Asciak L, Domingo-Roca R, Dow JR, Brodie R, Paterson N, Riches PE, Shu W, McCormick C. Exploiting light-based 3D-printing for the fabrication of mechanically enhanced, patient-specific aortic grafts. J Mech Behav Biomed Mater 2024; 154:106531. [PMID: 38588633 DOI: 10.1016/j.jmbbm.2024.106531] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 03/28/2024] [Accepted: 03/29/2024] [Indexed: 04/10/2024]
Abstract
Despite polyester vascular grafts being routinely used in life-saving aortic aneurysm surgeries, they are less compliant than the healthy, native human aorta. This mismatch in mechanical behaviour has been associated with disruption of haemodynamics contributing to several long-term cardiovascular complications. Moreover, current fabrication approaches mean that opportunities to personalise grafts to the individual anatomical features are limited. Various modifications to graft design have been investigated to overcome such limitations; yet optimal graft functionality remains to be achieved. This study reports on the development and characterisation of an alternative vascular graft material. An alginate:PEGDA (AL:PE) interpenetrating polymer network (IPN) hydrogel has been produced with uniaxial tensile tests revealing similar strength and stiffness (0.39 ± 0.05 MPa and 1.61 ± 0.19 MPa, respectively) to the human aorta. Moreover, AL:PE tubular conduits of similar geometrical dimensions to segments of the aorta were produced, either via conventional moulding methods or stereolithography (SLA) 3D-printing. While both fabrication methods successfully demonstrated AL:PE hydrogel production, SLA 3D-printing was more easily adaptable to the fabrication of complex structures without the need of specific moulds or further post-processing. Additionally, most 3D-printed AL:PE hydrogel tubular conduits sustained, without failure, compression up to 50% their outer diameter and returned to their original shape upon load removal, thereby exhibiting promising behaviour that could withstand pulsatile pressure in vivo. Overall, these results suggest that this AL:PE IPN hydrogel formulation in combination with 3D-printing, has great potential for accelerating progress towards personalised and mechanically-matched aortic grafts.
Collapse
Affiliation(s)
- Lisa Asciak
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Roger Domingo-Roca
- Department of Electronic and Electric Engineering, University of Strathclyde, Glasgow, UK
| | - Jamie R Dow
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK; Research and Development, Terumo Aortic Ltd., Inchinnan, Glasgow, UK
| | - Robbie Brodie
- Research and Development, Terumo Aortic Ltd., Inchinnan, Glasgow, UK
| | - Niall Paterson
- Research and Development, Terumo Aortic Ltd., Inchinnan, Glasgow, UK
| | - Philip E Riches
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Wenmiao Shu
- Department of Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | | |
Collapse
|
2
|
Vahabli E, Mann J, Heidari BS, Lawrence‐Brown M, Norman P, Jansen S, De‐Juan‐Pardo E, Doyle B. The Technological Advancement to Engineer Next-Generation Stent-Grafts: Design, Material, and Fabrication Techniques. Adv Healthc Mater 2022; 11:e2200271. [PMID: 35481675 PMCID: PMC11468507 DOI: 10.1002/adhm.202200271] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/04/2022] [Indexed: 12/12/2022]
Abstract
Endovascular treatment of aortic disorders has gained wide acceptance due to reduced physiological burden to the patient compared to open surgery, and ongoing stent-graft evolution has made aortic repair an option for patients with more complex anatomies. To date, commercial stent-grafts are typically developed from established production techniques with simple design structures and limited material ranges. Despite the numerous updated versions of stent-grafts by manufacturers, the reoccurrence of device-related complications raises questions about whether the current manfacturing methods are technically able to eliminate these problems. The technology trend to produce efficient medical devices, including stent-grafts and all similar implants, should eventually change direction to advanced manufacturing techniques. It is expected that through recent advancements, especially the emergence of 4D-printing and smart materials, unprecedented features can be defined for cardiovascular medical implants, like shape change and remote battery-free self-monitoring. 4D-printing technology promises adaptive functionality, a highly desirable feature enabling printed cardiovascular implants to physically transform with time to perform a programmed task. This review provides a thorough assessment of the established technologies for existing stent-grafts and provides technical commentaries on known failure modes. They then discuss the future of advanced technologies and the efforts needed to produce next-generation endovascular implants.
Collapse
Affiliation(s)
- Ebrahim Vahabli
- Vascular Engineering LaboratoryHarry Perkins Institute of Medical ResearchQEII Medical CentreNedlands and the UWA Centre for Medical ResearchThe University of Western AustraliaPerth6009Australia
- School of EngineeringThe University of Western AustraliaPerth6009Australia
| | - James Mann
- Vascular Engineering LaboratoryHarry Perkins Institute of Medical ResearchQEII Medical CentreNedlands and the UWA Centre for Medical ResearchThe University of Western AustraliaPerth6009Australia
- School of EngineeringThe University of Western AustraliaPerth6009Australia
| | - Behzad Shiroud Heidari
- Vascular Engineering LaboratoryHarry Perkins Institute of Medical ResearchQEII Medical CentreNedlands and the UWA Centre for Medical ResearchThe University of Western AustraliaPerth6009Australia
- School of EngineeringThe University of Western AustraliaPerth6009Australia
- Australian Research Council Centre for Personalised Therapeutics TechnologiesUniversity of Western AustraliaPerth6009Australia
| | | | - Paul Norman
- Vascular Engineering LaboratoryHarry Perkins Institute of Medical ResearchQEII Medical CentreNedlands and the UWA Centre for Medical ResearchThe University of Western AustraliaPerth6009Australia
- Medical SchoolThe University of Western AustraliaPerth6009Australia
| | - Shirley Jansen
- Curtin Medical SchoolCurtin UniversityPerthWA6102Australia
- Department of Vascular and Endovascular SurgerySir Charles Gairdner HospitalPerthWA6009Australia
- Heart and Vascular Research InstituteHarry Perkins Medical Research InstitutePerthWA6009Australia
| | - Elena De‐Juan‐Pardo
- School of EngineeringThe University of Western AustraliaPerth6009Australia
- T3mPLATEHarry Perkins Institute of Medical ResearchQEII Medical CentreNedlands and the UWA Centre for Medical ResearchThe University of Western AustraliaPerthWA6009Australia
- School of Mechanical, Medical and Process EngineeringQueensland University of TechnologyBrisbaneQueensland4059Australia
| | - Barry Doyle
- Vascular Engineering LaboratoryHarry Perkins Institute of Medical ResearchQEII Medical CentreNedlands and the UWA Centre for Medical ResearchThe University of Western AustraliaPerth6009Australia
- School of EngineeringThe University of Western AustraliaPerth6009Australia
- Australian Research Council Centre for Personalised Therapeutics TechnologiesUniversity of Western AustraliaPerth6009Australia
- British Heart Foundation Centre for Cardiovascular ScienceThe University of EdinburghEdinburghEH16 4TJUK
| |
Collapse
|
3
|
Liberski A, Ayad N, Wojciechowska D, Kot R, Vo DM, Aibibu D, Hoffmann G, Cherif C, Grobelny-Mayer K, Snycerski M, Goldmann H. Weaving for heart valve tissue engineering. Biotechnol Adv 2017; 35:633-656. [DOI: 10.1016/j.biotechadv.2017.07.012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Revised: 07/30/2017] [Accepted: 07/31/2017] [Indexed: 10/19/2022]
|
4
|
Singh C, Wang X, Morsi Y, Wong CS. Importance of stent-graft design for aortic arch aneurysm repair. AIMS BIOENGINEERING 2017. [DOI: 10.3934/bioeng.2017.1.133] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
|
5
|
Singh C, Wong CS, Wang X. Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries. J Funct Biomater 2015; 6:500-25. [PMID: 26133386 PMCID: PMC4598668 DOI: 10.3390/jfb6030500] [Citation(s) in RCA: 99] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2015] [Revised: 06/18/2015] [Accepted: 06/18/2015] [Indexed: 02/06/2023] Open
Abstract
Vascular implants belong to a specialised class of medical textiles. The basic purpose of a vascular implant (graft and stent) is to act as an artificial conduit or substitute for a diseased artery. However, the long-term healing function depends on its ability to mimic the mechanical and biological behaviour of the artery. This requires a thorough understanding of the structure and function of an artery, which can then be translated into a synthetic structure based on the capabilities of the manufacturing method utilised. Common textile manufacturing techniques, such as weaving, knitting, braiding, and electrospinning, are frequently used to design vascular implants for research and commercial purposes for the past decades. However, the ability to match attributes of a vascular substitute to those of a native artery still remains a challenge. The synthetic implants have been found to cause disturbance in biological, biomechanical, and hemodynamic parameters at the implant site, which has been widely attributed to their structural design. In this work, we reviewed the design aspect of textile vascular implants and compared them to the structure of a natural artery as a basis for assessing the level of success as an implant. The outcome of this work is expected to encourage future design strategies for developing improved long lasting vascular implants.
Collapse
Affiliation(s)
- Charanpreet Singh
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
| | - Cynthia S Wong
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
| | - Xungai Wang
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia.
- School of Textile Science and Engineering, Wuhan Textile University, Wuhan 430073, China.
| |
Collapse
|
6
|
Fahy P, Delassus P, McCarthy P, Sultan S, Hynes N, Morris L. An In Vitro Assessment of the Cerebral Hemodynamics Through Three Patient Specific Circle of Willis Geometries. J Biomech Eng 2013; 136:011007. [DOI: 10.1115/1.4025778] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2013] [Indexed: 11/08/2022]
Abstract
The Circle of Willis (CoW) is a complex pentagonal network comprised of fourteen cerebral vessels located at the base of the brain. The collateral flow feature within the circle of Willis allows the ability to maintain cerebral perfusion of the brain. Unfortunately, this collateral flow feature can create undesirable flow impact locations due to anatomical variations within the CoW. The interaction between hemodynamic forces and the arterial wall are believed to be involved in the formation of cerebral aneurysms, especially at irregular geometries such as tortuous segments, bends, and bifurcations. The highest propensity of aneurysm formation is known to form at the anterior communicating artery (AcoA) and at the junctions of the internal carotid and posterior communicating arteries (PcoAs). Controversy still remains as to the existence of blood flow paths through the communicating arteries for a normal CoW. This paper experimentally describes the hemodynamic conditions through three thin walled patient specific models of a complete CoW based on medical images. These models were manufactured by a horizontal dip spin coating method and positioned within a custom made cerebral testing system that simulated symmetrical physiological afferent flow conditions through the internal carotid and vertebral arteries. The dip spin coating procedure produced excellent dimensional accuracy. There was an average of less than 4% variation in diameters and wall thicknesses throughout all manufactured CoW models. Our cerebral test facility demonstrated excellent cycle to cycle repeatability, with variations of less than 2% and 1% for the time and cycle averaged flow rates, respectively. The peak systolic flow rates had less than a 4% variation. Our flow visualizations showed four independent flow sources originating from all four inlet arteries impacting at and crossing the AcoA with bidirectional cross flows. The flow paths entering the left and right vertebral arteries dissipated throughout the CoW vasculature from the posterior to anterior sides, exiting through all efferent vessels. Two of the models had five flow impact locations, while the third model had an additional two impact locations within the posterior circulation caused by an additional bidirectional cross flows along the PcoAs during the accelerating and part of the decelerating phases. For a complete CoW, bidirectional cross flows exist within the AcoA and geometrical variations within the CoW geometry can either promote uni- or bidirectional cross flows along the PcoAs.
Collapse
Affiliation(s)
| | - Patrick Delassus
- Galway Medical Technologies Centre (GMedTech), Department of Mechanical and Industrial Engineering, Galway Mayo Institute of Technology, Dublin Road, Galway,Ireland
| | - Peter McCarthy
- Department of Diagnostic Radiology, University Hospital, Newcastle Road, Galway,Ireland
| | - Sheriff Sultan
- Department of Vascular and Endovascular Surgery, Western Vascular Institute, University Hospital, Newcastle Road, Galway,Ireland
- Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Galway, Ireland
| | - Niamh Hynes
- Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Galway,Ireland
| | - Liam Morris
- Galway Medical Technologies Centre (GMedTech), Department of Mechanical and Industrial Engineering, Galway Mayo Institute of Technology, Dublin Road, Galway,Ireland e-mail:
| |
Collapse
|
7
|
Singh C, Wang X. A biomimetic approach for designing stent-graft structures: Caterpillar cuticle as design model. J Mech Behav Biomed Mater 2013; 30:16-29. [PMID: 24216309 DOI: 10.1016/j.jmbbm.2013.10.014] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2013] [Revised: 10/09/2013] [Accepted: 10/13/2013] [Indexed: 10/26/2022]
Abstract
Stent-graft (SG) induced biomechanical mismatch at the aortic repair site forms the major reason behind postoperative hemodynamic complications. These complications arise from mismatched radial compliance and stiffness property of repair device relative to native aortic mechanics. The inability of an exoskeleton SG design (an externally stented rigid polyester graft) to achieve optimum balance between structural robustness and flexibility constrains its biomechanical performance limits. Therefore, a new SG design capable of dynamically controlling its stiffness and flexibility has been proposed in this study. The new design is adopted from the segmented hydroskeleton structure of a caterpillar cuticle and comprises of high performance polymeric filaments constructed in a segmented knit architecture. Initially, conceptual design models of caterpillar and SG were developed and later translated into an experimental SG prototype. The in-vitro biomechanical evaluation (compliance, bending moment, migration intensity, and viscoelasticity) revealed significantly better performance of hydroskeleton structure than a commercial SG device (Zenith(™) Flex SG) and woven Dacron(®) graft-prosthesis. Structural segmentation improved the biomechanical behaviour of new SG by inducing a three dimensional volumetric expansion property when the SG was subjected to hoop stresses. Interestingly, this behaviour matches the orthotropic elastic property of native aorta and hence proposes segmented hydroskeleton structures as promising design approach for future aortic repair devices.
Collapse
Affiliation(s)
- Charanpreet Singh
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia
| | - Xungai Wang
- Australian Future Fibres Research and Innovation Centre, Institute for Frontier Materials, Deakin University, Geelong, VIC 3216, Australia; Ministry of Education Key Laboratory for Textile Fibers and Products, Wuhan Textile University, Wuhan 430073, China.
| |
Collapse
|
8
|
Liu JF, Jiang WL, Lu HT, Li YL, Zhang TH, Yamakawa T. Application of protective stents in endovascular repair of acute complicated Stanford type B aortic dissections. J Endovasc Ther 2013; 20:210-8. [PMID: 23581765 DOI: 10.1583/1545-1550-20.2.210] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
PURPOSE To describe the use of protective stents in the endovascular repair of acute complicated Stanford type B aortic dissections. METHODS From 2009 to 2011, 33 patients (27 men; mean age 47 years, range 31-73) with acute complicated Stanford type B aortic dissection underwent thoracic endovascular aortic repair (TEVAR) assisted by protective stents. In all cases, the proximal and distal landing zones differed in size by >5 mm, and the primary entry tear was in the proximal descending aorta. A bare self-expanding stent (protective stent) was deployed initially at the intended distal landing site of the primary stent-graft in the true lumen. The intention was that the bare stent would prevent excessive dilation of the distal end of the stent-graft in the vicinity of the entry tear, thus avoiding intimal rupture. RESULTS Successful stent deployment and sealing of the entry tear was achieved in all patients. The median diameter and length of the protective bare stents was 20.3 mm (range 18-24) and 72.7 mm (range 60-80), respectively, while the corresponding dimensions of the covered stent-grafts were 32.8 mm (range 26-40) and 157.4 mm (range 120-200 mm), respectively. There was no stent twisting, migration, of rupture of the false or true lumen. Computed tomography 1 week postoperatively demonstrated closure of the primary entry tear with thrombosis of the false lumen in all cases. No patients were lost to follow-up, which has ranged from 3 months to 3 years. No late endoleaks or stent complications, such as angulation, dislodgment, persistent leaks, branch obstruction, or stent-graft migration, have been observed, and there has been no chronic progressive true or false lumen dilatation, recurrences, or deaths. CONCLUSION Adjunctive use of a protective stent when treating acute Stanford type B aortic dissections in which the diameters of the proximal and distal landing zones differ by >5 mm is feasible and safe and provides good short-term outcomes.
Collapse
Affiliation(s)
- Jian Feng Liu
- Department of Neurology, First Affiliated Hospital of Harbin Medical University, Harbin, China
| | | | | | | | | | | |
Collapse
|
9
|
Corbett TJ, Molony DS, Callanan A, McGloughlin TM. The effect of vessel material properties and pulsatile wall motion on the fixation of a proximal stent of an endovascular graft. Med Eng Phys 2010; 33:106-11. [PMID: 20947409 DOI: 10.1016/j.medengphy.2010.09.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2009] [Revised: 09/21/2010] [Accepted: 09/22/2010] [Indexed: 10/18/2022]
Abstract
Migration is a serious failure mechanism associated with endovascular abdominal aortic aneurysm (AAA) repair (EVAR). The effect of vessel material properties and pulsatile wall motion on stent fixation has not been previously investigated. A proximal stent from a commercially available stent graft was implanted into the proximal neck of silicone rubber abdominal aortic aneurysm models of varying proximal neck stiffness (β=25.39 and 20.44). The stent was then dislodged by placing distal force on the stent struts. The peak force to completely dislodge the stent was measured using a loadcell. Dislodgment was performed at ambient pressure with no flow (NF) and during pulsatile flow (PF) at pressures of 120/80 mmHg and 140/100 mmHg to determine if pulsatile wall motions affected the dislodgement force. An imaging analysis was performed at ambient pressure and at pressures of 120 mmHg and 140 mmHg to investigate diameter changes on the model due to the radial force of the stent and internal pressurisation. Stent displacement forces were ~50% higher in the stiffer model (7.16-8.4 N) than in the more compliant model (3.67-4.21 N). The mean displacement force was significantly reduced by 10.95-12.83% from the case of NF to the case of PF at 120/80 mmHg. A further increase in pressure to 140/120 mmHg had no significant effect on the displacement force. The imaging analysis showed that the diameter in the region of the stent was 0.37 mm greater in the less stiff model at all the pressures which could reduce the fixation of the stent. The results suggest that the fixation of passively fixated aortic stents could be comprised in more compliant walls and that pulsatile motions of the wall can reduce the maximum stent fixation.
Collapse
Affiliation(s)
- T J Corbett
- Centre for Applied Biomedical Engineering Research (CABER), MSSi, Department of Mechanical and Aeronautical Engineering, University of Limerick, Limerick, Ireland
| | | | | | | |
Collapse
|
10
|
Corbett TJ, Doyle BJ, Callanan A, Walsh MT, McGloughlin TM. Engineering silicone rubbers for in vitro studies: creating AAA models and ILT analogues with physiological properties. J Biomech Eng 2010; 132:011008. [PMID: 20524746 DOI: 10.1115/1.4000156] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In vitro studies of abdominal aortic aneurysm (AAA) have been widely reported. Frequently mock artery models with intraluminal thrombus (ILT) analogs are used to mimic the in vivo AAA. While the models used may be physiological, their properties are frequently either not reported or investigated. This study is concerned with the testing and characterization of previously used vessel analog materials and the development of new materials for the manufacture of AAA models. These materials were used in conjunction with a previously validated injection molding technique to manufacture AAA models of ideal geometry. To determine the model properties (stiffness (beta) and compliance), the diameter change of each AAA model was investigated under incrementally increasing internal pressures and compared with published in vivo studies to determine if the models behaved physiologically. A FEA study was implemented to determine if the pressure-diameter change behavior of the models could be predicted numerically. ILT analogs were also manufactured and characterized. Ideal models were manufactured with ILT analog internal to the aneurysm region, and the effect of the ILT analog on the model compliance and stiffness was investigated. The wall materials had similar properties (E(init) 2.22 MPa and 1.57 MPa) to aortic tissue at physiological pressures (1.8 MPa (from literature)). ILT analogs had a similar Young's modulus (0.24 MPa and 0.33 MPa) to the medial layer of ILT (0.28 MPa (from literature)). All models had aneurysm sac compliance (2.62-8.01 x 10(-4)/mm Hg) in the physiological range (1.8-9.4 x 10(-4)/mm Hg (from literature)). The necks of the AAA models had similar stiffness (20.44-29.83) to healthy aortas (17.5+/-5.5 (from literature)). Good agreement was seen between the diameter changes due to pressurization in the experimental and FEA wall models with a maximum difference of 7.3% at 120 mm Hg. It was also determined that the inclusion of ILT analog in the sac of the models could have an effect on the compliance of the model neck. Ideal AAA models with physiological properties were manufactured. The behavior of these models due to pressurization was predicted using finite element analysis, validating this technique for the future design of realistic physiological AAA models. Addition of ILT analogs in the aneurysm sac was shown to affect neck behavior. This could have implications for endovascular AAA repair due to the importance of the neck for stent-graft fixation.
Collapse
Affiliation(s)
- T J Corbett
- Centre for Applied Biomedical Engineering Research (CABER), Department of Mechanical and Aeronautical Engineering, MSSi, University of Limerick, Limerick, Ireland
| | | | | | | | | |
Collapse
|
11
|
Corbett TJ, Callanan A, O'Donnell MR, McGloughlin TM. An Improved Methodology for Investigating the Parameters Influencing Migration Resistance of Abdominal Aortic Stent-Grafts. J Endovasc Ther 2010; 17:95-107. [DOI: 10.1583/09-2920.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
12
|
Molony DS, Callanan A, Morris LG, Doyle BJ, Walsh MT, McGloughlin TM. Geometrical Enhancements for Abdominal Aortic Stent-Grafts. J Endovasc Ther 2008; 15:518-29. [DOI: 10.1583/08-2388.1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|