1
|
Bajda J, Park AN, Raj A, Raj R, Gorantla VR. Inferior Vena Cava Filters and Complications: A Systematic Review. Cureus 2023; 15:e40038. [PMID: 37287823 PMCID: PMC10243179 DOI: 10.7759/cureus.40038] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/05/2023] [Indexed: 06/09/2023] Open
Abstract
Inferior vena cava (IVC) filters have been used since the 1960s to treat patients with acute risk of pulmonary embolism (PE) to prevent migration of thrombus by trapping it within the filter. Traditional usage has been in patients with contraindication to anticoagulation that carry a significant mortality risk. In this systematic review, we sought to evaluate complications associated with placement of inferior vena cava filters based on published data from the past 20 years. A search was performed on October 6th, 2022, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for systematic reviews, using three databases (ProQuest, PubMed and ScienceDirect) for articles published between the dates of February 1, 2002 and October 1, 2022. Results were filtered to include full-text, clinical studies, and randomized trials written in English pertaining to keywords "IVC filter AND complications", "Inferior Vena Cava Filter AND complications", "IVC filter AND thrombosis" and "Inferior Vena Cava Filter AND thrombosis". Articles identified by the three databases were pooled and further screened for relevance based on inclusion and exclusion criteria. Initial search results yielded 33,265 hits from all three databases combined. Screening criteria were applied, with 7721 results remaining. After further manual screening, including removal of duplicate hits, a total of 117 articles were selected for review. While there are no consensus guidelines for best practice, there is compelling evidence that IVC filters can provide significant protection against PE with minimal complications if the treatment window is appropriate. Increase in the variety of filter models has led to broader availability, but skepticism remains about their efficacy and safety, with ongoing controversy surrounding appropriate indications. Further research is needed to establish clear guidelines on appropriate indications for IVC placement and to determine time course of complications versus benefits for indwelling filters.
Collapse
Affiliation(s)
- Joe Bajda
- Anatomical Sciences, St. George's University School of Medicine, True Blue, GRD
| | - Ann N Park
- Medicine, St. George's University School of Medicine, True Blue, GRD
| | - Aishwarya Raj
- Vascular Surgery, St. George's University School of Medicine, True Blue, GRD
| | - Rhea Raj
- Anatomical Sciences, St. George's University School of Medicine, True Blue, GRD
| | | |
Collapse
|
2
|
Liu J, Jiang P, Tian X, Jia W, Huang NL, Zhan H, Chen W. Clinical outcomes of retrievable inferior vena cava filters for venous thromboembolic diseases. J Comp Eff Res 2022; 11:437-449. [PMID: 35199584 DOI: 10.2217/cer-2021-0291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Aim: To identify literature evidence assessing retrievable inferior vena cava filter (rIVCF) for venous thromboembolic diseases. Methods: A systematic literature search was conducted to identify relevant references from the mainstay English and Chinese bibliographic databases (search period: January 2003 to October 2019). Results: 80 original studies with 11,413 patients were included in this review. The success rates of deploying the six types of rIVCFs ranged from 98.4 to 100.0%. Denali had the highest retrieval success rate (95.4-97.6%). The incidence rates of fracture and perforation associated with retrieving the six rIVCFs were less than 2%. Conclusion: The approved rIVCF had comparable clinical profiles, except that Denali was easier to be retrieved than other rIVCF.
Collapse
Affiliation(s)
| | - Peng Jiang
- Beijing Jishuitan Hospital, Beijing, China
| | - Xuan Tian
- Beijing Jishuitan Hospital, Beijing, China
| | - Wei Jia
- Beijing Jishuitan Hospital, Beijing, China
| | | | - Huan Zhan
- Changsha Normin Health Technology Ltd, Changsha, China
| | - Wendong Chen
- Changsha Normin Health Technology Ltd, Changsha, China.,Normin Health Consulting Ltd, Toronto, Canada
| |
Collapse
|
3
|
Merritt T, Powell C, Hansmann J. Safety and Effectiveness of Advanced Retrieval Techniques for Inferior Vena Cava Filters Compared to Standard Retrieval Techniques: A Systematic Review of the Literature and Meta-Analysis. J Vasc Interv Radiol 2022; 33:564-571.e4. [DOI: 10.1016/j.jvir.2022.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 12/20/2021] [Accepted: 01/20/2022] [Indexed: 10/19/2022] Open
|
4
|
Han K, Kim MD, Kim GM, Kwon JH, Lee J, Won JY, Moon S, An H. Comparison of Retrievability and Indwelling Complications of Celect and Denali Infrarenal Vena Cava Filters: A Randomized, Controlled Trial. Cardiovasc Intervent Radiol 2021; 44:1536-1542. [PMID: 34312689 DOI: 10.1007/s00270-021-02928-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 07/15/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE To compare the Celect and Denali filters in terms of complex filter retrieval and indwelling complications after a 2-month indwelling time. MATERIALS AND METHODS In this prospective, randomized trial, 153 subjects were assessed for eligibility between May 2016 and July 2018. A total of 136 participants were randomly assigned to receive either Celect (n = 68) or Denali (n = 68) filter placement in the infrarenal inferior vena cava. Tilt angles at placement and retrieval and rates of overall filter retrieval, indwelling complication, and complex retrieval were compared. RESULTS Of 136 participants (mean age, 62 ± 12.8 years, 55 male), 24 (17.6%) were lost to follow-up. The mean indwelling time of filter was 60.4 ± 7 days and there was no significant difference in the baseline characteristics between the two groups. Filter retrieval was successful in all participants (112/112, 100%). Significantly higher rates of filter tilt > 15° (n = 8) and strut penetration (n = 14) were found with the Celect filter than with the Denali filter (1 significant tilt and 1 penetration) (P = 0.033 and 0.001, respectively). No filter fractures were observed and there was no significant difference in tip embedment, filter fracture, filter migration, or mean fluoroscopy times. There were 3 cases of complex retrieval (1 for Denali vs. 2 for Celect, P = 0.500), for which the loop-snare technique was used. CONCLUSION Denali filters demonstrated significantly lower rates of tilt angle > 15° and strut penetration. However, there was no significant difference in the complex filter retrieval rate between the Celect and Denali filters.
Collapse
Affiliation(s)
- Kichang Han
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| | - Man-Deuk Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea.
| | - Gyoung Min Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| | - Joon Ho Kwon
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| | - Junhyung Lee
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| | - Jong Yun Won
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| | - Sungmo Moon
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| | - Hyeongsu An
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50-1 Yonsei-ro Seodaemun-gu, Seoul, 03722, Korea
| |
Collapse
|
5
|
Dhawan I, Palchaudhuri S, Ginsberg GG. The Unexpected Perpetrator: A Story of Indigestion. Gastroenterology 2021; 160:e11-e12. [PMID: 32504641 DOI: 10.1053/j.gastro.2020.05.074] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 05/11/2020] [Indexed: 12/02/2022]
Affiliation(s)
- Ishita Dhawan
- Department of Medicine, Pennsylvania Hospital, University of Pennsylvania Health System, Philadelphia, Pennsylvania.
| | - Sonali Palchaudhuri
- Division of Gastroenterology, Department of Medicine, Hospital of the University of Pennsylvania, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| | - Gregory G Ginsberg
- Division of Gastroenterology, Department of Medicine, Hospital of the University of Pennsylvania, University of Pennsylvania Health System, Philadelphia, Pennsylvania
| |
Collapse
|
6
|
A Review of the Currently Available Retrievable and Next Generation Inferior Vena Cava Filters. CURRENT RADIOLOGY REPORTS 2019. [DOI: 10.1007/s40134-019-0341-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
7
|
The Clinical Rationale for the Sentry Bioconvertible Inferior Vena Cava Filter for the Prevention of Pulmonary Embolism. Int J Vasc Med 2019; 2019:5795148. [PMID: 31263598 PMCID: PMC6556320 DOI: 10.1155/2019/5795148] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 03/27/2019] [Indexed: 11/17/2022] Open
Abstract
The Sentry inferior vena cava (IVC) filter is designed to provide temporary protection against pulmonary embolism (PE) during transient high-risk periods and then to bioconvert after 60 days after implantation. At the time of bioconversion, the device's nitinol arms retract from the filtering position into the caval wall. Subsequently, the stable stent-like nitinol frame is endothelialized. The Sentry bioconvertible IVC filter has been evaluated in a multicenter investigational-device-exemption pivotal trial (NCT01975090) of 129 patients with documented deep vein thrombosis (DVT) or PE, or at temporary risk of developing DVT or PE, and with contraindications to anticoagulation. Successful filter conversion was observed in 95.7% of patients at 6 months (110/115) and 96.4% at 12 months (106/110). Through 12 months, there were no cases of symptomatic PE. The rationale for development of the Sentry bioconvertible device includes the following considerations: (1) the period of highest risk of PE for the vast majority of patients occurs within the first 60 days after an index event, with most of the PEs occurring in the first 30 days; (2) the design of retrievable IVC filters to support their removal after a transitory high-PE-risk period has, in practice, been associated with insecure filter dynamics and time-dependent complications including tilting, fracture, embolization, migration, and IVC perforation; (3) most retrievable IVC filters are placed for temporary protection, but for a variety of reasons they are not removed in any more than half of implanted patients, and when removal is attempted, the procedure is not always successful even with advanced techniques; and (4) analysis of Medicare hospital data suggests that payment for the retrieval procedure does not routinely compensate for expense. The Sentry device is not intended for removal after bioconversion. In initial clinical use, complications have been limited. Long-term results for the Sentry bioconvertible IVC filter are anticipated soon.
Collapse
|