESULTS A total of 42 IBGs were deployed in 41 patients successfully. One hundred percent of grafts implanted were patent at 1 month and at annual follow-up. There was 1 mortality at 30 days, due to acute renal failure. Sixteen type II and 1 type Ib endoleaks were found, for which 3 reinterventions were performed and the remainder treated conservatively. Five patients had complications which required reintervention. CONCLUSIONS IBG placement has excellent short-term outcomes and potential to limit buttock claudication in the treatment of abdominal aortic aneurysms involving the iliac arteries.
Collapse
Affiliation(s)
- Faysal Naji
- Division of Vascular Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada.
| | - Varun Srivatsav
- Michael G. DeGroote School of Medicine, Faculty of Health Sciences, McMaster University, Hamilton, ON, Canada
| | - Mohammed Qadura
- Division of Vascular Surgery, Department of Surgery, St. Michael's Hospital, Toronto, ON, Canada
| | - John Harlock
- Division of Vascular Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Tara Andrinopoulos
- Division of Vascular Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Vikram Iyer
- Division of Vascular Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| | - Theodore Rapanos
- Division of Vascular Surgery, Department of Surgery, McMaster University, Hamilton, ON, Canada
| |
Collapse
|
31
|
Bargay Juan P, Plaza Martínez A, Pepén Moquete L, Ramírez Montoya M, Molina Nacher V, Gómez Palonés F. Sellado distal en ilíaca externa: ramificación ilíaca frente a la exclusión de la arteria hipogástrica. ANGIOLOGIA 2017. [DOI: 10.1016/j.angio.2017.01.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
32
|
Simonte G, Parlani G, Farchioni L, Isernia G, Cieri E, Lenti M, Cao P, Verzini F. Lesson Learned with the Use of Iliac Branch Devices: Single Centre 10 Year Experience in 157 Consecutive Procedures. Eur J Vasc Endovasc Surg 2017; 54:95-103. [DOI: 10.1016/j.ejvs.2017.03.026] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Accepted: 03/31/2017] [Indexed: 01/29/2023]
|
33
|
Kim D, Chung JK, Park HS, Jung IM, Lee T. Early Experiences of Sandwich Technique to Preserve Pelvic Circulation during Endovascular Aneurysm Repair. Vasc Specialist Int 2017; 33:72-80. [PMID: 28690999 PMCID: PMC5493190 DOI: 10.5758/vsi.2017.33.2.72] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 05/18/2017] [Accepted: 05/19/2017] [Indexed: 11/20/2022] Open
Abstract
Purpose To report experiences of the sandwich technique (ST) for preservation of pelvic flow during endovascular repair of complex aortic or aortoiliac aneurysms. Materials and Methods Eight patients underwent elective endovascular aneurysm repair (EVAR) using the ST between March 2013 and February 2017. The anatomic indications for the ST were complex aortoiliac aneurysms (5 cases), abdominal aortic aneurysms (AAA) with non-diseased short common iliac arteries (2 cases) and AAA with unilateral occluded iliac artery (1 case). The ST was performed through both femoral and brachial approach. Patient clinical and radiologic data were collected and analyzed. Results Eight patients (7 male; mean age, 73.4 years) were followed over a mean period of 277 days (range, 9–1,106 days). The technical success rate was 100%. The primary patency rate of the iliac stent-grafts was 88% (14/16 cases). One internal iliac and 1 external iliac stent-graft occlusion was observed during the early postoperative period. There was 1 gutter endoleak which disappeared spontaneously within 4 days, and there were 2 type II endoleaks: one treated by coil embolization after 13 months, and the other observed without treatment. There were no cases of sac growth or aneurysm-related deaths, and no cases of buttock claudication or impotence. Conclusion The ST is a safe and feasible technique to preserve pelvic circulation during endovascular treatment of complex aortoiliac aneurysms. The need to expand the indications for complex EVARs with adjunctive procedures, such as the ST is highlighted in situations where branched/fenestrated device availability is limited.
Collapse
Affiliation(s)
- Daehwan Kim
- Department of Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.,Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Jung Kee Chung
- Department of Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.,Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Hyung Sub Park
- Department of Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.,Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - In Mok Jung
- Department of Surgery, SMG-SNU Boramae Medical Center, Seoul, Korea.,Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Taeseung Lee
- Department of Surgery, Seoul National University Bundang Hospital, Seongnam, Korea.,Department of Surgery, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
34
|
Shin SH, Starnes BW. Bifurcated-bifurcated aneurysm repair is a novel technique to repair infrarenal aortic aneurysms in the setting of iliac aneurysms. J Vasc Surg 2017; 66:1398-1405. [PMID: 28502552 DOI: 10.1016/j.jvs.2017.02.044] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 02/10/2017] [Indexed: 11/28/2022]
Abstract
BACKGROUND Up to 40% of abdominal aortic aneurysms (AAAs) have coexistent iliac artery aneurysms (IAAs). In the past, successful endovascular repair required internal iliac artery (IIA) embolization, which can lead to pelvic or buttock ischemia. This study describes a technique that uses a readily available solution with a minimally altered off-the-shelf bifurcated graft in the IAA to maintain IIA perfusion. METHODS From August 2009 to May 2015, 14 patients with AAAs and coexisting IAAs underwent repair with a bifurcated-bifurcated approach. A 22-mm or 24-mm bifurcated main body device was used in the IAA with extension of the "contralateral" limb into the IIA. Intraoperative details including operative time, fluoroscopy time, and contrast agent use were recorded. Outcome measures assessed were operative technical success and a composite outcome measure of IIA patency, freedom from reintervention, and clinically significant endoleak at 1 year. RESULTS Fourteen patients underwent bifurcated-bifurcated repair during the study period. Technical success was achieved in 93% of patients, with successful treatment of the AAA and IAA and preservation of flow to at least one IIA. The procedure was performed with a completely percutaneous bilateral femoral approach in 92% of patients. Three patients had a type II endoleak on initial follow-up imaging, but none were clinically significant. There were no cases of bowel ischemia or erectile dysfunction. One patient had buttock claudication ipsilateral to IIA coil embolization (contralateral to bifurcated iliac repair and preserved IIA) that resolved by 6-month follow-up. Two patients required reinterventions. One patient presented to his first follow-up visit on postoperative day 25 with thrombosis of the right external iliac limb ipsilateral to the bifurcated iliac repair, which was successfully treated with thrombectomy and stenting of the limb. This same patient presented at 83 months with growth of the preserved IIA to 3.9 cm and underwent coil embolization of the aneurysm. Another patient presented for surveillance 44 months after his original repair with component separation of the mating stent and the iliac bifurcated stent grafts. This was treated with a limb extension and endoanchors to fuse the endografts. Of the 13 patients who underwent bifurcated-bifurcated repair, 100% of the preserved IIAs remained patent at last follow-up. The composite outcome measure of IIA patency and freedom from reintervention and clinically significant endoleak at 1 year was 92% (n = 12/13). CONCLUSIONS In this small retrospective review, bifurcated-bifurcated aneurysm repair of aortoiliac aneurysms with preservation of perfusion to the IIA is technically feasible and safe with good short-term and midterm results in male patients.
Collapse
|
35
|
Yugueros X, Mestres G, Pasquadibisceglie S, Alomar X, Apodaka A, Riambau V. Parallel-Stenting Technique in a Sandwich Configuration for Hypogastric Artery Preservation during Endovascular Aneurysm Repair: An In Vitro Study. Ann Vasc Surg 2017; 44:221-228. [PMID: 28483625 DOI: 10.1016/j.avsg.2017.03.202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 03/30/2017] [Indexed: 11/18/2022]
Abstract
BACKGROUND The aim of the study was to identify the best conditions in iliac sandwich procedure for hypogastric artery preservation during endovascular aneurysm repair, testing different devices, different oversizing (OS) degrees as well as different methods to measure it. METHODS Four external iliac devices (16-mm Endurant and 12-mm Aorfix limb extensions; 11- and 13-mm Viabahn endografts) were tested with 2 distinct internal iliac stent grafts (8-mm Advanta V12 and 8-mm Viabahn) inside different proximal silicon iliac limb models (10, 12, 14, 16, and 18 mm), simulating an iliac sandwich procedure for hypogastric preservation. After remodeling all devices in a saline bath at 37°C, the combinations were computed tomography scanned. Gutter size, parallel-stent compression, and inadequate parallel-stent deployment or infolding were recorded. Oversizing between both parallel stents and the iliac limb models were examined in terms of added diameter, perimeter, and area being additionally compared. RESULTS All three sizing methods (diameter, perimeter, and area) were highly correlated (diameter OS to perimeter and area OS correlation coefficient 0.998 and 0.997, respectively, P < 0.001 for both); thus, diameter OS was used for further comparisons. Increasing diameter OS (< 30%, 30-55%, 55-75%, and > 75%) showed a significant tendency toward smaller gutters (38.9, 12.2, 5.4, and 2.6 mm2, respectively, P < 0.001) but also increasing parallel-stent compression (13.5%, 28.9%, 43.9%, and 55.1%, P < 0.001) and infolding (0%, 0%, 38%, and 60%, P < 0.001). There were no significant differences between the analyzed devices. CONCLUSIONS In iliac sandwich procedures, better apposition is usually achieved when using 30-55% diameter OS; higher OS is related to smaller gutters but higher rates of malpositioning and parallel-stent compression. No clear recommendations in material selection can be performed. All sizing methods are highly correlated and predictable.
Collapse
Affiliation(s)
- Xavier Yugueros
- Vascular Surgery Division, Cardiovascular Institute, Hospital Clinic, Barcelona, Spain.
| | - Gaspar Mestres
- Vascular Surgery Division, Cardiovascular Institute, Hospital Clinic, Barcelona, Spain
| | | | - Xavier Alomar
- Department of Radiology, Clínica Creu Blanca, Barcelona, Spain
| | - Ana Apodaka
- Vascular Surgery Division, Cardiovascular Institute, Hospital Clinic, Barcelona, Spain
| | - Vincent Riambau
- Vascular Surgery Division, Cardiovascular Institute, Hospital Clinic, Barcelona, Spain
| |
Collapse
|
36
|
Delay C, Deglise S, Lejay A, Georg Y, Roussin M, Schaeffer M, Saucy F, Thaveau F, Corpataux JM, Chakfe N. Zenith Bifurcated Iliac Side Branch Device: Mid-term Results and Assessment of Risk Factors for Intraoperative Thrombosis. Ann Vasc Surg 2017; 41:141-150. [PMID: 28238918 DOI: 10.1016/j.avsg.2016.08.048] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Revised: 08/03/2016] [Accepted: 08/23/2016] [Indexed: 11/17/2022]
Abstract
BACKGROUND The aim of this study is to evaluate the short- and mid-term results of the Zenith bifurcated iliac side branch device (ZBIS) in the treatment of common iliac artery (CIA) aneurysms, and to assess risk factors for intraoperative internal iliac artery (IIA) thrombosis. METHODS All patients who underwent endovascular treatment of either an isolated CIA aneurysm or an aortoiliac aneurysm using the ZBIS device in the departments of vascular surgery of Strasbourg (France) and Lausanne (Switzerland) between January 2010 and December 2014 were retrospectively collected. RESULTS Thirty-one implantations were performed: 30 patients underwent 31 endovascular CIA aneurysm treatments with the ZBIS device. Mean operative time was 188 min. Technical success was obtained in 26 implantations (84%). In 5 implantations (16%), the final angiogram revealed an IIA thrombosis. Thirty-day mortality was 3.2%. Thirty-day morbidity was 13.3%. Mean follow-up was 15 months. Overall survival was 96% at 1 year and 89% at 2 years. In intention-to-treat analysis, primary patency of the internal iliac side branch was 84% at 1 year and 76% at 2 years (5 peroperative IIA occlusions and 1 late occlusion). Freedom from reintervention was 89% at 1 and 2 years. One case of type III endoleak and 2 cases of type II endoleaks were identified. Only type III endoleak required an additional intervention with a covered stent. Aneurysm diameter decreased in 15 implantations (48%) and remained stable in 16 implantations (52%). Clinical, radiological, and peroperative parameters were analyzed to identify risk factor for intraoperative thrombosis of the internal iliac side branch. Notion of intraoperative difficulties (any additional procedure that was not initially planned and increasing the operating time) appeared as a risk factor in multivariate analysis (P < 0.01, standard deviation 1.27, odds ratio 30.6). CONCLUSIONS The main findings of our study is that the procedure can be difficult to perform in particular conditions and can lead to peroperative failure in these cases, highlighting the need for adequate patients screening. When technical success is obtained, outcomes can be considered as satisfactory.
Collapse
Affiliation(s)
- Charline Delay
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Sébastien Deglise
- Department of Vascular Surgery, University Hospital of Lausanne, Lausanne, Switzerland
| | - Anne Lejay
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Yannick Georg
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Mathieu Roussin
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Mickaël Schaeffer
- Department of Methodology and Biostatistics, University Hospital of Strasbourg, Strasbourg, France
| | - François Saucy
- Department of Vascular Surgery, University Hospital of Lausanne, Lausanne, Switzerland
| | - Fabien Thaveau
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France
| | - Jean-Marc Corpataux
- Department of Vascular Surgery, University Hospital of Lausanne, Lausanne, Switzerland
| | - Nabil Chakfe
- Department of Vascular Surgery and Kidney Transplantation, University Hospital of Strasbourg, Strasbourg, France.
| |
Collapse
|
37
|
Jongsma H, Bekken JA, Bekkers WJJ, Zeebregts CJ, van Herwaarden J, Hoksbergen A, Cuypers P, de Vries JPPM, Verhagen HJ, Fioole B. Endovascular Treatment of Common Iliac Artery Aneurysms With an Iliac Branch Device. J Endovasc Ther 2016; 24:239-245. [DOI: 10.1177/1526602816679132] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To evaluate the efficacy, feasibility, and long-term outcomes of the Zenith ZBIS iliac branch device (IBD) to preserve internal iliac artery (IIA) perfusion in a large Dutch multicenter cohort. Methods: Between September 2004 and August 2015, 140 patients (mean age 70.9±7.4 years; 130 men) with 162 IBD implantations were identified in 7 vascular centers. The indication for IBD implantation was an abdominal aortic aneurysm >55 mm with a concomitant common iliac artery (CIA) aneurysm >20 mm (n=40), a CIA aneurysm with a diameter >30 mm (n=89), or revision of a type Ib endoleak after endovascular aneurysm repair (n=11). Results: Technical success (aneurysm exclusion, no type I or III endoleak, and a patent IIA) was obtained in 157 (96.9%) of 162 IBD implantations. Six (4.3%) patients developed major complications; 2 (1.4%) died. Mean follow-up was 26.6±24.1 months, during which 17 (12.1%) IBD-associated secondary interventions were performed. Including technical failures and intentional IIA embolizations, 15 (9.3%) IIA branch occlusions were identified; buttock claudication developed in 6 of these patients. The freedom from secondary intervention estimate was 75.9% (95% confidence interval 59.7 to 86.3) at 5 years. Conclusion: CIA aneurysms can be treated safely and effectively by IBDs with preservation of antegrade flow to the IIA. Secondary interventions are indicated in >10% of patients during follow-up but can be performed endovascularly in most.
Collapse
Affiliation(s)
- Hidde Jongsma
- Department of Vascular Surgery, Maasstad Hospital, Rotterdam, the Netherlands
| | - Joost A. Bekken
- Department of Vascular Surgery, Maasstad Hospital, Rotterdam, the Netherlands
| | | | - Clark J. Zeebregts
- Department of Vascular Surgery, University Medical Center, Groningen, the Netherlands
| | - Joost van Herwaarden
- Department of Vascular Surgery, University Medical Center, Utrecht, the Netherlands
| | - Arjan Hoksbergen
- Department of Vascular Surgery, Vrije Universiteit Medical Center, Amsterdam, the Netherlands
| | - Philip Cuypers
- Department of Vascular Surgery, Catharina Hospital, Eindhoven, the Netherlands
| | | | - Hence J. Verhagen
- Department of Vascular Surgery, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Bram Fioole
- Department of Vascular Surgery, Maasstad Hospital, Rotterdam, the Netherlands
| |
Collapse
|
38
|
Kouvelos GN, Katsargyris A, Antoniou GA, Oikonomou K, Verhoeven ELG. Outcome after Interruption or Preservation of Internal Iliac Artery Flow During Endovascular Repair of Abdominal Aorto-iliac Aneurysms. Eur J Vasc Endovasc Surg 2016; 52:621-634. [PMID: 27600731 DOI: 10.1016/j.ejvs.2016.07.081] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Accepted: 07/19/2016] [Indexed: 11/25/2022]
Abstract
AIM The aim was to conduct a systematic review of the literature investigating outcomes after interruption or preservation of the internal iliac artery (IIA) during endovascular aneurysm repair (EVAR). METHODS A systematic review was undertaken using the MEDLINE and EMBASE databases to identify studies reporting IIA management during EVAR. The search identified 57 articles: 30 reported on IIA interruption (1468 patients) and 27 on IIA preservation (816 patients). RESULTS The pooled 30 day buttock claudication (BC) rate was 29.2% (95% CI 24.2-34.7). Patients undergoing bilateral IIA interruption had a higher incidence of BC than patients with unilateral IIA interruption (36.5% vs. 27.2%, OR 1.7, 95% CI 1.11-2.6, p = .01). During a median follow up of 17 months, the pooled rate of persistent BC was 20.5% (95% CI 15.7-26.2). Of the patients, 93.9% underwent an endovascular revascularization procedure for IIA preservation. Most patients (87.6%) had an iliac branched device, and technical success was 96.2%. Within 30 days of EVAR, 4.3% of internal iliac branches occluded. During a median follow up of 15 months, the pooled occlusion rate at the site of IIA revascularization was 8.8% (95% CI 6.8-11.3). In patients treated with an iliac-branched device, 5.2% of internal iliac branches and 1.7% of external iliac arteries occluded. The pooled BC rate on the side of the IIA revascularization during follow up was 4.1% (95% CI 2.9-5.9). Pooled rates of late device related endoleak type I or III and secondary procedures on the side of the previous IIA revascularization were 4.6% (95% CI 3.2-6.5) and 7.8% (95% CI 5.7-10.7) respectively. CONCLUSION Unilateral or bilateral IIA occlusion during EVAR seems to carry a substantial risk of significant ischemic complications in nearly one quarter of patients. Bilateral IIA occlusion was related to a significantly higher rate of BC. IIA preservation techniques represent a significant improvement in the treatment of aorto-iliac aneurysms and have been associated with high technical success and low morbidity.
Collapse
Affiliation(s)
- G N Kouvelos
- Department of Vascular and Endovascular Surgery, Paracelsus Medical University Nuremberg, Germany.
| | - A Katsargyris
- Department of Vascular and Endovascular Surgery, Paracelsus Medical University Nuremberg, Germany
| | - G A Antoniou
- Department of Vascular and Endovascular Surgery, The Royal Oldham Hospital, Pennine Acute Hospitals NHS Trust, Manchester, UK
| | - K Oikonomou
- Department of Vascular and Endovascular Surgery, Paracelsus Medical University Nuremberg, Germany
| | - E L G Verhoeven
- Department of Vascular and Endovascular Surgery, Paracelsus Medical University Nuremberg, Germany
| |
Collapse
|
39
|
Massmann A, Mosquera Arochena NJ, Shayesteh-Kheslat R, Buecker A. Endovascular anatomic reconstruction of the iliac bifurcation with covered stentgrafts in sandwich-technique for the treatment of complex aorto-iliac aneurysms. Int J Cardiol 2016; 222:332-339. [PMID: 27500759 DOI: 10.1016/j.ijcard.2016.07.226] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2016] [Accepted: 07/29/2016] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Endovascular anatomic reconstruction of iliac artery bifurcation in aorto-iliac aneurysms using commercial stentgrafts in sandwich-technique by bilateral transfemoral approach. METHODS 24 patients (mean 73.8±standard deviation 6.8years) with complex aorto-iliac aneurysms (AAA): n=17; diameter 64±15 [48-100]mm; common-iliac-artery (CIA): n=27; 43±15 [30-87]mm; internal-iliac-artery (IIA): n=14; 28±8 [15-43]mm) were prospectively enrolled for EVAR with preservation of the IIA (n=31; bi-lateral n=7). Maintenance of antegrade flow to IIA by iliac reconstruction was performed in sandwich-technique prior to EVAR. Follow-up of 15.0±10.8 [1-40]months included contrast-enhanced ultrasound and computed-tomography after 1week, 3, 6 and every 12months. RESULTS Initial technical success for anatomic reconstruction of the iliac arteries in 31 instances was 100%. Primary patency of iliac neo-bifurcations was 90.9% (20/22) at 6months and 84.2% (16/19) at 1year. Postprocedural gutter-endoleaks type 1b were obvious in 6.5% (2/31) of cases, which disappeared 3months later. Aortic/iliac aneurysm-size after 1year decreased (>5mm) in 61.5% of patients. No aneurysm-size increase or late rupture occurred. CONCLUSIONS Endovascular reconstruction of the iliac bifurcation with commercial standard stentgrafts is safe and effective. Transfemoral approach allows extension of distal landing zone for EVAR while preserving the internal iliac artery blood-flow, even in unfavorable iliac anatomy.
Collapse
Affiliation(s)
- Alexander Massmann
- Clinic for Diagnostic and Interventional Radiology, Saarland University Medical Center, 66421 Homburg, Saar, Germany.
| | | | - Roushanak Shayesteh-Kheslat
- Clinic for Vascular and Endovascular Surgery, Saarland University Medical Center, 66421 Homburg, Saar, Germany.
| | - Arno Buecker
- Clinic for Diagnostic and Interventional Radiology, Saarland University Medical Center, 66421 Homburg, Saar, Germany.
| |
Collapse
|
40
|
Rieß HC, Kölbel T, Diener H, Heidemann F, Debus ES, Rohlffs F, Tsilimparis N. Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement. J Endovasc Ther 2016; 23:800-2. [DOI: 10.1177/1526602816656449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: To report implantation of an iliac branch device (IBD) for preserving antegrade blood flow to a sole internal iliac artery (IIA) via an ipsilateral approach during endovascular repair to reline an aortobi-iliac allograft. Technique: The technique is described in a 55-year-old man with an enteric fistula involving an aortobi-iliac Y-prosthesis. After complete excision, the prosthesis was replaced by an allograft. Due to rebleeding and resuturing of the graft, total stent-graft relining of the allograft was planned with preservation of the sole left IIA using an iliac side branch (ZBIS). During introduction of a 12-F sheath over the allograft’s neobifurcation to establish a femorofemoral through-and-through approach, the allograft ruptured. A compliant balloon was inflated to control the hemorrhage. The IBD was first fully deployed, followed by stent-graft relining. Consequently, stent-graft implantation in the left IIA using a crossover maneuver was no longer feasible, so a 0.035-inch super stiff wire was introduced through the IBD’s 20-F sheath. A 12-mm semi-compliant balloon was inflated in the common iliac artery above the iliac branch to act as an abutment for a 7-F sheath to run over the stiff wire into the IIA for delivery/deployment of a stent-graft. Conclusion: It is feasible to use a complete ipsilateral femoral approach for IBD implantation after aortic stent-graft placement.
Collapse
Affiliation(s)
- Henrik Christian Rieß
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - Tilo Kölbel
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - Holger Diener
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - Franziska Heidemann
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - E. Sebastian Debus
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - Fiona Rohlffs
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| | - Nikolaos Tsilimparis
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
41
|
Kansal V, Jetty P, Kubelik D, Hajjar G, Hill A, Brandys T, Nagpal S. Internal iliac coverage during endovascular repair of abdominal aortic aneurysms is a safe option: A preliminary study. Vascular 2016; 25:28-35. [PMID: 27000384 DOI: 10.1177/1708538116640077] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Endovascular aneurysm repairs lacking suitable common iliac artery landing zones occasionally require graft limb extension into the external iliac artery, covering the internal iliac artery origin. The purpose of this study was to assess incidence of type II endoleak following simple coverage of internal iliac artery without embolization during endovascular aneurysm repair. Three hundred eighty-nine endovascular aneurysm repairs performed by a single surgeon (2004-2015) were reviewed. Twenty-seven patients underwent simple internal iliac artery coverage. Type II endoleak was assessed from operative reports and follow-up computed tomography imaging. No patient suffered type II endoleak from a covered internal iliac artery in post-operative computed tomography scans. Follow-up ranged from 0.5 to 9 years. No severe pelvic ischemic complications were observed. In conclusion, for selected cases internal iliac artery coverage without embolization is a safe alternative to embolization in endovascular aneurysm repairs, where the graft must be extended into the external iliac artery.
Collapse
Affiliation(s)
- Vinay Kansal
- 1 Faculty of Medicine, University of Ottawa, Ottawa, Canada.,2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada
| | - Prasad Jetty
- 2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada.,3 Ottawa Hospital Research Institute, University of Ottawa, Ottawa, Canada
| | - Dalibor Kubelik
- 2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada.,3 Ottawa Hospital Research Institute, University of Ottawa, Ottawa, Canada
| | - George Hajjar
- 2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada.,3 Ottawa Hospital Research Institute, University of Ottawa, Ottawa, Canada
| | - Andrew Hill
- 2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada.,3 Ottawa Hospital Research Institute, University of Ottawa, Ottawa, Canada
| | - Tim Brandys
- 2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada.,3 Ottawa Hospital Research Institute, University of Ottawa, Ottawa, Canada
| | - Sudhir Nagpal
- 2 Division of Vascular Surgery, University of Ottawa, Ottawa, Canada.,3 Ottawa Hospital Research Institute, University of Ottawa, Ottawa, Canada
| |
Collapse
|
42
|
Modified Sandwich-graft Technique Employing Aorfix and Viabahn Stent-grafts to Preserve Hypogastric Flow in Cases of Complex Aortoiliac and Isolated Common Iliac Artery Aneurysms Including the Internal Iliac Artery Ostium. Eur J Vasc Endovasc Surg 2016; 51:364-70. [DOI: 10.1016/j.ejvs.2015.10.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2015] [Accepted: 10/13/2015] [Indexed: 11/20/2022]
|
43
|
Lahoz C, Gracia CE, García LR, Montoya SB, Hernando ÁB, Heredero ÁF, Tembra MS, Velasco MB, Guijarro C, Ruiz EB, Pintó X, de Ceniga MV, Moñux Ducajú G. [Not Available]. CLINICA E INVESTIGACION EN ARTERIOSCLEROSIS : PUBLICACION OFICIAL DE LA SOCIEDAD ESPANOLA DE ARTERIOSCLEROSIS 2016; 28 Suppl 1:1-49. [PMID: 27107212 DOI: 10.1016/s0214-9168(16)30026-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Affiliation(s)
- Carlos Lahoz
- Unidad de Lípidos y Riesgo Vascular, Servicio de Medicina Interna, Hospital Carlos III, Madrid, España.
| | - Carlos Esteban Gracia
- Servicio de Angiología y Cirugía Vascular, Hospital Universitari Germans Trias i Pujol, Badalona, Barcelona, España
| | | | - Sergi Bellmunt Montoya
- Servicio de Angiología y Cirugía Vascular, Hospital de la Santa Creu i Sant Pau, Barcelona, España
| | - Ángel Brea Hernando
- Unidad de Lípidos, Servicio de Medicina Interna, Hospital San Pedro, Logroño, España
| | | | - Manuel Suárez Tembra
- Unidad de Lípidos y Riesgo Cardiovascular, Servicio de Medicina Interna, Hospital San Rafael, A Coruña, España
| | - Marta Botas Velasco
- Servicio de Angiología y Cirugía Vascular, Hospital de Cabueñes, Gijón, España
| | - Carlos Guijarro
- Consulta de Riesgo Vascular, Unidad de Medicina Interna, Hospital Universitario Fundación Alcorcón, Alcorcón, Madrid, España
| | - Esther Bravo Ruiz
- Servicio de Angiología y Cirugía Vascular, Hospital Universitario de Basurto, Bilbao, España
| | - Xavier Pintó
- Unidad de Riesgo Vascular, Servicio de Medicina Interna, Hospital Universitario de Bellvitge, L' Hospitalet de Llobregat, Barcelona, España
| | - Melina Vega de Ceniga
- Servicio de Angiología y Cirugía Vascular, Hospital de Galdakao-Usansolo, Vizcaya, España
| | | |
Collapse
|
44
|
Youssef M, Nurzai Z, Zerwes S, Jakob R, Dünschede F, Dorweiler B, Vahl CF. Initial Experience in the Treatment of Extensive Iliac Artery Aneurysms With the Nellix Aneurysm Sealing System. J Endovasc Ther 2016; 23:290-6. [DOI: 10.1177/1526602815627357] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To assess the feasibility and effectiveness of the Nellix prosthesis in the treatment of common iliac artery aneurysms. Methods: Between May 2013 and June 2015, 230 patients underwent implantation of the Nellix device at 2 institutions. Fifty of these patients (mean age 76 years; 35 men) were identified as having 60 common iliac artery aneurysms (CIAAs) with a median diameter of 4 cm (range 3.5–7). The majority of patients had aortoiliac aneurysms (5, 70%), 10 (20%) had isolated CIAAs, and 5 (10%) had iliac anastomotic aneurysms after aortoiliac bypass. In 20 patients, the iliac aneurysm was the indication for the intervention; in the other 30 patients, the endovascular iliac repair was an adjunct procedure to endovascular aneurysm sealing (EVAS). An iliac branch device (IBD) was used when feasible to preserve flow to the internal iliac artery. Results: Seventeen (34%) patients underwent elective implantation of the Nellix graft in combination with an IBD, 33 (66%) patients underwent Nellix sealing of the CIAA using 1 (n=5), 2 (n=22), or 3 Nellix grafts (2 bilateral grafts and 1 graft as an extension to the external iliac artery in 6 patients). The technical success rate was 100%, and no graft-related complications were reported postoperatively. No buttock claudication, reinterventions, graft thrombosis, or endoleaks were observed during a mean follow-up of 12 months. Conclusion: Our initial experience demonstrates that Nellix grafts are feasible and safe for the treatment of extensive iliac artery aneurysms. The long-term durability of these grafts should be validated in larger patient cohorts before this promising alternative endovascular technique can gain widespread acceptance.
Collapse
Affiliation(s)
- Marwan Youssef
- Department of Cardiothoracic and Vascular Surgery, Medical Center of the Johannes Gutenberg-University Mainz, Germany
| | - Zmarai Nurzai
- Department of Vascular Surgery, Hospital of Augsburg, Germany
| | | | - Rudolf Jakob
- Department of Vascular Surgery, Hospital of Augsburg, Germany
| | - Fritz Dünschede
- Department of Cardiothoracic and Vascular Surgery, Medical Center of the Johannes Gutenberg-University Mainz, Germany
| | - Bernhard Dorweiler
- Department of Cardiothoracic and Vascular Surgery, Medical Center of the Johannes Gutenberg-University Mainz, Germany
| | - Christian F. Vahl
- Department of Cardiothoracic and Vascular Surgery, Medical Center of the Johannes Gutenberg-University Mainz, Germany
| |
Collapse
|
45
|
Treatment of iliac artery bifurcation aneurysms with the second-generation straight iliac bifurcated device. J Vasc Surg 2015; 62:1168-75. [DOI: 10.1016/j.jvs.2015.06.135] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2015] [Accepted: 06/03/2015] [Indexed: 11/24/2022]
|
46
|
Kobayashi Y, Sakaki M, Yasuoka T, Iida O, Dohi T, Uematsu M. Endovascular repair with contralateral external-to-internal iliac artery bypass grafting: a case series. BMC Res Notes 2015; 8:183. [PMID: 25935638 PMCID: PMC4434537 DOI: 10.1186/s13104-015-1144-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2014] [Accepted: 04/22/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND To report a technique of keeping unilateral blood flow in the internal iliac artery in cases of an abdominal aortic aneurysm in achieving successful Endovascular abdominal aortic aneurysm repair using an external-to-internal artery bypass. CASE PRESENTATION 6 japanese patients with infra-renal abdominal aortic aneurysms were treated using the retroperitoneal approach via a left (right) paramedian incision followed by an external-to-internal artery bypass. Endovascular abdominal aortic aneurysm repair was conducted on mean postoperative day 29 ± 18 and was performed because the contralateral internal iliac artery, which was not involved in the external-to-internal artery bypass, was treated with a coil embolization. No complications developed during the postoperative follow-up period (17 ± 1.5 months). In all 6 patients, patent grafts were evident on computed tomography angiography scans even after 1-3 months. CONCLUSIONS Endovascular abdominal aortic aneurysm repair with unilateral internal iliac artery embolization and contralateral external-to-internal artery bypass is feasible with a relatively low risk. It is a safe procedure and reduces the incidence of postoperative complications.
Collapse
Affiliation(s)
- Yasuhiko Kobayashi
- Department of Cardiovascular Surgery, Kansai Rosai Hospital, 3-1-69 Inabaso, Amagasaki, Hyogo, 660-8511, Japan.
| | - Masayuki Sakaki
- Department of Cardiovascular Surgery, Kansai Rosai Hospital, 3-1-69 Inabaso, Amagasaki, Hyogo, 660-8511, Japan.
| | - Takashi Yasuoka
- Department of Cardiovascular Surgery, Kansai Rosai Hospital, 3-1-69 Inabaso, Amagasaki, Hyogo, 660-8511, Japan.
| | - Osamu Iida
- Departments of Cardiology, Kansai Rosai Hospital, 3-1-69 Inabaso, Amagasaki, Hyogo, 660-8511, Japan.
| | - Tomoharu Dohi
- Departments of Cardiology, Kansai Rosai Hospital, 3-1-69 Inabaso, Amagasaki, Hyogo, 660-8511, Japan.
| | - Masaaki Uematsu
- Departments of Cardiology, Kansai Rosai Hospital, 3-1-69 Inabaso, Amagasaki, Hyogo, 660-8511, Japan.
| |
Collapse
|
47
|
Shahverdyan R, Gray D, Gawenda M, Brunkwall J. Technical feasibility of endovascular aortoiliac aneurysm repair combining Anaconda fenestrated and Zenith iliac side-branched stent grafts. J Vasc Surg 2015; 61:1324-8. [DOI: 10.1016/j.jvs.2013.10.089] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2013] [Revised: 10/21/2013] [Accepted: 10/21/2013] [Indexed: 10/25/2022]
|
48
|
Wu IH, Chou HW, Chang CH, Lin CF, Chi NH, Wang SS. Crossover chimney technique to preserve the internal iliac artery during endovascular repair of iliac or aortoiliac aneurysms: midterm results. J Endovasc Ther 2015; 22:388-95. [PMID: 25878024 DOI: 10.1177/1526602815581596] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE To report our midterm results of the crossover chimney technique to preserve the internal iliac artery (IIA) in patients with aortoiliac aneurysms (AIA) and isolated common iliac artery aneurysms (CIAA). METHODS Between May 2012 and January 2014, 14 consecutive patients (mean age 77.3 years; all men) with 17 AIA, isolated CIAAs, or abdominal aortic aneurysms with short CIAs underwent elective endovascular aneurysm repair (EVAR) with the crossover chimney technique to preserve the IIA. Follow-up assessment, including computed tomographic angiography or duplex ultrasound, was performed at 1, 6, and 12 months and annually thereafter. RESULTS Technical success, defined as successful preservation of IIA without intraoperative type I or III endoleak, was 100%. Over a mean 14.3 months (range 6-21), primary patency was 92.8%. There was no early or late procedure-related mortality. Among the 17 iliac aneurysms excluded, the sac diameter significantly (at least 5 mm) decreased in 3, decreased <5 mm in 10, and did not change in 4. CONCLUSION The crossover chimney technique is a simple and safe alternative for IIA endovascular revascularization with high technical success and acceptable midterm patency.
Collapse
Affiliation(s)
- I-Hui Wu
- Division of Cardiovascular Surgery, Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Heng-Wen Chou
- Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan Division of Cardiovascular Surgery, Department of Surgery, National Taiwan University Hospital, Yun-Lin Branch, Yun Lin, Taiwan
| | - Chin-Hao Chang
- Department of Medical Research, National Taiwan University Hospital, Taipei, Taiwan
| | - Ching-Feng Lin
- Institute of Epidemiology and Preventive Medicine, College of Public Health, National Taiwan University, Taipei, Taiwan
| | - Nai-Hsin Chi
- Division of Cardiovascular Surgery, Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Shoei-Shen Wang
- Division of Cardiovascular Surgery, Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|
49
|
Gray D, Shahverdyan R, Jakobs C, Brunkwall J, Gawenda M. Endovascular Aneurysm Repair of Aortoiliac Aneurysms with an Iliac Side-branched Stent graft: Studying the Morphological Applicability of the Cook Device. Eur J Vasc Endovasc Surg 2015; 49:283-8. [DOI: 10.1016/j.ejvs.2014.12.021] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2014] [Accepted: 12/15/2014] [Indexed: 11/29/2022]
|
50
|
Endovascular Hypogastric Artery Preservation During Endovascular Aneurysm Repair: A Review of Current Techniques and Devices. Ann Vasc Surg 2015; 29:367-76. [DOI: 10.1016/j.avsg.2014.10.019] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Revised: 10/21/2014] [Accepted: 10/25/2014] [Indexed: 11/23/2022]
|