• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4624134)   Today's Articles (152)   Subscriber (49411)
For: Cristofolini L, Varini E, Pelgreffi I, Cappello A, Toni A. Device to measure intra-operatively the primary stability of cementless hip stems. Med Eng Phys 2006;28:475-82. [PMID: 16144768 DOI: 10.1016/j.medengphy.2005.07.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2005] [Revised: 07/18/2005] [Accepted: 07/19/2005] [Indexed: 11/29/2022]
Number Cited by Other Article(s)
1
Ex vivo estimation of cementless femoral stem stability using an instrumented hammer. Clin Biomech (Bristol, Avon) 2020;76:105006. [PMID: 32388077 DOI: 10.1016/j.clinbiomech.2020.105006] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 04/10/2020] [Accepted: 04/14/2020] [Indexed: 02/07/2023]
2
Chanda S, Mukherjee K, Gupta S, Pratihar DK. A comparative assessment of two designs of hip stem using rule-based simulation of combined osseointegration and remodelling. Proc Inst Mech Eng H 2019;234:118-128. [DOI: 10.1177/0954411919890998] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
3
Modal frequency and shape curvature as a measure of implant fixation: A computer study on the acetabular cup. Med Eng Phys 2018;60:30-38. [DOI: 10.1016/j.medengphy.2018.07.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 06/24/2018] [Accepted: 07/15/2018] [Indexed: 11/18/2022]
4
Impact Force, Polar Gap and Modal Parameters Predict Acetabular Cup Fixation: A Study on a Composite Bone. Ann Biomed Eng 2018;46:590-604. [DOI: 10.1007/s10439-018-1980-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 01/06/2018] [Indexed: 10/18/2022]
5
Tijou A, Rosi G, Hernigou P, Flouzat-Lachaniette CH, Haïat G. Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors. SENSORS 2017;18:s18010062. [PMID: 29280982 PMCID: PMC5796378 DOI: 10.3390/s18010062] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 12/14/2017] [Accepted: 12/23/2017] [Indexed: 11/16/2022]
6
Leuridan S, Goossens Q, Vander Sloten T, De Landsheer K, Delport H, Pastrav L, Denis K, Desmet W, Vander Sloten J. Vibration-based fixation assessment of tibial knee implants: A combined in vitro and in silico feasibility study. Med Eng Phys 2017;49:109-120. [DOI: 10.1016/j.medengphy.2017.08.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 07/07/2017] [Accepted: 08/13/2017] [Indexed: 10/18/2022]
7
Goossens Q, Leuridan S, Henyš P, Roosen J, Pastrav L, Mulier M, Desmet W, Denis K, Vander Sloten J. Development of an acoustic measurement protocol to monitor acetabular implant fixation in cementless total hip Arthroplasty: A preliminary study. Med Eng Phys 2017;49:28-38. [PMID: 28760407 DOI: 10.1016/j.medengphy.2017.07.006] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2016] [Revised: 04/24/2017] [Accepted: 07/12/2017] [Indexed: 11/27/2022]
8
Michel A, Bosc R, Sailhan F, Vayron R, Haiat G. Ex vivo estimation of cementless acetabular cup stability using an impact hammer. Med Eng Phys 2015;38:80-6. [PMID: 26671784 DOI: 10.1016/j.medengphy.2015.10.006] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Revised: 08/17/2015] [Accepted: 10/15/2015] [Indexed: 11/29/2022]
9
The collum femoris preserving stem: early results. Hip Int 2014;23:27-32. [PMID: 23397193 DOI: 10.5301/hip.2013.10718] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 11/15/2012] [Indexed: 02/04/2023]
10
Michel A, Bosc R, Mathieu V, Hernigou P, Haiat G. Monitoring the press-fit insertion of an acetabular cup by impact measurements: influence of bone abrasion. Proc Inst Mech Eng H 2014;228:1027-34. [PMID: 25258009 DOI: 10.1177/0954411914552433] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
11
Ruther C, Nierath H, Ewald H, Cunningham JL, Mittelmeier W, Bader R, Kluess D. Investigation of an acoustic-mechanical method to detect implant loosening. Med Eng Phys 2013;35:1669-75. [PMID: 23860369 DOI: 10.1016/j.medengphy.2013.06.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2012] [Revised: 06/04/2013] [Accepted: 06/23/2013] [Indexed: 10/26/2022]
12
Ruther C, Schulze C, Boehme A, Nierath H, Ewald H, Mittelmeier W, Bader R, Kluess D. Investigation of a passive sensor array for diagnosis of loosening of endoprosthetic implants. SENSORS 2012;13:1-20. [PMID: 23344370 PMCID: PMC3574661 DOI: 10.3390/s130100001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/23/2012] [Revised: 12/05/2012] [Accepted: 12/13/2012] [Indexed: 11/27/2022]
13
Ruther C, Ewald H, Mittelmeier W, Fritsche A, Bader R, Kluess D. A Novel Sensor Concept for Optimization of Loosening Diagnostics in Total Hip Replacement. J Biomech Eng 2011;133:104503. [DOI: 10.1115/1.4005222] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
14
Reggiani B, Cristofolini L, Taddei F, Viceconti M. Sensitivity of the Primary Stability of a Cementless Hip Stem to Its Position and Orientation. Artif Organs 2008;32:555-60. [DOI: 10.1111/j.1525-1594.2008.00577.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
15
Varini E, Cristofolini L, Traina F, Viceconti M, Toni A. Can the rasp be used to predict intra-operatively the primary stability that can be achieved by press-fitting the stem in cementless hip arthroplasty? Clin Biomech (Bristol, Avon) 2008;23:408-14. [PMID: 18068878 DOI: 10.1016/j.clinbiomech.2007.11.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/11/2007] [Revised: 09/25/2007] [Accepted: 11/02/2007] [Indexed: 02/07/2023]
16
Lannocca M, Varini E, Cappello A, Cristofolini L, Bialoblocka E. Intra-operative evaluation of cementless hip implant stability: A prototype device based on vibration analysis. Med Eng Phys 2007;29:886-94. [PMID: 17101289 DOI: 10.1016/j.medengphy.2006.09.011] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2006] [Revised: 09/19/2006] [Accepted: 09/24/2006] [Indexed: 10/23/2022]
17
Reggiani B, Cristofolini L, Varini E, Viceconti M. Predicting the subject-specific primary stability of cementless implants during pre-operative planning: Preliminary validation of subject-specific finite-element models. J Biomech 2007;40:2552-8. [PMID: 17229427 DOI: 10.1016/j.jbiomech.2006.10.042] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2005] [Accepted: 10/30/2006] [Indexed: 11/18/2022]
18
Varini E, Cristofolini L, Viceconti M, Traina F. Stem Damage During Implantation of Modular Hip Prostheses. Artif Organs 2006;30:564-7. [PMID: 16836740 DOI: 10.1111/j.1525-1594.2006.00261.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
PrevPage 1 of 1 1Next