Hammelef E, Rapuano CJ, Benedetto DA, Syed ZA, Myers JS, Razeghinejad MR, Silver FH, Pulido JS. New forays into measurement of ocular biomechanics. Curr Opin Ophthalmol 2024; 35:225-231. [PMID: 38484223 DOI: 10.1097/icu.0000000000001032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/24/2024]
Abstract
PURPOSE OF REVIEW The field of corneal biomechanics has rapidly progressed in recent years, reflecting technological advances and an increased understanding of the clinical significance of measuring these properties. This review will evaluate in-vivo biomechanical properties obtained by current technologies and compare them regarding their relevance to established biomechanical properties obtained by gold-standard ex-vivo techniques normally conducted on elastic materials. RECENT FINDINGS Several new technologies have appeared in recent years, including vibrational optical coherence tomography (VOCT) and the corneal indentation device (CID). These techniques provide promising new opportunities for minimally invasive and accurate measurements of corneal viscoelastic properties. SUMMARY Alterations in corneal biomechanics are known to occur in several corneal degenerative diseases and after refractive surgical procedures. The measurement of corneal biomechanical properties has the capability to diagnose early disease and monitor corneal disease progression. Several new technologies have emerged in recent years, allowing for more accurate and less invasive measurements of corneal biomechanical properties, most notably the elastic modulus.
Collapse
Affiliation(s)
- Emma Hammelef
- Sidney Kimmel Medical College at Thomas Jefferson University at Thomas Jefferson University
| | - Christopher J Rapuano
- Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Dominick A Benedetto
- Center for Advanced Eye Care, Vero Beach, Florida
- OptoVibronex, LLC, Bethlehem, Pennsylvania
| | - Zeba A Syed
- Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Jonathan S Myers
- Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - M Reza Razeghinejad
- Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
| | - Fred H Silver
- OptoVibronex, LLC, Bethlehem, Pennsylvania
- Department of Pathology and Laboratory Medicine, Robert Wood Johnson Medical School, Piscataway, New Jersey, USA
| | - Jose S Pulido
- Wills Eye Hospital, Sidney Kimmel Medical College at Thomas Jefferson University, Philadelphia, Pennsylvania
| |
Collapse
|
2
|
Lombardo G, Alunni-Fegatelli D, Serrao S, Mencucci R, Roszkowska AM, Bernava GM, Vestri A, Aleo D, Lombardo M. Accuracy of an Air-Puff Dynamic Tonometry Biomarker to Discriminate the Corneal Biomechanical Response in Patients With Keratoconus. Cornea 2024; 43:315-322. [PMID: 37964435 DOI: 10.1097/ico.0000000000003377] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 07/30/2023] [Indexed: 11/16/2023]
Abstract
PURPOSE The aim of this study was to assess accuracy of the mean corneal stiffness ( kc , N/m) parameter to discriminate between patients with keratoconus and age-matched healthy subjects. METHODS Dynamic Scheimpflug imaging tonometry was performed with Corvis ST (Oculus Optikgeräte GmbH, Germany) in patients with keratoconus (n = 24; study group) and age-matched healthy subjects (n = 32; control). An image processing algorithm was developed to analyze the video sequence of the Corvis ST air-puff event and to determine the geometric and temporal parameters that correlated with the corneal tissue biomechanical properties. A modified 3-element viscoelastic model was used to derive the kc parameter, which represented the corneal tissue resistance to deformation under load. Receiver operating characteristic curves were used to assess the overall diagnostic performance for determining the area under the curve, sensitivity, and specificity of the kc in assessing the corneal tissue deformation to the Corvis ST air-puff event in keratoconus and control eyes. The Corvis Biomechanical Index ( CBI ) was analyzed for external validation. RESULTS The kc parameter was significantly different between keratoconus and controls ( P < 0.001), ranging from 24.9 ±3.0 to 34.2 ±3.5 N/m, respectively. It was highly correlated with CBI (r = -0.69; P < 0.001); however, the kc parameter had greater specificity (94%) than CBI (75%), whereas the 2 biomarkers had similar area under the curve (0.98 vs. 0.94) and sensitivity (96% vs. 92%) in predicting the occurrence of keratoconus. CONCLUSIONS The kc parameter extracted by video processing analysis of dynamic Scheimpflug tonometry data was highly accurate in discriminating patients with clinically manifest keratoconus compared with controls.
Collapse
Affiliation(s)
- Giuseppe Lombardo
- CNR-IPCF, Istituto per i Processi Chimico-Fisici, Messina, Italy
- Vision Engineering Italy srl, Rome, Italy
| | - Danilo Alunni-Fegatelli
- Department of Public Health and infectious Diseases, University of Rome "La Sapienza", Rome, Italy
| | | | - Rita Mencucci
- SOD Oculistica, AOU Careggi, Università di Firenze, Firenze, Italy
| | | | | | - Annarita Vestri
- Department of Public Health and infectious Diseases, University of Rome "La Sapienza", Rome, Italy
| | | | - Marco Lombardo
- Vision Engineering Italy srl, Rome, Italy
- Studio Italiano di Oftalmologia, Rome, Italy
| |
Collapse
|
3
|
Shih PJ, Shih HJ, Wang IJ, Chang SW. The extraction and application of antisymmetric characteristics of the cornea during air-puff perturbations. Comput Biol Med 2024; 168:107804. [PMID: 38070205 DOI: 10.1016/j.compbiomed.2023.107804] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 11/04/2023] [Accepted: 11/29/2023] [Indexed: 01/10/2024]
Abstract
BACKGROUND A non-contact tonometer is used to measure intraocular pressure, and studies have primarily relied on apex displacements to assess corneal properties. However, previous studies have overlooked the asymmetric characteristics of lateral corneal perturbations, leading to a gap in understanding of the lateral mechanical properties and its application. METHOD To investigate these lateral perturbations, we designed an experiment to sequentially record the corneal profiles when two consecutive air-puffs were applied at the center of the same cornea within a short period. Moreover, we used modal decomposition to decompose anterior surface profiles into symmetric and antisymmetric modes to comprehensively analyze the asymmetric characteristics. To extract mechanical properties, we utilized high-pass frequency analysis (>250 Hz) to filter out noise and errors. RESULTS Symmetric modes between the two consecutive air-puffs exhibited major similarities during vibration; however, antisymmetric modes exhibited minor differences in lateral perturbations of asymmetric vibration. The antisymmetric modes might be related to air-puff misalignment and mechanical properties. Through applying frequency analysis, the mechanical properties could be proven at high frequencies and misalignment shown at low frequencies. Furthermore, we compared the corneal vibration profiles of 259 healthy participants and 50 patients with keratoconus. Their properties showed that the antisymmetric modes of the keratoconus group exhibited a completely opposite direction of deformation compared to that in the healthy group. CONCLUSIONS Our proposed algorithm not only extracts antisymmetric characteristics but also offers valuable insights into decompose misalignment and mechanical properties of healthy and keratoconus corneas, presenting a new perspective for corneal biomechanics.
Collapse
Affiliation(s)
- Po-Jen Shih
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan.
| | - Hua-Ju Shih
- Department of Otolaryngology, National Taiwan University Hospital, Taipei, Taiwan
| | - I-Jong Wang
- Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan
| | - Shu-Wen Chang
- Department of Ophthalmology, Far Eastern Memorial Hospital, New Taipei City, Taiwan.
| |
Collapse
|
4
|
Kenia VP, Kenia RV, Bendre P, Pirdankar OH. Corneal stress-strain index in myopic Indian population. Oman J Ophthalmol 2024; 17:47-52. [PMID: 38524314 PMCID: PMC10957058 DOI: 10.4103/ojo.ojo_122_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 11/18/2023] [Indexed: 03/26/2024] Open
Abstract
AIM The purpose is to study the corneal stress-strain index (SSI) in myopic refractive error among Indian subjects. METHODS A retrospective study where young myopic subjects aged between 11 and 35 years who had undergone corneal biomechanics assessment using Corvis ST between January 2017 and December 2021 were enrolled. Subjects with central corneal thickness (CCT) <500 μ, intraocular pressure (IOP) >21 mmHg, history of any systemic and ocular disease or any previous ocular surgery, high astigmatism, corneal disease such as keratoconus were excluded. Subjects with missing data or having poor quality scan were excluded. Corneal biomechanical properties and corneal SSI were assessed using Corvis ST. For statistical purposes, eyes were divided into four different groups and were analyzed using one-way ANOVA. RESULTS Nine hundred and sixty-six myopic eyes with mean ± standard deviation age, IOP, and CCT of 26.89 ± 4.92 years, 16.94 ± 2.00 mmHg, and 540.18 ± 25.23 microns, respectively, were included. There were 311, 388, 172, and 95 eyes that were low, moderate, severe, and extreme myopic. Deformation amplitude ratio at 1 mm and 2 mm were similar across different myopic groups. A significant increase in max inverse radius, ambrosia relational thickness, biomechanically corrected IOP, integrated radius was noted with an increase in myopic refractive error. Corvis biomechanical index, corneal SSI was found to be decreased significantly with an increase in myopic refractive error. We noted a significant positive association between myopic refractive error and SSI (P < 0.001). CONCLUSION Corneal SSI was found to be reduced in extreme myopic eyes.
Collapse
Affiliation(s)
- Vaishal P. Kenia
- Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India
| | - Raj V. Kenia
- Department of Ophthalmology, Kenia Foundation, Mumbai, Maharashtra, India
| | - Pradnya Bendre
- Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India
| | | |
Collapse
|
5
|
Chen X, Tan Z, Huo Y, Song J, Xu Q, Yang C, Jhanji V, Li J, Hou J, Zou H, Ali Khan G, Alzogool M, Wang R, Wang Y. Localized Corneal Biomechanical Alteration Detected In Early Keratoconus Based on Corneal Deformation Using Artificial Intelligence. Asia Pac J Ophthalmol (Phila) 2023; 12:574-581. [PMID: 37973045 DOI: 10.1097/apo.0000000000000644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 09/27/2023] [Indexed: 11/19/2023] Open
Abstract
PURPOSE This study aimed to develop a novel method to diagnose early keratoconus by detecting localized corneal biomechanical changes based on dynamic deformation videos using machine learning. DESIGN Diagnostic research study. METHODS We included 917 corneal videos from the Tianjin Eye Hospital (Tianjin, China) and Shanxi Eye Hospital (Xi'an, China) from February 6, 2015, to August 25, 2022. Scheimpflug technology was used to obtain dynamic deformation videos under forced puffs of air. Fourteen new pixel-level biomechanical parameters were calculated based on a spline curve equation fitting by 115,200-pixel points from the corneal contour extracted from videos to characterize localized biomechanics. An ensemble learning model was developed, external validation was performed, and the diagnostic performance was compared with that of existing clinical diagnostic indices. The performance of the developed machine learning model was evaluated using precision, recall, F1 score, and the area under the receiver operating characteristic curve. RESULTS The ensemble learning model successfully diagnosed early keratoconus (area under the curve = 0.9997) with 95.73% precision, 95.61% recall, and 95.50% F1 score in the sample set (n=802). External validation on an independent dataset (n=115) achieved 91.38% precision, 92.11% recall, and 91.18% F1 score. Diagnostic accuracy was significantly better than that of existing clinical diagnostic indices (from 86.28% to 93.36%, all P <0.01). CONCLUSIONS Localized corneal biomechanical changes detected using dynamic deformation videos combined with machine learning algorithms were useful for diagnosing early keratoconus. Focusing on localized biomechanical changes may guide ophthalmologists, aiding the timely diagnosis of early keratoconus and benefiting the patient's vision.
Collapse
Affiliation(s)
- Xuan Chen
- School of Medicine, Nankai University, Tianjin, China
| | - Zuoping Tan
- Wenzhou University of Technology, Wenzhou, Zhejiang, China
| | - Yan Huo
- School of Medicine, Nankai University, Tianjin, China
| | - Jiaxin Song
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Qiang Xu
- Wenzhou University of Technology, Wenzhou, Zhejiang, China
| | - Can Yang
- Wenzhou University of Technology, Wenzhou, Zhejiang, China
| | - Vishal Jhanji
- Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, PA
| | - Jing Li
- Shanxi Eye Hospital, Xi'an People's Hospital, Xi'an, China
| | - Jie Hou
- Jinan Mingshui Eye Hospital, Ji'nan, Shandong, China
| | - Haohan Zou
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Gauhar Ali Khan
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | | | - Riwei Wang
- Wenzhou University of Technology, Wenzhou, Zhejiang, China
| | - Yan Wang
- School of Medicine, Nankai University, Tianjin, China
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
- Nankai Eye Institute, Nankai University, Tianjin, China
| |
Collapse
|
6
|
Elhusseiny AM, Scarcelli G, Saeedi OJ. Corneal Biomechanical Measures for Glaucoma: A Clinical Approach. Bioengineering (Basel) 2023; 10:1108. [PMID: 37892838 PMCID: PMC10604716 DOI: 10.3390/bioengineering10101108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/11/2023] [Accepted: 09/14/2023] [Indexed: 10/29/2023] Open
Abstract
Over the last two decades, there has been growing interest in assessing corneal biomechanics in different diseases, such as keratoconus, glaucoma, and corneal disorders. Given the interaction and structural continuity between the cornea and sclera, evaluating corneal biomechanics may give us further insights into the pathogenesis, diagnosis, progression, and management of glaucoma. Therefore, some authorities have recommended baseline evaluations of corneal biomechanics in all glaucoma and glaucoma suspects patients. Currently, two devices (Ocular Response Analyzer and Corneal Visualization Schiempflug Technology) are commercially available for evaluating corneal biomechanics; however, each device reports different parameters, and there is a weak to moderate agreement between the reported parameters. Studies are further limited by the inclusion of glaucoma subjects taking topical prostaglandin analogues, which may alter corneal biomechanics and contribute to contradicting results, lack of proper stratification of patients, and misinterpretation of the results based on factors that are confounded by intraocular pressure changes. This review aims to summarize the recent evidence on corneal biomechanics in glaucoma patients and insights for future studies to address the current limitations of the literature studying corneal biomechanics.
Collapse
Affiliation(s)
- Abdelrahman M. Elhusseiny
- Department of Ophthalmology, Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR 72205, USA;
- Department of Ophthalmology, Boston Children’s Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA;
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| | - Osamah J. Saeedi
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742, USA;
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, Baltimore, MD 21201, USA
| |
Collapse
|
7
|
Silver FH, Deshmukh T, Benedetto D, Gonzalez-Mercedes M. Dynamic Ocular Response to Mechanical Loading: The Role of Viscoelasticity in Energy Dissipation by the Cornea. Biomimetics (Basel) 2023; 8:63. [PMID: 36810394 PMCID: PMC9944807 DOI: 10.3390/biomimetics8010063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 01/26/2023] [Accepted: 01/31/2023] [Indexed: 02/05/2023] Open
Abstract
We have used vibrational optical coherence tomography (VOCT) to measure the resonant frequency, elastic modulus, and loss modulus of components of the anterior segment of pig eyes in vitro. Such basic biomechanical properties of the cornea have been shown to be abnormal not only in diseases of the anterior segment but also in posterior segment diseases as well. This information is needed to better understand corneal biomechanics in health and disease and to be able to diagnose the early stages of corneal pathologies. Results of dynamic viscoelastic studies on whole pig eyes and isolated corneas indicate that at low strain rates (30 Hz or less), the viscous loss modulus is as high as 0.6 times the elastic modulus for both whole eyes and corneas. This large viscous loss is similar to that of skin, which has been hypothesized to be dependent upon the physical association of proteoglycans with collagenous fibers. The energy dissipation properties of the cornea provide a mechanism to dissipate energy associated with blunt trauma, thereby preventing delamination and failure. The cornea possesses the ability to store impact energy and transmit excess energy to the posterior segment of the eye through its serial connection to the limbus and sclera. In this manner, the viscoelastic properties of the cornea, in concert with that of the posterior segment of the pig eye, function to prevent mechanical failure of the primary focusing element of the eye. Results of resonant frequency studies suggest that the 100-120 Hz and 150-160 Hz resonant frequency peaks reside in the anterior segment of the cornea since the removal of the anterior segment of the cornea decreases the peak heights at these resonant frequencies. These results suggest that there is more than one collagen fibril network found in the anterior portion of the cornea that provides structural integrity to prevent corneal delamination and that VOCT may be useful clinically to diagnose corneal diseases.
Collapse
Affiliation(s)
- Frederick H. Silver
- Department of Pathology and Laboratory Medicine, Robert Wood Johnson Medical School, Rutgers, The State University of New Jersey, Piscataway, NJ 08854, USA
- OptoVibronex, LLC, Ben Franklin Tech Partners, Bethlehem, PA 18015, USA
| | - Tanmay Deshmukh
- OptoVibronex, LLC, Ben Franklin Tech Partners, Bethlehem, PA 18015, USA
| | | | | |
Collapse
|
8
|
Catania F, Morenghi E, Rosetta P, Paolo V, Vinciguerra R. Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature. Curr Eye Res 2023; 48:161-171. [PMID: 35385343 DOI: 10.1080/02713683.2022.2059809] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
PURPOSE The aim of this meta-analysis of the literature is to provide a comprehensive analysis of the differences in Corvis ST dynamic corneal response (DCR) parameters between primary open-angle glaucoma (POAG) patients and healthy controls. METHODS A quantitative meta-analysis was conducted on articles published before September 10, 2021 identified by searching PubMed, EMBASE, and Web of Science. Prospective studies comparing DCR Corvis ST parameter in high tension POAG and healthy controls were included. The random-effects model was conducted. Assessment of heterogeneity was based on the calculation of I2. Funnel plots evaluation and meta-regression were performed in case of detection of high heterogeneity. RESULTS The selection process resulted in the inclusion of six articles. Pooled analysis revealed that POAG corneas respond to mechanical stimulus with a smaller concavity, showing lower deformation amplitude (DA) (CI95% -0.991 to -0.578; p < .001; I2 = 0%), higher highest concavity radius (HCR; confidence interval [CI]95% -0.01 to 0.34; p = .058; I2 = 6.7%), and lower peak distance (PD; CI95% -1.06 to -0.024; p = .040; I2 = 86.5%). They also show a slower loading phase, with lower highest concavity time (HCT; CI95% -0.39 to -0.02; p = .029; I2 = 3.3%) and lower applanation velocity-1 (CI95% -0.641 to -0.127; p = .003; I2 = 34.6%), and a faster restoration to the original form, shown by lower applanation time-2 (CI95% -1.123 to -0.544; p = .001; I2 = 44.8%) compared to healthy subjects. CONCLUSIONS High tension POAG patients are characterized by stiffer corneas compared to healthy controls. These differences are valid also after removing the effect of age, corneal thickness, and intraocular pressure (IOP).
Collapse
Affiliation(s)
- Fiammetta Catania
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.,Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy
| | - Emanuela Morenghi
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.,Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy
| | | | - Vinciguerra Paolo
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.,Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy
| | | |
Collapse
|
9
|
Lopes BT, Elsheikh A. In Vivo Corneal Stiffness Mapping by the Stress-Strain Index Maps and Brillouin Microscopy. Curr Eye Res 2023; 48:114-120. [PMID: 35634717 DOI: 10.1080/02713683.2022.2081979] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The study of corneal stiffness in vivo has numerous clinical applications such as the measurement of intraocular pressure, the preoperative screening for iatrogenic ectasia after laser vision correction surgery and the diagnosis and treatment of corneal ectatic diseases such as keratoconus. The localised aspect of the microstructure deterioration in keratoconus leading to local biomechanical softening, corneal bulging, irregular astigmatism and ultimately loss of vision boosted the need to map the corneal stiffness to identify the regional biomechanical failure. Currently, two methods to map the corneal stiffness in vivo are integrated into devices that are either already commercially available or about to be commercialised: the stress-strain index (SSI) maps and the Brillouin Microscopy (BM). The former method produces 2D map of stiffness across the corneal surface, developed through numerical simulations using the corneal shape, its microstructure content, and the deformation behaviour under air-puff excitation. It estimates the whole stress-strain behaviour, making it possible to obtain the material tangent modulus under different intraocular pressure levels. On the other hand, BM produces a 3D map of the corneal longitudinal modulus across the corneal surface and thickness. It uses a low-power near-infrared laser beam and through a spectral analysis of the returned signal, it assesses the mechanical compressibility of the tissue as measured by the longitudinal modulus. In this paper, these two techniques are reviewed, and their advantages and limitations discussed.
Collapse
Affiliation(s)
- Bernardo T Lopes
- School of Engineering, University of Liverpool, Liverpool, UK.,Department of Ophthalmology, Federal University of São Paulo, São Paulo, Brazil
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, UK.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China.,National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
10
|
Wang B, Yang L, Cheng J, Wang J, Mei Y. In-vivo high-speed biomechanical imaging of the cornea using Corvis ST and digital image correlation. Comput Biol Med 2023; 153:106540. [PMID: 36646022 DOI: 10.1016/j.compbiomed.2023.106540] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2022] [Revised: 12/16/2022] [Accepted: 01/10/2023] [Indexed: 01/12/2023]
Abstract
In-vivo corneal biomechanical characterization has gained significant clinical relevance in ophthalmology, especially in the early diagnosis of eye disorders and diseases (e.g. keratoconus). In clinical medicine, the air-puff-based tonometers such as Ocular Response Analyzer (ORA) and Corvis ST have been used in the in-vivo biomechanical testing. In the test, the high-speed dynamic deformation of the cornea under air-puff excitation is analyzed to identify the abnormities in the morphological and biomechanical properties of the cornea. While most existing measurements reflect the overall corneal biomechanical properties, in-vivo high-speed strain and strain rate fields at the tissue level have not been assessed. In this study, 20 subjects were classified into two different groups: the normal (NORM, N = 10) group and the keratoconus (KC, N = 10) group. Image sequences of the horizontal cross-section of the human cornea under air puff were captured by the Corvis ST tonometer. The macroscale mechanical response of the cornea was determined through image analysis. The high-speed evolution of full-field corneal displacement, strain, velocity, and strain rate was reconstructed using the incremental digital image correlation (DIC) approach. Differences in the parameters between the NORM and KC groups were statistically analyzed and compared. Statistical results indicated that compared with the NORM group, the KC corneas absorbed more energy (KC: 8.98 ± 2.76 mN mm; NORM: 4.79 ± 0.62 mN mm; p-value <0.001) with smaller tangent stiffness (KC: 22.49 ± 2.62 mN/mm; NORM: 24.52 ± 3.20 mN/mm; p-value = 0.15) and larger maximum deflection (KC: 0.99 ± 0.07 mN/mm; NORM: 0.92 ± 0.06 mN/mm; p-value <0.05) on the macro scale. Further, we also observed that The maximum displacement (KC: 1.17 ± 0.06 mm; NORM: 1.06 ± 0.07 mm; p-value <0.005), velocity (KC: 236 ± 29 mm/s; NORM: 203 ± 17 mm/s; p-value <0.01), shear strain (KC: 24.43 ± 2.59%; NORM: 20.26 ± 1.54%; p-value <0.001), and shear strain rate (KC: 69.74 ± 11.99 s-1; NORM: 54.84 ± 3.03 s-1; p-value <0.005) in the KC group significantly increased at the tissue level. This is the first time that the incremental DIC method was applied to the in-vivo high-speed corneal deformation measurement in combination with the Corvis ST tonometer. Through the image registration using incremental DIC analysis, spatiotemporal dynamic strain/strain rate maps of the cornea can be estimated at the tissue level. This is constructive for the clinical recognition and diagnosis of keratoconus at a more underlying level.
Collapse
Affiliation(s)
- Bo Wang
- State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, Dalian, 116023, PR China; International Research Center for Computational Mechanics, Dalian University of Technology, Dalian, 116023, PR China; Ningbo Institute of Dalian University of Technology, Ningbo, 315016, PR China; DUT-BSU Joint Institute, Dalian University of Technology, 116023, PR China
| | - Lanting Yang
- Eye Hospital, Wenzhou Medical University, Wenzhou, China; The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Jiaxuan Cheng
- Eye Hospital, Wenzhou Medical University, Wenzhou, China; The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Junjie Wang
- Eye Hospital, Wenzhou Medical University, Wenzhou, China; The Institution of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China.
| | - Yue Mei
- State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, Dalian, 116023, PR China; International Research Center for Computational Mechanics, Dalian University of Technology, Dalian, 116023, PR China; Ningbo Institute of Dalian University of Technology, Ningbo, 315016, PR China; DUT-BSU Joint Institute, Dalian University of Technology, 116023, PR China.
| |
Collapse
|
11
|
Chou CC, Shih PJ, Jou TS, Hsu MY, Chen JP, Hsu RH, Lee NC, Chien YH, Hwu WL, Wang IJ. Corneal Biomechanical Characteristics in Osteogenesis Imperfecta With Collagen Defect. Transl Vis Sci Technol 2023; 12:14. [PMID: 36622688 PMCID: PMC9838590 DOI: 10.1167/tvst.12.1.14] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Purpose To identify the characteristic corneal biomechanical properties of osteogenesis imperfecta (OI), and to compare the corneal biomechanical properties between OI and keratoconus. Methods We included 46 eyes of 23 patients with OI, 188 eyes of 99 keratoconus patients, and 174 eyes of 92 normal controls to compare corneal biomechanical parameters between OI corneas, keratoconus, and normal controls by using Corneal Visualization Scheimpflug Technology (Corvis ST). Results Patients with OI had significantly higher Corvis biomechanical index (CBI) (P < 0.001), higher tomographic and biomechanical index (TBI) (P = 0.040), lower Corvis Biomechanical Factor (CBiF) (P = 0.034), and lower stiffness parameter at first applanation (SP-A1) (P < 0.001) compared with normal controls. In contrast, OI group showed lower CBI (P < 0.001), lower TBI (P < 0.001), higher CBiF (P < 0.001), and higher SP-A1 (P = 0.020) than keratoconus group. Notably, the stress-strain index (SSI) was not significantly different between the OI and normal controls (P = 1.000), whereas keratoconus showed the lowest SSI compared with OI group (P = 0.025) and normal controls (P < 0.001). Conclusions Although the corneal structures of OI patients are less stable and easier to deform as compared to those of the control group, there is no significant difference in material stiffness observed between the OI and normal controls. In contrast, the corneas of keratoconus showed not only lower structural stability and higher deformability but also lower material stiffness compared with those of OI cornea and normal controls. Translational Relevance The biomechanical alterations are different between OI corneas and keratoconus.
Collapse
Affiliation(s)
- Chien-Chih Chou
- Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan,School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan,Department of Ophthalmology, Taichung Veterans General Hospital, Taichung, Taiwan,Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung, Taiwan
| | - Po-Jen Shih
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Tzuu-Shuh Jou
- Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan,Center of Precision Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Min-Yen Hsu
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan,Department of Ophthalmology, Chung Shan Medical University Hospital, Taichung, Taiwan
| | - Jun-Peng Chen
- Biostatistics Task Force of Taichung Veterans General Hospital, Taichung, Taiwan
| | - Rai-Hseng Hsu
- Department of Medical Genetics, National Taiwan University Hospital, Taipei, Taiwan,Department of Pediatrics, National Taiwan University Hospital, Taipei, Taiwan
| | - Ni-Chung Lee
- Department of Medical Genetics, National Taiwan University Hospital, Taipei, Taiwan,Department of Pediatrics, National Taiwan University Hospital, Taipei, Taiwan
| | - Yin-Hsiu Chien
- Department of Medical Genetics, National Taiwan University Hospital, Taipei, Taiwan,Department of Pediatrics, National Taiwan University Hospital, Taipei, Taiwan
| | - Wuh-Liang Hwu
- Department of Medical Genetics, National Taiwan University Hospital, Taipei, Taiwan,Department of Pediatrics, National Taiwan University Hospital, Taipei, Taiwan
| | - I-Jong Wang
- Graduate Institute of Clinical Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan,Graduate Institute of Clinical Medical Science, China Medical University, Taichung, Taiwan,Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan
| |
Collapse
|
12
|
McAuley R, Nolan A, Curatolo A, Alexandrov S, Zvietcovich F, Varea Bejar A, Marcos S, Leahy M, Birkenfeld JS. Co-axial acoustic-based optical coherence vibrometry probe for the quantification of resonance frequency modes in ocular tissue. Sci Rep 2022; 12:18834. [PMID: 36336702 PMCID: PMC9637745 DOI: 10.1038/s41598-022-21978-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 10/07/2022] [Indexed: 11/08/2022] Open
Abstract
We present a co-axial acoustic-based optical coherence vibrometry probe (CoA-OCV) for vibro-acoustic resonance quantification in biological tissues. Sample vibrations were stimulated via a loudspeaker, and pre-compensation was used to calibrate the acoustic spectrum. Sample vibrations were measured via phase-sensitive swept-source optical coherence tomography (OCT). Resonance frequencies of corneal phantoms were measured at varying intraocular pressures (IOP), and dependencies on Young´s Modulus (E), phantom thickness and IOP were observed. Cycling IOP revealed hysteresis. For E = 0.3 MPa, resonance frequencies increased with IOP at a rate of 3.9, 3.7 and 3.5 Hz/mmHg for varied thicknesses and 1.7, 2.5 and 2.8 Hz/mmHg for E = 0.16 MPa. Resonance frequencies increased with thickness at a rate of 0.25 Hz/µm for E = 0.3 MPa, and 0.40 Hz/µm for E = 0.16 MPa. E showed the most predominant impact in the shift of the resonance frequencies. Full width at half maximum (FWHM) of the resonance modes increased with increasing thickness and decreased with increasing E. Only thickness and E contributed to the variance of FWHM. In rabbit corneas, resonance frequencies of 360-460 Hz were observed. The results of the current study demonstrate the feasibility of CoA-OCV for use in future OCT-V studies.
Collapse
Affiliation(s)
- Ryan McAuley
- Tissue Optics and Microcirculation Imaging Facility, School of Physics, University of Galway, Galway, Ireland.
| | - A Nolan
- Tissue Optics and Microcirculation Imaging Facility, School of Physics, University of Galway, Galway, Ireland
| | - A Curatolo
- Instituto de Óptica, Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland
- International Centre for Translational Eye Research, Warsaw, Poland
| | - S Alexandrov
- Tissue Optics and Microcirculation Imaging Facility, School of Physics, University of Galway, Galway, Ireland
| | - F Zvietcovich
- Instituto de Óptica, Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - A Varea Bejar
- Instituto de Óptica, Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - S Marcos
- Instituto de Óptica, Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
- Center for Visual Science, The Institute of Optics, Flaum Eye Institute, University of Rochester, Rochester, New York, USA
| | - M Leahy
- Tissue Optics and Microcirculation Imaging Facility, School of Physics, University of Galway, Galway, Ireland
| | - J S Birkenfeld
- Instituto de Óptica, Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain.
| |
Collapse
|
13
|
Redaelli E, Grasa J, Calvo B, Rodriguez Matas JF, Luraghi G. A detailed methodology to model the Non Contact Tonometry: a Fluid Structure Interaction study. Front Bioeng Biotechnol 2022; 10:981665. [PMID: 36267451 PMCID: PMC9576856 DOI: 10.3389/fbioe.2022.981665] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 09/13/2022] [Indexed: 11/21/2022] Open
Abstract
Understanding the corneal mechanical properties has great importance in the study of corneal pathologies and the prediction of refractive surgery outcomes. Non-Contact Tonometry (NCT) is a non-invasive diagnostic tool intended to characterize the corneal tissue response in vivo by applying a defined air-pulse. The biomarkers inferred from this test can only be considered as indicators of the global biomechanical behaviour rather than the intrinsic biomechanical properties of the corneal tissue. A possibility to isolate the mechanical response of the corneal tissue is the use of an inverse finite element method, which is based on accurate and reliable modelling. Since a detailed methodology is still missing in the literature, this paper aims to construct a high-fidelity finite-element model of an idealized 3D eye for in silico NCT. A fluid-structure interaction (FSI) simulation is developed to virtually apply a defined air-pulse to a 3D idealized eye model comprising cornea, limbus, sclera, lens and humors. Then, a sensitivity analysis is performed to examine the influence of the intraocular pressure (IOP) and the structural material parameters on three biomarkers associated with corneal deformation. The analysis reveals the requirements for the in silico study linked to the correct reproduction of three main aspects: the air pressure over the cornea, the biomechanical properties of the tissues, and the IOP. The adoption of an FSI simulation is crucial to capture the correct air pressure profile over the cornea as a consequence of the air-jet. Regarding the parts of the eye, an anisotropic material should be used for the cornea. An important component is the sclera: the stiffer the sclera, the lower the corneal deformation due to the air-puff. Finally, the fluid-like behavior of the humors should be considered in order to account for the correct variation of the IOP during the test which will, otherwise, remain constant. The development of a strong FSI tool amenable to model coupled structures and fluids provides the basis to find the biomechanical properties of the corneal tissue in vivo.
Collapse
Affiliation(s)
- Elena Redaelli
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- *Correspondence: Elena Redaelli,
| | - Jorge Grasa
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomecánica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Begoña Calvo
- Aragón Institute of Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Centro de Investigación Biomecánica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Jose Felix Rodriguez Matas
- LaBS, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milan, Italy
| | - Giulia Luraghi
- LaBS, Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milan, Italy
| |
Collapse
|
14
|
Lopes BT, Padmanabhan P, Eliasy A, Zhang H, Abass A, Elsheikh A. In vivo Assessment of Localised Corneal Biomechanical Deterioration With Keratoconus Progression. Front Bioeng Biotechnol 2022; 10:812507. [PMID: 35757796 PMCID: PMC9213735 DOI: 10.3389/fbioe.2022.812507] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 05/20/2022] [Indexed: 11/30/2022] Open
Abstract
Purpose: To evaluate the regional corneal biomechanical deterioration with keratoconus (KC) progression as measured by the Stress-Strain Index (SSI) maps. Methods: The preoperative examinations of 29 progressive KC cases that were submitted to corneal cross-linking (CXL) were evaluated. The examinations included the tomography and the SSI measured by the Pentacam HR and the Corvis ST (Oculus, Wetzlar, Germany), respectively. The results were recorded twice, the latter of which was at the last visit before the CXL procedure. The patient-specific SSI maps were built, using data at each examination, based on finite element modelling and employing inverse analysis to represent the regional variation of biomechanical stiffness across the cornea. Results: All cases presented significant shape progression (above the 95% CI of repeatability) in anterior and posterior curvatures and minimum thickness. The overall corneal stiffness as measured by the SSI within the central 8 mm-diameter area underwent slight but significant reductions from the first to the last examination (−0.02 ± 0.02, range: −0.09 to 0, p < 0.001). In all 29 cases, the reduction in stiffness was localised and concentred in the area inside the keratoconus cone. The SSI values inside the cone were significantly lower in the last examination (by 0.15 ± 0.09, range: −0.42 to −0.01, p < 0.001), while the SSI outside the cone presented minimal, non-significant variations (0 ± 0.01, range: −0.04 to 0.01, p = 0.999). Conclusion: It has been observed through the SSI maps that the regional deterioration in stiffness was concerted inside the area of pathology, while only mild non-significant alterations were observed outside the area of pathology.
Collapse
Affiliation(s)
- Bernardo T Lopes
- School of Engineering, University of Liverpool, Liverpool, United Kingdom.,Department of Ophthalmology, Federal University of São Paulo, São Paulo, Brazil
| | - Prema Padmanabhan
- Department of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| | - Haixia Zhang
- School of Engineering, University of Liverpool, Liverpool, United Kingdom.,School of Biomedical Engineering, Capital Medical University, Beijing, China
| | - Ahmed Abass
- School of Engineering, University of Liverpool, Liverpool, United Kingdom.,Department of Production Engineering and Mechanical Design, Faculty of Engineering, Port Said University, Port Fuad, Egypt
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, United Kingdom.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China.,National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
| |
Collapse
|
15
|
Zingale E, Romeo A, Rizzo S, Cimino C, Bonaccorso A, Carbone C, Musumeci T, Pignatello R. Fluorescent Nanosystems for Drug Tracking and Theranostics: Recent Applications in the Ocular Field. Pharmaceutics 2022; 14:pharmaceutics14050955. [PMID: 35631540 PMCID: PMC9147643 DOI: 10.3390/pharmaceutics14050955] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 04/23/2022] [Accepted: 04/25/2022] [Indexed: 12/14/2022] Open
Abstract
The greatest challenge associated with topical drug delivery for the treatment of diseases affecting the posterior segment of the eye is to overcome the poor bioavailability of the carried molecules. Nanomedicine offers the possibility to overcome obstacles related to physiological mechanisms and ocular barriers by exploiting different ocular routes. Functionalization of nanosystems by fluorescent probes could be a useful strategy to understand the pathway taken by nanocarriers into the ocular globe and to improve the desired targeting accuracy. The application of fluorescence to decorate nanocarrier surfaces or the encapsulation of fluorophore molecules makes the nanosystems a light probe useful in the landscape of diagnostics and theranostics. In this review, a state of the art on ocular routes of administration is reported, with a focus on pathways undertaken after topical application. Numerous studies are reported in the first section, confirming that the use of fluorescent within nanoparticles is already spread for tracking and biodistribution studies. The first section presents fluorescent molecules used for tracking nanosystems’ cellular internalization and permeation of ocular tissues; discussions on the classification of nanosystems according to their nature (lipid-based, polymer-based, metallic-based and protein-based) follows. The following sections are dedicated to diagnostic and theranostic uses, respectively, which represent an innovation in the ocular field obtained by combining dual goals in a single administration system. For its great potential, this application of fluorescent nanoparticles would experience a great development in the near future. Finally, a brief overview is dedicated to the use of fluorescent markers in clinical trials and the market in the ocular field.
Collapse
Affiliation(s)
- Elide Zingale
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
| | - Alessia Romeo
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
| | - Salvatore Rizzo
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
| | - Cinzia Cimino
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
| | - Angela Bonaccorso
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
- NANO-i—Research Center for Ocular Nanotechnology, University of Catania, 95124 Catania, Italy
| | - Claudia Carbone
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
- NANO-i—Research Center for Ocular Nanotechnology, University of Catania, 95124 Catania, Italy
| | - Teresa Musumeci
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
- NANO-i—Research Center for Ocular Nanotechnology, University of Catania, 95124 Catania, Italy
| | - Rosario Pignatello
- Department of Pharmaceutical and Health Sciences, University of Catania, 95124 Catania, Italy; (E.Z.); (A.R.); (S.R.); (C.C.); (A.B.); (C.C.); (T.M.)
- NANO-i—Research Center for Ocular Nanotechnology, University of Catania, 95124 Catania, Italy
- Correspondence:
| |
Collapse
|
16
|
Padmanabhan P, Lopes BT, Eliasy A, Abass A, Elsheikh A. In vivo biomechanical changes associated with Keratoconus progression. Curr Eye Res 2022; 47:982-986. [PMID: 35385372 DOI: 10.1080/02713683.2022.2058020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Purpose: To assess the biomechanical deterioration arising from keratoconus progression in-vivo.Materials and Methods: The preoperative examinations of 32 progressive KC cases that were submitted to corneal cross-linking were evaluated. The examinations included the corneal tomography using the Pentacam HR and biomechanical parameters assessed by the Corvis ST (Oculus, Wetzlar, Germany). The results were recorded at two time points, the latter of which was at the last visit before the CXL procedure. Keratoconus progression was characterised by a significant change in the ABCD system.Results: At the last follow-up visit (41.4 ± 40.9 months) all morphological parameters of the ABCD grading system showed significant deterioration (p < 0.001). The comparative analyses revealed a significant reduction in corneal stiffness expressed by a significant reduction in the stress-strain index (SSI: -0.10 ± 0.06, p < 0.001), the Stiffness parameter A1 (SP-A1: -6.1 ± 12.0 mmHg/mm, p = 0.011), by a significant increase in the integrated Inverse Radius (IIR: 0.95 ± 1.04 mm-1, p < 0.001) and in the deflection amplitude (DA) ratio (0.23 ± 0.58, p = 0.034). A barely significant increase in the DA also pointed towards corneal stiffness reduction. (0.04 ± 0.13 mm, p = 0.056). The SSI and the IIR were the indices with the smallest overlaps between the two examinations.Conclusions: It has been demonstrated in-vivo that corneal biomechanical deterioration occurs with keratoconus progression. The larger changes observed in the SSI and the IIR when compared to the remaining biomechanical parameters suggests that these parameters could be suitable to assess the corneal stiffness reduction in keratoconus natural progression.
Collapse
Affiliation(s)
- Prema Padmanabhan
- Department of Cornea and Refractive Surgery, Sankara Nethralaya, Chennai, India
| | - Bernardo T Lopes
- School of Engineering, University of Liverpool, Liverpool, UK.,Department of Ophthalmology, Federal University of São Paulo, São Paulo, Brazil
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool, UK
| | - Ahmed Abass
- School of Engineering, University of Liverpool, Liverpool, UK.,Department of Production Engineering and Mechanical Design, Faculty of Engineering, Port Said University, Egypt
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, UK.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China.,National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
17
|
A Review on Damage and Rupture Modelling for Soft Tissues. Bioengineering (Basel) 2022; 9:bioengineering9010026. [PMID: 35049735 PMCID: PMC8773318 DOI: 10.3390/bioengineering9010026] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Revised: 01/04/2022] [Accepted: 01/05/2022] [Indexed: 11/16/2022] Open
Abstract
Computational modelling of damage and rupture of non-connective and connective soft tissues due to pathological and supra-physiological mechanisms is vital in the fundamental understanding of failures. Recent advancements in soft tissue damage models play an essential role in developing artificial tissues, medical devices/implants, and surgical intervention practices. The current article reviews the recently developed damage models and rupture models that considered the microstructure of the tissues. Earlier review works presented damage and rupture separately, wherein this work reviews both damage and rupture in soft tissues. Wherein the present article provides a detailed review of various models on the damage evolution and tear in soft tissues focusing on key conceptual ideas, advantages, limitations, and challenges. Some key challenges of damage and rupture models are outlined in the article, which helps extend the present damage and rupture models to various soft tissues.
Collapse
|
18
|
Qiao X, Chen D, Huo H, Tang M, Tang Z, Dong Y, Liu X, Fan Y. Full-field strain mapping for characterization of structure-related variation in corneal biomechanical properties using digital image correlation (DIC) technology. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2021. [DOI: 10.1016/j.medntd.2021.100086] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|