1
|
Jabeen S, Baines PM, Harlaar J, Vallery H, Berry A. Reaction moments matter when designing lower-extremity robots for tripping recovery. PLoS One 2023; 18:e0280158. [PMID: 36809378 PMCID: PMC9942996 DOI: 10.1371/journal.pone.0280158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Accepted: 12/21/2022] [Indexed: 02/23/2023] Open
Abstract
Balance recovery after tripping often requires an active adaptation of foot placement. Thus far, few attempts have been made to actively assist forward foot placement for balance recovery employing wearable devices. This study aims to explore the possibilities of active forward foot placement through two paradigms of actuation: assistive moments exerted with the reaction moments either internal or external to the human body, namely 'joint' moments and 'free' moments, respectively. Both paradigms can be applied to manipulate the motion of segments of the body (e.g., the shank or thigh), but joint actuators also exert opposing reaction moments on neighbouring body segments, altering posture and potentially inhibiting tripping recovery. We therefore hypothesised that a free moment paradigm is more effective in assisting balance recovery following tripping. The simulation software SCONE was used to simulate gait and tripping over various ground-fixed obstacles during the early swing phase. To aid forward foot placement, joint moments and free moments were applied either on the thigh to augment hip flexion or on the shank to augment knee extension. Two realizations of joint moments on the hip were simulated, with the reaction moment applied to either the pelvis or the contralateral thigh. The simulation results show that assisting hip flexion with either actuation paradigm on the thigh can result in full recovery of gait with a margin of stability and leg kinematics closely matching the unperturbed case. However, when assisting knee extension with moments on the shank, free moment effectively assist balance but joint moments with the reaction moment on the thigh do not. For joint moments assisting hip flexion, placement of the reaction moment on the contralateral thigh was more effective in achieving the desired limb dynamics than placing the reaction on the pelvis. Poor choice of placement of reaction moments may therefore have detrimental consequences for balance recovery, and removing them entirely (i.e., free moment) could be a more effective and reliable alternative. These results challenge conventional assumptions and may inform the design and development of a new generation of minimalistic wearable devices to promote balance during gait.
Collapse
Affiliation(s)
- Saher Jabeen
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Patricia M. Baines
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- * E-mail:
| | - Jaap Harlaar
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Orthopedics, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Heike Vallery
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Rehabilitation Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| | - Andrew Berry
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
- Department of Rehabilitation Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands
| |
Collapse
|
2
|
Gait Recognition for Lower Limb Exoskeletons Based on Interactive Information Fusion. Appl Bionics Biomech 2022; 2022:9933018. [PMID: 35378794 PMCID: PMC8976668 DOI: 10.1155/2022/9933018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 11/10/2021] [Accepted: 03/05/2022] [Indexed: 11/18/2022] Open
Abstract
In recent decades, although the research on gait recognition of lower limb exoskeleton robot has been widely developed, there are still limitations in rehabilitation training and clinical practice. The emergence of interactive information fusion technology provides a new research idea for the solution of this problem, and it is also the development trend in the future. In order to better explore the issue, this paper summarizes gait recognition based on interactive information fusion of lower limb exoskeleton robots. This review introduces the current research status, methods, and directions for information acquisition, interaction, fusion, and gait recognition of exoskeleton robots. The content involves the research progress of information acquisition methods, sensor placements, target groups, lower limb sports biomechanics, interactive information fusion, and gait recognition model. Finally, the current challenges, possible solutions, and promising prospects are analysed and discussed, which provides a useful reference resource for the study of interactive information fusion and gait recognition of rehabilitation exoskeleton robots.
Collapse
|
3
|
Stensgaard Stoltze J, Pallari J, Eskandari B, Oliveira AS, Pirscoveanu CI, Rasmussen J, Andersen MS. Development and Functional Testing of An Unloading Concept for Knee Osteoarthritis Patients: A Pilot Study. J Biomech Eng 2021; 144:1114806. [PMID: 34286821 DOI: 10.1115/1.4051847] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Indexed: 11/08/2022]
Abstract
This paper presents a knee brace design that applies an extension moment to unload the muscles in stance phase during gait, and thereby the knee, as alternative to conventional valgus braces for knee osteoarthritis patients. The concept was tested on one healthy subject during normal gait with a prototype, which was designed to activate and deactivate in order to apply the extension moment in the stance phase only and hereby avoid any interference during the swing phase. Electromyography measurements and musculoskeletal models were used to evaluate the brace effects on muscle activation and knee compressive forces respectively. Simulations predicted an ideal reduction of up to 36%, whereas experimental tests revealed a reduction of up to 24% with the current prototype. The prototype brace also reduced the knee joint force impulse up to 9% and EMG peak signal of the vasti muscles with up to 19%. Due to these reductions on a healthy subject, this bracing approach seem promising for reducing knee loads during normal gait. However, further clinical experiments on knee osteoarthritis patients are required to evaluate the effect on both pain and disease progression.
Collapse
Affiliation(s)
| | - Jari Pallari
- Aalborg University, Department of Material and Production, Fibigerstraede 16, DK-9220 Aalborg East, Denmark
| | - Behrokh Eskandari
- Newcastle University, School of Engineering, Newcastle upon Tyne NE1 7RU, United Kingdom
| | | | | | | | | |
Collapse
|
4
|
Control of twin-double pendulum lower extremity exoskeleton system with fuzzy logic control method. Neural Comput Appl 2021. [DOI: 10.1007/s00521-020-05554-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
5
|
Pinto-Fernandez D, Torricelli D, Sanchez-Villamanan MDC, Aller F, Mombaur K, Conti R, Vitiello N, Moreno JC, Pons JL. Performance Evaluation of Lower Limb Exoskeletons: A Systematic Review. IEEE Trans Neural Syst Rehabil Eng 2021; 28:1573-1583. [PMID: 32634096 DOI: 10.1109/tnsre.2020.2989481] [Citation(s) in RCA: 54] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Benchmarks have long been used to verify and compare the readiness level of different technologies in many application domains. In the field of wearable robots, the lack of a recognized benchmarking methodology is one important impediment that may hamper the efficient translation of research prototypes into actual products. At the same time, an exponentially growing number of research studies are addressing the problem of quantifying the performance of robotic exoskeletons, resulting in a rich and highly heterogeneous picture of methods, variables and protocols. This review aims to organize this information, and identify the most promising performance indicators that can be converted into practical benchmarks. We focus our analysis on lower limb functions, including a wide spectrum of motor skills and performance indicators. We found that, in general, the evaluation of lower limb exoskeletons is still largely focused on straight walking, with poor coverage of most of the basic motor skills that make up the activities of daily life. Our analysis also reveals a clear bias towards generic kinematics and kinetic indicators, in spite of the metrics of human-robot interaction. Based on these results, we identify and discuss a number of promising research directions that may help the community to attain a comprehensive benchmarking methodology for robot-assisted locomotion more efficiently.
Collapse
|
6
|
McGibbon C, Sexton A, Jayaraman A, Deems-Dluhy S, Fabara E, Adans-Dester C, Bonato P, Marquis F, Turmel S, Belzile E. Evaluation of a lower-extremity robotic exoskeleton for people with knee osteoarthritis. Assist Technol 2021; 34:543-556. [PMID: 33571072 DOI: 10.1080/10400435.2021.1887400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
A multi-site study was conducted to evaluate the efficacy of the Keeogo™ exoskeleton as a mobility assist device for use in the clinic and at home in people with knee osteoarthritis (KOA). Twenty-four participants were randomized in a two-stage cross-over design that evaluated the immediate effects of using the exoskeleton in the clinic and the cumulative effects of training and home use. Immediate effects were quantified by comparing 1) physical performance with|without (W|WO) the device during a battery of mobility tests, and 2) physical activity levels at home (actigraphy) for one month, two weeks W|WO the device. Cumulative effects were quantified as change in physical performance W and WO over time. WOMAC and other self-report scales were measured and usability assessed. There were no immediate effects on physical performance or physical activity at home; however, there were cumulative effects as indicated by improved stair time (p = .001) as well as improved WOMAC pain (p = .004) and function (p = .003). There was a direct relationship between improved physical function and improved WOMAC pain (r = -.677, p < .001) and stiffness (r = .537, p = .007). Weight and battery life were identified as important to usability. A full-scale RCT with more participants, longer study period, and better usage monitoring is warranted.
Collapse
Affiliation(s)
- Chris McGibbon
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada
| | - Andrew Sexton
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, New Brunswick, Canada
| | - Arun Jayaraman
- Shirley Ryan AbilityLab (formerly Rehabilitation Institute of Chicago), Chicago, Illinois, USA
| | - Susan Deems-Dluhy
- Shirley Ryan AbilityLab (formerly Rehabilitation Institute of Chicago), Chicago, Illinois, USA
| | - Eric Fabara
- Dept of Physical Medicine & Rehabilitation, Harvard Medical School at Spaulding Rehabilitation Hospital, Boston, Massachusetts, USA
| | - Catherine Adans-Dester
- Dept of Physical Medicine & Rehabilitation, Harvard Medical School at Spaulding Rehabilitation Hospital, Boston, Massachusetts, USA
| | - Paolo Bonato
- Dept of Physical Medicine & Rehabilitation, Harvard Medical School at Spaulding Rehabilitation Hospital, Boston, Massachusetts, USA
| | - Francois Marquis
- Dept of Surgery, Division of Orthopedic Surgery, CHU de Québec-Université Laval, Québec, Québec City, Canada
| | - Sylvie Turmel
- Dept of Surgery, Division of Orthopedic Surgery, CHU de Québec-Université Laval, Québec, Québec City, Canada
| | - Etienne Belzile
- Dept of Surgery, Division of Orthopedic Surgery, CHU de Québec-Université Laval, Québec, Québec City, Canada
| |
Collapse
|
7
|
Human Activity Recognition through Recurrent Neural Networks for Human–Robot Interaction in Agriculture. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11052188] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The present study deals with human awareness, which is a very important aspect of human–robot interaction. This feature is particularly essential in agricultural environments, owing to the information-rich setup that they provide. The objective of this investigation was to recognize human activities associated with an envisioned synergistic task. In order to attain this goal, a data collection field experiment was designed that derived data from twenty healthy participants using five wearable sensors (embedded with tri-axial accelerometers, gyroscopes, and magnetometers) attached to them. The above task involved several sub-activities, which were carried out by agricultural workers in real field conditions, concerning load lifting and carrying. Subsequently, the obtained signals from on-body sensors were processed for noise-removal purposes and fed into a Long Short-Term Memory neural network, which is widely used in deep learning for feature recognition in time-dependent data sequences. The proposed methodology demonstrated considerable efficacy in predicting the defined sub-activities with an average accuracy of 85.6%. Moreover, the trained model properly classified the defined sub-activities in a range of 74.1–90.4% for precision and 71.0–96.9% for recall. It can be inferred that the combination of all sensors can achieve the highest accuracy in human activity recognition, as concluded from a comparative analysis for each sensor’s impact on the model’s performance. These results confirm the applicability of the proposed methodology for human awareness purposes in agricultural environments, while the dataset was made publicly available for future research.
Collapse
|
8
|
McGibbon CA, Brandon S, Bishop EL, Cowper-Smith C, Biden EN. Biomechanical Study of a Tricompartmental Unloader Brace for Patellofemoral or Multicompartment Knee Osteoarthritis. Front Bioeng Biotechnol 2021; 8:604860. [PMID: 33585409 PMCID: PMC7876241 DOI: 10.3389/fbioe.2020.604860] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Accepted: 12/15/2020] [Indexed: 11/13/2022] Open
Abstract
Objective: Off-loader knee braces have traditionally focused on redistributing loads away from either the medial or lateral tibiofemoral (TF) compartments. In this article, we study the potential of a novel "tricompartment unloader" (TCU) knee brace intended to simultaneously unload both the patellofemoral (PF) and TF joints during knee flexion. Three different models of the TCU brace are evaluated for their potential to unload the knee joint. Methods: A sagittal plane model of the knee was used to compute PF and TF contact forces, patellar and quadriceps tendon forces, and forces in the anterior and posterior cruciate ligaments during a deep knee bend (DKB) test using motion analysis data from eight participants. Forces were computed for the observed (no brace) and simulated braced conditions. A sensitivity and validity analysis was conducted to determine the valid output range for the model, and Statistical Parameter Mapping was used to quantify the effectual region of the different TCU brace models. Results: PF and TF joint force calculations were valid between ~0 and 100 degrees of flexion. All three simulated brace models significantly (p < 0.001) reduced predicted knee joint loads (by 30-50%) across all structures, at knee flexion angles >~30 degrees during DKB. Conclusions: The TCU brace is predicted to reduce PF and TF knee joint contact loads during weight-bearing activity requiring knee flexion angles between 30 and 100 degrees; this effect may be clinically beneficial for pain reduction or rehabilitation from common knee injuries or joint disorders. Future work is needed to assess the range of possible clinical and prophylactic benefits of the TCU brace.
Collapse
Affiliation(s)
- Chris A McGibbon
- Faculty of Kinesiology and Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
| | - Scott Brandon
- School of Engineering, University of Guelph, Guelph, ON, Canada
| | - Emily L Bishop
- Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary, AB, Canada
| | | | - Edmund N Biden
- Department of Mechanical Engineering and Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
| |
Collapse
|
9
|
McGibbon C, Sexton A, Gryfe P, Dutta T, Jayaraman A, Deems-Dluhy S, Novak A, Fabara E, Adans-Dester C, Bonato P. Effect of using of a lower-extremity exoskeleton on disability of people with multiple sclerosis. Disabil Rehabil Assist Technol 2021:1-8. [DOI: 10.1080/17483107.2021.1874064] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Affiliation(s)
- Chris McGibbon
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, Canada
- Faculty of Kinesiology, University of New Brunswick, Fredericton, Canada
| | - Andrew Sexton
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, Canada
| | - Pearl Gryfe
- Assistive Technology Clinic, Toronto, Canada
| | - Tilak Dutta
- Toronto Rehabilitation Institute, Toronto, Canada
| | - Arun Jayaraman
- Shirley Ryan AbilityLab/Rehabilitation Institute of Chicago, Chicago, IL, USA
| | - Susan Deems-Dluhy
- Shirley Ryan AbilityLab/Rehabilitation Institute of Chicago, Chicago, IL, USA
| | | | - Eric Fabara
- Department of Physical Medicine and Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Charlestown, MA, USA
| | - Catherine Adans-Dester
- Department of Physical Medicine and Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Charlestown, MA, USA
| | - Paolo Bonato
- Department of Physical Medicine and Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Charlestown, MA, USA
| |
Collapse
|
10
|
Zhu X, Chan YT, Yung PSH, Tuan RS, Jiang Y. Subchondral Bone Remodeling: A Therapeutic Target for Osteoarthritis. Front Cell Dev Biol 2021; 8:607764. [PMID: 33553146 PMCID: PMC7859330 DOI: 10.3389/fcell.2020.607764] [Citation(s) in RCA: 60] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 12/28/2020] [Indexed: 12/21/2022] Open
Abstract
There is emerging awareness that subchondral bone remodeling plays an important role in the development of osteoarthritis (OA). This review presents recent investigations on the cellular and molecular mechanism of subchondral bone remodeling, and summarizes the current interventions and potential therapeutic targets related to OA subchondral bone remodeling. The first part of this review covers key cells and molecular mediators involved in subchondral bone remodeling (osteoclasts, osteoblasts, osteocytes, bone extracellular matrix, vascularization, nerve innervation, and related signaling pathways). The second part of this review describes candidate treatments for OA subchondral bone remodeling, including the use of bone-acting reagents and the application of regenerative therapies. Currently available clinical OA therapies and known responses in subchondral bone remodeling are summarized as a basis for the investigation of potential therapeutic mediators.
Collapse
Affiliation(s)
- Xiaobo Zhu
- Institute for Tissue Engineering and Regenerative Medicine, The Chinese University of Hong Kong, Hong Kong, China.,Department of Orthopaedics & Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| | - Yau Tsz Chan
- Institute for Tissue Engineering and Regenerative Medicine, The Chinese University of Hong Kong, Hong Kong, China.,School of Biomedical Sciences, The Chinese University of Hong Kong, Hong Kong, China
| | - Patrick S H Yung
- Institute for Tissue Engineering and Regenerative Medicine, The Chinese University of Hong Kong, Hong Kong, China.,Department of Orthopaedics & Traumatology, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| | - Rocky S Tuan
- Institute for Tissue Engineering and Regenerative Medicine, The Chinese University of Hong Kong, Hong Kong, China.,School of Biomedical Sciences, The Chinese University of Hong Kong, Hong Kong, China
| | - Yangzi Jiang
- Institute for Tissue Engineering and Regenerative Medicine, The Chinese University of Hong Kong, Hong Kong, China.,School of Biomedical Sciences, The Chinese University of Hong Kong, Hong Kong, China
| |
Collapse
|
11
|
McGibbon CA, Sexton A, Jayaraman A, Deems-Dluhy S, Gryfe P, Novak A, Dutta T, Fabara E, Adans-Dester C, Bonato P. Evaluation of the Keeogo exoskeleton for assisting ambulatory activities in people with multiple sclerosis: an open-label, randomized, cross-over trial. J Neuroeng Rehabil 2018; 15:117. [PMID: 30541585 PMCID: PMC6291941 DOI: 10.1186/s12984-018-0468-6] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2018] [Accepted: 11/27/2018] [Indexed: 12/02/2022] Open
Abstract
Background Although physical activity and exercise is known to benefit people with multiple sclerosis (MS), the ability of these individuals to participate in such interventions is difficult due to the mobility impairments caused by the disease. Keeogo is a lower-extremity powered exoskeleton that may be a potential solution for enabling people with MS to benefit from physical activity and exercise. Methods An open-label, randomized, cross-over trial was used to examine the immediate performance effects when using the device, and the potential benefits of using the device in a home setting for 2 weeks. Clinical performance tests with and without the device included the 6 min walk test, timed up and go test and the 10-step stair test (up and down). An activity monitor was also used to measure physical activity at home, and a patient-reported questionnaire was used to determine the amount and extent of home use. Generalized linear models were used to test for trial effects, and correlation analysis used to examine relationships between trial effects and usage. Results Twenty-nine patients with MS participated. All measures showed small decrements in performance while wearing the device compared to not wearing the device. However, significant improvements in unassisted (Rehab effect) performance were found after using the device at home for 2 weeks, compared to 2 weeks at home without the device, and participants improved their ability to use the device over the trial period (Training effect). Rehab and Training effects were related to the self-reported extent that participants used Keeogo at home. Conclusions Keeogo appears to deliver an exercise-mediated benefit to individuals with MS that improved their unassisted gait endurance and stair climbing ability. Keeogo might be a useful tool for delivering physical activity interventions to individuals with mobility impairment due to MS. Trial registration ClinicalTrials.gov: NCT02904382. Registered 19 September 2016 - Retrospectively registered.
Collapse
Affiliation(s)
- Chris A McGibbon
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada. .,Faculty of Kinesiology, University of New Brunswick, Fredericton, NB, Canada.
| | - Andrew Sexton
- Institute of Biomedical Engineering, University of New Brunswick, Fredericton, NB, Canada
| | - Arun Jayaraman
- Shirley Ryan AbilityLab / Rehabilitation Institute of Chicago, Chicago, IL, USA
| | - Susan Deems-Dluhy
- Shirley Ryan AbilityLab / Rehabilitation Institute of Chicago, Chicago, IL, USA
| | - Pearl Gryfe
- Assistive Technology Clinic, Toronto, ON, Canada
| | - Alison Novak
- Toronto Rehabilitation Institute, Toronto, ON, Canada
| | - Tilak Dutta
- Toronto Rehabilitation Institute, Toronto, ON, Canada.,Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, ON, Canada
| | - Eric Fabara
- Department of Physical Medicine and Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Charlestown, MA, USA
| | - Catherine Adans-Dester
- Department of Physical Medicine and Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Charlestown, MA, USA
| | - Paolo Bonato
- Department of Physical Medicine and Rehabilitation, Harvard Medical School, Spaulding Rehabilitation Hospital, Charlestown, MA, USA
| |
Collapse
|