1
|
Huang SX, Yang SH, Zeng B, Li XH. Personalized selection of unequal sub-arc collimator angles in VMAT for multiple brain metastases. Appl Radiat Isot 2024; 214:111513. [PMID: 39276636 DOI: 10.1016/j.apradiso.2024.111513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2024] [Revised: 09/02/2024] [Accepted: 09/06/2024] [Indexed: 09/17/2024]
Abstract
PURPOSE Investigating the effects of unequal sub-arc personalized collimator angle selection on the quality of Volumetric Modulated Arc Therapy (VMAT) plans for treating multiple brain metastases. METHODS This study included 21 patients, each with 2-4 target volumes of multiple brain metastases. Two stereotactic radiotherapy (SRT) approaches were utilized: sub-arc collimator VMAT (SAC-VMAT) and fixed collimator VMAT (FC-VMAT). In the SAC-VMAT group, multi-leaf collimators (MLC) shaped the target area, dividing the full arc into four unequal sub-arcs under the beam's eye view (BEV). Each sub-arc had an appropriate collimator angle selected to mitigate 'island blocking problems'. Conversely, the FC-VMAT group used a fixed collimator angle of 15° or 345°. A comparative analysis of the dosimetric parameters of the target volumes and normal tissues, along with the monitor units (MU), was conducted between the two groups. RESULTS The mean dose and dose-volume to normal brain tissue (2-26 Gy, with a step of 2 Gy) were significantly lower in the SAC-VMAT group (P < 0.01). There was no statistical difference between the two groups in dose to the target volumes, conformity index (CI), homogeneity index (HI), and other normal tissues (P > 0.05). Compared with the FA-VMAT group, the SAC-VMAT group significantly reduced the gradient index (GI) (4.5 ± 0.59 vs 5.2 ± 0.75, P < 0.001) and MU (1774.33 ± 181.77 vs 2001.0 ± 344.86, P < 0.001). Notably, with an increase in the number of PTV, the SAC-VMAT group demonstrated more significant improvements in the dose-volume of normal brain tissue, GI, and MU. CONCLUSIONS In this study, personalized selection of the unequal sub-arc collimator angle ensured the prescribed dose to the PTV, CI, and HI, while significantly reducing the GI, MU, and the dose to normal brain tissue in the VMAT plan for multi-target brain metastases in the cohort of cases with 2-4 target volumes. Particularly as the number of targets increase, the advantages of this method become more pronounced.
Collapse
Affiliation(s)
- Shi-Xiong Huang
- School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China; Department of Radiation Oncology, Hunan Cancer Hospital/the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University, Changsha, 410013, China
| | - Song-Hua Yang
- Department of Clinical Pharmaceutical Research Institution, Hunan Cancer Hospital/the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University, Changsha, 410013, China
| | - Biao Zeng
- Department of Radiation Oncology, Hunan Cancer Hospital/the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University, Changsha, 410013, China.
| | - Xiao-Hua Li
- School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China.
| |
Collapse
|
2
|
Huang SX, Yang SH, Zeng B, Li XH. Optimization of sub-arc collimator angles in volumetric modulated arc therapy: a heatmap-based blocking index approach for multiple brain metastases. Phys Eng Sci Med 2024:10.1007/s13246-024-01477-y. [PMID: 39235667 DOI: 10.1007/s13246-024-01477-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Accepted: 08/07/2024] [Indexed: 09/06/2024]
Abstract
To develop and assess an automated Sub-arc Collimator Angle Optimization (SACAO) algorithm and Cumulative Blocking Index Ratio (CBIR) metrics for single-isocenter coplanar volumetric modulated arc therapy (VMAT) to treat multiple brain metastases. This study included 31 patients with multiple brain metastases, each having 2 to 8 targets. Initially, for each control point, the MLC blocking index was calculated at different collimator angles, resulting in a two-dimensional heatmap. Optimal sub-arc segmentation and collimator angle optimization were achieved using an interval dynamic programming algorithm. Subsequently, VMAT plans were designed using two approaches: SACAO and the conventional Full-Arc Fixed Collimator Angle. CBIR was calculated as the ratio of the cumulative blocking index between the two plan approaches. Finally, dosimetric and planning parameters of both plans were compared. Normal brain tissue, brainstem, and eyes received better protection in the SACAO group (P < 0.05).Query Notable reductions in the SACAO group included 11.47% in gradient index (GI), 15.03% in monitor units (MU), 15.73% in mean control point Jaw area (AJaw,mean), and 19.14% in mean control point Jaw-X width (WJaw-X,mean), all statistically significant (P < 0.001). Furthermore, CBIR showed a strong negative correlation with the degree of plan improvement. The SACAO method enhanced protection of normal organs while improving transmission efficiency and optimization performance of VMAT. In particular, the CBIR metrics show promise in quantifying the differences specifically in the 'island blocking problem' between SACAO and conventional VMAT, and in guiding the enhanced application of the SACAO algorithm.
Collapse
Affiliation(s)
- Shi-Xiong Huang
- School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China
- Department of Radiation Oncology, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital, Changsha, 410013, Hunan, People's Republic of China
| | - Song-Hua Yang
- Department of Clinical Pharmaceutical Research Institution,Hunan Cancer Hospital/the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University, Changsha, 410013, Hunan, People's Republic of China
| | - Biao Zeng
- Department of Radiation Oncology, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital, Changsha, 410013, Hunan, People's Republic of China.
| | - Xiao-Hua Li
- School of Nuclear Science and Technology, University of South China, Hengyang, 421001, China.
| |
Collapse
|
3
|
Mishra A, Pathak R, Mittal KK, Srivastava AK, Dayashankar MS, Mishra SP, Singh SK. Efficacy of the collapsed cone algorithm calculated radiotherapy plans in intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT): A comparative dosimetric study in tumors of thorax. J Cancer Res Ther 2024; 20:383-388. [PMID: 38554350 DOI: 10.4103/jcrt.jcrt_2171_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 12/08/2022] [Indexed: 04/01/2024]
Abstract
AIM In this study, efficacy of collapsed cone algorithm-generated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) were evaluated for treatment of thoracic esophageal cancer. MATERIALS AND METHODS Ten previously treated patients with VMAT were considered for evaluation. The planning parameters were evaluated in terms of max dose, mean dose, Homogeneity Index, Conformity Index for planning target volume, and organ at risk doses. Total monitor unit, treatment time, and gamma passing index were also reported. RESULTS The target dose coverage of the VMAT and IMRT plans achieved the clinical dosimetric criteria for all ten patients in the evaluation. Under the condition of equivalent target dose distribution, the VMAT plan's Conformity Index, monitor unit, treatment time, and gamma passing index rate were superior than in the IMRT plan, and the result was statistically significant. CONCLUSION Collapsed cone algorithm-based VMAT can have a more effective and better approach for esophageal cancer than IMRT.
Collapse
Affiliation(s)
- Atul Mishra
- Department of Physics, Tilak Dhari P. G. College, Jaunpur, Uttar Pradesh, India
- Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India
- Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India
| | - Ramji Pathak
- Department of Physics, Tilak Dhari P. G. College, Jaunpur, Uttar Pradesh, India
- Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India
- Department of Physics, D.A.V. Degree College, Lucknow, Uttar Pradesh, India
| | - Kailash Kumar Mittal
- Department of Radiation Oncology, Uttar Pradesh University of Medical Sciences, Saifai, Etawah, Uttar Pradesh, India
| | - Anoop Kumar Srivastava
- Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Maurya Surendrakumar Dayashankar
- Department of Applied Physics, Amity University Gwalior, Madhya Pradesh, India
- Department of Radiation Oncology, Shalby Hospitals Indore, Madhya Pradesh, India
| | - Surendra Prasad Mishra
- Department of Radiation Oncology, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Sudesh Kumar Singh
- Department of Physics, Tilak Dhari P. G. College, Jaunpur, Uttar Pradesh, India
- Veer Bahadur Singh Purvanchal University, Jaunpur, Uttar Pradesh, India
| |
Collapse
|
4
|
Shao Y, Guo J, Wang J, Huang Y, Gan W, Zhang X, Wu G, Sun D, Gu Y, Gu Q, Yue NJ, Yang G, Xie G, Xu Z. Novel in-house knowledge-based automated planning system for lung cancer treated with intensity-modulated radiotherapy. Strahlenther Onkol 2023:10.1007/s00066-023-02126-1. [PMID: 37603050 DOI: 10.1007/s00066-023-02126-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 07/10/2023] [Indexed: 08/22/2023]
Abstract
PURPOSE The goal of this study was to propose a knowledge-based planning system which could automatically design plans for lung cancer patients treated with intensity-modulated radiotherapy (IMRT). METHODS AND MATERIALS From May 2018 to June 2020, 612 IMRT treatment plans of lung cancer patients were retrospectively selected to construct a planning database. Knowledge-based planning (KBP) architecture named αDiar was proposed in this study. It consisted of two parts separated by a firewall. One was the in-hospital workstation, and the other was the search engine in the cloud. Based on our previous study, A‑Net in the in-hospital workstation was used to generate predicted virtual dose images. A search engine including a three-dimensional convolutional neural network (3D CNN) was constructed to derive the feature vectors of dose images. By comparing the similarity of the features between virtual dose images and the clinical dose images in the database, the most similar feature was found. The optimization parameters (OPs) of the treatment plan corresponding to the most similar feature were assigned to the new plan, and the design of a new treatment plan was automatically completed. After αDiar was developed, we performed two studies. The first retrospective study was conducted to validate whether this architecture was qualified for clinical practice and involved 96 patients. The second comparative study was performed to investigate whether αDiar could assist dosimetrists in improving the quality of planning for the patients. Two dosimetrists were involved and designed plans for only one trial with and without αDiar; 26 patients were involved in this study. RESULTS The first study showed that about 54% (52/96) of the automatically generated plans would achieve the dosimetric constraints of the Radiation Therapy Oncology Group (RTOG) and about 93% (89/96) of the automatically generated plans would achieve the dosimetric constraints of the National Comprehensive Cancer Network (NCCN). The second study showed that the quality of treatment planning designed by junior dosimetrists was improved with the help of αDiar. CONCLUSIONS Our results showed that αDiar was an effective tool to improve planning quality. Over half of the patients' plans could be designed automatically. For the remaining patients, although the automatically designed plans did not fully meet the clinical requirements, their quality was also better than that of manual plans.
Collapse
Affiliation(s)
- Yan Shao
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jindong Guo
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Jiyong Wang
- Shanghai Pulse Medical Technology Inc., Shanghai, China
| | - Ying Huang
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China
| | - Wutian Gan
- School of Physics and Technology, University of Wuhan, Wuhan, China
| | - Xiaoying Zhang
- School of Information Science and Engineering, Xiamen University, Xiamen, China
| | - Ge Wu
- Ping An Healthcare Technology Co. Ltd., Shanghai, China
| | - Dong Sun
- School of Biomedical Engineering, Health Science Center, Shenzhen University, Shenzhen, China
| | - Yu Gu
- School of Engineering, Hong Kong University of Science and Technology, Hong Kong SAR, China
| | - Qingtao Gu
- School of Medicine and Biological Information Engineering, Northeastern University, Shenyang, China
| | - Ning Jeff Yue
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, USA
| | - Guanli Yang
- Radiotherapy Department, Shandong Second Provincial General Hospital, Shandong University, Jinan, China.
| | - Guotong Xie
- Ping An Healthcare Technology Co. Ltd., Shanghai, China.
- Ping An Health Cloud Company Limited, Shanghai, China.
- Ping An International Smart City Technology Co., Ltd., Shanghai, China.
| | - Zhiyong Xu
- Shanghai Chest Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
5
|
Gram VR, Gram D, Persson GF, Suppli MH, Barrett S. Reduction of oesophageal toxicity with VMAT dose-sparing radiotherapy in thoracic metastatic spinal cord compression: A feasibility study. Tech Innov Patient Support Radiat Oncol 2022; 23:8-14. [PMID: 35935707 PMCID: PMC9352452 DOI: 10.1016/j.tipsro.2022.07.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/08/2022] [Accepted: 07/13/2022] [Indexed: 11/14/2022] Open
Abstract
Oesophageal delineation took a mean of 8.6 min. Significant dose reduction for oesophageal V7.7 Gy, D2% and Dmean were achieved, without significant change in CTV coverage. Reduction of oesophageal dose may lead to reduced acute toxicity in this patient group where quality of life is a key concern.
Background Palliative radiotherapy for metastatic spinal cord compression (MSCC) is given to halt disease progression and sustain quality of life for patients with advanced cancer. Radiotherapy can however induce toxicity, contradicting treatment intention. Advanced radiotherapy offers possibility of sparing organs at risk (OARs). The purpose of this dosimetric study is to establish the feasibility and potential benefits of dose sparing of the oesophagus. Materials and methods 30 patients receiving radiotherapy of 30 Gy/10# for MSCC were retrospectively included and the oesophagus delineated. Two new dose plans were created for each patient (eso-crop and PTV-crop) with the intention of optimising the oesophageal dose. In the eso-crop plan maintaining full target volume coverage was prioritised, for the PTV-crop plan oesophageal dose was further reduced through cropping the planning target volume (PTV) overlapping oesophageal/PTV-area. Time added for delineation was measured. Plans were compared using Wilcoxon signed rank test with p < 0.05 considered statistically significant. Bivariate associations between dose metrics and patient characteristics were quantified using linear regression models. Results Oesophageal delineation took a mean of 8.6 min. There was significant dose reduction for both V7.7 Gy, D2% and mean oesophageal dose, without significant change in CTV coverage. The mean achievable oesophageal dose reduction was 29.1% and 50.4% for the eso-crop and PTV crop plans, respectively. Minor changes in dose distribution to the lungs was observed, with increased mean and V20Gy for the eso-crop plan and decreased V5Gy to the PTV-crop plan. Conclusion This study demonstrated the possibility of significant dose sparing of the oesophageal dose using single arc VMAT without impacting on CTV coverage.
Collapse
|
6
|
Xi D, Jiao T, Mu J, Chen Y, Gu W, Li Q. The application of chair homogeneity index: The advantages of DMLC over VMAT in the radiotherapy for esophageal cancer. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2022. [DOI: 10.1016/j.jrras.2021.11.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
7
|
Hsu CX, Lin KH, Wang SY, Tsai WT, Chang CH, Tien HJ, Shueng PW, Wu TH, Mok GSP. Planning evaluation of a novel volume-based algorithm for personalized optimization of lung dose in VMAT for esophageal cancer. Sci Rep 2022; 12:2513. [PMID: 35169144 PMCID: PMC8847643 DOI: 10.1038/s41598-021-04571-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2021] [Accepted: 12/20/2021] [Indexed: 11/09/2022] Open
Abstract
Radiotherapy treatment planning (RTP) is time-consuming and labor-intensive since medical physicists must devise treatment plans carefully to reduce damage to tissues and organs for patients. Previously, we proposed the volume-based algorithm (VBA) method, providing optimal partial arcs (OPA) angle to achieve the low-dose volume of lungs in dynamic arc radiotherapy. This study aimed to implement the VBA for esophageal cancer (EC) patients and compare the lung dose and delivery time between full arcs (FA) without using VBA and OPA angle using VBA in volumetric modulated arc therapy (VMAT) plans. We retrospectively included 30 patients diagnosed with EC. RTP of each patient was replanned to 4 VMAT plans, including FA plans without (FA-C) and with (FA + C) dose constraints of OARs and OPA plans without (OPA-C) and with (OPA + C) dose constraints of OARs. The prescribed dose was 45 Gy. The OARs included the lungs, heart, and spinal cord. The dose distribution, dose-volume histogram, monitor units (MUs), delivery time, and gamma passing rates were analyzed. The results showed that the lung V5 and V10 in OPA + C plans were significantly lower than in FA + C plans (p < 0.05). No significant differences were noted in planning target volume (PTV) coverage, lung V15, lung V20, mean lung dose, heart V30, heart V40, mean heart dose, and maximal spinal cord dose between FA + C and OPA + C plans. The delivery time was significantly longer in FA + C plans than in OPA + C plans (237 vs. 192 s, p < 0.05). There were no significant differences between FA + C and OPA + C plans in gamma passing rates. We successfully applied the OPA angle based on the VBA to clinical EC patients and simplified the arc angle selection in RTP. The VBA could provide a personalized OPA angle for each patient and effectively reduce lung V5, V10, and delivery time in VMAT.
Collapse
Affiliation(s)
- Chen-Xiong Hsu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Kuan-Heng Lin
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan.,Industrial Ph.D. Program of Biomedical Science and Engineering, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Shan-Ying Wang
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Department of Nuclear Medicine, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Wei-Ta Tsai
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan
| | - Chiu-Han Chang
- Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hui-Ju Tien
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.,Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Pei-Wei Shueng
- Division of Radiation Oncology, Far Eastern Memorial Hospital, New Taipei City, Taiwan. .,Faculty of Medicine, School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| | - Tung-Hsin Wu
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan.
| | - Greta S P Mok
- Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau, SAR, China
| |
Collapse
|
8
|
Shao Y, Chen H, Wang H, Duan Y, Feng A, Huang Y, Gu H, Kong Q, Xu Z. Investigation of Predictors to Achieve Acceptable Lung Dose in T-Shaped Upper and Middle Esophageal Cancer With IMRT and VMAT. Front Oncol 2021; 11:735062. [PMID: 34692508 PMCID: PMC8529030 DOI: 10.3389/fonc.2021.735062] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Accepted: 09/09/2021] [Indexed: 12/24/2022] Open
Abstract
Purpose The purpose of this study is to investigate whether there are predictors and cutoff points that can predict the acceptable lung dose using intensity-modulated radiation therapy (IMRT) and volume-modulated arc therapy (VMAT) in radiotherapy for upper ang middle esophageal cancer. Material and Methods Eighty-two patients with T-shaped upper-middle esophageal cancer (UMEC) were enrolled in this retrospective study. Jaw-tracking IMRT plan (JT-IMRT), full-arc VMAT plan (F-VMAT), and pactial-arc VMAT plan (P-VMAT) were generated for each patient. Dosimetric parameters such as MLD and V20 of total lung were compared among the three plannings. Ten factors such as PCTVinferior length and PCTVinferior length/total lung length were calculated to find the predictors and cutoff points of the predictors. All patients were divided into two groups according to the cutoff points, and the dosimetric differences between the two groups of the three plans were compared. ANOVA, receiver operating characteristic (ROC) analysis, and Mann–Whitney U-test were performed for comparisons between datasets. A p <0.05 was considered statistically significant. Result The quality of the targets of the three plannings was comparable. The total lung dose in P-VMAT was significantly lower than that in JT IMRT and F-VMAT. Monitor unit (MU) of F-VMAT and P-VMAT was significantly lower than that of JT IMRT. ROC analysis showed that among JT IMRT, F-VMAT, and P-VMAT, PCTVi-L, and PCTVi-L/TLL had diagnostic power to predict the suitability of RT plans according to lung dose constraints of our department. For JT IMRT, the cutoff points of PCTVi-L and PCTVi-L/TLL were 16.6 and 0.59. For F-VMAT, the cutoff points of PCTVi-L and PCTVi-L/TLL were 16.75 and 0.62. For P-VMAT, the cutoff points of PCTVi-L and PCTVi-L/TLL were 15.15 and 0.59. After Mann–Whitney U-test analysis, it was found that among the three plannings, the group with lower PCTVi-L and PCTVi-L/TLL could significantly reduce the dose of total lung and heart (p <0.05). Conclusion PCTVi-L <16.6 and PCTVi-L/TLL <0.59 for JT IMRT, PCTVi-L <16.75 and PCTVi-L/TLL <0.62 for F-VMAT and PCTVi-L <15.15, and PCTVi-L/TLL <0.59 for P-VMAT can predict whether patients with T-shaped UMEC can meet the lung dose limits of our department.
Collapse
Affiliation(s)
- Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.,Institute of Modern Physics, Fudan University, Shanghai, China
| | - Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China.,Institute of Modern Physics, Fudan University, Shanghai, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yanhua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Aihui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hengle Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Qing Kong
- Institute of Modern Physics, Fudan University, Shanghai, China
| | - Zhiyong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
9
|
Duan Y, Zhou L, Wang H, Chen H, Gu H, Shao Y, Feng A, Huang Y, Fu X, Yue NJ, Ma K, Kong Q, Xu Z. A novel CRT-IMRT-combined (Co-CRIM) planning technique for peripheral lung stereotactic body radiotherapy in pinnacle treatment planning system. J Appl Clin Med Phys 2021; 22:97-107. [PMID: 34699670 PMCID: PMC8664147 DOI: 10.1002/acm2.13461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 09/27/2021] [Accepted: 10/10/2021] [Indexed: 12/31/2022] Open
Abstract
Objectives This study attempts to explore a novel peripheral lung stereotactic body radiotherapy (SBRT) planning technique that can balance the pros and cons of three‐dimensional conformal radiotherapy (CRT) and intensity‐modulated radiation therapy (IMRT) / volumetric modulated arc therapy (VMAT). Methods Treatment plans were retrospectively designed based on CRT, IMRT, VMAT, and the proposed CRT‐IMRT‐combined (Co‐CRIM) techniques using Pinnacle treatment planning system (TPS) for 20 peripheral lung cancer patients. Co‐CRIM used an inverse optimization algorithm available in Pinnacle TPS. To develop a Co‐CRIM plan, the number of segments in each field was limited to one, the minimum segment area was set to the internal target volume (ITV), and the minimum monitor units (MU) of the segment was the quotient of fractional dose divided by twice the number of total fields. The performance of Co‐CRIM was then compared with other techniques. Results For conformity index (CI), Co‐CRIM performed comparably to IMRT/VMAT but better than CRT. For gradient index (GI), Co‐CRIM was similar to IMRT/VMAT or CRT. For heterogeneity index (HI), Co‐CRIM was comparable to IMRT/VMAT, higher than CRT. The dosimetric results of spinal cord and lung with Co‐CRIM were better than CRT, comparable to IMRT, but inferior to VMAT. The MU resulted from Co‐CRIM was lower than IMRT/VMAT but higher than CRT. For plan verification γ passing rate, Co‐CRIM was higher than IMRT/VMAT, comparable to CRT. For planning time, Co‐CRIM was shorter than CRT or VMAT but similar to IMRT. Conclusions The proposed Co‐CRIM technique on Pinnacle TPS is an effective planning technique for peripheral lung SBRT.
Collapse
Affiliation(s)
- YanHua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - LiJun Zhou
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - HengLe Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - AiHui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - XiaoLong Fu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Ning Jeff Yue
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Jersey, USA
| | - Kui Ma
- Clinical helpdesk, Varian Medical Systems, Beijing, China
| | - Qing Kong
- Institute of Modern Physics, Fudan University, Shanghai, China
| | - ZhiYong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
10
|
Duan Y, Cao H, Wu B, Wu Y, Liu D, Zhou L, Feng A, Wang H, Chen H, Gu H, Shao Y, Huang Y, Lin Y, Ma K, Fu X, Fu H, Kong Q, Xu Z. Dosimetric Comparison, Treatment Efficiency Estimation, and Biological Evaluation of Popular Stereotactic Radiosurgery Options in Treating Single Small Brain Metastasis. Front Oncol 2021; 11:716152. [PMID: 34540686 PMCID: PMC8447903 DOI: 10.3389/fonc.2021.716152] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 07/14/2021] [Indexed: 11/24/2022] Open
Abstract
Objectives This study aimed to show the advantages of each stereotactic radiosurgery (SRS) treatment option for single small brain metastasis among Gamma Knife (GK), Cone-based VMAT (Cone-VMAT), and MLC-based CRT (MLC-CRT) plans. Materials and Methods GK, Cone-VMAT, and MLC-CRT SRS plans were retrospectively generated for 11 patients with single small brain metastasis whose volume of gross tumor volume (GTV) ranged from 0.18 to 0.76 cc (median volume 0.60 cc). Dosimetric parameters, treatment efficiency, and biological parameters of the three techniques were compared and evaluated. The metric variation with the planning target volume (PTV) was also studied. Results The conformity index (CI) was similar in GK and MLC-CRT plans, higher than Cone-VMAT. Cone-VMAT achieved comparable volume covered by 12 Gy (V12) and gradient index (GI) as GK, lower than MLC-CRT. The heterogeneity index (HI) of GK, Cone-VMAT, and MLC-CRT decreased sequentially. GK gave the lowest volume covered by 3 Gy (V3) and 6 Gy (V6), while MLC-CRT got the highest. The beam-on time and treatment time of GK, Cone-VMAT, and MLC-CRT decreased in turn. Tumor control probability (TCP) of all three SRS plans was greater than 98%, and normal tissue complication probability (NTCP) of all organs at risk (OARs) was below 0.01%. GK and Cone-VMAT resulted in superior TCP and NTCP of the normal brain tissue than MLC-CRT. The relative value of Cone-VMAT and GK for all metrics hardly changed with the target volume. Except for the unchanged HI and TCP, the other results of MLC-CRT with respect to GK improved as the target volume increased. MLC-CRT could produce higher CI than GK and Cone-VMAT when the target volume increased above 2 and 1.44 cc, respectively. Conclusion For single small brain metastases, Cone-VMAT may be used as an alternative to GK-free centers. In addition to the advantage of short treatment time, MLC-CRT showed superiority in CI as the target volume increased. Treatment centers can choose appropriate SRS technique on a case-by-case basis according to institutional conditions and patients’ individual needs.
Collapse
Affiliation(s)
- Yanhua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hongbin Cao
- Department of Radiation Oncology, Renji Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Boheng Wu
- Department of Radiation Oncology, Renji Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yinghui Wu
- Nuclear Protective Treatment Department of Radiation, Navy Specialty Medical Center, Shanghai, China
| | - Dong Liu
- Varian Medical Systems, Inc., Beijing, China
| | - Lijun Zhou
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, China
| | - Aihui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hengle Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Yang Lin
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Kui Ma
- Varian Medical Systems, Inc., Beijing, China
| | - Xiaolong Fu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| | - Hong Fu
- Department of Mathematics and Information Technology, The Education University of Hong Kong, Hong Kong, China
| | - Qing Kong
- Institute of Modern Physics, Fudan University, Shanghai, China
| | - Zhiyong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
11
|
Chen H, Huang Y, Wang H, Shao Y, Yue NJ, Gu H, Duan Y, Feng A, Xu Z. Dosimetric comparison and biological evaluation of fixed-jaw intensity-modulated radiation therapy for T-shaped esophageal cancer. Radiat Oncol 2021; 16:158. [PMID: 34412656 PMCID: PMC8375041 DOI: 10.1186/s13014-021-01882-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Accepted: 08/11/2021] [Indexed: 12/24/2022] Open
Abstract
Background To evaluate the dosimetric and biological benefits of the fixed-jaw (FJ) intensity-modulated radiation therapy (IMRT) technique for patients with T-shaped esophageal cancer. Methods FJ IMRT plans were generated for thirty-five patients and compared with jaw tracking (JT) IMRT, static jaw (SJ) IMRT and JT volumetric modulated arc therapy (VMAT). Dosimetric parameters, tumor control probability (TCP) and normal tissue complication probability (NTCP), monitor units (MUs), delivery time and gamma passing rate, as a measure of dosimetric verification, were compared. The correlation between the length of PTV-C below the upper boundary of lung tissue (PTV-Cinferior) and dosimetric parameters and NTCP of the lung tissue were analyzed. Results The homogeneity and conformity of the target in the four plans were basically equivalent. When compared to the JT IMRT and SJ IMRT plans, FJ IMRT plan led to a statistically significant improvement in the NTCP and low-middle dosimetric parameters of the lung, and the improvement had a moderately positive correlation with the length of PTV-Cinferior, with a correlation coefficient ranging from 0.523 to 0.797; the FJ IMRT plan exhibited better lung sparing in low-dose volumes than the JT VMAT plan. The FJ IMRT plan had similar MUs (888 ± 99) and delivery times (516.1 ± 54.7 s) as the JT IMRT plan (937 ± 194, 522 ± 5.6 s) but higher than SJ IMRT (713 ± 137, 488.8 ± 45.2 s) and JT VMAT plan (517 ± 59, 263.7 ± 43.3 s). Conclusions The FJ IMRT technique is superior in reducing the low-dose volumes of lung tissues for patients with T-shaped esophageal cancer.
Collapse
Affiliation(s)
- Hua Chen
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Ying Huang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Hao Wang
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Yan Shao
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Ning J Yue
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, 08903, USA
| | - Hengle Gu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Yanhua Duan
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Aihui Feng
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China
| | - Zhiyong Xu
- Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University, No. 241 West Huaihai Road, Xuhui District, Shanghai, 200030, China.
| |
Collapse
|
12
|
Liu FY, Dong ZW, Yang HB, Shi HY. Evaluation of the clinical application of Auto-Planning module for IMRT plans of left breast cancer. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
13
|
Smith A, Granatowicz A, Stoltenberg C, Wang S, Liang X, Enke CA, Wahl AO, Zhou S, Zheng D. Can the Student Outperform the Master? A Plan Comparison Between Pinnacle Auto-Planning and Eclipse knowledge-Based RapidPlan Following a Prostate-Bed Plan Competition. Technol Cancer Res Treat 2019; 18:1533033819851763. [PMID: 31177922 PMCID: PMC6558545 DOI: 10.1177/1533033819851763] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Purpose: Pinnacle Auto-Planning and Eclipse RapidPlan are 2 major commercial automated planning
engines that are fundamentally different: Auto-Planning mimics real planners in the
iterative optimization, while RapidPlan generates static dose objectives from
estimations predicted based on a prior knowledge base. This study objectively compared
their performances on intensity-modulated radiotherapy planning for prostate fossa and
lymphatics adopting the plan quality metric used in the 2011 American Association of
Medical Dosimetrists Plan Challenge. Methods: All plans used an identical intensity-modulated radiotherapy beam setup and a
simultaneous integrated boost prescription (68 Gy/56 Gy to prostate fossa/lymphatics).
Auto-Planning was used to retrospectively plan on 20 patients, which were subsequently
employed as the library to build an RapidPlan model. To compare the 2 engines’
performances, a test set including 10 patients and the Plan Challenge patient was
planned by both Auto-Planning (master) and RapidPlan (student) without manual
intervention except for a common dose normalization and evaluated using the plan quality
metric that included 14 quantitative submetrics ranging over target coverage, spillage,
and organ at risk doses. Plan quality metric scores were compared between the
Auto-Planning and RapidPlan plans using the Mann-Whitney U test. Results: There was no significant difference between the overall performance of the 2 engines on
the 11 test cases (P = .509). Among the 14 submetrics, Auto-Planning
and RapidPlan showed no significant difference on most submetrics except for 2. On the
Plan Challenge case, Auto-Planning scored 129.9 and RapidPlan scored 130.3 out of 150,
as compared with the average score of 116.9 ± 16.4 (range: 58.2-142.5) among the 125
Plan Challenge participants. Conclusion: Using an innovative study design, an objective comparison has been conducted between 2
major commercial automated inverse planning engines. The 2 engines performed comparably
with each other and both yielded plans at par with average human planners. Using a
constant-performing planner (Auto-Planning) to train and to compare, RapidPlan was found
to yield plans no better than but as good as its library plans.
Collapse
Affiliation(s)
- April Smith
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Andrew Granatowicz
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Cole Stoltenberg
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Shuo Wang
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Xiaoying Liang
- 2 University of Florida Proton Therapy Institute, Jacksonville, FL, USA
| | - Charles A Enke
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Andrew O Wahl
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Sumin Zhou
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| | - Dandan Zheng
- 1 Radiation Oncology, University of Nebraska Medical Center, Omaha, NE, USA
| |
Collapse
|
14
|
Ling C, Han X, Zhai P, Xu H, Chen J, Wang J, Hu W. A hybrid automated treatment planning solution for esophageal cancer. Radiat Oncol 2019; 14:232. [PMID: 31856866 PMCID: PMC6923830 DOI: 10.1186/s13014-019-1443-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 12/11/2019] [Indexed: 12/23/2022] Open
Abstract
OBJECTIVE This study aims to investigate a hybrid automated treatment planning (HAP) solution that combines knowledge-based planning (KBP) and script-based planning for esophageal cancer. METHODS In order to fully investigate the advantages of HAP, three planning strategies were implemented in the present study: HAP, KBP, and full manual planning. Each method was applied to 20 patients. For HAP and KBP, the objective functions for plan optimization were generated from a dose-volume histogram (DVH) estimation model, which was based on 70 esophageal patients. Script-based automated planning was used for HAP, while the regular IMRT inverse planning method was used for KBP. For full manual planning, clinical standards were applied to create the plans. Paired t-tests were performed to compare the differences in dose-volume indices among the three planning methods. RESULTS Among the three planning strategies, HAP exhibited the best performance in all dose-volume indices, except for PTV dose homogeneity and lung V5. PTV conformity and spinal cord sparing were significantly improved in HAP (P < 0.001). Compared to KBP, HAP improved all indices, except for lung V5. Furthermore, the OAR sparing and target coverage between HAP and full manual planning were similar. Moreover, HAP had the shortest average planning time (57 min), when compared to KBP (63 min) and full manual planning (118 min). CONCLUSION HAP is an effective planning strategy for obtaining a high quality treatment plan for esophageal cancer.
Collapse
Affiliation(s)
- Chifang Ling
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China
| | - Xu Han
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China
| | - Peng Zhai
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China
| | - Hao Xu
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China
| | - Jiayan Chen
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China
| | - Jiazhou Wang
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China. .,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China.
| | - Weigang Hu
- Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China. .,Department of Oncology, Shanghai Medical College, Fudan University, 270 Dongan Road, Shanghai, 200032, China.
| |
Collapse
|
15
|
Dosimetric comparison and biological evaluation of PET- and CT-based target delineation for LA-NSCLC using auto-planning. Phys Med 2019; 67:77-84. [DOI: 10.1016/j.ejmp.2019.09.080] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 08/08/2019] [Accepted: 09/11/2019] [Indexed: 12/28/2022] Open
|
16
|
Zhang Q, Peng Y, Song X, Yu H, Wang L, Zhang S. Dosimetric evaluation of automatic and manual plans for early nasopharyngeal carcinoma to radiotherapy. Med Dosim 2019; 45:e13-e20. [PMID: 31466735 DOI: 10.1016/j.meddos.2019.05.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2019] [Accepted: 05/30/2019] [Indexed: 12/01/2022]
Abstract
To investigate dosimetric differences and plan qualities between manual plans and automatic plans for nasopharyngeal carcinoma (NPC) in early stage, and provide better options to maximize the benefits. Sixteen cases diagnosed with early NPC were retrospectively investigated. Conventional step and shoot IMRT with 7-fields and full arc volumetric-modulated arc therapy (VMAT) with double arcs were manually generated by experienced planners and automatically generated by Auto-Planning module in Pinnacle3 respectively, such as IMRT manual-planning (mIMRT), IMRT auto-planning (aIMRT), VMAT manual-planning (mVMAT), and VMAT auto-planning (aVMAT) for each patient. Target coverage, organs at risk sparing, monitor units, and planning times were compared and evaluated. All parameters of plans are able to fulfill International Commission on Radiation Units and Measurements repor (ICRU) 83 recommendations. Automatic plans are comparable or superior to manual plans without time-consuming planning process. The CI and HI for PTVs are better in aVMAT when compared with aIMRT and mVMAT, but those are similar between aIMRT and mVMAT. Automatic plans not only have superior dose homogeneity and conformity in PTVs, but also have better sparing for spinal cord or slightly reduce the doses received by other OARs, while the VMAT plans have better sparing for brain stem, especially the aVMAT plans. However, Dmax, V30, and V40 of brain stem are similar between aIMRT and mVMAT without significant difference. The monitor units and planning time for treatment plans have been significantly decreased through automatic planning technique. The automatic VMAT plan has greater clinical advantages and should be recommended to a better option for treating NPC in early stage, while automatic IMRT would be preferentially considered instead of manual VMAT.
Collapse
Affiliation(s)
- Quanbin Zhang
- Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095, China
| | - Yingying Peng
- Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095, China
| | - Xianlu Song
- Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095, China
| | - Hui Yu
- Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095, China
| | - Linjing Wang
- Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095, China
| | - Shuxu Zhang
- Affiliated Cancer Hospital & Institute of Guangzhou Medical University, Guangzhou 510095, China.
| |
Collapse
|
17
|
Sun WZ, Chen L, Yang X, Wang B, Deng XW, Huang XY. Comparison of treatment plan quality of VMAT for esophageal carcinoma with: flattening filter beam versus flattening filter free beam. J Cancer 2018; 9:3263-3268. [PMID: 30271485 PMCID: PMC6160692 DOI: 10.7150/jca.26044] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2018] [Accepted: 08/02/2018] [Indexed: 12/11/2022] Open
Abstract
Purpose: To investigate the difference in treatment plan quality of volumetric modulated arc treatment (VMAT) for esophageal carcinoma with flattening filter beam (FF) and flattening filter free beam (FFF). Material and methods: A total of fifty-six treatment plans were generated for twenty eight esophageal carcinoma patients with flattening filter beam and flattening filter free beam, using same optimal parameters. The homogeneity index (HI) and conformal index (CI) of targets, and some special points on Dose-Volume Histogram (DVH) curves were used to compare the plan quality. The coverage volumes of 45 Gy, 30 Gy and 20 Gy outside targets (V45Gy, V30Gy and V20Gy ) were used to compare the targets peripheral dose. The MU numbers, measured delivery time and averaged dose rates were used to evaluate the delivery efficiency of treatment plans. Results: A significant decreasing in peripheral dose around targets was found using FFF beams while the dose distributions in targets were equivalent to the plans with FF beams. V45Gy, V30Gy and V20Gy were decreased by 6.46%, 88.18% and 4.40%, respectively. A significant increase in MUs and decrease in treatment time were also found in delivery test. The average MUs was increased by 21.83% and the average treatment time was reduced by down to 11.9%. Conclusions: For esophageal carcinoma, the research showed that the treatment plans with FFF beams could get comparable dose distribution in targets and could significantly reduce the peripheral dose around targets compared to the plans with FF beams.
Collapse
Affiliation(s)
| | | | | | | | | | - Xiao-yan Huang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Department of Radiation Oncology, Sun Yat-sen University Cancer Center, Guangzhou, People's Republic of China
| |
Collapse
|