1
|
Yacouba A, Bellali S, Haddad G, Mavros N, Fontanini A, Dubourg G, Lagier JC, Raoult D, Bou Khalil J. Use of scanning electron microscopy and energy dispersive X-ray for urine analysis: A preliminary investigation. Microsc Res Tech 2023; 86:1249-1257. [PMID: 36773029 DOI: 10.1002/jemt.24301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 01/21/2023] [Accepted: 01/30/2023] [Indexed: 02/12/2023]
Abstract
Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) are powerful tools to study the ultrastructure of numerous specimens and to determine their elemental composition, respectively. However, results have not yet been reported on their application to urine samples in routine clinical laboratory practice. Herein we investigate urine sediment by using SEM and EDX to detect and identify different urine components. A total of 206 urine samples from patients with and without urinary tract infections were analyzed using SEM and EDX. Microorganisms, crystals, epithelial cells, leukocytes, and erythrocytes were targeted in urine sediment samples. The identification of urine components was based on their morphology, size, contrast, and elemental composition. SEM-analysis allowed us to identify and classify microorganisms in urine sediments into the categories of gram-negative bacilli, cluster cocci, chain cocci, gram-negative bacilli, gram-positive bacilli, and yeasts. In addition, various types of epithelial cells such as renal, transitional, and squamous epithelial cells were found. Furthermore, leukocytes and erythrocytes were well identified, with the detection of various morphological forms of erythrocytes, such as dysmorphic and isomorphic erythrocytes. Using SEM-EDX analysis, calcium oxalate was the most frequently-identified crystal (92.0%), with prominent peaks of C, O, and Ca elements, followed by struvite (6%), with peaks of Mg, P, O, and N. These preliminary data suggest that the two complementary SEM-EDX analyses can be used to detect and identify microorganisms and crystals in urine samples. Further studies are still needed to apply SEM-EDX to urine sediment analysis. SEM-EDX analyses provided comparative results with the routine results, with accurate identification, high resolution and deep focus compared to the routine urinalysis SEM-analysis allowed us to identify and classify microorganisms in urine sediments into the categories of gram-negative bacilli, cluster cocci, chain cocci, gram-negative bacilli, gram-positive bacilli and yeasts. SEM-EDX analysis enabled the accurate identification of crystals based on both morphology and elemental composition.
Collapse
Affiliation(s)
- Abdourahamane Yacouba
- IRD, AP-HM, MEPHI, Aix Marseille University, Marseille, France
- IHU-Méditerranée Infection, Marseille, France
- Université Abdou Moumouni, Niamey, Niger
| | | | - Gabriel Haddad
- IRD, AP-HM, MEPHI, Aix Marseille University, Marseille, France
- IHU-Méditerranée Infection, Marseille, France
| | | | | | - Grégory Dubourg
- IRD, AP-HM, MEPHI, Aix Marseille University, Marseille, France
| | | | | | | |
Collapse
|
2
|
Mushtaq M, Qureshi OA, Dua A, Khan S, Mehraj M. Metallosis and Nonunion: A Case Series and Literature Review. Cureus 2023; 15:e35385. [PMID: 36994246 PMCID: PMC10042499 DOI: 10.7759/cureus.35385] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/23/2023] [Indexed: 03/31/2023] Open
Abstract
Metallosis, defined as the presence of free metal particles in the tissue, including bone and soft tissue, is a rare phenomenon seen in orthopedic practice. It is more commonly seen in arthroplasty surgeries, but its occurrence in the presence of other metal implants is also well recognized. Multiple hypotheses are suggested to explain the genesis of metallosis, but it is traditionally believed that abnormal contact between the metal surfaces leads to abrasive wear causing the release of metal particles into the surrounding tissue eliciting foreign body reactions from the body's immune system. The consequences can be local effects, which can be asymptomatic soft tissue lesions, or lead to significant osteolysis, tissue necrosis, joint effusion, and large soft tissue masses, causing secondary pathological effects. The systemic distribution of these metal particles can also contribute to the clinical picture. The literature contains multiple case reports of metallosis following arthroplasty surgeries, but there is limited information on metallosis resulting from osteosynthesis of fractures. In this review, we are presenting our experience with a few patients who developed nonunion following the index surgeries and on revision were found to have metallosis as well. It is difficult to postulate whether metallosis was contributory to the nonunion or the other way around or whether the occurrence of nonunion in face of metallosis was a pure coincidence. Additionally, one of our patients had a positive intraoperative culture, further complicating the picture. In addition to the case series, we present a succinct review of the literature on metallosis found in previous studies.
Collapse
Affiliation(s)
- Muzaffar Mushtaq
- Orthopedics, Hamdard Institute of Medical Sciences and Research, Delhi, IND
| | - Owais A Qureshi
- Orthopedics, Hamdard Institute of Medical Sciences and Research, Delhi, IND
| | - Anmol Dua
- Orthopedics, Hamdard Institute of Medical Sciences and Research, Delhi, IND
| | - Sabina Khan
- Pathology, Hamdard Institute of Medical Sciences and Research, Delhi, IND
| | - Meesa Mehraj
- Pathology, Hamdard Institute of Medical Sciences and Research, Delhi, IND
| |
Collapse
|
3
|
Wouthuyzen-Bakker M, Boerboom A. Black pus from a worn-out elbow arthroplasty. J Bone Jt Infect 2022; 7:33-34. [PMID: 35155082 PMCID: PMC8830416 DOI: 10.5194/jbji-7-33-2022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Accepted: 01/24/2022] [Indexed: 11/16/2022] Open
Affiliation(s)
- Marjan Wouthuyzen-Bakker
- Department of Medical Microbiology and Infection Prevention, University of
Groningen, University Medical Center Groningen, Groningen, the Netherlands
| | - Alexander L. Boerboom
- Department of Orthopaedic Surgery, University of Groningen, University
Medical Center Groningen, Groningen, the Netherlands
| |
Collapse
|
4
|
Imada AO, Painter BM, Clinger B, Decker MM. A Rare Case of Metallosis Co-occurring With Chronic Prosthetic Joint Infection in Total Hip Arthroplasty. Cureus 2022; 14:e21515. [PMID: 35223291 PMCID: PMC8862693 DOI: 10.7759/cureus.21515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/23/2022] [Indexed: 11/17/2022] Open
Abstract
Prosthetic joint infection (PJI) and metallosis are known complications of total hip arthroplasty (THA) and are causes for revision surgeries. Articulating metal surfaces in total hip arthroplasty with corrosion at modular junctions can lead to the release of metal ions that can cause an immune-mediated biological reaction. There are few cases in the literature of both coinciding together. We describe a case of chronic Cutibacertium acnes PJI and metallosis co-occurring in a 64-year-old female after THA with a dual mobility construct. After undergoing uncomplicated left THA through a modified Hardinge approach, the patient dislocated anteriorly after four weeks and required revision of her acetabular component to a less anteverted position. Nine months later, she presented with hip pain and was found to have medial wall fragmentation and cystic changes around the greater trochanter on radiographs, elevated serum cobalt and chromium levels, and a benign noninfected hip aspiration. During her revision procedure, intraoperative histopathology showed over 20 neutrophils per high power field in multiple samples and fluid aspirates demonstrating Gram-positive rods. She was also found to have pseudotumor formation with the erosion of the anterior and posterior capsules with black debris on the femoral stem trunnion and the backside of the modular dual mobility liner. An antibiotic spacer was placed and her cultures grew into C. acnes. She completed six weeks of intravenous ceftriaxone and, during her "drug holiday," she dislocated her spacer and was found to have a lateral femoral diaphyseal stress fracture at the distal end of her spacer. She underwent stage II of her revision, and while the plan was to continue her antibiotics, she had an adverse reaction and was transitioned to oral antibiotics for six months. Due to delayed healing, she underwent additional irrigation and debridement with head and liner exchange. Her wound then healed, and at her one-year final follow-up, she was able to ambulate without pain, and her serum inflammatory and metal ion levels were within normal limits. Concurrent PJI and metallosis from articulating metal interfaces can occur, and a high index of suspicion is necessary to properly manage both conditions.
Collapse
|
5
|
Artiaco S, Fusini F, Zoccola K, Massè A, Colzani G. Metallosis in Sequelae of Prosthetic Revision for Ceramic Components Fracture: A Case Report with Clinical Presentation Mimicking Periprosthetic Hip Infection. JOINTS 2021; 7:215-217. [PMID: 34235388 PMCID: PMC8253606 DOI: 10.1055/s-0041-1730981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/01/2018] [Accepted: 04/18/2021] [Indexed: 10/24/2022]
Abstract
Ceramic on ceramic total hip arthroplasties have been developed and widely used during last decades because of their long-term survival and biomechanical properties. One of the most dangerous complication of these implants is the fracture of the ceramic components. The management of this condition should be carefully planned and the choice of the new implant is crucial. We describe a rare case of severe hip synovitis due to massive metallosis in sequelae of mismanaged prosthetic revision for fracture of the ceramic acetabular liner with an unusual clinical presentation that simulate a periprosthetic infection.
Collapse
Affiliation(s)
- Stefano Artiaco
- Department of Orthopaedics and Traumatology, Orthopaedic and Trauma Center, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Turin, Italy
| | - Federico Fusini
- Department of Orthopaedics and Traumatology, Orthopaedic and Trauma Center, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Turin, Italy
| | - Kristijan Zoccola
- Department of Orthopaedics and Traumatology, Orthopaedic and Trauma Center, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Turin, Italy
| | - Alessandro Massè
- Department of Orthopaedics and Traumatology, Orthopaedic and Trauma Center, Azienda Ospedaliero Universitaria Città della Salute e della Scienza, Turin, Italy
| | - Giulia Colzani
- Department of Orthopaedics and Traumatology, Policlinico di Modena, Azienda Ospedaliera Universitaria, Modena, Italy
| |
Collapse
|
6
|
Sahan I, Anagnostakos K. Metallosis after knee replacement: a review. Arch Orthop Trauma Surg 2020; 140:1791-1808. [PMID: 32715399 DOI: 10.1007/s00402-020-03560-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Accepted: 07/20/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Although metallosis is a well-known complication after total hip arthroplasty, little is known about this phenomenon after total (TKA) or unicompartmental knee arthroplasty (UKA). The aim of the present work was to review the current knowledge about the reasons and the diagnostic as well as therapeutic management of metallosis after knee arthroplasty. MATERIALS AND METHODS A literature search was performed through PubMed until April 2019. Search terms were "metallosis" in combination with "knee", "knee prosthesis", "knee arthroplasty" and "knee replacement", respectively. All publications were analyzed regarding publication year, level of evidence, number of knees/patients treated, type of prosthesis, metallosis cause, time period between primary implantation and metallosis emergence, laboratory examination, treatment, complications and follow up. RESULTS A total of 38 studies reporting on a total of 97 knees were identified. 29 studies reported on metallosis after TKA, 8 after UKA, and one study after both procedures. The time period between the primary implantation and metallosis emergence ranged between 6 weeks and 26 years. The most common reason was the failure of a metal-backed patellar component in 40%, followed by implant/structural- and PE failure (wear/dislocation) in 27% and 18% of the cases, respectively. Complete blood cell count, serum chemistry, erythrocyte sedimentation rate or C-reactive protein serum values were not indicative to diagnose metallosis. The diagnosis was confirmed by histopathological analyses and macroscopic evaluation during surgery. Depending on the particular cause various surgical procedures have been performed. Complete prosthesis exchange was the most common one showing no complications in 89.4% of the cases. CONCLUSIONS Metallosis after knee arthroplasty is a rare and perhaps underestimated or under published complication. A systematic diagnostic approach is necessary for the timely and correct diagnosis. A thorough debridement as well as a (sub)total synovectomy should be always performed. In cases with a damaged component, a partial/complete prosthesis exchange leads to the best results. Should a malalignment be the cause of the metallosis, then it should be corrected within the revision surgery.
Collapse
Affiliation(s)
- Ismail Sahan
- Zentrum für Orthopädie und Unfallchirurgie, Klinikum Saarbrücken, Winterberg 1, 66119, Saarbrücken, Germany.
| | - Konstantinos Anagnostakos
- Zentrum für Orthopädie und Unfallchirurgie, Klinikum Saarbrücken, Winterberg 1, 66119, Saarbrücken, Germany
| |
Collapse
|
7
|
The W.A.I.O.T. Definition of High-Grade and Low-Grade Peri-Prosthetic Joint Infection. J Clin Med 2019; 8:jcm8050650. [PMID: 31083439 PMCID: PMC6571975 DOI: 10.3390/jcm8050650] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 05/06/2019] [Accepted: 05/09/2019] [Indexed: 12/27/2022] Open
Abstract
The definition of peri-prosthetic joint infection (PJI) has a strong impact on the diagnostic pathway and on treatment decisions. In the last decade, at least five different definitions of peri-prosthetic joint infection (PJI) have been proposed, each one with intrinsic limitations. In order to move a step forward, the World Association against Infection in Orthopedics and Trauma (W.A.I.O.T.) has studied a possible alternative solution, based on three parameters: 1. the relative ability of each diagnostic test or procedure to Rule OUT and/or to Rule IN a PJI; 2. the clinical presentation; 3. the distinction between pre/intra-operative findings and post-operative confirmation. According to the WAIOT definition, any positive Rule IN test (a test with a specificity > 90%) scores +1, while a negative Rule OUT test (a test with a sensitivity > 90%) scores −1. When a minimum of two Rule IN and two Rule OUT tests are performed in a given patient, the balance between positive and negative tests, interpreted in the light of the clinical presentation and of the post-operative findings, allows to identify five different conditions: High-Grade PJI (score ≥ 1), Low-Grade PJI (≥0), Biofilm-related implant malfunction, Contamination and No infection (all scoring < 0). The proposed definition leaves the physician free to choose among different tests with similar sensitivity or specificity, on the basis of medical, logistical and economic considerations, while novel tests or diagnostic procedures can be implemented in the definition at any time, provided that they meet the required sensitivity and/or specificity thresholds. Key procedures to confirm or to exclude the diagnosis of PJI remain post-operative histological and microbiological analysis; in this regard, given the biofilm-related nature of PJI, microbiological investigations should be conducted with proper sampling, closed transport systems, antibiofilm processing of tissue samples and explanted biomaterials, and prolonged cultures. The proposed WAIOT definition is the result of an international, multidisciplinary effort. Next step will be a large scale, multicenter clinical validation trial.
Collapse
|
8
|
Abdel Karim M, Andrawis J, Bengoa F, Bracho C, Compagnoni R, Cross M, Danoff J, Della Valle CJ, Foguet P, Fraguas T, Gehrke T, Goswami K, Guerra E, Ha YC, Klaber I, Komnos G, Lachiewicz P, Lausmann C, Levine B, Leyton-Mange A, McArthur BA, Mihalič R, Neyt J, Nuñez J, Nunziato C, Parvizi J, Perka C, Reisener MJ, Rocha CH, Schweitzer D, Shivji F, Shohat N, Sierra RJ, Suleiman L, Tan TL, Vasquez J, Ward D, Wolf M, Zahar A. Hip and Knee Section, Diagnosis, Algorithm: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty 2019; 34:S339-S350. [PMID: 30348566 DOI: 10.1016/j.arth.2018.09.018] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
9
|
Scimeca M, Bischetti S, Lamsira HK, Bonfiglio R, Bonanno E. Energy Dispersive X-ray (EDX) microanalysis: A powerful tool in biomedical research and diagnosis. Eur J Histochem 2018; 62:2841. [PMID: 29569878 PMCID: PMC5907194 DOI: 10.4081/ejh.2018.2841] [Citation(s) in RCA: 106] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2017] [Revised: 01/15/2018] [Accepted: 01/17/2018] [Indexed: 02/06/2023] Open
Abstract
The Energy Dispersive X-ray (EDX) microanalysis is a technique of elemental analysis associated to electron microscopy based on the generation of characteristic Xrays that reveals the presence of elements present in the specimens. The EDX microanalysis is used in different biomedical fields by many researchers and clinicians. Nevertheless, most of the scientific community is not fully aware of its possible applications. The spectrum of EDX microanalysis contains both semi-qualitative and semi-quantitative information. EDX technique is made useful in the study of drugs, such as in the study of drugs delivery in which the EDX is an important tool to detect nanoparticles (generally, used to improve the therapeutic performance of some chemotherapeutic agents). EDX is also used in the study of environmental pollution and in the characterization of mineral bioaccumulated in the tissues. In conclusion, the EDX can be considered as a useful tool in all works that require element determination, endogenous or exogenous, in the tissue, cell or any other sample.
Collapse
Affiliation(s)
- Manuel Scimeca
- University of Rome "Tor Vergata", Department of Biomedicine and Prevention.
| | | | | | | | | |
Collapse
|
10
|
Metallosis in shoulder arthroplasty: an integrative review of literature. Musculoskelet Surg 2016; 100:3-11. [PMID: 27900702 DOI: 10.1007/s12306-016-0408-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2016] [Accepted: 05/19/2016] [Indexed: 02/08/2023]
Abstract
Shoulder arthroplasty has gained popularity as an efficient means of achieving pain relief and improved function in a variety of complex shoulder disorders. Despite promising reports, given the increasing number of shoulder arthroplasty procedures, various causes that may contribute to failure of a well-functioning arthroplasty are being increasingly recognized. One such disastrous condition is metallosis, a subject which has not been much talked off with reference to shoulder arthroplasty. This article besides reviewing the existing literature intends to discuss the possible causes that contribute to metallosis and devise a protocol for its timely diagnosis and management.
Collapse
|