1
|
Reiss S, Wäscher K, Caglar Özen A, Lottner T, Timo Heidt, von Zur Mühlen C, Bock M. Quantifying myocardial perfusion during MR-guided interventions without exogenous contrast agents: intra-arterial spin labeling. Z Med Phys 2023:S0939-3889(23)00002-8. [PMID: 36717310 DOI: 10.1016/j.zemedi.2023.01.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/05/2023] [Accepted: 01/05/2023] [Indexed: 01/30/2023]
Abstract
PURPOSE To test intra-arterial spin labeling (iASL) using active guiding catheters for myocardial perfusion measurements during magnetic resonance (MR)-guided interventions in a pig study. METHODS In this work, a single-loop radiofrequency (RF) coil at the tip of a 6F active coronary catheter was used as a transmit coil for local spin labeling. The transmit magnetic RF field (B1) of the coil and the labeling efficiency were determined, and iASL was tested in two pigs after the catheter was engaged in the aortic root, the ostium of the left coronary artery (LCA) under MR-guidance. The iASL effect was assessed by the signal difference between spin-labeling On and control (spin-labeling OFF) images, and in a cross-correlation between ON/Off states of spin-labeling a binary labeling paradigm. In addition, quantitative myocardial perfusion was calculated from the iASL experiments. RESULTS The maximum B1 in the vicinity of the catheter coil was 2.1 µT. A strong local labeling effect with a labeling efficiency of 0.45 was achieved with iASL both in vitro and in vivo. In both pigs, the proximal myocardial segments supplied by the LCA showed significant labelling effect up to distances of 60 mm from the aortic root with a relative signal difference of (3.14 ± 2.89)% in the first and (3.50 ± 1.25)% in the second animal. The mean correlation coefficients were R = 0.63 ± 0.22 and 0.42 ± 0.16, respectively. The corresponding computed myocardial perfusion values in this region of the myocardium were similar to those obtained with contrast perfusion methods ((1.2 ± 1.1) mL/min/g and (0.8 ± 0.6) mL/min/g). CONCLUSION The proposed iASL method demonstrates the feasibility of selective myocardial perfusion measurements during MR-guided coronary interventions, which with further technical improvements may provide an alternative to exogenous contrast-based perfusion. Due to the invasive nature of the iASL method, it can potentially be used in concert with MRI-guided coronary angioplasty.
Collapse
Affiliation(s)
- Simon Reiss
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Kevin Wäscher
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ali Caglar Özen
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Thomas Lottner
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Timo Heidt
- Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Constantin von Zur Mühlen
- Department of Cardiology and Angiology I, University Heart Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Department of Diagnostic and Interventional Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
2
|
Cong M, Zhao H, Dai S, Chen C, Xu X, Qiu J, Qin S. Transient numerical simulation of the right coronary artery originating from the left sinus and the effect of its acute take-off angle on hemodynamics. Quant Imaging Med Surg 2021; 11:2062-2075. [PMID: 33936987 DOI: 10.21037/qims-20-125] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background An anomalous origin of the right coronary artery from the left coronary artery sinus is usually characterized by an acute take-off angle. Most affected patients have no clinical symptoms; however, some patients have decreased blood flow into the right coronary artery during exercise, which can lead to symptoms such as myocardial ischemia. Most researchers who have studied an anomalous origin of the right coronary artery from the left coronary artery sinus have done so through clinical cases. In this study, we used numerical simulation to evaluate the hemodynamics of this condition and the effect of an acute take-off angle on hemodynamic parameters. We expect that the results of this study will help in further understanding the clinical symptoms of this anomaly and the hemodynamic impact of an acute take-off angle. Methods Three-dimensional models were reconstructed based on the computed tomography images from 16 patients with a normal right coronary artery and 26 patients with an anomalous origin of the right coronary artery from the left coronary artery sinus. A numerical simulation of a two-way fluid-structure interaction was executed with ANSYS Workbench software. The blood was assumed to be an incompressible Newtonian fluid, and the vessel was assumed to be an isotropic, linear elastic material. Hemodynamic parameters and the effect of an acute take-off angle were statistically analyzed. Results During the systolic period, the wall pressure in the right coronary artery was significantly reduced in patients with an anomalous origin of the right coronary artery (t =1.32 s, P=0.0001; t =1.34-1.46 s, P<0.0001). The wall shear stress in the abnormal group was higher at the beginning of the systolic period (t =1.24 s, P=0.0473; t =1.26 s, P=0.0193; t =1.28 s, P=0.0441). The acute take-off angle was smaller in patients with clinical symptoms (27.81°±4.406°) than in patients without clinical symptoms (31.86°±2.789°; P=0.017). In the symptomatic group, pressure was negatively correlated with the acute take-off angle (P=0.0185-0.0341, r=-0.459 to -0.4167). Conclusions This study shows that an anomalous origin of the right coronary artery from the left coronary artery sinus causes changes in hemodynamic parameters, and that an acute take-off angle in patients with this anomaly is associated with terminal ischemia of the right coronary artery.
Collapse
Affiliation(s)
- Mengyang Cong
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, China
| | - Huihui Zhao
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.,Center for Medical Engineer Technology Research, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China
| | - Shun Dai
- Department of Radiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Chuanzhi Chen
- Department of Radiology, East Hospital, Tongji University School of Medicine, Shanghai, China
| | - Xingming Xu
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Tai'an, China
| | - Jianfeng Qiu
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China.,Center for Medical Engineer Technology Research, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, China
| | - Shengxue Qin
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, China
| |
Collapse
|
3
|
Cong M, Xu X, Qiu J, Dai S, Chen C, Qian X, Zhang H, Qin S, Zhao H. Influence of malformation of right coronary artery originating from the left sinus in hemodynamic environment. Biomed Eng Online 2020; 19:59. [PMID: 32727522 PMCID: PMC7392689 DOI: 10.1186/s12938-020-00804-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 07/23/2020] [Indexed: 11/11/2022] Open
Abstract
Background The anomalous origin of the right coronary artery (RCA) from the left coronary artery sinus (AORL) is one of the abnormal origins of the coronary arteries. Most of these issues rarely have any effects on human health, but some individuals may exhibit symptoms, such as myocardial ischemia or even sudden death. Recently, researchers have investigated the AORL through clinical cases, but studies based on computational fluid dynamics (CFD) have rarely been reported. In this study, the hemodynamic changes between the normal origin of the RCA and the AORL are compared based on numerical simulation results. Methods Realistic three-dimensional (3D) models of the 16 normal right coronary arteries and 26 abnormal origins of the RCAs were constructed, respectively. The blood flow was numerically simulated using the ANSYS software. This study used a one-way fluid–solid coupling finite element model, wherein the blood is assumed to be an incompressible Newtonian fluid, and the vessel is assumed to be made of an isotropic linear elastic material. Results The cross-sectional area differences between the inlet of the normal group and that of the abnormal group were significant (P < 0.0001). Moreover, there were significant differences in the volumetric flow (P = 0.0001) and pressure (P = 0.0002). Positive correlation exists for the ratio of the cross-sectional area of the RCA to the inlet area of the ascending aorta (AAO), and the ratio of the inlet volumetric flow of the RCA to the volumetric flow of the AAO, in the normal (P = 0.0001, r = 0.8178) and abnormal (P = 0.0033, r = 0.6107) groups. Conclusion This study demonstrates that the cross-sectional area of the AORL inlet may cause ischemia symptoms. The results obtained by this study may contribute to the further understanding of the clinical symptoms of the AORL based on the hemodynamics.
Collapse
Affiliation(s)
- Mengyang Cong
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, 266590, China
| | - Xingming Xu
- Intelligent Equipment College, Shandong University of Science and Technology, Taian, 271016, China
| | - Jianfeng Qiu
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China.,Center for Medical Engineer Technology Research, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China
| | - Shun Dai
- Department of Radiology, Shanghai Tong Ren Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, 200120, China
| | - Chuanzhi Chen
- Department of Radiology, East Hospital, Tongji University School of Medicine, Shanghai, 200120, China
| | - Xiuqing Qian
- Department of Biomedical engineering, Capital Medical University, Beijing, 10060, China
| | - Hongbin Zhang
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, 266590, China
| | - Shengxue Qin
- College of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao, 266590, China.
| | - Huihui Zhao
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China. .,Center for Medical Engineer Technology Research, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China.
| |
Collapse
|
4
|
Influence of Artery Straightening on Local Hemodynamics in Left Anterior Descending (LAD) Artery after Stent Implantation. Cardiol Res Pract 2020; 2020:6970817. [PMID: 32550022 PMCID: PMC7261340 DOI: 10.1155/2020/6970817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Accepted: 04/20/2020] [Indexed: 11/29/2022] Open
Abstract
Objectives The study investigates local hemodynamic environment changes caused by straightening phenomenon and the relationship between straightening phenomenon and in-stent restenosis. Background Intravascular intervention is an effective treatment in restoring the normal flow conditions and vascular lumen. Unfortunately, in-stent restenosis often occurs in a subset of patients after stent implantation and limits the success of stent implantation outcomes. The implanted stent usually causes artery straightening locally, rather than coinciding and adjusting to the physiological curve exactly. Artery straightening would apparently modify the artery geometry and therefore alter the local hemodynamic environment, which may result in intimal hyperplasia and restenosis after stenting implantation. Methods In the current investigation, we verify the hypothesis that the artery straightening influences the local hemodynamic state using the different 3D CT models. Flow analysis for blood in the left anterior descending coronary artery and the straightening model is simulated numerically. Result The current results reveal that the straightening phenomenon alters the distribution of wall shear stress and flow patterns, decreases the wall shear stress (WSS), and increases the oscillatory shear index (OSI) and the relative residence time (RRT), especially at the proximal and distal areas of stenting. Conclusions The local straightened geometry established after stent implantation was likely to generate portions of the stenting area to a high risk of neointimal hyperplasia and subsequent restenosis.
Collapse
|
5
|
Yeung C, Baranchuk A, Tse G, Liu T. The Importance of Measuring Coronary Blood Flow for Clinical Decision Making. Curr Cardiol Rev 2019; 15:320-321. [PMID: 31456513 PMCID: PMC8142358 DOI: 10.2174/1573403x1504190819123137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Affiliation(s)
| | | | - Gary Tse
- Department of Medicine and Therapeutics, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China.,Li Ka Shing Institute of Health Sciences, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China
| | - Tong Liu
- Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin, China
| |
Collapse
|
6
|
Shen X, Zhu H, Ji S, Jiang J, Deng Y. Fatigue behavior of stent in tapered arteries: The role of arterial tapering and stent material. Proc Inst Mech Eng H 2019; 233:989-998. [PMID: 31277553 DOI: 10.1177/0954411919862400] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Stenting has achieved great success in treating cardiovascular diseases due to its high efficiency and minimal invasiveness. However, fatigue of stents severely limits its long-term outcome. In this article, finite element method was adopted to study the effects of arterial tapering and stent material on the fatigue performance of stents. A series of tapered vessels with different taper levels and two sets of stents with different materials were modeled. The Goodman diagram was used to evaluate the fatigue resistance of stents. Results showed that the fatigue resistance of stents can be extremely improved by simply changing stent material. In addition, the taper of the arteries had an important influence on the fatigue resistance of the stent. The fatigue life of the stent will be shortened with the increase of the arterial taper. The method that predicted stent fatigue life in tapered vessels can help clinicians select stents that are more suitable for tapered vessels and help stent engineers design stents that are more resistant to fatigue.
Collapse
Affiliation(s)
- Xiang Shen
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Hongfei Zhu
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Song Ji
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Jiabao Jiang
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| | - Yongquan Deng
- School of Mechanical Engineering, Jiangsu University, Zhenjiang, China
| |
Collapse
|
7
|
Hawthorn A, Bulmer AC, Mosawy S, Keogh S. Implications for maintaining vascular access device patency and performance: Application of science to practice. J Vasc Access 2019; 20:461-470. [DOI: 10.1177/1129729818820200] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Introduction:Vascular access devices are commonly inserted devices that facilitate the administration of fluids and drugs, as well as blood sampling. Despite their common use in clinical settings, these devices are prone to occlusion and failure, requiring replacement and exposing the patient to ongoing discomfort/pain, local vessel inflammation and risk of infection. A range of insertion and maintenance strategies are employed to optimize device performance; however, the evidence base for many of these mechanisms is limited and the mechanisms contributing to the failure of these devices are largely unknown.Aims/objectives:(1) To revisit existing understanding of blood, vessel physiology and biological fluid dynamics; (2) develop an understanding of the implications that different clinical practices have on vessel health, and (3) apply these understandings to vascular access device research and practice.Method:Narrative review of biomedical and bioengineering studies related to vascular access practice.Results/outcomes:Current vascular access device insertion and maintenance practice and policy are variable with limited clinical evidence to support the theoretical assumptions underpinning these regimens. This review demonstrates the physiological response to vascular access device insertion, flushing and infusion on the vein, blood components and blood flow. These appear to be associated with changes in intravascular fluid dynamics. Variable forces are at play that impact blood componentry and the endothelium. These may explain the mechanisms contributing to vascular access failure.Conclusion:This review provides an update to our current knowledge and understanding of vascular physiology and the hemodynamic response, challenging some previously held assumptions regarding vascular access device maintenance, which require further investigation.
Collapse
Affiliation(s)
- Alexandra Hawthorn
- School of Nursing, Queensland University of Technology, Brisbane, QLD, Australia
- School of Medicine, Griffith University, Brisbane, QLD, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| | - Andrew C Bulmer
- School of Medicine, Griffith University, Brisbane, QLD, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| | - Sapha Mosawy
- School of Medicine, Griffith University, Brisbane, QLD, Australia
| | - Samantha Keogh
- School of Nursing, Queensland University of Technology, Brisbane, QLD, Australia
- Alliance for Vascular Access Teaching and Research (AVATAR), Menzies Health Institute Queensland, Griffith University, Brisbane, QLD, Australia
| |
Collapse
|
8
|
Peng L, Qiu Y, Huang Z, Xia C, Dai C, Zheng T, Li Z. Numerical Simulation of Hemodynamic Changes in Central Veins after Tunneled Cuffed Central Venous Catheter Placement in Patients under Hemodialysis. Sci Rep 2017; 7:15955. [PMID: 29162830 PMCID: PMC5698485 DOI: 10.1038/s41598-017-12456-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Accepted: 09/08/2017] [Indexed: 02/05/2023] Open
Abstract
The tunneled central venous catheter (CVC) plays an important role for hemodialysis patients, but CVC-related thrombosis in the central veins remain problematic. This study is the first try to numerically find out what hemodynamic parameters are predisposed to the initiation and formation of thrombus after CVC insertion. And the potential relationship between hemodynamic parameters and the incidence rates of thrombosis occurrence was explored. The results revealed that the CVC insertion led to a significant increase of hydraulic resistance, wide-ranging abnormally high wall shear stress (WSS), and a great loss of flow rotation in the vein. Moreover, the clinical data showed that thrombosis mainly occurred at sections where most blood flow lost spiral rotation after the CVC insertion, but no corresponding match was observed between the occurrence of thrombosis and the flow velocity or WSS. We speculate that the destruction of the flow rotation in the central vein is a precursor to the thrombus formation around CVC, and an introduction of spiral flow with the CVC insertion may possibly help to protect the central vein from thrombosis. Further animal and clinical experiments should be carried out to test and verify this speculation.
Collapse
Affiliation(s)
- Liqing Peng
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Yue Qiu
- Department of Applied Mechanics, Sichuan University, Chengdu, 610065, China
| | - Zhongyi Huang
- Department of Applied Mechanics, Sichuan University, Chengdu, 610065, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, China
- Vascular Surgery Department, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Chenzhong Dai
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, China
| | - Tinghui Zheng
- Department of Applied Mechanics, Sichuan University, Chengdu, 610065, China.
| | - Zhenlin Li
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, 610041, China.
| |
Collapse
|