1
|
Yamahata H, Yabuta M, Rahman M. Retrospective comparison of clinical outcomes of ultrasound-guided percutaneous cholecystostomy in patients with and without coagulopathy: a single center's experience. Jpn J Radiol 2023; 41:1015-1021. [PMID: 37029879 DOI: 10.1007/s11604-023-01422-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Accepted: 03/28/2023] [Indexed: 04/09/2023]
Abstract
PURPOSE To compare the complication rate and clinical outcomes for percutaneous cholecystostomy (PC) in patients with or without coagulopathy. MATERIALS AND METHODS We retrospectively reviewed electronic medical chart of patients who underwent ultrasound-guided PC with a 8.5-F drainage tube for acute cholecystitis between November 2003 and March 2017. We divided the patients into two groups: patients with coagulopathy (international normalized ratio > 1.5 or platelet count < 50 × 109/L or with a history of anticoagulant medication in preceding 5 days) and patients without coagulopathy. Duration of drainage, duration of hospital stay, 30-day mortality and complication rates were compared between these two groups. Student's t test, Chi-square test or Fisher's exact test was used for bivariate analyses. Age, age-adjusted Charlson Comorbidity Index (ACCI) and sepsis-adjusted complication rates were also compared. RESULTS In total, 141 patients had PC (mean age was 73.3 years [SD 13.3]; range 33-96 years; 94 men and 47 women). Fifty-two patients (36.9%) had coagulopathy and 89 patients (63.1%) were without any history of coagulopathy. Hemorrhagic complication rate was 3.5% (5 out of 141 patients, including 4 with coagulopathy and 1 without). One patient with coagulopathy died due to the hemorrhage. Duration of drainage was longer in patients with coagulopathy than patients without coagulopathy (20.0 days vs. 14.8 days; P = 0.033). No significant difference was observed with regard to duration of hospital stay (32.3 days vs. 25.6 days; P = 0.103) and 30-day mortality (7.7% vs. 1.1%; P = 0.062). The overall complication rate did not significantly differ (9.6% and 11.2%; P = 0.763), nor did age, ACCI or sepsis-adjusted complications. CONCLUSION Clinical outcomes and complications rates after PC did not statistically differ between patients with and without coagulopathy, but there was a tendency of higher risk of hemorrhage in coagulopathy patients. Therefore, the indication of this procedure should be carefully determined.
Collapse
Affiliation(s)
- Hayato Yamahata
- Department of Radiology, St. Luke's International Hospital, 9-1 Akashi-Cho, Chuo-Ku, Tokyo, 104-8560, Japan.
| | - Minoru Yabuta
- Department of Radiology, St. Luke's International Hospital, 9-1 Akashi-Cho, Chuo-Ku, Tokyo, 104-8560, Japan
| | - Mahbubur Rahman
- Division of Epidemiology, Graduate School of Public Health, St. Luke's International University, 3-6-2 Tsukiji, Chuo-Ku, Tokyo, 104-0045, Japan
| |
Collapse
|
2
|
Drake R, Jackson BP, Murphy CH. Single Plasma Unit Transfusions in Adults Are Either Unnecessary or Underdosed. Am J Clin Pathol 2022; 158:148-152. [PMID: 35218358 DOI: 10.1093/ajcp/aqac020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 01/27/2022] [Indexed: 12/25/2022] Open
Abstract
OBJECTIVES Previous studies of blood product use have shown higher inappropriate use of plasma compared with other products. Given typical weight-based dosing of plasma, we hypothesized that single plasma transfusions in adults would either be a nontherapeutic dose or outside clinical guidelines. METHODS A single-center, retrospective review of nonoperative, nonapheresis plasma use was conducted from January 2020 to April 2020. Plasma transfusions were reviewed for compliance with clinical guidelines formulated at our institution as well as national and society guidelines. RESULTS During the study period, 313 units of plasma were transfused. Of these, 152 (48.6%) were given against institutional or national guidelines, 126 plasma units (40.3%) were transfused as single units, and 187 (59.7%) were given as part of multiple-unit transfusions. All single-unit plasma transfusions during the study period were either underdosed or outside clinical guidelines. Units transfused with an indication of "Other" were significantly more likely to be outside clinical guidelines. CONCLUSIONS Nonoperative, nonapheresis plasma use is often outside clinical guidelines. Single-unit plasma transfusions in adults are a potential target for patient blood management programs seeking to minimize unnecessary plasma use.
Collapse
Affiliation(s)
- Rosanna Drake
- Department of Pathology, University of Maryland Medical Center, Baltimore, MD, USA
| | - Bryon P Jackson
- Department of Pathology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Colin H Murphy
- Department of Pathology, University of Maryland School of Medicine, Baltimore, MD, USA
| |
Collapse
|
3
|
Low Utility of Screening Hematologic Testing for Image-Guided Biopsies in Patients Without Bleeding Risks. AJR Am J Roentgenol 2020; 215:1279-1285. [PMID: 32901565 DOI: 10.2214/ajr.19.22414] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE. This study evaluates the prevalence of an abnormal international normalized ratio (INR) and platelet count before image-guided percutaneous needle biopsies over a 10-year period, comparing data from patients with and those without known conditions predisposing to coagulopathy. MATERIALS AND METHODS. A review of electronic medical records identified patients who were scheduled for a biopsy in a single institution's radiology department for the period of 2007-2016. The following information was recorded: demographic data, patient history of conditions that predispose to bleeding (e.g., liver disease, anticoagulant therapy, history of coagulopathy), and INR and platelet values within 30 days before biopsy. Data were stratified by biopsies that were performed versus those that were cancelled. RESULTS. Over 10 years, 3864 percutaneous biopsies were performed, and 6371 were cancelled. Approximately half of the biopsies (48.2%) were performed in patients without a predisposing condition; of those patients, 0.8% and 0.1% had an INR greater than 1.5 and greater than 1.8, respectively, and 0.4% had a platelet count of 50,000/μL or less (≤ 50 × 109/L). In patients with no known predisposing condition, 0.6% and 0.0% of biopsies cancelled were in patients who had an INR greater than 1.5 and greater than 1.8, respectively, and 0.1% of biopsies cancelled were in patients who had a platelet count of 50,000/μL or less. Ordering prebiopsy testing of patients with no predisposing conditions for the 1864 percutaneous biopsies performed over the 10-year study period resulted in more than $850,000 in laboratory-related health care costs. Our results suggest that the cost of identifying one abnormal INR is nearly $700,000. CONCLUSION. For patients without any known bleeding risks who are scheduled to undergo image-guided percutaneous biopsies, identifying an abnormal INR or abnormal platelet count is rare. Eliminating this testing in patients without predisposing conditions has the potential to create savings in costs and time for both physicians and patients.
Collapse
|
4
|
|
5
|
Storch EK, Custer BS, Jacobs MR, Menitove JE, Mintz PD. Review of current transfusion therapy and blood banking practices. Blood Rev 2019; 38:100593. [PMID: 31405535 DOI: 10.1016/j.blre.2019.100593] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 07/08/2019] [Accepted: 07/23/2019] [Indexed: 01/28/2023]
Abstract
Transfusion Medicine is a dynamically evolving field. Recent high-quality research has reshaped the paradigms guiding blood transfusion. As increasing evidence supports the benefit of limiting transfusion, guidelines have been developed and disseminated into clinical practice governing optimal transfusion of red cells, platelets, plasma and cryoprecipitate. Concepts ranging from transfusion thresholds to prophylactic use to maximal storage time are addressed in guidelines. Patient blood management programs have developed to implement principles of patient safety through limiting transfusion in clinical practice. Data from National Hemovigilance Surveys showing dramatic declines in blood utilization over the past decade demonstrate the practical uptake of current principles guiding patient safety. In parallel with decreasing use of traditional blood products, the development of new technologies for blood transfusion such as freeze drying and cold storage has accelerated. Approaches to policy decision making to augment blood safety have also changed. Drivers of these changes include a deeper understanding of emerging threats and adverse events based on hemovigilance, and an increasing healthcare system expectation to align blood safety decision making with approaches used in other healthcare disciplines.
Collapse
Affiliation(s)
| | - Brian S Custer
- UCSF Department of Laboratory Medicine, Blood Systems Research Institute, USA.
| | - Michael R Jacobs
- Department of Pathology, Case Western Reserve University, USA; Department of Clinical Microbiology, University Hospitals Cleveland Medical Center, USA.
| | - Jay E Menitove
- Department of Pathology and Laboratory Medicine, University of Kansas Medical Center, USA
| | | |
Collapse
|
6
|
Warner MA, Hanson AC, Weister TJ, Higgins AA, Madde NR, Schroeder DR, Kreuter JD, Kor DJ. Changes in International Normalized Ratios After Plasma Transfusion of Varying Doses in Unique Clinical Environments. Anesth Analg 2019; 127:349-357. [PMID: 29596103 DOI: 10.1213/ane.0000000000003336] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Plasma transfusion is commonly performed for the correction of abnormal coagulation screening tests. The goal of this investigation was to assess the relationship between the dose of plasma administered and changes in coagulation test results in a large and diverse cohort of patients with varying levels of coagulation abnormalities and comorbid disease and in a variety of clinical settings. METHODS In this single-center historical cohort study, all plasma transfusion episodes in adult patients with abnormal coagulation screening tests were extracted between 2011 and 2015. The primary outcome was the proportion of patients attaining normal posttransfusion international normalized ratio (INR ≤ 1.1) with secondary outcomes including the proportion of patients attaining partial normalization of INR (INR ≤ 1.5) or at least 50% normalization in pretransfusion values with respect to an INR of 1.1. RESULTS In total, 6779 unique patients received plasma with a median (quartiles) pretransfusion INR of 1.9 (1.6-2.5) and a median transfusion volume of 2 (2-3) units. The majority (85%) of transfusions occurred perioperatively, with 20% of transfusions administered prophylactically before a procedure. The median decrease in INR was 0.4 (0.2-0.8). Complete INR normalization was obtained in 12%. Reductions in INR were modest with pretransfusion INR values <3. Patients receiving ≥3 units of plasma were more likely to achieve at least 50% normalization in INR than those receiving ≤2 units (68% vs 60%; P < .001). CONCLUSIONS Changes in INR after plasma transfusion were modest at typically used clinical doses, particularly in those with less severely deranged baseline coagulation screening tests. Further studies are necessary to assess the relationships between plasma-mediated changes in INR and clinical outcomes.
Collapse
Affiliation(s)
- Matthew A Warner
- From the Division of Critical Care Medicine, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota.,Periprocedural Outcomes, Information and Transfusion Study Group, Mayo Clinic, Rochester, Minnesota
| | - Andrew C Hanson
- Department of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, Minnesota
| | - Timothy J Weister
- Periprocedural Outcomes, Information and Transfusion Study Group, Mayo Clinic, Rochester, Minnesota.,Department of Anesthesiology and Perioperative Medicine, Anesthesia Clinical Research Unit, Mayo Clinic, Rochester, Minnesota
| | | | - Nageswar R Madde
- Periprocedural Outcomes, Information and Transfusion Study Group, Mayo Clinic, Rochester, Minnesota.,Department of Anesthesiology and Perioperative Medicine, Anesthesia Clinical Research Unit, Mayo Clinic, Rochester, Minnesota
| | - Darrell R Schroeder
- Department of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, Minnesota
| | - Justin D Kreuter
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota
| | - Daryl J Kor
- From the Division of Critical Care Medicine, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota.,Periprocedural Outcomes, Information and Transfusion Study Group, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
7
|
Haaga J, Rahim S, Kondray V, Davidson J, Patel I, Nakamoto D. Comparison of Local Injection of Fresh Frozen Plasma to Traditional Methods of Hemostasis in Minimally Invasive Procedures. Acad Radiol 2018; 25:1617-1623. [PMID: 29573937 DOI: 10.1016/j.acra.2018.03.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2018] [Revised: 03/03/2018] [Accepted: 03/06/2018] [Indexed: 11/24/2022]
Abstract
RATIONALE AND OBJECTIVES To evaluate different techniques for reducing hemorrhagic complications in coagulopathic patients with elevated international normalized ratio having an image-guided percutaneous invasive procedure; techniques included systemic transfusion of fresh frozen plasma (FFP), local injection of FFP, percutaneous injection of gelatin sponge, and percutaneous placements of angiographic coils. MATERIALS AND METHODS Retrospective review of 232 consecutive patients with known coagulopathy undergoing image-guided minimally invasive procedures were selected. Ninety-one patients had local FFP injected, 40 patients underwent local synthetic gelatin injection, 16 patients had percutaneous coil embolization, and 85 patients received systemic FFP. The number of bleeds, complications related to bleeds, and systemic complications were recorded. A 30 cc threshold was used to delineate significant bleeding. RESULTS No patients experienced clinically significant or insignificant bleeding with local FFP injection (P value <.05). Other local hemostatic methods (Gelfoam, systemic FFP, and coil embolization) were associated with higher levels of bleeding (12.5%, 17.1%, 37.5%, respectively) and complications (7.5%, 31.4%, 37.5%, respectively). Systemic FFP infusion was associated with respiratory, infectious, and mortal complications. CONCLUSIONS Local injection of blood products provides a safe and efficacious hemostatic agent to reduce the incidence of postprocedural bleeding. The technique is associated with lower rates of bleeding and systemic complications when compared to other local and systemic techniques. Further randomized prospective studies with a larger patient cohort need to be performed to corroborate these initial findings.
Collapse
|
8
|
Warner MA, Frank RD, Weister TJ, Smith MM, Stubbs JR, Kor DJ. Higher intraoperative plasma transfusion volumes are associated with inferior perioperative outcomes. Transfusion 2018; 59:112-124. [PMID: 30383908 DOI: 10.1111/trf.14988] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 08/15/2018] [Accepted: 08/21/2018] [Indexed: 12/12/2022]
Abstract
BACKGROUND Intraoperative plasma transfusion is common, yet little is known regarding its effects on perioperative coagulation tests or clinical outcomes. STUDY DESIGN AND METHODS This is a retrospective cohort study of adults receiving intraoperative plasma transfusion at a single center from 2011 to 2015. Relationships between plasma transfusion volume, changes in coagulation test values, and clinical outcomes, including a primary outcome of early postoperative red blood cell (RBC) transfusion, were assessed with multivariable regression analyses. Secondary outcomes included hospital mortality, intensive care unit (ICU)- and hospital-free days, intraoperative RBC transfusions, and estimated blood loss. RESULTS A total of 3393 unique patients were included, with median (IQR) transfusion of 2 (2-4) units. In multivariable analyses, higher plasma volumes were associated with worse outcomes, with each 1 mL/kg increase associated with increased odds for postoperative (1.02 [1.01-1.03], p < 0.001) and intraoperative RBCs (1.17 [1.16-1.19], p < 0.001) and fewer ICU- and hospital-free days (mean difference [95% CI], -0.08 [-0.12 to -0.05], p < 0.001; and -0.09 [-0.13 to -0.06], p < 0.001, respectively). Greater decreases in international normalized ratio (INR) following plasma transfusion were associated with decreased odds of postoperative RBCs (0.35 [0.25-0.47], p < 0.001), decreased mortality (0.50 [0.31-0.83], p = 0.007), and increased mean ICU- (1.31 [0.41-2.21], p = 0.004) and hospital-free days (1.15 [0.19-2.10], p = 0.018). CONCLUSION In patients receiving intraoperative plasma transfusion, higher transfusion volumes were associated with inferior clinical outcomes; however, greater improvements in INR were associated with improved outcomes. Future prospective studies are necessary to better define these relationships and to explore plasma transfusion triggers beyond the limitations of INR.
Collapse
Affiliation(s)
- Matthew A Warner
- Division of Critical Care Medicine, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota
| | - Ryan D Frank
- Department of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, Minnesota
| | - Timothy J Weister
- Anesthesia Clinical Research Unit, Mayo Clinic, Rochester, Minnesota
| | - Mark M Smith
- Division of Cardiothoracic Anesthesia, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota
| | - James R Stubbs
- Division of Transfusion Medicine, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota
| | - Daryl J Kor
- Division of Critical Care Medicine, Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
9
|
Ngufor C, Warner MA, Murphree DH, Liu H, Carter R, Storlie CB, Kor DJ. Identification of Clinically Meaningful Plasma Transfusion Subgroups Using Unsupervised Random Forest Clustering. AMIA ... ANNUAL SYMPOSIUM PROCEEDINGS. AMIA SYMPOSIUM 2018; 2017:1332-1341. [PMID: 29854202 PMCID: PMC5977681] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Statistical techniques such as propensity score matching and instrumental variable are commonly employed to "simulate" randomization and adjust for measured confounders in comparative effectiveness research. Despite such adjustments, the results of these methods apply essentially to an "average" patient. However, as patients show significant heterogeneity in their responses to treatments, this average effect is of limited value. It does not account for individual level variabilities, which can deviate substantially from the population average. To address this critical problem, we present a framework that allows the discovery of clinically meaningful homogeneous subgroups with differential effects of plasma transfusion using unsupervised random forest clustering. Subgroup analysis using two blood transfusion datasets show that considerable variablilities exist between the subgroups and population in both the treatment effect of plasma transfusion on bleeding and mortality and risk factors for these outcomes. These results support the customization of blood transfusion therapy for the individual patient.
Collapse
|
10
|
Blaine KP, Sakai T. Viscoelastic Monitoring to Guide Hemostatic Resuscitation in Liver Transplantation Surgery. Semin Cardiothorac Vasc Anesth 2017; 22:150-163. [PMID: 29099334 DOI: 10.1177/1089253217739121] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Coagulopathic bleeding must be anticipated during liver transplantation (LT) surgery. Patients with end-stage liver disease (ESLD) often present with disease-related hematologic disturbances, including the loss of hepatic procoagulant and anticoagulant clotting factors and thrombocytopenia. Transplantation surgery itself presents additional hemostatic changes, including hyperfibrinolysis. Viscoelastic monitoring (VEM) is often used to provide targeted, personalized hemostatic therapies for complex bleeding states including cardiac surgery and major trauma. The use in these coagulopathic conditions led to its application to LT, although the mechanisms of coagulopathy in these patients are quite different. While VEM is often used during transplant surgeries in Europe and North America, evidence supporting its use is limited to a few small clinical studies. The theoretical and clinical applications of the standard and specialized VEM assays are discussed in the setting of LT and ESLD.
Collapse
Affiliation(s)
- Kevin P Blaine
- 1 Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA
| | - Tetsuro Sakai
- 2 University of Pittsburgh Medical Center Health System, Pittsburgh, PA, USA
| |
Collapse
|