1
|
Canales-Rodríguez EJ, Pizzolato M, Zhou FL, Barakovic M, Thiran JP, Jones DK, Parker GJM, Dyrby TB. Pore size estimation in axon-mimicking microfibers with diffusion-relaxation MRI. Magn Reson Med 2024; 91:2579-2596. [PMID: 38192108 DOI: 10.1002/mrm.29991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 12/04/2023] [Accepted: 12/12/2023] [Indexed: 01/10/2024]
Abstract
PURPOSE This study aims to evaluate two distinct approaches for fiber radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfiber phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. THEORY AND METHODS A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from scanning electron microscope images. RESULTS Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, although some discrepancies were observed. The spherical mean power-law method overestimated fiber radii. Conversely, the T2-based method exhibited higher sensitivity to smaller fiber radii, but faced limitations in accurately estimating the radius in one particular phantom, possibly because of material-specific relaxation changes. CONCLUSION The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibers. The T2-based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients, but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fiber radius estimation, highlights the advantages and limitations of both methods, and provides datasets for reproducible research.
Collapse
Affiliation(s)
- Erick J Canales-Rodríguez
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
| | - Marco Pizzolato
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
- Department of Applied Mathematics and Computer Science, Technical University of Denmark (DTU), Kongens Lyngby, Denmark
| | - Feng-Lei Zhou
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London (UCL), London, UK
- MicroPhantoms Limited, Cambridge, UK
| | - Muhamed Barakovic
- Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland
| | - Jean-Philippe Thiran
- Signal Processing Laboratory 5 (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois and University of Lausanne, Lausanne, Switzerland
- Centre d'Imagerie Biomédicale (CIBM), EPFL, Lausanne, Switzerland
| | - Derek K Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, UK
| | - Geoffrey J M Parker
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London (UCL), London, UK
- Department of Neuroinflammation, Queen Square Institute of Neurology, University College London (UCL), London, UK
- Bioxydyn Limited, Manchester, UK
| | - Tim B Dyrby
- Danish Research Centre for Magnetic Resonance (DRCMR), Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark
- Department of Applied Mathematics and Computer Science, Technical University of Denmark (DTU), Kongens Lyngby, Denmark
| |
Collapse
|
2
|
Villarreal-Haro JL, Gardier R, Canales-Rodríguez EJ, Fischi-Gomez E, Girard G, Thiran JP, Rafael-Patiño J. CACTUS: a computational framework for generating realistic white matter microstructure substrates. Front Neuroinform 2023; 17:1208073. [PMID: 37603781 PMCID: PMC10434236 DOI: 10.3389/fninf.2023.1208073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/13/2023] [Indexed: 08/23/2023] Open
Abstract
Monte-Carlo diffusion simulations are a powerful tool for validating tissue microstructure models by generating synthetic diffusion-weighted magnetic resonance images (DW-MRI) in controlled environments. This is fundamental for understanding the link between micrometre-scale tissue properties and DW-MRI signals measured at the millimetre-scale, optimizing acquisition protocols to target microstructure properties of interest, and exploring the robustness and accuracy of estimation methods. However, accurate simulations require substrates that reflect the main microstructural features of the studied tissue. To address this challenge, we introduce a novel computational workflow, CACTUS (Computational Axonal Configurator for Tailored and Ultradense Substrates), for generating synthetic white matter substrates. Our approach allows constructing substrates with higher packing density than existing methods, up to 95% intra-axonal volume fraction, and larger voxel sizes of up to 500μm3 with rich fibre complexity. CACTUS generates bundles with angular dispersion, bundle crossings, and variations along the fibres of their inner and outer radii and g-ratio. We achieve this by introducing a novel global cost function and a fibre radial growth approach that allows substrates to match predefined targeted characteristics and mirror those reported in histological studies. CACTUS improves the development of complex synthetic substrates, paving the way for future applications in microstructure imaging.
Collapse
Affiliation(s)
- Juan Luis Villarreal-Haro
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
| | - Remy Gardier
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
| | - Erick J. Canales-Rodríguez
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
| | - Elda Fischi-Gomez
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| | - Gabriel Girard
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
- Department of Computer Science, University of Sherbrooke, Sherbrooke, QC, Canada
| | - Jean-Philippe Thiran
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- CIBM Center for Biomedical Imaging, Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| | - Jonathan Rafael-Patiño
- Signal Processing Laboratory (LTS5), École Polytechnique Frale de Lausanne (EPFL), Lausanne, Switzerland
- Radiology Department, Centre Hospitalier Universitaire Vaudois, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
3
|
Hu C, Grech‐Sollars M, Statton B, Li Z, Gao F, Williams GR, Parker GJM, Zhou F. Direct jet coaxial electrospinning of axon-mimicking fibers for diffusion tensor imaging. POLYM ADVAN TECHNOL 2023; 34:2573-2584. [PMID: 38505514 PMCID: PMC10946859 DOI: 10.1002/pat.6073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2023] [Revised: 04/01/2023] [Accepted: 04/16/2023] [Indexed: 03/21/2024]
Abstract
Hollow polymer microfibers with variable microstructural and hydrophilic properties were proposed as building elements to create axon-mimicking phantoms for validation of diffusion tensor imaging (DTI). The axon-mimicking microfibers were fabricated in a mm-thick 3D anisotropic fiber strip, by direct jet coaxial electrospinning of PCL/polysiloxane-based surfactant (PSi) mixture as shell and polyethylene oxide (PEO) as core. Hydrophilic PCL-PSi fiber strips were first obtained by carefully selecting appropriate solvents for the core and appropriate fiber collector rotating and transverse speeds. The porous cross-section and anisotropic orientation of axon-mimicking fibers were then quantitatively evaluated using two ImageJ plugins-nearest distance (ND) and directionality based on their scanning electron microscopy (SEM) images. Third, axon-mimicking phantom was constructed from PCL-PSi fiber strips with variable porous-section and fiber orientation and tested on a 3T clinical MR scanner. The relationship between DTI measurements (mean diffusivity [MD] and fractional anisotropy [FA]) of phantom samples and their pore size and fiber orientation was investigated. Two key microstructural parameters of axon-mimicking phantoms including normalized pore distance and dispersion of fiber orientation could well interpret the variations in DTI measurements. Two PCL-PSi phantom samples made from different regions of the same fiber strips were found to have similar MD and FA values, indicating that the direct jet coaxial electrospun fiber strips had consistent microstructure. More importantly, the MD and FA values of the developed axon-mimicking phantoms were mostly in the biologically relevant range.
Collapse
Affiliation(s)
- Chunyan Hu
- College of Textiles and ClothingQingdao UniversityQingdaoChina
| | - Matthew Grech‐Sollars
- Department of Computer ScienceUniversity College LondonLondonUK
- Lysholm Department of Neuroradiology, National Hospital for Neurology and NeurosurgeryUniversity College London Hospitals NHS Foundation TrustLondonUK
| | - Ben Statton
- Medical Research Council, London Institute of Medical SciencesImperial College LondonLondonUK
| | - Zhanxiong Li
- College of Textile and Clothing EngineeringSoochow UniversitySuzhouChina
| | - Fei Gao
- Department of Radiology, Shandong Provincial Hospital, Cheeloo College of MedicineShandong UniversityJinanChina
| | | | - Geoff J. M. Parker
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
- Bioxydyn LimitedManchesterUK
| | - Feng‐Lei Zhou
- College of Textiles and ClothingQingdao UniversityQingdaoChina
- School of PharmacyUniversity College LondonLondonUK
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical EngineeringUniversity College LondonLondonUK
| |
Collapse
|
4
|
Teh I, Shelley D, Boyle JH, Zhou F, Poenar A, Sharrack N, Foster RJ, Yuldasheva NY, Parker GJM, Dall'Armellina E, Plein S, Schneider JE, Szczepankiewicz F. Cardiac q-space trajectory imaging by motion-compensated tensor-valued diffusion encoding in human heart in vivo. Magn Reson Med 2023; 90:150-165. [PMID: 36941736 PMCID: PMC10952623 DOI: 10.1002/mrm.29637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 01/25/2023] [Accepted: 02/23/2023] [Indexed: 03/23/2023]
Abstract
PURPOSE Tensor-valued diffusion encoding can probe more specific features of tissue microstructure than what is available by conventional diffusion weighting. In this work, we investigate the technical feasibility of tensor-valued diffusion encoding at high b-values with q-space trajectory imaging (QTI) analysis, in the human heart in vivo. METHODS Ten healthy volunteers were scanned on a 3T scanner. We designed time-optimal gradient waveforms for tensor-valued diffusion encoding (linear and planar) with second-order motion compensation. Data were analyzed with QTI. Normal values and repeatability were investigated for the mean diffusivity (MD), fractional anisotropy (FA), microscopic FA (μFA), isotropic, anisotropic and total mean kurtosis (MKi, MKa, and MKt), and orientation coherence (Cc ). A phantom, consisting of two fiber blocks at adjustable angles, was used to evaluate sensitivity of parameters to orientation dispersion and diffusion time. RESULTS QTI data in the left ventricular myocardium were MD = 1.62 ± 0.07 μm2 /ms, FA = 0.31 ± 0.03, μFA = 0.43 ± 0.07, MKa = 0.20 ± 0.07, MKi = 0.13 ± 0.03, MKt = 0.33 ± 0.09, and Cc = 0.56 ± 0.22 (mean ± SD across subjects). Phantom experiments showed that FA depends on orientation dispersion, whereas μFA was insensitive to this effect. CONCLUSION We demonstrated the first tensor-valued diffusion encoding and QTI analysis in the heart in vivo, along with first measurements of myocardial μFA, MKi, MKa, and Cc . The methodology is technically feasible and provides promising novel biomarkers for myocardial tissue characterization.
Collapse
Affiliation(s)
- Irvin Teh
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - David Shelley
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
- Leeds Teaching Hospitals TrustLeedsUK
| | - Jordan H. Boyle
- Faculty of Industrial Design EngineeringDelft University of TechnologyDelftNetherlands
| | - Fenglei Zhou
- Center for Medical Image Computing, Department of Medical Physics & Biomedical Engineering and Department of NeuroinflammationUniversity College LondonLondonUK
- Astrea BioseparationCombertonUK
| | - Ana‐Maria Poenar
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Noor Sharrack
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Richard J. Foster
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Nadira Y. Yuldasheva
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Geoff J. M. Parker
- Center for Medical Image Computing, Department of Medical Physics & Biomedical Engineering and Department of NeuroinflammationUniversity College LondonLondonUK
- Bioxydyn LimitedManchesterUK
| | - Erica Dall'Armellina
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Jürgen E. Schneider
- Leeds Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | | |
Collapse
|
5
|
Drobnjak I, Neher P, Poupon C, Sarwar T. Physical and digital phantoms for validating tractography and assessing artifacts. Neuroimage 2021; 245:118704. [PMID: 34748954 DOI: 10.1016/j.neuroimage.2021.118704] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 10/01/2021] [Accepted: 11/01/2021] [Indexed: 11/17/2022] Open
Abstract
Fiber tractography is widely used to non-invasively map white-matter bundles in vivo using diffusion-weighted magnetic resonance imaging (dMRI). As it is the case for all scientific methods, proper validation is a key prerequisite for the successful application of fiber tractography, be it in the area of basic neuroscience or in a clinical setting. It is well-known that the indirect estimation of the fiber tracts from the local diffusion signal is highly ambiguous and extremely challenging. Furthermore, the validation of fiber tractography methods is hampered by the lack of a real ground truth, which is caused by the extremely complex brain microstructure that is not directly observable non-invasively and that is the basis of the huge network of long-range fiber connections in the brain that are the actual target of fiber tractography methods. As a substitute for in vivo data with a real ground truth that could be used for validation, a widely and successfully employed approach is the use of synthetic phantoms. In this work, we are providing an overview of the state-of-the-art in the area of physical and digital phantoms, answering the following guiding questions: "What are dMRI phantoms and what are they good for?", "What would the ideal phantom for validation fiber tractography look like?" and "What phantoms, phantom datasets and tools used for their creation are available to the research community?". We will further discuss the limitations and opportunities that come with the use of dMRI phantoms, and what future direction this field of research might take.
Collapse
Affiliation(s)
- Ivana Drobnjak
- Center for Medical Image Computing, Department of Computer Science, University College London, UK.
| | - Peter Neher
- Division of Medical Image Computing, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Cyril Poupon
- BAOBAB, NeuroSpin, Commissariat à l'Energie Atomique, Institut des Sciences du Vivant Frédéric Joliot, Gif-sur-Yvette, France
| | - Tabinda Sarwar
- School of Computing Technologies, RMIT University, Australia
| |
Collapse
|
6
|
Huang CC, Hsu CCH, Zhou FL, Kusmia S, Drakesmith M, Parker GJM, Lin CP, Jones DK. Validating pore size estimates in a complex microfiber environment on a human MRI system. Magn Reson Med 2021; 86:1514-1530. [PMID: 33960501 PMCID: PMC7613441 DOI: 10.1002/mrm.28810] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Revised: 03/18/2021] [Accepted: 03/26/2021] [Indexed: 12/19/2022]
Abstract
PURPOSE Recent advances in diffusion-weighted MRI provide "restricted diffusion signal fraction" and restricting pore size estimates. Materials based on co-electrospun oriented hollow cylinders have been introduced to provide validation for such methods. This study extends this work, exploring accuracy and repeatability using an extended acquisition on a 300 mT/m gradient human MRI scanner, in substrates closely mimicking tissue, that is, non-circular cross-sections, intra-voxel fiber crossing, intra-voxel distributions of pore-sizes, and smaller pore-sizes overall. METHODS In a single-blind experiment, diffusion-weighted data were collected from a biomimetic phantom on a 3T Connectom system using multiple gradient directions/diffusion times. Repeated scans established short-term and long-term repeatability. The total scan time (54 min) matched similar protocols used in human studies. The number of distinct fiber populations was estimated using spherical deconvolution, and median pore size estimated through the combination of CHARMED and AxCaliber3D framework. Diffusion-based estimates were compared with measurements derived from scanning electron microscopy. RESULTS The phantom contained substrates with different orientations, fiber configurations, and pore size distributions. Irrespective of one or two populations within the voxel, the pore-size estimates (~5 μm) and orientation-estimates showed excellent agreement with the median values of pore-size derived from scanning electron microscope and phantom configuration. Measurement repeatability depended on substrate complexity, with lower values seen in samples containing crossing-fibers. Sample-level repeatability was found to be good. CONCLUSION While no phantom mimics tissue completely, this study takes a step closer to validating diffusion microstructure measurements for use in vivo by demonstrating the ability to quantify microgeometry in relatively complex configurations.
Collapse
Affiliation(s)
- Chu-Chung Huang
- Key Laboratory of Brain Functional Genomics (MOE & STCSM), Affiliated Mental Health Center (ECNU), Institute of Cognitive Neuroscience, School of Psychology and Cognitive Science, East China Normal University, Shanghai, China
- Shanghai Changning Mental Health Center, Shanghai, China
| | - Chih-Chin Heather Hsu
- Center for Geriatrics and Gerontology, Taipei Veterans General Hospital, Taipei, Taiwan
- Institute of Neuroscience, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Feng-Lei Zhou
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, United Kingdom
- School of Pharmacy, University College London, London, United Kingdom
| | - Slawomir Kusmia
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, United Kingdom
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
- Epilepsy Society MRI Unit, Chalfont St Peter, United Kingdom
| | - Mark Drakesmith
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
| | - Geoff J. M. Parker
- Centre for Medical Image Computing, Department of Computer Science, University College London, London, United Kingdom
- Department of Neuroinflammation, Queen Square Institute of Neurology, University College London, London, United Kingdom
- Bioxydyn Limited, Manchester, United Kingdom
| | - Ching-Po Lin
- Institute of Neuroscience, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Derek K. Jones
- Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, United Kingdom
| |
Collapse
|
7
|
Kerkelä L, Nery F, Callaghan R, Zhou F, Gyori NG, Szczepankiewicz F, Palombo M, Parker GJM, Zhang H, Hall MG, Clark CA. Comparative analysis of signal models for microscopic fractional anisotropy estimation using q-space trajectory encoding. Neuroimage 2021; 242:118445. [PMID: 34375753 DOI: 10.1016/j.neuroimage.2021.118445] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 07/06/2021] [Accepted: 08/02/2021] [Indexed: 12/12/2022] Open
Abstract
Microscopic diffusion anisotropy imaging using diffusion-weighted MRI and multidimensional diffusion encoding is a promising method for quantifying clinically and scientifically relevant microstructural properties of neural tissue. Several methods for estimating microscopic fractional anisotropy (µFA), a normalized measure of microscopic diffusion anisotropy, have been introduced but the differences between the methods have received little attention thus far. In this study, the accuracy and precision of µFA estimation using q-space trajectory encoding and different signal models were assessed using imaging experiments and simulations. Three healthy volunteers and a microfibre phantom were imaged with five non-zero b-values and gradient waveforms encoding linear and spherical b-tensors. Since the ground-truth µFA was unknown in the imaging experiments, Monte Carlo random walk simulations were performed using axon-mimicking fibres for which the ground truth was known. Furthermore, parameter bias due to time-dependent diffusion was quantified by repeating the simulations with tuned waveforms, which have similar power spectra, and with triple diffusion encoding, which, unlike q-space trajectory encoding, is not based on the assumption of time-independent diffusion. The truncated cumulant expansion of the powder-averaged signal, gamma-distributed diffusivities assumption, and q-space trajectory imaging, a generalization of the truncated cumulant expansion to individual signals, were used to estimate µFA. The gamma-distributed diffusivities assumption consistently resulted in greater µFA values than the second order cumulant expansion, 0.1 greater when averaged over the whole brain. In the simulations, the generalized cumulant expansion provided the most accurate estimates. Importantly, although time-dependent diffusion caused significant overestimation of µFA using all the studied methods, the simulations suggest that the resulting bias in µFA is less than 0.1 in human white matter.
Collapse
Affiliation(s)
- Leevi Kerkelä
- UCL Great Ormond Street Institute of Child Health, University College London, London, UK.
| | - Fabio Nery
- UCL Great Ormond Street Institute of Child Health, University College London, London, UK
| | - Ross Callaghan
- UCL Centre for Medical Image Computing, University College London, London, UK
| | - Fenglei Zhou
- UCL Centre for Medical Image Computing, University College London, London, UK; UCL School of Pharmacy, University College London, London, UK
| | - Noemi G Gyori
- UCL Centre for Medical Image Computing, University College London, London, UK; UCL Great Ormond Street Institute of Child Health, University College London, London, UK
| | - Filip Szczepankiewicz
- Department of Radiology, Brigham and Women's Hospital, Boston, Massachusetts, US; Harvard Medical School, Boston, Massachusetts, US; Clinical Sciences Lund, Lund University, Lund, Sweden
| | - Marco Palombo
- UCL Centre for Medical Image Computing, University College London, London, UK
| | - Geoff J M Parker
- UCL Centre for Medical Image Computing, University College London, London, UK; Bioxydyn Limited, Manchester, UK; UCL Queen Square Institute of Neurology, University College London, London, UK
| | - Hui Zhang
- UCL Centre for Medical Image Computing, University College London, London, UK
| | - Matt G Hall
- UCL Great Ormond Street Institute of Child Health, University College London, London, UK; National Physical Laboratory, Teddington, UK
| | - Chris A Clark
- UCL Great Ormond Street Institute of Child Health, University College London, London, UK
| |
Collapse
|
8
|
Zhou FL, McHugh DJ, Li Z, Gough JE, Williams GR, Parker GJM. Coaxial electrospun biomimetic copolymer fibres for application in diffusion magnetic resonance imaging. BIOINSPIRATION & BIOMIMETICS 2021; 16:046016. [PMID: 33706299 DOI: 10.1088/1748-3190/abedcf] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Accepted: 03/11/2021] [Indexed: 06/12/2023]
Abstract
Objective. The use of diffusion magnetic resonance imaging (dMRI) opens the door to characterizing brain microstructure because water diffusion is anisotropic in axonal fibres in brain white matter and is sensitive to tissue microstructural changes. As dMRI becomes more sophisticated and microstructurally informative, it has become increasingly important to use a reference object (usually called an imaging phantom) for validation of dMRI. This study aims to develop axon-mimicking physical phantoms from biocopolymers and assess their feasibility for validating dMRI measurements.Approach. We employed a simple and one-step method-coaxial electrospinning-to prepare axon-mimicking hollow microfibres from polycaprolactone-b-polyethylene glycol (PCL-b-PEG) and poly(D, L-lactide-co-glycolic) acid (PLGA), and used them as building elements to create axon-mimicking phantoms. Electrospinning was firstly conducted using two types of PCL-b-PEG and two types of PLGA with different molecular weights in various solvents, with different polymer concentrations, for determining their spinnability. Polymer/solvent concentration combinations with good fibre spinnability were used as the shell material in the following co-electrospinning process in which the polyethylene oxide polymer was used as the core material. Following the microstructural characterization of both electrospun and co-electrospun fibres using optical and electron microscopy, two prototype phantoms were constructed from co-electrospun anisotropic hollow microfibres after inserting them into water-filled test tubes.Main results. Hollow microfibres that mimic the axon microstructure were successfully prepared from the appropriate core and shell material combinations. dMRI measurements of two phantoms on a 7 tesla (T) pre-clinical scanner revealed that diffusivity and anisotropy measurements are in the range of brain white matter.Significance. This feasibility study showed that co-electrospun PCL-b-PEG and PLGA microfibre-based axon-mimicking phantoms could be used in the validation of dMRI methods which seek to characterize white matter microstructure.
Collapse
Affiliation(s)
- Feng-Lei Zhou
- Centre for Medical Image Computing, Department of Computer Science, University College London, London WC1V 6LJ, United Kingdom
- UCL School of Pharmacy, University College London, London WC1N 1AX, United Kingdom
| | - Damien J McHugh
- Quantitative Biomedical Imaging Laboratory, The University of Manchester, Manchester M13 9PL, United Kingdom
| | - Zhanxiong Li
- College of Textile and Clothing Engineering, Soochow University, Suzhou 215021, People's Republic of China
| | - Julie E Gough
- Department of Materials and Henry Royce Institute, The University of Manchester, Manchester M13 9PL, United Kingdom
| | - Gareth R Williams
- UCL School of Pharmacy, University College London, London WC1N 1AX, United Kingdom
| | - Geoff J M Parker
- Centre for Medical Image Computing, Department of Computer Science, University College London, London WC1V 6LJ, United Kingdom
- Bioxydyn Limited, Manchester, United Kingdom
| |
Collapse
|
9
|
Zhang C, Ding Q, He H, Peng Y, Li C, Mai J, Li JS, Zhong J, Chang MW. Nanoporous hollow fibers as a phantom material for the validation of diffusion magnetic resonance imaging. J Appl Polym Sci 2019. [DOI: 10.1002/app.47617] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Affiliation(s)
- Chunchen Zhang
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
- Zhejiang Provincial Key Laboratory of Cardio-Cerebral Vascular Detection Technology and Medicinal Effectiveness Appraisal; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - Qiuping Ding
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrumental Science; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - Hongjian He
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrumental Science; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - Yu Peng
- College of Civil Engineering and Architecture; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - Chen Li
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrumental Science; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - John Mai
- Alfred E. Mann Institute for Biomedical Engineering; University of Southern California; California Los Angeles 90089
| | - Jing-Song Li
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - Jianhui Zhong
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
- Center for Brain Imaging Science and Technology, College of Biomedical Engineering and Instrumental Science; Zhejiang University; Hangzhou 310027 People's Republic of China
| | - Ming-Wei Chang
- Key Laboratory for Biomedical Engineering of Education Ministry of China; Zhejiang University; Hangzhou 310027 People's Republic of China
- Zhejiang Provincial Key Laboratory of Cardio-Cerebral Vascular Detection Technology and Medicinal Effectiveness Appraisal; Zhejiang University; Hangzhou 310027 People's Republic of China
| |
Collapse
|
10
|
Grech-Sollars M, Zhou FL, Waldman AD, Parker GJM, Hubbard Cristinacce PL. Stability and reproducibility of co-electrospun brain-mimicking phantoms for quality assurance of diffusion MRI sequences. Neuroimage 2018; 181:395-402. [PMID: 29936312 DOI: 10.1016/j.neuroimage.2018.06.059] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 05/23/2018] [Accepted: 06/20/2018] [Indexed: 10/28/2022] Open
Abstract
Grey and white matter mimicking phantoms are important for assessing variations in diffusion MR measures at a single time point and over an extended period of time. This work investigates the stability of brain-mimicking microfibre phantoms and reproducibility of their MR derived diffusion parameters. The microfibres were produced by co-electrospinning and characterized by scanning electron microscopy (SEM). Grey matter and white matter phantoms were constructed from random and aligned microfibres, respectively. MR data were acquired from these phantoms over a period of 33 months. SEM images revealed that only small changes in fibre microstructure occurred over 30 months. The coefficient of variation in MR measurements across all time-points was between 1.6% and 3.4% for MD across all phantoms and FA in white matter phantoms. This was within the limits expected for intra-scanner variability, thereby confirming phantom stability over 33 months. These specialised diffusion phantoms may be used in a clinical environment for intra and inter-site quality assurance purposes, and for validation of quantitative diffusion biomarkers.
Collapse
Affiliation(s)
- Matthew Grech-Sollars
- Department of Surgery and Cancer, Imperial College London, London, UK; Department of Imaging, Imperial College Healthcare NHS Trust, London, UK.
| | - Feng-Lei Zhou
- Division of Informatics, Imaging and Data Sciences, The University of Manchester, Manchester, UK; The School of Materials, The University of Manchester, Manchester, United Kingdom.
| | - Adam D Waldman
- Centre for Clinical Brain Sciences, The University of Edinburgh, Edinburgh, UK; Department of Medicine, Imperial College London, UK
| | - Geoff J M Parker
- Division of Informatics, Imaging and Data Sciences, The University of Manchester, Manchester, UK; Bioxydyn Limited, Manchester, UK
| | | |
Collapse
|