1
|
Gesley M, Puri R. A high throughput spectral image microscopy system. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:013705. [PMID: 29390702 DOI: 10.1063/1.4998725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A high throughput spectral image microscopy system is configured for rapid detection of rare cells in large populations. To overcome flow cytometry rates and use of fluorophore tags, a system architecture integrates sample mechanical handling, signal processors, and optics in a non-confocal version of light absorption and scattering spectroscopic microscopy. Spectral images with native contrast do not require the use of exogeneous stain to render cells with submicron resolution. Structure may be characterized without restriction to cell clusters of differentiation.
Collapse
Affiliation(s)
- M Gesley
- Spynsite LLC, 31 Rydal Court, Oakland, California 94611, USA
| | - R Puri
- Spynsite LLC, 31 Rydal Court, Oakland, California 94611, USA
| |
Collapse
|
2
|
Yu Y, Xiao C, Chen K, Zheng J, Zhang J, Zhao X, Xue X. Different optical properties between human hepatocellular carcinoma tissues and non-tumorous hepatic tissues in vitro. ACTA ACUST UNITED AC 2011; 31:515. [PMID: 21823014 DOI: 10.1007/s11596-011-0482-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2010] [Indexed: 10/17/2022]
Abstract
There has been an ongoing search for clinically acceptable methods for the accurate, efficient and simple diagnosis and prognosis of hepatocellular carcinoma (HCC). Optical spectroscopy is a technique with potential clinical applications to diagnose cancer diseases. The purpose of this study was to obtain the optical properties of HCC tissues and non-tumorous hepatic tissues and identify the difference between them. A total of 55 tissue samples (HCC tissue, n=38; non-tumorous hepatic tissue, n=17) were surgically resected from patients with HCC. The optical parameters were measured in 10-nm steps using single-integrating-sphere system in the wavelength range of 400 to 1800 nm. It was found that the optical properties and their differences varied with the wavelength for the HCC tissue and the non-tumorous hepatic tissue in the entire wavelength range of research. The absorption coefficient of the HCC tissue (1.48±0.99, 1.46±0.88, 0.86±0.61, 2.15±0.53, 0.54±0.10, 0.79±0.15 mm(-1)) was significantly lower than that of the non-tumorous hepatic tissue (2.79±1.73, 3.13±1.47, 3.06±2.79, 2.57±0.55, 0.62±0.10, 0.93±0.16 mm(-1)) at wavelengths of 400, 410, 450, 1450, 1660 and 1800 nm, respectively (P<0.05). The reduced scattering coefficient of HCC tissue (5.28±1.70, 4.91±1.54, 1.26±0.35 mm(-1)) and non-tumorous hepatic tissue (8.14±3.70, 9.27±3.08, 2.55±0.57 mm(-1)) was significantly different at 460, 500 and 1800 nm respectively (P<0.05). These results show different pathologic liver tissues have different optical properties. It provides a better understanding of the relationship between optical parameters and physiological characteristics in human liver tissues. And it would be very useful for developing a non-invasive, real-time, simple and efficient way for medical management of HCC in the future.
Collapse
Affiliation(s)
- Yuan Yu
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Chaowen Xiao
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Kun Chen
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Jianwei Zheng
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Jun Zhang
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Xinyang Zhao
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China
| | - Xinbo Xue
- Department of Biliary and Pancreatic Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China.
| |
Collapse
|
3
|
Klossa J, Daliphard S, Troussard X, Vielh P, Manfait M, Angulo J, Flandrin G, Beljebbar A, Untereiner V, Happillon T, Gobinet C, Velasco-Forero S, Roux S, Saada V, Dagiral R, Coomans V, Froigneux E, Rideau P, Vievard A. La biophotonique au service de l’identification de marqueurs pronostiques intracellulaires. Ing Rech Biomed 2011. [DOI: 10.1016/j.irbm.2011.01.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
Zucker RM, Rigby P, Clements I, Salmon W, Chua M. Reliability of confocal microscopy spectral imaging systems: Use of multispectral beads. Cytometry A 2007; 71:174-89. [PMID: 17266146 DOI: 10.1002/cyto.a.20371] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND There is a need for a standardized, impartial calibration, and validation protocol on confocal spectral imaging (CSI) microscope systems. To achieve this goal, it is necessary to have testing tools to provide a reproducible way to evaluate instrument performance. METHODS We evaluated fluorescent spectral beads (FocalCheck) from Molecular Probes/Invitrogen that consist of four pairs with emissions between 500 and 725 nm and a europium macrocycle quantum dye bead. These bead tools compliment our previously published protocol for testing spectral imaging systems that used an inexpensive multi-ion discharge lamp (MIDL) that contains Hg(+), Ar(+), and inorganic fluorophores that emits distinct, stable spectral features. RESULTS We acquired the spectra of the FocalCheck beads on a Zeiss 510 Meta, a Leica TCS-SP1, a Leica SP2 AOBS, an Olympus FV 1000, and a Nikon C1Si confocal systems and a PARISS microscopic spectral system and of the europium beads on the Leica TCS-SP1 and PARISS spectral imaging systems. A lack of performance with some equipment between 650 and 750 nm was identified using the far red pair of the FocalCheck beads. The position of the slider in front of PMT 2 that reflects light into PMT 1 and PMT 3 affected the measurement of all bead intensities. Unmixing algorithms were used to separate beads with different fluorochromes and separate two fluorochromes on the same bead. CONCLUSIONS The FocalCheck multi-spectral beads yielded similar profiles on four CSI systems and a PARISS spectral system. The utilization of the spectral FocalCheck beads is helpful to evaluate proper spectral performance, especially in the far red region. Europium beads provide a very narrow spectrum that can help to identify machines that have spectral problems. The dyes located on individual beads or mixed together in ring-core configuration can be used as test particles to demonstrate spectral unmixing with various algorithms.
Collapse
Affiliation(s)
- Robert M Zucker
- Reproductive Toxicology Division (MD-67), National Health and Environmental Effects Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27711, USA. zucker.robert@.epa.gov
| | | | | | | | | |
Collapse
|
5
|
Zucker RM, Jeffay SC. Confocal laser scanning microscopy of whole mouse ovaries: excellent morphology, apoptosis detection, and spectroscopy. Cytometry A 2006; 69:930-9. [PMID: 16969804 DOI: 10.1002/cyto.a.20315] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Ovaries consist of numerous follicles, oocytes, and granulosa cells in different stages of development. Many of these follicles will undergo an apoptotic process during the lifetime of the animal. By using proper tissue preparation methods, the events within the whole ovary can be observed by using 3D confocal microscopy. METHODS Whole ovaries were stained with LysoTracker Red (LT), fixed with 4% paraformaldehyde (PF) and 1% glutaraldehyde (Glut), dehydrated with methanol (MEOH), and cleared with benzyl alcohol and benzyl benzoate (BABB). Using this tissue preparation technique, the ovary becomes relatively transparent, allowing its morphology to be observed with confocal microscopes. A spectral imaging system (PARISS) located on a conventional microscope was used to interpret the LT dye spectra and fixation products in the tissues with different excitation wavelengths. RESULTS Apoptosis in the follicle was detected as clusters of intensely stained granulosa cells located in close proximity to the oocytes. The fixation with Glut and PF preserved morphological details, increased tissue fluorescence, thus increased the signal to noise of the background image. CONCLUSIONS Thick tissues can be imaged after they are properly stained, aldehyde fixed, and BABB cleared. LT intensely stained single cells or clusters of apoptotic cells in the follicles and the nucleolus. Spectral differences between LT as an indicator of apoptosis and Glut-PF fixation was used to visualize ovarian morphology and apoptosis. The PARISS spectrophotometer revealed spectral peaks for LT at 609.6 nm and for Glut-PF at 471.3 nm. The proper use of the spectra from these fluorescence molecules is the foundation for high quality morphological images of apoptosis. By sequentially imaging the two probes with a 488 nm laser and a 543/568 nm laser, there was a reduction in fluorescent cross talk and an increase in image quality.
Collapse
Affiliation(s)
- Robert M Zucker
- National Health and Environmental Effects Research Laboratory, Reproductive Toxicology Division, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, USA.
| | | |
Collapse
|