1
|
Li W, Li X, Zhang C, Wang H, Zhu Y, Wang Y, Yan W, Liu L, Qu J. Research of Pulmonary Fibrosis Lesions Based on FLIM and SHG Imaging Microscopy. Anal Chem 2024. [PMID: 39012837 DOI: 10.1021/acs.analchem.4c01303] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/18/2024]
Abstract
Two-photon fluorescence lifetime microscopy (TP-FLIM) is a powerful quantitative imaging technique that characterizes and analyzes the structure and function of biological samples through a combination of intensity and lifetime imaging. Because TP-FLIM is independent of the fluorescence signal intensity and the fluorophore concentration, it is widely used in high-throughput, high-content drug screening and clinical diagnostics. Second harmonic generation (SHG) imaging technology has the advantages of high spatial resolution and imaging depth inherent to nonlinear optical imaging. Second harmonics often appear in noncentrosymmetric structures. Collagen tissue in biological organisms is a good example of these structures, showing strong harmonic effects. Therefore, SHG has been widely used for imaging of specific tissue structure imaging. TP-FLIM technology is highly sensitive for quantitatively detecting changes in microenvironments. The objective of this study is to examine pathological pulmonary fibrosis slices using a combined approach of TP-FLIM and SHG technology. The fluorescence lifetime data of pulmonary collagen fibers are analyzed by using phasor plot analysis methods, and normal collagen fibers and fibrotic collagen fibers are distinguished by calculating the aspect ratio from the SHG images formed by the collagen fibers. Our study provides a new method for a deeper understanding of the pathological mechanisms and clinical diagnosis of pulmonary fibrosis and other collagen fiber-related disorders.
Collapse
Affiliation(s)
- Wei Li
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Xiaoyu Li
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Chenshuang Zhang
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - He Wang
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Yinru Zhu
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Yunyun Wang
- Department of Forensic Medicine, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China
- Chongxin Judicial Expertise Center, Wuhan, Hubei 430415, China
| | - Wei Yan
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Liwei Liu
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| | - Junle Qu
- College of Physics and Optoelectronic Engineering, Shenzhen Key Laboratory of Photonics and Biophotonics, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, Shenzhen University, Shenzhen, Guangdong 518060, China
| |
Collapse
|
2
|
Chen P, Kang Q, Niu J, Jing Y, Zhang X, Yu B, Qu J, Lin D. Fluorescence lifetime tracking and imaging of single moving particles assisted by a low-photon-count analysis algorithm. BIOMEDICAL OPTICS EXPRESS 2023; 14:1718-1731. [PMID: 37078048 PMCID: PMC10110318 DOI: 10.1364/boe.485729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/06/2023] [Accepted: 03/06/2023] [Indexed: 05/03/2023]
Abstract
Fluorescence lifetime imaging microscopy (FLIM) has been widely used in the field of biological research because of its high specificity, sensitivity, and quantitative ability in the sensing cellular microenvironment. The most commonly used FLIM technology is based on time-correlated single photon counting (TCSPC). Although the TCSPC method has the highest temporal resolution, the data acquisition time is usually long, and the imaging speed is slow. In this work, we proposed a fast FLIM technology for fluorescence lifetime tracking and imaging of single moving particles, named single particle tracking FLIM (SPT-FLIM). We used feedback-controlled addressing scanning and Mosaic FLIM mode imaging to reduce the number of scanned pixels and the data readout time, respectively. Moreover, we developed a compressed sensing analysis algorithm based on alternating descent conditional gradient (ADCG) for low-photon-count data. We applied the ADCG-FLIM algorithm on both simulated and experimental datasets to evaluate its performance. The results showed that ADCG-FLIM could achieve reliable lifetime estimation with high accuracy and precision in the case of a photon count less than 100. By reducing the photon count requirement for each pixel from, typically, 1000 to 100, the acquisition time for a single frame lifetime image could be significantly shortened, and the imaging speed could be improved to a great extent. On this basis, we obtained lifetime trajectories of moving fluorescent beads using the SPT-FLIM technique. Overall, our work offers a powerful tool for fluorescence lifetime tracking and imaging of single moving particles, which will promote the application of TCSPC-FLIM in biological research.
Collapse
|
3
|
Yabuno M, Takumi T, China F, Miki S, Terai H, Mosley PJ, Jin RB, Shimizu R. Ultrafast measurement of a single-photon wave packet using an optical Kerr gate. OPTICS EXPRESS 2022; 30:4999-5007. [PMID: 35209471 DOI: 10.1364/oe.446010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Accepted: 01/24/2022] [Indexed: 06/14/2023]
Abstract
Ultrafast quantum optics with time-frequency entangled photons is at the forefront of progress towards future quantum technologies. However, to unravel the time domain structure of entangled photons and exploit fully their rich dimensionality, a single-photon detector with sub-picosecond temporal resolution is required. Here, we present ultrafast single-photon detection using an optical Kerr gate composed of a photonic crystal fiber (PCF) placed inside a Sagnac interferometer. A near-rectangle temporal waveform of a heralded single-photon generated via spontaneous parametric down-conversion is measured with temporal resolution as high as 224 ± 9 fs. The large nonlinearity and long effective interaction length of the PCF enables maximum detection efficiency to be achieved with only 30.5 mW gating pulse average power, demonstrating an order-of-magnitude improvement compared to optical gating with sum-frequency generation. Also, we discuss the trade-off relationship between detection efficiency and temporal resolution.
Collapse
|
4
|
Williams GOS, Williams E, Finlayson N, Erdogan AT, Wang Q, Fernandes S, Akram AR, Dhaliwal K, Henderson RK, Girkin JM, Bradley M. Full spectrum fluorescence lifetime imaging with 0.5 nm spectral and 50 ps temporal resolution. Nat Commun 2021; 12:6616. [PMID: 34785666 PMCID: PMC8595732 DOI: 10.1038/s41467-021-26837-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2019] [Accepted: 10/15/2021] [Indexed: 11/23/2022] Open
Abstract
The use of optical techniques to interrogate wide ranging samples from semiconductors to biological tissue for rapid analysis and diagnostics has gained wide adoption over the past decades. The desire to collect ever more spatially, spectrally and temporally detailed optical signatures for sample characterization has specifically driven a sharp rise in new optical microscopy technologies. Here we present a high-speed optical scanning microscope capable of capturing time resolved images across 512 spectral and 32 time channels in a single acquisition with the potential for ~0.2 frames per second (256 × 256 image pixels). Each pixel in the resulting images contains a detailed data cube for the study of diverse time resolved light driven phenomena. This is enabled by integration of system control electronics and on-chip processing which overcomes the challenges presented by high data volume and low imaging speed, often bottlenecks in previous systems. High data volumes from multidimensional imaging techniques can lead to slow collection and processing times. Here, the authors implement multispectral fluorescence lifetime imaging microscopy (FLIM) that uses time-correlated photon counting technology to reach simultaneously high imaging rates combined with high spectral and temporal resolution.
Collapse
Affiliation(s)
- Gareth O S Williams
- Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Elvira Williams
- Centre for Advanced Instrumentation, Department of Physics, Durham University, South Road, Durham, DH1 3LE, UK
| | - Neil Finlayson
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, King's Buildings, Alexander Crum Brown Road, Edinburgh, EH9 3FF, UK
| | - Ahmet T Erdogan
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, King's Buildings, Alexander Crum Brown Road, Edinburgh, EH9 3FF, UK
| | - Qiang Wang
- Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Susan Fernandes
- Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Ahsan R Akram
- Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Kev Dhaliwal
- Centre for Inflammation Research, Queen's Medical Research Institute, University of Edinburgh, 47 Little France Crescent, Edinburgh, EH16 4TJ, UK
| | - Robert K Henderson
- School of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, King's Buildings, Alexander Crum Brown Road, Edinburgh, EH9 3FF, UK
| | - John M Girkin
- Centre for Advanced Instrumentation, Department of Physics, Durham University, South Road, Durham, DH1 3LE, UK.
| | - Mark Bradley
- School of Chemistry, University of Edinburgh, David Brewster Road, Edinburgh, EH9 3FJ, UK.
| |
Collapse
|
5
|
Becker L, Janssen N, Layland SL, Mürdter TE, Nies AT, Schenke-Layland K, Marzi J. Raman Imaging and Fluorescence Lifetime Imaging Microscopy for Diagnosis of Cancer State and Metabolic Monitoring. Cancers (Basel) 2021; 13:cancers13225682. [PMID: 34830837 PMCID: PMC8616063 DOI: 10.3390/cancers13225682] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 11/05/2021] [Accepted: 11/10/2021] [Indexed: 02/08/2023] Open
Abstract
Hurdles for effective tumor therapy are delayed detection and limited effectiveness of systemic drug therapies by patient-specific multidrug resistance. Non-invasive bioimaging tools such as fluorescence lifetime imaging microscopy (FLIM) and Raman-microspectroscopy have evolved over the last decade, providing the potential to be translated into clinics for early-stage disease detection, in vitro drug screening, and drug efficacy studies in personalized medicine. Accessing tissue- and cell-specific spectral signatures, Raman microspectroscopy has emerged as a diagnostic tool to identify precancerous lesions, cancer stages, or cell malignancy. In vivo Raman measurements have been enabled by recent technological advances in Raman endoscopy and signal-enhancing setups such as coherent anti-stokes Raman spectroscopy or surface-enhanced Raman spectroscopy. FLIM enables in situ investigations of metabolic processes such as glycolysis, oxidative stress, or mitochondrial activity by using the autofluorescence of co-enzymes NADH and FAD, which are associated with intrinsic proteins as a direct measure of tumor metabolism, cell death stages and drug efficacy. The combination of non-invasive and molecular-sensitive in situ techniques and advanced 3D tumor models such as patient-derived organoids or microtumors allows the recapitulation of tumor physiology and metabolism in vitro and facilitates the screening for patient-individualized drug treatment options.
Collapse
Affiliation(s)
- Lucas Becker
- Department for Medical Technologies and Regenerative Medicine, Institute of Biomedical Engineering, University of Tübingen, 72076 Tübingen, Germany
- Cluster of Excellence iFIT (EXC 2180) "Image-Guided and Functionally Instructed Tumor Therapies", University of Tübingen, 72076 Tübingen, Germany
| | - Nicole Janssen
- Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology, University of Tübingen, 72076 Tübingen, Germany
| | - Shannon L Layland
- Department for Medical Technologies and Regenerative Medicine, Institute of Biomedical Engineering, University of Tübingen, 72076 Tübingen, Germany
| | - Thomas E Mürdter
- Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology, University of Tübingen, 72076 Tübingen, Germany
| | - Anne T Nies
- Cluster of Excellence iFIT (EXC 2180) "Image-Guided and Functionally Instructed Tumor Therapies", University of Tübingen, 72076 Tübingen, Germany
- Dr. Margarete Fischer-Bosch Institute of Clinical Pharmacology, University of Tübingen, 72076 Tübingen, Germany
| | - Katja Schenke-Layland
- Department for Medical Technologies and Regenerative Medicine, Institute of Biomedical Engineering, University of Tübingen, 72076 Tübingen, Germany
- Cluster of Excellence iFIT (EXC 2180) "Image-Guided and Functionally Instructed Tumor Therapies", University of Tübingen, 72076 Tübingen, Germany
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
- Cardiovascular Research Laboratories, Department of Medicine/Cardiology, David Geffen School of Medicine, UCLA, Los Angeles, CA 90073, USA
| | - Julia Marzi
- Department for Medical Technologies and Regenerative Medicine, Institute of Biomedical Engineering, University of Tübingen, 72076 Tübingen, Germany
- Cluster of Excellence iFIT (EXC 2180) "Image-Guided and Functionally Instructed Tumor Therapies", University of Tübingen, 72076 Tübingen, Germany
- NMI Natural and Medical Sciences Institute at the University of Tübingen, 72770 Reutlingen, Germany
| |
Collapse
|
6
|
Li Y, Sapermsap N, Yu J, Tian J, Chen Y, Day-Uei Li D. Histogram clustering for rapid time-domain fluorescence lifetime image analysis. BIOMEDICAL OPTICS EXPRESS 2021; 12:4293-4307. [PMID: 34457415 PMCID: PMC8367240 DOI: 10.1364/boe.427532] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/30/2021] [Accepted: 06/08/2021] [Indexed: 05/03/2023]
Abstract
We propose a histogram clustering (HC) method to accelerate fluorescence lifetime imaging (FLIM) analysis in pixel-wise and global fitting modes. The proposed method's principle was demonstrated, and the combinations of HC with traditional FLIM analysis were explained. We assessed HC methods with both simulated and experimental datasets. The results reveal that HC not only increases analysis speed (up to 106 times) but also enhances lifetime estimation accuracy. Fast lifetime analysis strategies were suggested with execution times around or below 30 μs per histograms on MATLAB R2016a, 64-bit with the Intel Celeron CPU (2950M @ 2GHz).
Collapse
Affiliation(s)
- Yahui Li
- Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi'an Institute of Optics and Precision Mechanics, Xi'an Shaanxi 710049, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan Shanxi 030006, China
| | - Natakorn Sapermsap
- Department of Physics, Scottish Universities Physics Alliance, University of Strathclyde, Glasgow, G4 0NG, United Kingdom
| | - Jun Yu
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow G4 0RE, United Kingdom
| | - Jinshou Tian
- Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi'an Institute of Optics and Precision Mechanics, Xi'an Shaanxi 710049, China
- Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan Shanxi 030006, China
| | - Yu Chen
- Department of Physics, Scottish Universities Physics Alliance, University of Strathclyde, Glasgow, G4 0NG, United Kingdom
| | - David Day-Uei Li
- Department of Biomedical Engineering, University of Strathclyde, Glasgow G1 0NW, United Kingdom
| |
Collapse
|
7
|
Tsao CW, Fang MJ, Hsu YJ. Modulation of interfacial charge dynamics of semiconductor heterostructures for advanced photocatalytic applications. Coord Chem Rev 2021. [DOI: 10.1016/j.ccr.2021.213876] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
8
|
Li Y, Tian J, Li DDU. Theoretical investigations of a modified compressed ultrafast photography method suitable for single-shot fluorescence lifetime imaging. APPLIED OPTICS 2021; 60:1476-1483. [PMID: 33690594 DOI: 10.1364/ao.415594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Accepted: 01/15/2021] [Indexed: 06/12/2023]
Abstract
A single-shot fluorescence lifetime imaging (FLIM) method based on the compressed ultrafast photography (CUP) is proposed, named space-restricted CUP (srCUP). srCUP is suitable for imaging objects moving slowly (<∼150/Mmm/s, M is the magnification of the objective lens) in the field of view with the intensity changing within nanoseconds in a measurement window around 10 ns. We used synthetic datasets to explore the performances of srCUP compared with CUP and TCUP (a variant of CUP). srCUP not only provides superior reconstruction performances, but its reconstruction speed is also twofold and threefold faster than CUP and TCUP, respectively. The lifetime determination performances were assessed by estimating lifetime components, amplitude- and intensity-weighted average lifetimes (τA and τI), with the reconstructed scenes using the least squares method based on a bi-exponential model. srCUP has the best accuracy and precision for lifetime determinations with a relative bias less than 7% and a coefficient of variation less than 7% for τA, and a relative bias less than 10% and a coefficient of variation less than 11% for τI.
Collapse
|
9
|
Ankri R, Basu A, Ulku AC, Bruschini C, Charbon E, Weiss S, Michalet X. Single-Photon, Time-Gated, Phasor-Based Fluorescence Lifetime Imaging through Highly Scattering Medium. ACS PHOTONICS 2020; 7:68-79. [PMID: 35936550 PMCID: PMC9355389 DOI: 10.1021/acsphotonics.9b00874] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Fluorescence lifetime imaging (FLI) is increasingly recognized as a powerful tool for biochemical and cellular investigations, including in vivo applications. Fluorescence lifetime is an intrinsic characteristic of any fluorescent dye which, to a large extent, does not depend on excitation intensity and signal level. In particular, it allows distinguishing dyes with similar emission spectra, offering additional multiplexing capabilities. However, in vivo FLI in the visible range is complicated by the contamination by (i) tissue autofluorescence, which decreases contrast, and by (ii) light scattering and absorption in tissues, which significantly reduce fluorescence intensity and modify the temporal profile of the signal. Here, we demonstrate how these issues can be accounted for and overcome, using a new time-gated single-photon avalanche diode array camera, SwissSPAD2, combined with phasor analysis to provide a simple and fast visual method for lifetime imaging. In particular, we show how phasor dispersion increases with increasing scattering and/or decreasing fluorescence intensity. Next, we show that as long as the fluorescence signal of interest is larger than the phantom autofluorescence, the presence of a distinct lifetime can be clearly identified with appropriate background correction. We use these results to demonstrate the detection of A459 cells expressing the fluorescent protein mCyRFP1 through highly scattering and autofluorescent phantom layers. These results showcase the possibility to perform FLI in challenging conditions, using standard, bright, visible fluorophore or fluorescence proteins.
Collapse
Affiliation(s)
- Rinat Ankri
- Department of Chemistry & Biochemistry, UCLA, Los Angeles, California 90095, United States
- Corresponding Authors:.
| | - Arkaprabha Basu
- Department of Chemistry & Biochemistry, UCLA, Los Angeles, California 90095, United States
| | - Arin Can Ulku
- School of Engineering, École Polytechnique Fédérale de Lausanne, Neuchâtel 1015, Switzerland
| | - Claudio Bruschini
- School of Engineering, École Polytechnique Fédérale de Lausanne, Neuchâtel 1015, Switzerland
| | - Edoardo Charbon
- School of Engineering, École Polytechnique Fédérale de Lausanne, Neuchâtel 1015, Switzerland
| | - Shimon Weiss
- Department of Chemistry & Biochemistry, UCLA, Los Angeles, California 90095, United States
| | - Xavier Michalet
- Department of Chemistry & Biochemistry, UCLA, Los Angeles, California 90095, United States
- Corresponding Authors:.
| |
Collapse
|
10
|
Evaluation of Quality of Eggs from Hens Kept in Caged and Free-Range Systems Using Traditional Methods and Ultra-Weak Luminescence. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9122430] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The paper presents the results of an evaluation of the quality of eggs from laying hens kept in caged and free range systems using traditional methods and ultra-weak luminescence (USL). It was found that the tested eggs were fresh and were characterized by the required quality, as demonstrated by analysis of the egg white and egg yolk. Eggs from free-range laying hens were characterized by an eight-fold higher emission of photons compared to eggs from caged hens, and they had over three times higher content of natural antioxidants in the form of carotenoids. Most probably, the higher number of photons emitted is associated with a higher content of biologically active substances in the material under study. Photon emission also varies in different ways depending on the specific hen breeding system. Differences in time in the identified maximum values of photon emission result from the composition of individual parts of the egg. Different times in which the emission peaks occurred for free-range eggs and for caged eggs were observed. The application of the USL method in order to confirm its usefulness in the assessment of food quality requires further research.
Collapse
|
11
|
Manzella-Lapeira J, Brzostowski JA. Imaging Protein-Protein Interactions by Förster Resonance Energy Transfer (FRET) Microscopy in Live Cells. CURRENT PROTOCOLS IN PROTEIN SCIENCE 2018; 93:e58. [PMID: 29984911 DOI: 10.1002/cpps.58] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
This updated unit compares three methods to acquire Förster Resonance Energy Transfer (FRET) data in living cells using a confocal microscope: Acceptor photobleaching, Acceptor-sensitized emission FRET, and Donor fluorescence lifetime imaging. Detailed protocols for live cell husbandry, image acquisition, and data analysis are provided. In addition to providing instructions for manufacturer's analysis tool sets, we provide an easy-to-use, MATLAB-based code to calculate FRET efficiency from data obtained using the Acceptor photobleaching or Acceptor-sensitized emission method, which can be freely downloaded. © 2018 by John Wiley & Sons, Inc.
Collapse
Affiliation(s)
| | - Joseph A Brzostowski
- Twinbrook Imaging Facility, National Institutes of Health/NIAID, Bethesda, Maryland
| |
Collapse
|
12
|
Simultaneous Phosphorescence and Fluorescence Lifetime Imaging by Multi-Dimensional TCSPC and Multi-Pulse Excitation. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1035:19-30. [PMID: 29080128 DOI: 10.1007/978-3-319-67358-5_2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
TCSPC FLIM/PLIM is based on a multi-dimensional time-correlated single-photon counting process. The sample is scanned by a high-frequency-pulsed laser beam which is additionally modulated on/off synchronously with the pixels of the scan. FLIM is obtained by building up the distribution of the photons over the scanning coordinates and the times of the photons in the excitation pulse sequence, PLIM is obtained by building up the photon distribution over the scanning coordinates and the photon times in the modulation period. FLIM and PLIM data are thus obtained simultaneously within the same imaging process. Since the technique uses not only one but many excitation pulses for every phosphorescence signal period the sensitivity is much higher than for techniques that excite with a single pulse only. TCSPC FLIM/PLIM works both with one-photon and two-photon excitation, does not require a reduction of the laser pulse repetition rate by a pulse picker, and eliminates the need of high pulse energy for phosphorescence excitation.
Collapse
|
13
|
Silva SF, Domingues JP, Morgado AM. Accurate Rapid Lifetime Determination on Time-Gated FLIM Microscopy with Optical Sectioning. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:1371386. [PMID: 29599938 PMCID: PMC5823430 DOI: 10.1155/2018/1371386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Revised: 11/21/2017] [Accepted: 12/03/2017] [Indexed: 11/18/2022]
Abstract
Time-gated fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to assess the biochemistry of cells and tissues. When applied to living thick samples, it is hampered by the lack of optical sectioning and the need of acquiring many images for an accurate measurement of fluorescence lifetimes. Here, we report on the use of processing techniques to overcome these limitations, minimizing the acquisition time, while providing optical sectioning. We evaluated the application of the HiLo and the rapid lifetime determination (RLD) techniques for accurate measurement of fluorescence lifetimes with optical sectioning. HiLo provides optical sectioning by combining the high-frequency content from a standard image, obtained with uniform illumination, with the low-frequency content of a second image, acquired using structured illumination. Our results show that HiLo produces optical sectioning on thick samples without degrading the accuracy of the measured lifetimes. We also show that instrument response function (IRF) deconvolution can be applied with the RLD technique on HiLo images, improving greatly the accuracy of the measured lifetimes. These results open the possibility of using the RLD technique with pulsed diode laser sources to determine accurately fluorescence lifetimes in the subnanosecond range on thick multilayer samples, providing that offline processing is allowed.
Collapse
Affiliation(s)
- Susana F. Silva
- Institute for Biomedical Imaging and Life Sciences (IBILI), Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - José Paulo Domingues
- Institute for Biomedical Imaging and Life Sciences (IBILI), Faculty of Medicine, University of Coimbra, Coimbra, Portugal
- Department of Physics, Faculty of Sciences and Technology, University of Coimbra, Coimbra, Portugal
| | - António Miguel Morgado
- Institute for Biomedical Imaging and Life Sciences (IBILI), Faculty of Medicine, University of Coimbra, Coimbra, Portugal
- Department of Physics, Faculty of Sciences and Technology, University of Coimbra, Coimbra, Portugal
| |
Collapse
|
14
|
Oxygen imaging of living cells and tissues using luminescent molecular probes. JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY C-PHOTOCHEMISTRY REVIEWS 2017. [DOI: 10.1016/j.jphotochemrev.2017.01.001] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
15
|
Hoffmann B, Klöcker N, Benndorf K, Biskup C. Visualization of the dynamics of PSD-95 and Kir2.1 interaction by fluorescence lifetime-based resonance energy transfer imaging. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.medpho.2014.11.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
16
|
|
17
|
Fingerprinting of metabolic states by NAD(P)H fluorescence lifetime spectroscopy in living cells: A review. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.medpho.2014.06.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|