1
|
Karathanos C, Spanos K, Batzalexis K, Chaidoulis A, Tzimas-Dakis K, Volakakis G, Kouvelos G, Matsagas M, Giannoukas AD. Endovenous thermal ablation mid-term outcomes for the treatment of large diameter incompetent great saphenous veins. Phlebology 2024:2683555241272971. [PMID: 39162354 DOI: 10.1177/02683555241272971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/21/2024]
Abstract
INTRODUCTION The aim of this study was to assess the efficacy and safety of endovenous thermal ablation (EVTA) in treating large diameter, ≥12 mm, incompetent great saphenous vein (GSV) in comparison to smaller ones. METHODS A retrospective comparative study was undertaken including 196 patients (205 limbs) undergoing EVTA. According to maximum GSV diameter patients were divided into two groups (group A <12 mm, group B ≥12 mm). Primary outcome was anatomic success defined as absence of reflux of GSV. Secondary outcomes were complications, postoperative pain using the 10-cm Visual Analog Scale (VAS) and improvement of Venous Clinical Severity Score (VCSS) and Chronic Venous Insufficiency Quality-of-Life Questionnaire (CΙVIQ-20) scores assessed at 7- days, 1 month, 12 months and 24 months postoperatively. RESULTS 118 patients with GSV diameter <12 mm (group A) and 87 with GSV diameter ≥12 mm (group B) were included. Patients' demographics, CEAP classification and length of ablated vein did not differ between the groups. Preoperative VCSS and VAS pain score were significant greater in group B (6.03 vs 6.94, p = .04 and 5.21 vs 5.77, p = .032, respectively). No differences in adverse events were observed post-operatively among groups. GSV occlusion rate at 1 month was 98.3% (SE 1.3%) in group A and 96.5 % (2.2%) in group B (p = .3), at 12 months 95.7% (SE 2%) and 94.2% (SE 2.8%) (p = .5), and at 24 months 94% (SE 2.4%) and 93.1% (SE 3%) (p = .4) respectively. Both groups experienced significant and similar improvement in their VCSSs and CIVIQ scores postoperatively. In a subgroup analysis among different EVTA and GSV >12 mm, 1470 nm endovenous laser ablation (EVLA) and radiofrequency ablation (RFA) showed comparable results in terms of occlusion rates, complications, VCSS and CIVIQ scores. CONCLUSIONS Endovenous thermal ablation techniques are efective and safe in the treatment of GSV incompetence regardless the diameter of the GSV. Both 1470 nm EVLA and RFA techniques performed similar outcomes.
Collapse
Affiliation(s)
- Christos Karathanos
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Konstantinos Spanos
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Konstantinos Batzalexis
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Athanasios Chaidoulis
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Konstantinos Tzimas-Dakis
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Georgios Volakakis
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - George Kouvelos
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Miltiadis Matsagas
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| | - Athanasios D Giannoukas
- Department of Vascular Surgery, University Hospital of Larissa, Faculty of Medicine, School of Health Sciences, University of Thessaly, Larissa, Greece
| |
Collapse
|
2
|
Gaspar RJ, Castro AN, Simões MDJ, Plapler H. Real time echo-guided endolaser for thermal ablation without perivenous tumescence. J Vasc Bras 2015. [DOI: 10.1590/1677-5449.07214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Abstract Background There is no consensus in the medical literature on the ideal procedure for endovenous laser application. Objective To assess the safety and efficacy of real time echo-guided endovenous laser for thermal ablation of great saphenous vein (GSV) incompetence, without perivenous tumescence. Methods Thirty-four limbs of patients with CEAP clinical scores of 2 to 6 and bilateral incompetence of the saphenofemoral junction (SFJ) and GSV, confirmed by Echo-Doppler, underwent endovenous laser therapy and were followed for 1 year. Laser ablation was performed using a 600 µ bare optical fiber introduced endovenously close to the malleolus along the full extent of the GSV in an anterograde direction, using a standardized echo-Doppler-guided AND? 15 watt continuous mode 980 nm diode laser with real-time monitoring of thermal ablation of the whole target vein. Adverse effects and complications were recorded. Results Hyperesthesia, cellulitis, and fibrous cord, all transitory, developed in 2.9% of the 34 limbs treated; 8.8% developed hypoesthesia in the perimalleolar region, which was transitory and had no clinical consequences; there were no cases of deep venous thrombosis. Immediate occlusion was achieved in 100% of the 34 saphenous veins that underwent photocoagulation, although one exhibited recanalization without reflux at 1-month follow-up. After 6 months and 1 year, occlusion was 100% according to echo-Doppler findings. Conclusions Real-time echo-guided 980 nm endovenous laser ablation without perivenous tumescence provided controlled thermal ablation with safe, effective, immediate and medium-term GSV occlusion and can therefore be recommended as a method for the treatment of chronic venous disease.
Collapse
Affiliation(s)
- Ricardo José Gaspar
- Universidade Federal de São Paulo, Brazil; Sociedade Brasileira de Angiologia e Cirurgia Vascular, Brazil; Instituto Vascular Ricardo Gaspar, Brazil
| | | | | | | |
Collapse
|
3
|
Recek C. Significance of Reflux Abolition at the Saphenofemoral Junction in Connection with Stripping and Ablative Methods. Int J Angiol 2015; 24:249-61. [PMID: 26648666 DOI: 10.1055/s-0035-1546439] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
Saphenous reflux interferes with the physiological decrease in pressure and induces ambulatory venous hypertension. Elimination of reflux is achieved by flush ligation at the incompetent saphenofemoral junction and stripping of the great saphenous vein, which is the basis of the conventional surgical therapy. Endovenous ablative methods substitute stripping by thermal of chemical destruction of the saphenous trunk; they usually refrain from saphenofemoral junction ligation. Short-term and medium-term results up to 5 years, achieved after endovenous ablation without high ligation, are comparable with those after conventional surgery, which questioned the necessity to ligate the incompetent saphenofemoral junction. Nevertheless, clinical symptoms caused by recurrent reflux occur as a rule not earlier than 8 to 10 years after efficient abolition of reflux. Consequently, randomized studies with long-term follow-ups exceeding 10 years are necessary for trustworthy assessment whether it is justified to abstain from saphenofemoral junction ligation.
Collapse
Affiliation(s)
- Cestmir Recek
- Retired from Department of Surgery, University Hospital, Hradec Kralove, Czech Republic
| |
Collapse
|
4
|
van Eekeren RRJP, Hillebrands JL, van der Sloot K, de Vries JPPM, Zeebregts CJ, Reijnen MMPJ. Histological observations one year after mechanochemical endovenous ablation of the great saphenous vein. J Endovasc Ther 2015; 21:429-33. [PMID: 24915593 DOI: 10.1583/13-4588mr.1] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To report histological analysis of a great saphenous vein (GSV) 1 year after undergoing mechanochemical endovenous ablation (MOCA) and compare the findings with those of a healthy vein. CASE REPORT A 59-year-old patient with bilateral GSV incompetence was treated with MOCA using the ClariVein catheter, which has a dispersion wire that rotates as liquid sclerosant is injected in the vein. After 1 year, the patient had recurrent edema of the right leg; duplex ultrasound was suspicious for recanalization. The patient was reoperated, and the deep femoral vein was explored. The GSV was completely obliterated, and its proximal part was excised and sent for histological processing. Microscopic evaluation of the MOCA-treated vein showed a circumferential disappearance of the endothelial layer and fibrosis of the vein. The media was considerably damaged, with changes in collagen structure, supporting the therapeutic effect of MOCA. CONCLUSION MOCA is a novel endovenous treatment modality for saphenous vein insufficiency. Results of MOCA on the cellular level are essential to optimize treatment.
Collapse
|
5
|
Starodubtsev V, Lukyanenko M, Karpenko A, Ignatenko P. Endovenous laser ablation in patients with wide diameter of the proximal segment of the great saphenous vein: Comparison of methods. Phlebology 2014; 30:700-5. [DOI: 10.1177/0268355514555546] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objective To estimate the safety and efficacy of using the laser 1560 nm wavelength for treatment of chronic venous disease in patients with wide diameters of the proximal segment of the great saphenous vein. Methods In the study 88 patients with lower limb varicose veins were included. Maximum diameter of the great saphenous vein proximal segment varied from 15 to 34 mm (22 ± 2.3) in all patients. In the 1st group in 34 cases crossektomy and endovenous laser ablation (EVLA) were performed. In the 2nd group in 30 cases EVLA regardless diameter of the great saphenous vein proximal segment was performed. In the 3rd group in 34 cases EVLA taking into account the diameter of the great saphenous vein proximal segment was performed. The laser 1560 nm wavelength was used. Linear endovenous energy density in the 1st and 2nd groups was 90 J/cm for the proximal segment and trunk of great saphenous vein. Linear endovenous energy density in the 3rd group was personalized on the size of the veins: 100 J/cm for diameter of great saphenous vein proximal segment 15–20 mm, 150 J/cm for diameter 20–30 mm, 90 J/cm for middle and distal segments of great saphenous vein. Results In the 1st group obliteration of the trunk of the great saphenous veins and accessory great saphenous veins in all cases without additional interventions was reached. In the 2nd group at four cases (13.3%) the second procedure EVLA was carried out, after which the obliteration of the trunk was achieved. In the 3rd group the obliteration of the trunk of great saphenous vein was achieved without additional interventions. Conclusion Our experience of using the laser 1560 nm wavelength for the treatment of the chronic venous disease in patients with wide diameter of the proximal segment of great saphenous vein shows the safety and efficacy of this technique. EVLA has to be personalized on the size of the segments of vein in patients with wide proximal segment of great saphenous vein.
Collapse
Affiliation(s)
- V Starodubtsev
- Novosibirsk Research Institute of Circulation Pathology named by Meshalkin, Novosibirsk, Russian Federation
| | - M Lukyanenko
- Novosibirsk Research Institute of Circulation Pathology named by Meshalkin, Novosibirsk, Russian Federation
| | - A Karpenko
- Novosibirsk Research Institute of Circulation Pathology named by Meshalkin, Novosibirsk, Russian Federation
| | - P Ignatenko
- Novosibirsk Research Institute of Circulation Pathology named by Meshalkin, Novosibirsk, Russian Federation
| |
Collapse
|
6
|
Passariello F. Post Ablation Superficial Thrombus Extension (PASTE) as a consequence of endovenous ablation. An up-to-date review. ACTA ACUST UNITED AC 2014. [DOI: 10.1016/j.rvm.2014.01.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
7
|
Mlosek RK, Woźniak W, Gruszecki L, Stapa RZ. The use of a novel method of endovenous steam ablation in treatment of great saphenous vein insufficiency: own experiences. Phlebology 2012; 29:58-65. [PMID: 23117895 DOI: 10.1258/phleb.2012.012092] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Endovascular procedures are gaining more and more popularity as treatment of great saphenous vein (GSV) incompetence. The purpose of the present study was to assess the efficacy of steam GSV ablation. METHODS Steam ablation using the steam vein sclerosis system (CERMA, France) was performed in 20 patients with GSV incompetence. The efficacy of the procedure was evaluated using ultrasound and the following parameters were assessed: changes in lumen diameter, GSV wall thickness, reflux and presence/absence of blood flow. RESULTS The GSV steam ablation resulted in the obliteration of the vein lumen in all patients - reflux or blood flow were not observed in any subject. A significant decrease of GSV lumen diameter and an increase of GSV wall thickness were also observed in all subjects following the procedure. No postoperative complications were noted. The steam ablation technique was also positively assessed by the patients. CONCLUSIONS Steam ablation is an endovascular surgical technique, which can become popular and widely used due to its efficacy and safety. It is also easy to use and patient-friendly. The research on its use should be continued.
Collapse
Affiliation(s)
- R K Mlosek
- Department of Diagnostic Imaging of the II Medical Faculty of the Medical University of Warsaw
| | | | | | | |
Collapse
|
8
|
Corcos L, Pontello D, DE Anna D, Dini S, Spina T, Barucchello V, Carrer F, Elezi B, DI Benedetto F. Endovenous 808-nm diode laser occlusion of perforating veins and varicose collaterals: a prospective study of 482 limbs. Dermatol Surg 2011; 37:1486-98. [PMID: 21883649 DOI: 10.1111/j.1524-4725.2011.02133.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Endovenous laser ablation (EVLA) was performed in the treatment of great and small saphenous veins (GSVs, SSVs), perforating veins (PVs), and varicose collaterals (VCs). OBJECTIVE To verify the outcome in PVs and VCs. MATERIALS AND METHODS Four hundred eighty-two limbs of 306 patients were studied. EVLA was performed on 167 GSVs, 52 SSVs, and 534 PVs of 303 limbs and on VCs of 467 limbs; 133 GSVs were stripped, 300 of saphenofemoral junctions (SFJs) and 45 saphenopopliteal junctions (SPJs) were interrupted. Limbs were selected using duplex ultrasound examination and photographs; PVs-VCs diameter (<4 mm) and VC length were measured. EVLA was performed using a 808-nm diode laser, 0.6-mm fibers, continuous emission, 4 to 10 W, and 10 to 20 J/cm. Follow-up on 467 limbs occurred over a mean 27.5 months (range 3 months to 6 years); 98 limbs were followed up for longer than 4 years. RESULTS Operating time range from 10 to 30 minutes per limb. Blood vaporization, thrombosis, fibrosis, and atrophy prevailed in PVs and in the large VCs (>4 mm) and massive coagulation in the smaller (<4 mm). High rate of occlusion was seen, with different rates of patent PV-VC mainly in diameter >6 mm. Thirty-nine out of 511 patent PVs (7.6%) and 96 out of 778 VCs (12-13%) were re-treated using EVLA or foam sclerotherapy. Minor complications occurred in 88 of the 778 (11%). CONCLUSIONS EVLA of PVs and VCs is effective and faster than surgery in 2- to 6-mm PVs and VCs using an 808-nm diode laser.
Collapse
Affiliation(s)
- Leonardo Corcos
- Department of Surgical Sciences, Postgraduate School of Vascular Surgery, University of Udine, Udine, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Brar R, Nordon IM, Hinchliffe RJ, Loftus IM, Thompson MM. Surgical management of varicose veins: meta-analysis. Vascular 2010; 18:205-20. [PMID: 20643030 DOI: 10.2310/6670.2010.00013] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Open surgery remains the gold standard by which endovascular treatment of superficial chronic venous insufficiency is measured. This meta-analysis of randomized controlled trials reviews the current evidence base, comparing open and endovascular treatment of varicose veins. Systematic review of studies reporting duplex scan follow-up after open surgical, laser (endovenous laser therapy [EVLT]), or radiofrequency (VNUS Closure device, VNUS Medical Technologies, San Jose, CA) treatment of refluxing great saphenous veins was completed. Primary outcome measures were occlusion and complication rates and time taken to resume work. No significant difference in recurrence rates at 3 months between open surgery and EVLT (RR 2.19, 95% CI 0.99-4.85, p = .05) or VNUS device (RR 7.57; 95% CI 0.42-136.02) were found. Return to work is significantly faster following VNUS (by 8.24 days; 95% CI 10.50-5.97) or EVLT (by 5.02 days; 95% CI 6.52-3.52). Endovascular treatment of varicose veins is safe and effective and offers the significant advantage of rapid recovery.
Collapse
Affiliation(s)
- Ranjeet Brar
- St George's Vascular Institute, St George's Hospital, London, UK.
| | | | | | | | | |
Collapse
|
10
|
Almeida J, Mackay E, Javier J, Mauriello J, Raines J. Saphenous Laser Ablation at 1470 nm Targets the Vein Wall, Not Blood. Vasc Endovascular Surg 2009; 43:467-72. [DOI: 10.1177/1538574409335916] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The 2 primary objectives of this study were to investigate whether the 1470-nm wavelength can close a saphenous vein painlessly and determine safety, efficacy, and side effects of the 1470-nm laser. In all, 26 limbs were treated in the Dominican Republic, with a radially-emitting fiber at low energy ranging from 20 J/cm to 30 J/cm. Perivenous anesthesia was used selectively. Then 41 veins were treated with the 1470-nm laser at 30 J/cm at 5 watts, using standard perivenous tumescent anesthesia in Miami and compared to a historical control (980 nm, 80 J/cm, and 12 watts). We demonstrated that the 1470-nm wavelength endovenous laser system could not close saphenous veins without use of anesthesia. Closure with a dramatic reduction in energy when compared to a 980-nm wavelength control demonstrated a marked reduction in postoperative pain and ecchymosis; this implies that vein-wall perforations are minimized with this system.
Collapse
|