1
|
Ma C, Li Y. Clinical effect of different dialyzers used in patients with kidney disease: a meta-analysis of randomized clinical trials. REVISTA DA ASSOCIACAO MEDICA BRASILEIRA (1992) 2023; 69:191-194. [PMID: 36820724 PMCID: PMC9937625 DOI: 10.1590/1806-9282.20220782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 09/23/2022] [Indexed: 02/19/2023]
Affiliation(s)
- Chuncheng Ma
- Jiangmen Wuyi Traditional Chinese Medicine Hospital, Department of Oncology – Jiangmen, China
| | - Yemei Li
- Jiangmen Wuyi Traditional Chinese Medicine Hospital, Department of Oncology – Jiangmen, China.,Corresponding author:
| |
Collapse
|
2
|
Zheng X, Ni C, Xiao W, Yu G, Li Y. In vitro hemocompatibility and hemodialysis performance of hydrophilic ionic liquid grafted polyethersulfone hollow fiber membranes. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.121464] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
3
|
Ren J, Yang X, Yan W, Feng X, Zhao Y, Chen L. mPEG-b-PES-b-mPEG-based candidate hemodialysis membrane with enhanced performance in sieving, flux, and hemocompatibility. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.120680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
A review on hollow fiber membrane module towards high separation efficiency: Process modeling in fouling perspective. CHINESE CHEM LETT 2022. [DOI: 10.1016/j.cclet.2021.10.044] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
5
|
Fabrication and dialysis performance of functionalized multiwall carbon nanotubes integrated cellulose acetate/poly(vinylpyrrolidone) membranes. Int J Biol Macromol 2021; 191:872-880. [PMID: 34571131 DOI: 10.1016/j.ijbiomac.2021.09.131] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 08/21/2021] [Accepted: 09/19/2021] [Indexed: 11/23/2022]
Abstract
Mixed matrix membranes (MMMs) of cellulose acetate/poly(vinylpyrrolidone) (CA/PVP) infused with acid functionalized multiwall carbon nanotubes (f-MWCNTs) were fabricated by an immersion phase separation technique for hemodialysis application. Membranes were characterized using FTIR, water uptake, contact angle, TGA, DMA and SEM analysis. The FTIR was used to confirm the bonding interaction between CA/PVP membrane matrix and f-MWCNTs. Upon addition of f-MWCNTs, TGA thermograms and glass transition temperature indicated improved thermal stability of MMMs. The surface morphological analysis demonstrated revealed uniform distribution of f-MWCNTs and asymmetric membrane structure. The water uptake and contact angle confirmed that hydrophilicity was increased after incorporation of f-MWCNTs. The membranes demonstrated enhancement in water permeate flux, bovine serum albumin (BSA) rejection with the infusion of f-MWCNTs; whereas BSA based anti-fouling analysis using flux recovery ratio test shown up to 8.4% improvement. The urea and creatinine clearance performance of MMMs were evaluated by dialysis experiment. It has been found that f-MWCNTs integrated membranes demonstrated the higher urea and creatinine clearance with increase of 12.6% and 10.5% in comparison to the neat CA/PVP membrane. Thus, the prepared CA/PVP membranes embedded with f-MWCNTs can be employed for wide range of dialysis applications.
Collapse
|
6
|
Zaman SU, Saif-Ur-Rehman, Zaman MKU, Arshad A, Rafiq S, Muhammad N, Saqib S, Jamal M, Wajeeh S, Imtiaz S, Sadiq MT. Biocompatibility performance evaluation of high flux hydrophilic CO3Ap/HAP/PSF composite membranes for hemodialysis application. Artif Organs 2021; 45:E265-E279. [PMID: 33559192 DOI: 10.1111/aor.13937] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 01/08/2021] [Accepted: 02/01/2021] [Indexed: 11/26/2022]
Abstract
Carbonate apatite/hydroxyapatite (CO3Ap/HAP) additive was obtained by calcination of wasted chicken bones at 900°C. Intermolecular attraction exists between CO3Ap/HAP additive and blended polysulfone (PSF) polymer. Electron dispersive X-ray (EDX) and FTIR analysis were carried out to check the elemental composition and bonding chemistry of prepared additive. The instantaneous demixing process generated consistent finger-like networks in CO3Ap/HAP/PSF-based composite membranes while sponge-like structure was shown by PSF as revealed by SEM images. The increase in weight % of additive loading is also confirmed by EDX analysis. Furthermore, the interaction mechanism of CO3Ap/HAP additive with polysulfone medium was analyzed by FTIR exploration. The water absorption experiment defined a 93% expansion in hydrophilic performance. Change in porosity occurs with additive loading and pure water permeation flux improved up to 11 times. Approximately, antifouling results revealed that 87% of water flux was recovered after treating with a protein solution, whereas a 30% improvement in antifouling capability in case of bovine serum albumin solution occurred. In vitro cytotoxicity, and clotting times study was carried out to evaluate virulent behavior and anticoagulation activity of formulated membranes.
Collapse
Affiliation(s)
- Shafiq Uz Zaman
- Department of Chemical Engineering, COMSATS University Islamabad, Lahore campus, Pakistan
| | - Saif-Ur-Rehman
- Department of Chemical Engineering, COMSATS University Islamabad, Lahore campus, Pakistan
| | | | - Amber Arshad
- Department of Community Medicine, King Edward Medical University, Lahore, Pakistan
| | - Sikander Rafiq
- Department of Chemical Polymer and Composite Materials Engineering, University of Engineering and Technology, Lahore, Pakistan
| | - Nawshad Muhammad
- Department of Dental Materials, Institute of Basic Medical Sciences, Khyber Medical University, Peshawar, Pakistan
| | - Sidra Saqib
- Department of Chemical Engineering, COMSATS University Islamabad, Lahore campus, Pakistan
| | - Muddasar Jamal
- Interdisciplinary Research Center in Biomedical Materials, COMSATS University Islamabad, Lahore campus, Pakistan
| | - Salman Wajeeh
- Department of Chemistry, University of Gujrat, Punjab, Pakistan
| | - Sania Imtiaz
- Department of Chemistry, Bahauddin Zakariya University, Multan, Pakistan
| | | |
Collapse
|
7
|
Tian X, Qiu YR. 2-methoxyethylacrylate modified polysulfone membrane and its blood compatibility. Arch Biochem Biophys 2017; 631:49-57. [PMID: 28764891 DOI: 10.1016/j.abb.2017.07.018] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 07/26/2017] [Accepted: 07/27/2017] [Indexed: 11/19/2022]
Abstract
Hydrophilic material 2-methoxyethylacrylate (MEA) was grafted onto polysulfone (PSF) membrane via Michael addition reaction. The 1H nuclear magnetic resonance (1H NMR), Attenuated total reflectance-Fourier transform infrared spectroscope (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS) characterization of the modified membrane proved that MEA had been successfully grafted onto PSF membrane surface. The water contact angle of the membrane surface was tested. The results showed that the water contact angle changed from 76° to 59.5°, which means that the hydrophilicity of the modified membrane was improved. A series of blood compatibility tests including bovine serum protein adsorption, platelet adhesion, prothrombin time (PT), partial thromboplastin time (APTT) and thrombin time (TT) were carried out on PSF membrane and the modified PSF membrane with highest grafted density of MEA. All of the results indicate that MEA plays an important role in improving the blood compatibility of PSF membrane.
Collapse
Affiliation(s)
- Xin Tian
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China
| | - Yun-Ren Qiu
- College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, PR China.
| |
Collapse
|
8
|
Fukuda M, Yoshimura K, Namekawa K, Sakai K. Technical characterization of dialysis fluid flow and mass transfer rate in dialyzers with various filtration coefficients using dimensionless correlation equation. J Artif Organs 2017; 20:145-151. [DOI: 10.1007/s10047-016-0942-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2016] [Accepted: 12/11/2016] [Indexed: 11/29/2022]
|
9
|
Ngadiman NHA, Idris A, Irfan M, Kurniawan D, Yusof NM, Nasiri R. γ-Fe2O3 nanoparticles filled polyvinyl alcohol as potential biomaterial for tissue engineering scaffold. J Mech Behav Biomed Mater 2015; 49:90-104. [DOI: 10.1016/j.jmbbm.2015.04.029] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2015] [Revised: 04/28/2015] [Accepted: 04/30/2015] [Indexed: 12/13/2022]
|
10
|
Kee CM, Idris A. Modification of cellulose acetate membrane using monosodium glutamate additives prepared by microwave heating. J IND ENG CHEM 2012. [DOI: 10.1016/j.jiec.2012.06.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Modeling of Hemodialysis Operation. Ann Biomed Eng 2010; 38:3347-62. [DOI: 10.1007/s10439-010-0147-7] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2009] [Accepted: 03/17/2010] [Indexed: 11/26/2022]
|
12
|
Tu JW, Ho CD. Two-Dimensional Mass-Transfer Model of a Flat-Plate Dialyzer with Ultrafiltration Operation. Chem Eng Technol 2010. [DOI: 10.1002/ceat.200900566] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
13
|
|
14
|
Su BH, Fu P, Li Q, Tao Y, Li Z, Zao HS, Zhao CS. Evaluation of polyethersulfone highflux hemodialysis membrane in vitro and in vivo. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2008; 19:745-51. [PMID: 17619985 DOI: 10.1007/s10856-007-3006-9] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2006] [Accepted: 03/15/2007] [Indexed: 05/16/2023]
Abstract
A new hemodialysis membrane manufactured by a blend of polyethersulfone (PES) and polyvinylpyrrolidone (PVP) was evaluated in vitro and in vivo. Goat was selected as the experimental animal. The clearance and the reduction ratio after the hemodialysis of small molecules (urea, creatinine, phosphate) for the PES membrane were higher in vitro than that in vivo. The reduction ratio of beta(2)-microglobulin was about 50% after the treatment for 4 h. The biocompatibility profiles of the membranes indicated slight neutropenia and platelet adhesion at the initial stage of the hemodialysis. Electrolyte, blood gas, and blood biochemistry were also analyzed before and after the treatment. The results indicated that PES hollow fiber membrane had a potential widely use for hemodialysis.
Collapse
Affiliation(s)
- Bai-hai Su
- College of Polymer Science and Engineering, State Key Laboratory of Polymer Materials Engineering, National Engineering Research Center for Biomaterials, Sichuan University, Chengdu, P.R. China
| | | | | | | | | | | | | |
Collapse
|
15
|
Idris A, Yet LK. The effect of different molecular weight PEG additives on cellulose acetate asymmetric dialysis membrane performance. J Memb Sci 2006. [DOI: 10.1016/j.memsci.2006.03.010] [Citation(s) in RCA: 115] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
16
|
Wolff SH, Zydney AL. Effect of Peracetic Acid Reprocessing on the Transport Characteristics of Polysulfone Hemodialyzers. Artif Organs 2005; 29:166-73. [PMID: 15670286 DOI: 10.1111/j.1525-1594.2005.29028.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Peracetic acid is used extensively for reprocessing hemodialyzers, despite several indications that reprocessing alters the dialyzer transport characteristics. The objective of this study was to obtain quantitative data for the effects of peracetic acid reprocessing on the clearance and sieving coefficients of urea, vitamin B12, and polydisperse dextrans using Fresenius F80A polysulfone dialyzers. Reprocessing restored the urea and vitamin B12 clearance to close to their original values. However, the reprocessed dialyzers had substantially lower clearance of the larger molecular weight dextrans, which was attributed to reductions in the effective pore size caused by residual plasma proteins within the membrane. Storage in peracetic acid provided some additional removal of residual proteins, although the clearance and sieving coefficients of the larger dextrans remained well below their original values. Peracetic acid caused no degradation of the membrane polymer, in sharp contrast to results obtained with bleach reprocessing.
Collapse
Affiliation(s)
- Susanne H Wolff
- Department of Chemical Engineering, The Pennsylvania State University, University Park, PA 16802, USA
| | | |
Collapse
|
17
|
|