Müller B, Elrod J, Pensalfini M, Hopf R, Distler O, Schiestl C, Mazza E. A novel ultra-light suction device for mechanical characterization of skin. PLoS One 2018; 13:e0201440. [PMID: 30089132 PMCID: PMC6082559 DOI: 10.1371/journal.pone.0201440] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Accepted: 07/16/2018] [Indexed: 01/19/2023] Open
Abstract
Suction experiments have been extensively applied for skin characterization. In these tests the deformation behavior of superficial tissue layers determines the elevation of the skin surface observed when a predefined negative (suction) pressure history is applied. The ability of such measurements to differentiate between skin conditions is limited by the variability of the elevation response observed in repeated experiments. The scatter was shown to be associated with the force exerted by the observer when holding the instrument against the skin. We have developed a novel suction device and a measurement procedure aiming at a tighter control of mechanical boundary conditions during the experiments. The new device weighs only 3.5 g and thus allows to minimize the force applied on the skin during the test. In this way, it is possible to reliably characterize the mechanical response of skin, also in case of low values of suction pressure and deformation. The influence of the contact force is analyzed through experiments on skin and synthetic materials, and rationalized based on corresponding finite element calculations. A comparative study, involving measurements on four body locations in two subjects by three observers, showed the good performance of the new procedure, specific advantages, and limitations with respect to the Cutometer®, i.e. the suction device most widely applied for skin characterization. As a byproduct of the present investigation, a correction procedure is proposed for the Cutometer measurements, which allows to partially compensate for the influence of the contact force. The characteristics of the new suction method are discussed in view of future applications for diagnostic purposes.
Collapse
Affiliation(s)
- Bettina Müller
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Julia Elrod
- Department of Surgery, University Children’s Hospital Zurich, Zurich, Switzerland
| | - Marco Pensalfini
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Raoul Hopf
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
| | - Oliver Distler
- Department of Rheumatology, University Hospital Zurich, Zurich, Switzerland
| | - Clemens Schiestl
- Department of Surgery, University Children’s Hospital Zurich, Zurich, Switzerland
| | - Edoardo Mazza
- Institute for Mechanical Systems, Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland
- Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf, Switzerland
- * E-mail:
| |
Collapse
|
2
|
ELAHI SEYEDALI, CONNESSON NATHANAEL, PAYAN YOHAN. DISPOSABLE SYSTEM FOR IN-VIVO MECHANICAL CHARACTERIZATION OF SOFT TISSUES BASED ON VOLUME MEASUREMENT. J MECH MED BIOL 2018. [DOI: 10.1142/s0219519418500379] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
In-vivo characterization of soft tissues is a key step toward biomechanical simulation and planning of intra-operative assisted surgery. To achieve this, aspiration method is a standard technique: tissue is aspirated through a hole while measuring the pressure and associated apex height. An inverse problem is then solved to identify the material mechanical properties. In the literature, the apex height is usually measured using a camera, which induces design difficulties, in particular in regards on the required sterilization process for in-vivo measurements. In this paper, the idea is to replace the apex height optical measurement by the measurement of the aspirated tissue volume. The proposed method enables to reduce the system head to a simple tube: sterilizations becomes easy and the system is disposable after use. The proposed system is thus the simplest, lightest and cheapest one could achieve. It is also to the authors knowledge the first time ever in aspiration method that the aspired volume is the extracted data. As the data signal-to-noise ratio is the main factor impacting any applied inverse method when extracting the mechanical properties, the aim of this work is to assess and compare the experimental signal-to-noise ratio in the raw volume measurements obtained either optically or with the method proposed. Explicit results of inverse methods using volumes as input data are not presented in this paper for concision purpose. The effects on accuracy of various experimental parameters has been investigated and quantified: the volume measurement has proved to present a same order or even better signal-to-noise ratio compared to optical measurements.
Collapse
Affiliation(s)
- SEYED ALI ELAHI
- TIMC-IMAG Laboratory, UMR CNRS 5525, Grenoble Alpes University, Pavillon Taillefer, Faculty of Medicine, Domaine de la Merci, La Tronche Cedex, 38706, France
| | - NATHANAEL CONNESSON
- TIMC-IMAG Laboratory, UMR CNRS 5525, Grenoble Alpes University, Pavillon Taillefer, Faculty of Medicine, Domaine de la Merci, La Tronche Cedex, 38706, France
| | - YOHAN PAYAN
- TIMC-IMAG Laboratory, UMR CNRS 5525, Grenoble Alpes University, Pavillon Taillefer, Faculty of Medicine, Domaine de la Merci, La Tronche Cedex, 38706, France
| |
Collapse
|
3
|
Gubenko MM, Morozov AV, Lyubicheva AN, Goryacheva IG, Dosaev MZ, Ju MS, Yeh CH, Su FC. Video-tactile pneumatic sensor for soft tissue elastic modulus estimation. Biomed Eng Online 2017; 16:94. [PMID: 28764711 PMCID: PMC5539932 DOI: 10.1186/s12938-017-0390-3] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 07/28/2017] [Indexed: 12/30/2022] Open
Abstract
Background A new sensor for estimating elasticity of soft tissues such as a liver was developed for minimally invasive surgery application. Methods By measuring deformation and adjusting internal pressure of the pneumatic sensor head, the sensor can be used to do palpation (indentation) of tissues with wide range of stiffness. A video camera installed within the sensor shell is used to register the radius of the contact area. Based on finite element model simulations and the measured data, elastic modulus of the indented soft tissue can be calculated. Results and conclusions Three phantom materials, namely plastic, silicone and gelatin, with varied stiffness were tested. The experimental results demonstrated that the new sensor can obtain highly reliable data with error less than 5%. The new sensor might be served as an instrument in laparoscopic surgery for diagnosis of pathological tissues or internal organs.
Collapse
Affiliation(s)
- M M Gubenko
- A. Ishlinsky Institute for Problems in Mechanics RAS, Moscow, Russia
| | - A V Morozov
- A. Ishlinsky Institute for Problems in Mechanics RAS, Moscow, Russia
| | - A N Lyubicheva
- A. Ishlinsky Institute for Problems in Mechanics RAS, Moscow, Russia
| | - I G Goryacheva
- A. Ishlinsky Institute for Problems in Mechanics RAS, Moscow, Russia
| | - M Z Dosaev
- Institute of Mechanics, Lomonosov Moscow State University, Moscow, Russia
| | - M-Sh Ju
- Department of Mechanical Engineering, National Cheng Kung University, Tainan City, Taiwan
| | - Ch-H Yeh
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan
| | - F-Ch Su
- Medical Device Innovation Center, National Cheng Kung University, Tainan, Taiwan. .,Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan.
| |
Collapse
|
4
|
Weickenmeier J, Jabareen M, Mazza E. Suction based mechanical characterization of superficial facial soft tissues. J Biomech 2015; 48:4279-86. [PMID: 26584965 DOI: 10.1016/j.jbiomech.2015.10.039] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Revised: 10/15/2015] [Accepted: 10/25/2015] [Indexed: 10/22/2022]
Abstract
The present study is aimed at a combined experimental and numerical investigation of the mechanical response of superficial facial tissues. Suction based experiments provide the location, time, and history dependent behavior of skin and SMAS (superficial musculoaponeurotic system) by means of Cutometer and Aspiration measurements. The suction method is particularly suitable for in vivo, multi-axial testing of soft biological tissue including a high repeatability in subsequent tests. The campaign comprises three measurement sites in the face, i.e. jaw, parotid, and forehead, using two different loading profiles (instantaneous loading and a linearly increasing and decreasing loading curve), multiple loading magnitudes, and cyclic loading cases to quantify history dependent behavior. In an inverse finite element analysis based on anatomically detailed models an optimized set of material parameters for the implementation of an elastic-viscoplastic material model was determined, yielding an initial shear modulus of 2.32kPa for skin and 0.05kPa for SMAS, respectively. Apex displacements at maximum instantaneous and linear loading showed significant location specificity with variations of up to 18% with respect to the facial average response while observing variations in repeated measurements in the same location of less than 12%. In summary, the proposed parameter sets for skin and SMAS are shown to provide remarkable agreement between the experimentally observed and numerically predicted tissue response under all loading conditions considered in the present study, including cyclic tests.
Collapse
Affiliation(s)
- J Weickenmeier
- Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland; Department of Mechanical Engineering, Stanford University, Stanford, USA
| | - M Jabareen
- Faculty of Civil and Environmental Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
| | - E Mazza
- Department of Mechanical and Process Engineering, ETH Zurich, Zurich, Switzerland; Swiss Federal Laboratories for Materials Science and Technology, EMPA Duebendorf, Duebendorf, Switzerland
| |
Collapse
|
5
|
Influence of Geometry and Mechanical Properties on the Accuracy of Patient-Specific Simulation of Women Pelvic Floor. Ann Biomed Eng 2015. [PMID: 26215307 DOI: 10.1007/s10439-015-1401-9] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The woman pelvic system involves multiple organs, muscles, ligaments, and fasciae where different pathologies may occur. Here we are most interested in abnormal mobility, often caused by complex and not fully understood mechanisms. Computer simulation and modeling using the finite element (FE) method are the tools helping to better understand the pathological mobility, but of course patient-specific models are required to make contribution to patient care. These models require a good representation of the pelvic system geometry, information on the material properties, boundary conditions and loading. In this contribution we focus on the relative influence of the inaccuracies in geometry description and of uncertainty of patient-specific material properties of soft connective tissues. We conducted a comparative study using several constitutive behavior laws and variations in geometry description resulting from the imprecision of clinical imaging and image analysis. We find that geometry seems to have the dominant effect on the pelvic organ mobility simulation results. Provided that proper finite deformation non-linear FE solution procedures are used, the influence of the functional form of the constitutive law might be for practical purposes negligible. These last findings confirm similar results from the fields of modeling neurosurgery and abdominal aortic aneurysms.
Collapse
|
6
|
Myers KM, Feltovich H, Mazza E, Vink J, Bajka M, Wapner RJ, Hall TJ, House M. The mechanical role of the cervix in pregnancy. J Biomech 2015; 48:1511-23. [PMID: 25841293 PMCID: PMC4459908 DOI: 10.1016/j.jbiomech.2015.02.065] [Citation(s) in RCA: 128] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2015] [Accepted: 02/28/2015] [Indexed: 01/10/2023]
Abstract
Appropriate mechanical function of the uterine cervix is critical for maintaining a pregnancy to term so that the fetus can develop fully. At the end of pregnancy, however, the cervix must allow delivery, which requires it to markedly soften, shorten and dilate. There are multiple pathways to spontaneous preterm birth, the leading global cause of death in children less than 5 years old, but all culminate in premature cervical change, because that is the last step in the final common pathway to delivery. The mechanisms underlying premature cervical change in pregnancy are poorly understood, and therefore current clinical protocols to assess preterm birth risk are limited to surrogate markers of mechanical function, such as sonographically measured cervical length. This is what motivates us to study the cervix, for which we propose investigating clinical cervical function in parallel with a quantitative engineering evaluation of its structural function. We aspire to develop a common translational language, as well as generate a rigorous integrated clinical-engineering framework for assessing cervical mechanical function at the cellular to organ level. In this review, we embark on that challenge by describing the current landscape of clinical, biochemical, and engineering concepts associated with the mechanical function of the cervix during pregnancy. Our goal is to use this common platform to inspire novel approaches to delineate normal and abnormal cervical function in pregnancy.
Collapse
Affiliation(s)
- Kristin M Myers
- Department of Mechanical Engineering, Columbia University, New York, NY, USA.
| | - Helen Feltovich
- Department of Obstetrics and Gynecology, Intermountain Healthcare, Provo, UT, USA; Department of Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Edoardo Mazza
- Department of Mechanical and Process Engineering, ETH Zurich, & EMPA Dübendorf, Switzerland
| | - Joy Vink
- Department of Obstetrics and Gynecology, Columbia University Medical Center, New York, NY USA
| | - Michael Bajka
- Department of Obstetrics and Gynecology, University Hospital of Zurich, Switzerland
| | - Ronald J Wapner
- Department of Obstetrics and Gynecology, Columbia University Medical Center, New York, NY USA
| | - Timothy J Hall
- Department of Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Michael House
- Department of Obstetrics and Gynecology, Tufts Medical Center, Boston, MA, USA
| |
Collapse
|