Obermayr S, Klasan A, Rasic L, Hauer G, Leitner L, Leithner A, Sadoghi P. Correlation of revision rate of unicompartmental knee arthroplasty with total knee arthroplasty: a meta-analysis of clinical studies and worldwide arthroplasty registers. Arch Orthop Trauma Surg 2024; 144:4873-4886. [PMID: 39404769 PMCID: PMC11582169 DOI: 10.1007/s00402-024-05574-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2024] [Accepted: 09/09/2024] [Indexed: 11/22/2024]
Abstract
INTRODUCTION The purpose of this study was to elucidate differences and similarities in revision rates amongst studies and national registers featuring total knee arthroplasty (TKA) and unicompartmental knee arthroplasty (UKA). Thereby comparability and reproducibility between study and register findings should be created. MATERIALS AND METHODS Clinical studies published between 2004 and September 2023 involving TKA or UKA were reviewed for total arthroplasty numbers, revision rates and demographic data. Findings were calculated as "revisions per 100 component years (CY)" and divided according to the nationality of the center. National arthroplasty registers were searched for numbers of arthroplasties and revisions alongside with demographic data. Revision rates in registers were compared to one another and comparison to revision rates from collected studies was drawn. RESULTS After evaluation, 98 studies and seven registers met our inclusion criteria and were included in this study. Cumulative percent revision rate in studies was 3.35% after a mean follow-up of 5.7 years, corresponding to 0.71 revisions per 100 CY for TKA and 7.67% after a mean follow-up of 4.9 years, corresponding to 1.3 revisions per 100 CY for UKA. Registers showed mean overall revision rates of 5.63% for TKA and 11.04% for UKA. CONCLUSIONS A positive correlation of revision rates of TKA and UKA in studies and registers was found, with overall revision rates of UKA comparted to TKA being 2.29 times higher in clinical studies and 1.96 times higher in registers. Revision rates in registers were 1.56 times higher than presented in clinical studies.
Collapse
Affiliation(s)
- Stephan Obermayr
- Department of Orthopedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Antonio Klasan
- AUVA UKH Steiermark, Graz, Austria
- Johannes Kepler University Linz, Linz, Austria
| | - Laura Rasic
- Department of Orthopedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Georg Hauer
- Department of Orthopedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Lukas Leitner
- Department of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), LMU University Hospital, Munich, Germany
| | - Andreas Leithner
- Department of Orthopedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria
| | - Patrick Sadoghi
- Department of Orthopedics and Trauma, Medical University of Graz, Auenbruggerplatz 5, 8036, Graz, Austria.
| |
Collapse
|
2
|
Breuer R, Fiala R, Hartenbach F, Pollok F, Huber T, Strasser-Kirchweger B, Rath B, Trieb K. Long term follow-up of a completely metal free total knee endoprosthesis in comparison to an identical metal counterpart. Sci Rep 2024; 14:20958. [PMID: 39251687 PMCID: PMC11384776 DOI: 10.1038/s41598-024-71256-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Accepted: 08/26/2024] [Indexed: 09/11/2024] Open
Abstract
Aseptic loosening is a feared and not yet fully-understood complication of total knee arthroplasty (TKA). Hypersensitivity reactions may be the underlying cause within some susceptible patients. Metal-free implants have been developed as a possible solution. The aim of this prospective, observational long-term study was the assessment of a completely metal-free ceramic knee replacement system compared to its identical metal counterpart 8 years after implantation, conducted as a follow-up of a previous report. A total of 88 patients (mean age 69 years) were enrolled in this prospective, observational long-term 8-year follow-up study. The "ceramic group" with a completely metal-free total knee replacement system was compared to the "conventional group" with an identical metal TKA system at the final follow-up. Clinical assessment included Knee Society Score (KSS), Oxford Knee Score (OKS), European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-L), European Quality of Life 5 Dimension Visual Analogue Scale (EQ-VAS) and High Activity Arthroplasty Score (HAAS) as well as perioperative or postoperative complications and need for revision. The tibial/femoral positioning, signs of periprosthetic fissures/fractures or radiolucent lines were documented radiographically. All postoperative clinical scores in the ceramic group primarily improved from baseline to 4-year follow-up, but then decreased at the final 8-year follow-up. At the final follow-up, statistically non-significant differences were found in comparison of both groups for the KSS (ceramic: 166 ± 31, conventional: 162 ± 29; p > 0.05), OKS (ceramic: 37, conventional: 39; p > 0.05), EQ-VAS (ceramic: 77 ± 17, conventional: 72 ± 18; p > 0.05), and HAAS (ceramic: 8.29 ± 3.32, conventional: 9.28 ± 4.44; p > 0.05). A significant difference was found for EQ-5D-L (ceramic: 0.819 ± 0.284, conventional: 0.932 ± 0.126; p ≤ 0.05). Progressive radiolucent lines have been found around the uncemented tibial stem (0.8 mm at initial diagnosis (mean 19 months); 1.3 mm at 4-year follow-up; 1.6 mm at 8-year follow-up) without any clinical signs of loosening. One revision surgery was performed after a traumatic polyethylene inlay-breakage. No allergic reactions could be detected. The used ceramic TKA system meets the functional performance standards of an established identical metal TKA system after an 8-year follow-up period, offering a safe option for patients with prior hypersensitivity reactions to metallic materials. Full cementation of ceramic components is recommended.
Collapse
Affiliation(s)
- Robert Breuer
- Department of Orthopedics and Trauma Surgery, Klinik Donaustadt, 1220, Vienna, Austria
| | - Rainer Fiala
- Department of Orthopedics and Trauma Surgery, Klinik Donaustadt, 1220, Vienna, Austria
| | - Florian Hartenbach
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | - Florian Pollok
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | - Thorsten Huber
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | | | - Bjoern Rath
- Department of Orthopedics, Klinikum Wels-Grieskirchen, 4600, Wels, Austria
| | - Klemens Trieb
- Department of Orthopedics, Paracelsus Medical University, 5020, Salzburg, Austria.
- Division for Orthopaedics and Traumatology, Center for Clinical Medicine, Danube Private University, 3500, Krems, Austria.
| |
Collapse
|
3
|
Xie F, Sheng S, Ram V, Pandit H. Hypoallergenic Knee Implant Usage and Clinical Outcomes: Are They Safe and Effective? Arthroplast Today 2024; 28:101399. [PMID: 39139362 PMCID: PMC11320431 DOI: 10.1016/j.artd.2024.101399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 03/24/2024] [Accepted: 04/03/2024] [Indexed: 08/15/2024] Open
Abstract
Background One of the most debated topics in modern total knee arthroplasty (TKA) is the impact of metal hypersensitivity (MH) as a potential cause of prosthesis failure. Implanting hypoallergenic prostheses to avoid potential problems in suspected cases of MH is one treatment option that can be used in such cases. However, their long-term clinical safety and efficacy are not well proven. Methods All literature relevant to modern hypoallergenic implants were reviewed and summarized to provide a comprehensive synopsis. In addition, a detailed literature search was performed on PUBMED, MEDLINE, and Google Scholar to identify all the clinical studies reporting outcomes for hypoallergenic knee implants. Our search was confined to those studies published as full manuscripts in the English language from July 2018 to July 2023. Results To minimize the risk of MH, new implant variants have been developed which are either under clinical evaluation or in routine clinical use. These include conventional metal implants with protective coatings (mono- or multilayer) and metal-free implants. However, there is insufficient clinical data to confirm the rationale and effectiveness of using these "hypoallergenic" TKA implants. Conclusions Published studies and arthroplasty registry data analyses indicate no significant differences between hypoallergenic and standard TKAs with overall good survival rates. In the future, further high-quality studies are needed to better understand the complexity of this subject.
Collapse
Affiliation(s)
- Feng Xie
- Department of Orthopedics, The Third Affiliated Hospital of Chongqing Medical University, Chongqing, China
| | - Shuya Sheng
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), University of Leeds, Leeds, UK
| | - Venkatesh Ram
- Chapel Allerton Hospital, C/O Leeds Teaching Hospitals NHS Trust, Leeds, UK
| | - Hemant Pandit
- Leeds Institute of Rheumatic and Musculoskeletal Medicine (LIRMM), University of Leeds, Leeds, UK
- Chapel Allerton Hospital, C/O Leeds Teaching Hospitals NHS Trust, Leeds, UK
| |
Collapse
|
4
|
Deroche E, Batailler C, Shatrov J, Gunst S, Servien E, Lustig S. No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study. SICOT J 2023; 9:5. [PMID: 36757220 PMCID: PMC9910165 DOI: 10.1051/sicotj/2023001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 01/05/2023] [Indexed: 02/10/2023] Open
Abstract
INTRODUCTION Nitride-based ceramic coating was introduced into surgical implants to improve hardness, reduce abrasion, and decrease the risk of metal-induced adverse reactions, especially for patients with suspected or identified metal hypersensitivity. The study aimed to evaluate the effectiveness and safety of a titanium nitride (TiN) coated prosthesis with a mobile bearing design. METHODS This was a retrospective matched-cohort study from a single center, comparing clinical outcomes between patients receiving either a TiN-coated versus an uncoated cobalt-chromium-molybdenum (CoCrMo) prostheses for primary total knee replacement. Seventeen patients received the TiN prosthesis between 2015 and 2019. These were matched 1:2 with patients receiving uncoated mobile-bearing knee prostheses with the same design manufacturer. RESULTS Fourteen patients in the TiN group had complete 5-year follow-up data and were compared with 34 patients from the CoCrMo group. The Knee Society Score was 170.6 ± 28.0 (Function subscore 83.7 ± 17.5 and Knee subscore 86.9 ± 13.8) in the TiN group and 180.7 ± 49.4 (Function subscore 87.5 ± 14.3 and Knee subscore 93.2 ± 9.6) in CoCrMo group, with no statistically significant difference (p = 0.19). One patient underwent a revision for instability requiring the removal of the implant in the TiN group and none in the CoCrMo group. The survival rates were 92.9% (CI95% 77.3-100.0) and 100.0% in the TiN group and CoCrMo group respectively (p = 1.0). DISCUSSION TiN-coated TKA with mobile bearing resulted in satisfactory clinical outcomes, and a low revision rate, and there was no complication related to the coated implant. The use of TiN-coated prostheses in case of confirmed or suspected metal allergy provides satisfactory short-term clinic outcomes.
Collapse
Affiliation(s)
- Etienne Deroche
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France,Corresponding author:
| | - Cécile Batailler
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France
| | - Jobe Shatrov
- Sydney Orthopaedic Research Institute (SORI) at Landmark Orthopaedics 500 Pacific Hwy St. Leonards NSW Australia
| | - Stanislas Gunst
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France
| | - Elvire Servien
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France,LIBM – EA 7424, Interuniversity Laboratory of Biology of Mobility, Claude Bernard Lyon 1 University 69622 Lyon France
| | - Sébastien Lustig
- Orthopaedic Surgery and Sports Medicine Department, FIFA Medical Center of Excellence, Croix-Rousse Hospital, Lyon University Hospital 69004 Lyon France,University of Lyon, Claude Bernard Lyon 1 University, IFSTTAR, LBMC UMR_T9406 69622 Lyon France
| |
Collapse
|
5
|
Lodge CJ, Matar HE, Berber R, Radford PJ, Bloch BV. Ceramic Coatings Confer No Survivorship Advantages in Total Knee Arthroplasty-A Single-Center Series of 1641 Knees. Arthroplast Today 2023; 19:101086. [PMID: 36688095 PMCID: PMC9851869 DOI: 10.1016/j.artd.2022.101086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 10/06/2022] [Accepted: 12/08/2022] [Indexed: 01/19/2023] Open
Abstract
Background Ceramic coatings in total knee arthroplasty have been introduced with the aim of reducing wear and consequently improving implant survivorship. We studied both cobalt-chrome-molybdenum (CoCrMo) and ceramic-coated components of the same implant design from a single center to identify if the ceramic coating conferred any benefit. Methods We identified 1641 Columbus total knee arthroplasties (Aesculap AG, Tüttlingen, Germany) from a prospectively collected arthroplasty database. Of the 1641, 983 were traditional CoCrMo, and 659 had the Columbus AS ceramic coating. Patients were followed up until death or revision of any component of the implant. Results There was no significant difference in implant survivorship using any component revision as the endpoint between the CoCrMo femur and the ceramic-coated femur at a mean of 9.2 years in follow-up for the CoCrMo group and 5 years for the ceramic-coated group (37 vs 14; P = .76). There was no reduction in the proportion of components revised for aseptic loosening or infection in the ceramic-coated cohort. Conclusions At midterm follow-up, there was no benefit in terms of implant survivorship in using a ceramic coating.
Collapse
Affiliation(s)
| | | | | | | | - Benjamin V. Bloch
- Corresponding author. Consultant Orthopaedic Surgeon, City Hospital Campus, Nottingham, NG5 1PB, UK. Tel.: +44 115 969 1169.
| |
Collapse
|
6
|
Bracey DN, Hegde V, Johnson R, Kleeman-Forsthuber L, Jennings J, Dennis D. Poor Correlation Among Metal Hypersensitivity Testing Modalities and Inferior Patient-Reported Outcomes After Primary and Revision Total Knee Arthroplasties. Arthroplast Today 2022; 18:138-142. [PMID: 36345325 PMCID: PMC9636001 DOI: 10.1016/j.artd.2022.09.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 09/16/2022] [Accepted: 09/22/2022] [Indexed: 11/06/2022] Open
Abstract
Background Metal allergy testing may influence clinical decision-making for patients undergoing a total knee arthroplasty (TKA). Limited data were found to examine the consistency of available testing modalities. This study compares different metal allergy test results and clinical outcomes after primary and revision TKAs in patients with and without metal hypersensitivity. Methods Primary (n = 28) and revision (n = 20) TKA patients receiving hypoallergenic implants for metal allergies diagnosed by skin patch testing (SPT), lymphocyte proliferation testing (LPT), or lymphocyte transformation testing (LTT) were retrospectively reviewed. The agreement between tests was assessed by percentage and kappa statistic within patients who used multiple testing modalities. Postoperative clinical outcomes of these patients were compared to those of patients without metal hypersensitivity matched by age (±5 years), body mass index (±5), gender, and follow-up duration (±2 years). Results SPT and LPT showed weak agreement for nickel and minimal agreement for cobalt. SPT and LTT showed minimal agreement for nickel; weak agreement for titanium, bone cement, vanadium, and zirconium; but strong agreement for chromium and cobalt. LPT and LTT agreement was weak. Compared to matched controls, metal hypersensitivity patients undergoing primary TKAs with hypoallergenic implants experienced less improvement in Knee Society Scores, Veterans RAND 12 physical component scores, and range of motion. Patients undergoing revision TKAs for multiple indications including metal hypersensitivity had worse clinical outcomes with significantly worse improvements in Knee Society functional scores compared to matched controls. Conclusions Metal allergy tests produce conflicting results. Hypersensitivity patients may experience inferior clinical outcomes even with hypoallergenic implants. Clinician awareness may influence the choice of testing and improve preoperative counseling of this patient population.
Collapse
Affiliation(s)
- Daniel N. Bracey
- Department of Orthopaedic Surgery, University of North Carolina, Chapel Hill, NC, USA
| | - Vishal Hegde
- Department of Orthopaedic Surgery, The Johns Hopkins University, Baltimore, MD, USA
| | | | | | - Jason Jennings
- Colorado Joint Replacement, Denver, CO, USA
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
- Corresponding author. Colorado Joint Replacement Centre, 2535 S. Downing Street, Suite 100, Denver, CO 80210. Tel.: +1 720 524 1367.
| | - Douglas Dennis
- Colorado Joint Replacement, Denver, CO, USA
- Department of Mechanical and Materials Engineering, University of Denver, Denver, CO, USA
- Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO, USA
- Department of Biomedical Engineering, University of Tennessee, Knoxville, TN, USA
| |
Collapse
|
7
|
Metal Allergy: State-of-the-Art Mechanisms, Biomarkers, Hypersensitivity to Implants. J Clin Med 2022; 11:jcm11236971. [PMID: 36498546 PMCID: PMC9739320 DOI: 10.3390/jcm11236971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 11/22/2022] [Accepted: 11/24/2022] [Indexed: 11/29/2022] Open
Abstract
Metal allergy is mainly an environmental disorder which can cause allergic contact dermatitis. Environmental metal exposures include jewelry, everyday metal items, mobile phones, leather, metal-rich food and implants, including stents or anchors. While consumer exposure is liable for the majority of metal hypersensitivity cases, the significance of occupational exposure to metals remains relevant. Although the most common metal allergens are nickel, chromium, and cobalt; however, lately, gold, palladium, titanium, and some others have also attracted attention. This review highlights advances in metal allergy mechanisms, biomarkers for potential patients' stratification as well as biological treatments. The most recent evidence of human exposure to metal for risk assessment is discussed, as well as the relationship between the occurrence of metal hypersensitivity and implanted devices, including non-characteristic symptoms. The latest data on the diagnosis of metal hypersensitivity are also reported.
Collapse
|
8
|
Matar HE, Porter PJ, Porter ML. Metal allergy in primary and revision total knee arthroplasty : a scoping review and evidence-based practical approach. Bone Jt Open 2021; 2:785-795. [PMID: 34587776 PMCID: PMC8558451 DOI: 10.1302/2633-1462.210.bjo-2021-0098.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
AIMS Metal allergy in knee arthroplasty patients is a controversial topic. We aimed to conduct a scoping review to clarify the management of metal allergy in primary and revision total knee arthroplasty (TKA). METHODS Studies were identified by searching electronic databases: Cochrane Central Register of Controlled Trials, Ovid MEDLINE, and Embase, from their inception to November 2020, for studies evaluating TKA patients with metal hypersensitivity/allergy. All studies reporting on diagnosing or managing metal hypersensitivity in TKA were included. Data were extracted and summarized based on study design, study population, interventions and outcomes. A practical guide is then formulated based on the available evidence. RESULTS We included 38 heterogeneous studies (two randomized controlled trials, six comparative studies, 19 case series, and 11 case reports). The evidence indicates that metal hypersensitivity is a rare complication with some histopathological features leading to pain and dissatisfaction with no reliable screening tests preoperatively. Hypoallergenic implants are viable alternatives for patients with self-reported/confirmed metal hypersensitivity if declared preoperatively; however, concerns remain over their long-term outcomes with ceramic implants outperforming titanium nitride-coated implants and informed consent is paramount. For patients presenting with painful TKA, metal hypersensitivity is a diagnosis of exclusion where patch skin testing, lymphocyte transformation test, and synovial biopsies are useful adjuncts before revision surgery is undertaken to hypoallergenic implants with shared decision-making and informed consent. CONCLUSION Using the limited available evidence in the literature, we provide a practical approach to metal hypersensitivity in TKA patients. Future national/registry-based studies are needed to identify the scale of metal hypersensitivity, agreed diagnostic criteria, and management strategies. Cite this article: Bone Jt Open 2021;2(10):785-795.
Collapse
Affiliation(s)
- Hosam E. Matar
- Wrightington Hospital, Wigan, UK
- Nottingham Elective Orthopaedic Services, Nottingham University Hospital NHS Trust, Nottingham, UK
| | | | | |