1
|
Chen L, Cheng H, Hu R, Zhao Y, Huang J, Liu JH, Huang CZ, Yang T. Kirkendall Effect-Mediated Transformation of ZIF-67 to NiCo-LDH Nanocages as Oxidase Mimics for Multicolor Point-of-Care Testing of β-Galactosidase Activity and Escherichia coli. Anal Chem 2025; 97:2853-2862. [PMID: 39869181 DOI: 10.1021/acs.analchem.4c05379] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2025]
Abstract
Early and portable detection of pathogenic bacteria is crucial for ensuring food safety, monitoring product quality, and tracing the sources of bacterial infections. Moving beyond traditional plate-culture counting methods, the analysis of active bacterial components offers a rapid means of quantifying bacteria. Here, metal-organic framework (MOF)-derived NiCo-layered double hydroxide nanosheets (LDHs), synthesized via the Kirkendall effect, were employed as highly effective oxidase mimics to generate reactive oxygen species (ROS). These ROS quickly etched gold nanobipyramids (Au NBPs), producing a vivid multicolormetric response. Experimental results and theoretical calculations indicated that the exceptional oxidase-like activity of NiCo-LDHs stemmed from the presence of bimetallic active sites and oxygen vacancies modulating the local electronic structure of LDHs. Additionally, β-galactosidase (β-Gal), a biomarker of Escherichia coli, reacted with p-aminophenyl-β-d-galactopyranoside (PAPG) to form p-aminophenol (PAP), a reducing agent which consumes ROS, thereby inhibiting the etching of Au NBPs. Furthermore, a three-dimensional (3D)-printed point-of-care testing (POCT) shell was designed as a portable device to visually detect β-Gal and E. coli in conjugation with smartphones. This study not only provides a novel approach to the rational design of nanozymes but also establishes a vivid and portably visual biosensing platform for detecting β-Gal activity and pathogenic bacteria.
Collapse
Affiliation(s)
- Lu Chen
- Yunnan Key Laboratory of Modern Separation Analysis and Substance Transformation, College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming 650500, Yunnan Province, P. R. China
| | - Huan Cheng
- Yunnan Key Laboratory of Modern Separation Analysis and Substance Transformation, College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming 650500, Yunnan Province, P. R. China
| | - Rong Hu
- Yunnan Key Laboratory of Modern Separation Analysis and Substance Transformation, College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming 650500, Yunnan Province, P. R. China
| | - Yan Zhao
- Yunnan Key Laboratory of Modern Separation Analysis and Substance Transformation, College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming 650500, Yunnan Province, P. R. China
| | - Jingtao Huang
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, P. R. China
| | - Jia Hui Liu
- Institute of Biomedical Engineering, Kunming Medical University, Kunming 650500, P. R. China
| | - Cheng Zhi Huang
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400715, P. R. China
| | - Tong Yang
- Yunnan Key Laboratory of Modern Separation Analysis and Substance Transformation, College of Chemistry and Chemical Engineering, Yunnan Normal University, Kunming 650500, Yunnan Province, P. R. China
| |
Collapse
|
2
|
Kulkarni MB, Ayachit NH, Aminabhavi TM. A Short Review on Miniaturized Biosensors for the Detection of Nucleic Acid Biomarkers. BIOSENSORS 2023; 13:412. [PMID: 36979624 PMCID: PMC10046286 DOI: 10.3390/bios13030412] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 06/18/2023]
Abstract
Even today, most biomarker testing is executed in centralized, dedicated laboratories using bulky instruments, automated analyzers, and increased analysis time and expenses. The development of miniaturized, faster, low-cost microdevices is immensely anticipated for substituting for these conventional laboratory-oriented assays and transferring diagnostic results directly onto the patient's smartphone using a cloud server. Pioneering biosensor-based approaches might make it possible to test biomarkers with reliability in a decentralized setting, but there are still a number of issues and restrictions that must be resolved before the development and use of several biosensors for the proper understanding of the measured biomarkers of numerous bioanalytes such as DNA, RNA, urine, and blood. One of the most promising processes to address some of the issues relating to the growing demand for susceptible, quick, and affordable analysis techniques in medical diagnostics is the creation of biosensors. This article critically discusses a short review of biosensors used for detecting nucleic acid biomarkers, and their use in biomedical prognostics will be addressed while considering several essential characteristics.
Collapse
Affiliation(s)
- Madhusudan B. Kulkarni
- School of Electronics and Communication Engineering, KLE Technological University, Vidyanagar, Hubballi 580023, Karnataka, India
- Medical Physics Department, Wisconsin Institutes for Medical Research, University of Wisconsin, Madison, WI 53705, USA
| | - Narasimha H. Ayachit
- School of Advanced Sciences, KLE Technological University, Hubballi 580031, Karnataka, India
| | - Tejraj M. Aminabhavi
- School of Advanced Sciences, KLE Technological University, Hubballi 580031, Karnataka, India
| |
Collapse
|
3
|
Nelson AM, Habibi S, DeLancey JOL, Ashton-Miller JA, Burns MA. Electrochemical Sensing of Urinary Chloride Ion Concentration for Near Real-Time Monitoring. BIOSENSORS 2023; 13:331. [PMID: 36979543 PMCID: PMC10046868 DOI: 10.3390/bios13030331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 02/20/2023] [Accepted: 02/21/2023] [Indexed: 06/18/2023]
Abstract
Urinary chloride concentration is a valuable health metric that can aid in the early detection of serious conditions, such as acid base disorders, acute heart failure, and incidences of acute renal failure in the intensive care unit. Physiologically, urinary chloride levels frequently change and are difficult to measure, involving time-consuming and inconvenient lab testing. Thus, near real-time simple sensors are needed to quickly provide actionable data to inform diagnostic and treatment decisions that affect health outcomes. Here, we introduce a chronopotentiometric sensor that utilizes commercially available screen-printed electrodes to accurately quantify clinically relevant chloride concentrations (5-250 mM) in seconds, with no added reagents or electrode surface modification. Initially, the sensor's performance was optimized through the proper selection of current density at a specific chloride concentration, using electrical response data in conjunction with scanning electron microscopy. We developed a unique swept current density algorithm to resolve the entire clinically relevant chloride concentration range, and the chloride sensors can be reliably reused for chloride concentrations less than 50 mM. Lastly, we explored the impact of pH, temperature, conductivity, and additional ions (i.e., artificial urine) on the sensor signal, in order to determine sensor feasibility in complex biological samples. This study provides a path for further development of a portable, near real-time sensor for the quantification of urinary chloride.
Collapse
Affiliation(s)
- Anna M. Nelson
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Sanaz Habibi
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - John O. L. DeLancey
- Department of Obstetrics & Gynecology, University of Michigan, Ann Arbor, MI 48109,USA
| | - James A. Ashton-Miller
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| | - Mark A. Burns
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
4
|
Kulkarni MB, Ayachit NH, Aminabhavi TM. Recent Advances in Microfluidics-Based Electrochemical Sensors for Foodborne Pathogen Detection. BIOSENSORS 2023; 13:246. [PMID: 36832012 PMCID: PMC9954504 DOI: 10.3390/bios13020246] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 02/03/2023] [Accepted: 02/06/2023] [Indexed: 05/22/2023]
Abstract
Using pathogen-infected food that can be unhygienic can result in severe diseases and an increase in mortality rate among humans. This may arise as a serious emergency problem if not appropriately restricted at this point of time. Thus, food science researchers are concerned with precaution, prevention, perception, and immunity to pathogenic bacteria. Expensive, elongated assessment time and the need for skilled personnel are some of the shortcomings of the existing conventional methods. Developing and investigating a rapid, low-cost, handy, miniature, and effective detection technology for pathogens is indispensable. In recent times, there has been a significant scope of interest for microfluidics-based three-electrode potentiostat sensing platforms, which have been extensively used for sustainable food safety exploration because of their progressively high selectivity and sensitivity. Meticulously, scholars have made noteworthy revolutions in signal enrichment tactics, measurable devices, and portable tools, which can be used as an allusion to food safety investigation. Additionally, a device for this purpose must incorporate simplistic working conditions, automation, and miniaturization. In order to meet the critical needs of food safety for on-site detection of pathogens, point-of-care testing (POCT) has to be introduced and integrated with microfluidic technology and electrochemical biosensors. This review critically discusses the recent literature, classification, difficulties, applications, and future directions of microfluidics-based electrochemical sensors for screening and detecting foodborne pathogens.
Collapse
Affiliation(s)
- Madhusudan B. Kulkarni
- Renalyx Healthcare Systems (P) Limited, Bengaluru 560004, Karnataka, India
- School of Electronics and Communication Engineering, KLE Technological University, Hubballi 580031, Karnataka, India
| | - Narasimha H. Ayachit
- School of Advanced Sciences, KLE Technological University, Hubballi 580031, Karnataka, India
| | - Tejraj M. Aminabhavi
- School of Advanced Sciences, KLE Technological University, Hubballi 580031, Karnataka, India
| |
Collapse
|
5
|
Zolti O, Suganthan B, Ramasamy RP. Lab-on-a-Chip Electrochemical Biosensors for Foodborne Pathogen Detection: A Review of Common Standards and Recent Progress. BIOSENSORS 2023; 13:215. [PMID: 36831981 PMCID: PMC9954316 DOI: 10.3390/bios13020215] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Revised: 01/22/2023] [Accepted: 01/30/2023] [Indexed: 05/27/2023]
Abstract
Foodborne pathogens are an important diagnostic target for the food, beverage, and health care industries due to their prevalence and the adverse effects they can cause to public health, food safety, and the economy. The standards that determine whether a given type of food is fit for consumption are set by governments and must be taken into account when designing a new diagnostic tool such as a biosensor platform. In order to meet these stringent detection limits, cost, and reliability standards, recent research has been focused on developing lab-on-a-chip-based approaches for detection devices that use microfluidic channels and platforms. The microfluidics-based devices are designed, developed, and used in different ways to achieve the established common standards for food pathogen testing that enable high throughput, rapid detection, low sample volume, and minimal pretreatment procedures. Combining microfluidic approaches with electrochemical biosensing could offer affordable, portable, and easy to use devices for food pathogen diagnostics. This review presents an analysis of the established common standards and the recent progress made in electrochemical sensors toward the development of future lab-on-a-chip devices that will aid 'collection-to-detection' using a single method and platform.
Collapse
Affiliation(s)
| | | | - Ramaraja P. Ramasamy
- Nano Electrochemistry Laboratory, College of Engineering, University of Georgia, Athens, GA 30602, USA
| |
Collapse
|
6
|
A Co-Printed Nanoslit Surface Plasmon Resonance Structure in Microfluidic Device for LMP-1 Detection. BIOSENSORS 2022; 12:bios12080653. [PMID: 36005049 PMCID: PMC9405854 DOI: 10.3390/bios12080653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 08/12/2022] [Accepted: 08/13/2022] [Indexed: 11/16/2022]
Abstract
This paper reports a novel micro/nanostructure co-hot embossing technique. Gold-capped nanostructures were used as localized surface plasmon resonance (SPR) sensors and were integrated into a microfluidic channel. The advantage of the co-hot embossing technique is that the SPR sensors do not need to be aligned with the microfluidic channel while bonding to it. The integrated SPR sensor and microfluidic channel were first characterized, and the sensitivity of the SPR sensor to the refractive index was found using different concentrations of glycerol solutions. The SPR sensor was also used to quantify latent membrane protein (LMP-1) when modifying anti-LMP-1 at the surface of the SPR sensor. Different concentrations of LMP-1 samples were used to build a calibration curve.
Collapse
|
7
|
Lin CY, Nhat Nguyen UT, Hsieh HY, Tahara H, Chang YS, Wang BY, Gu BC, Dai YH, Wu CC, Tsai IJ, Fan YJ. Peptide-based electrochemical sensor with nanogold enhancement for detecting rheumatoid arthritis. Talanta 2022; 236:122886. [PMID: 34635266 DOI: 10.1016/j.talanta.2021.122886] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/12/2021] [Accepted: 09/12/2021] [Indexed: 01/30/2023]
Abstract
Rheumatoid arthritis (RA), an autoimmune and chronic inflammatory disorder, is an incurable disease. We developed a peptide-based electrochemical sensor using electrochemical impedance spectroscopy that can be used to detect autoantibodies for RA diagnostics. We first validated that the developed peptide showed high sensitivity and could compliment the current gold standard method of an anti-cyclic citrullinated peptide antibody (anti-CCP) ELISA. The developed peptide can be modified on the nanogold surface of the working electrode of sensing chips through the method of a self-assembling monolayer. The sensing process was first optimized using a positive control cohort and a healthy control cohort. Subsequently, 10 clinically confirmed samples from RA patients and five healthy control samples were used to find the threshold value of the impedance between RA and healthy subjects. Furthermore, 10 clinically confirmed samples but with low values of anti-CCP autoantibodies were used to evaluate the sensitivity of the present method compared to the conventional method. The proposed method showed better sensitivity than the current conventional anti-CCP ELISA method.
Collapse
Affiliation(s)
- Ching-Yu Lin
- PhD Program in Medical Biotechnology, College of Medical Science and Technology, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Uyen Thi Nhat Nguyen
- International PhD Program for Cell Therapy and Regeneration Medicine, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Han-Yun Hsieh
- Graduate School of Biomedical & Health Sciences, Hiroshima University, Kausmi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan; Institute of Applied Mechanics, National Taiwan University, 1 Roosevelt Road, Sec. 4, Taipei, 10617, Taiwan
| | - Hidetoshi Tahara
- Graduate School of Biomedical & Health Sciences, Hiroshima University, Kausmi 1-2-3, Minami-ku, Hiroshima, 734-8553, Japan
| | - Yu-Sheng Chang
- Division of Allergy, Immunology and Rheumatology, Shuang Ho Hospital, 291 Zhongzheng Rd., Zhonghe District, New Taipei City, 23561, Taiwan; Division of Allergy, Immunology and Rheumatology, Department of Internal Medicine, School of Medicine, College of Medicine, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Bing-Yu Wang
- Department of Mechanical Engineering, National Chung-Hsing University, 145 Xingda Rd., South Dist., Taichung, 40227, Taiwan
| | - Bing-Chen Gu
- Vida BioTechnology Co., Ltd. Taiwan, 145 Xingda Rd., South Dist., Taichung, 402, Taiwan
| | - Yu-Han Dai
- Vida BioTechnology Co., Ltd. Taiwan, 145 Xingda Rd., South Dist., Taichung, 402, Taiwan
| | - Chia-Che Wu
- Department of Mechanical Engineering, National Chung-Hsing University, 145 Xingda Rd., South Dist., Taichung, 40227, Taiwan
| | - I-Jung Tsai
- PhD Program in Medical Biotechnology, College of Medical Science and Technology, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan
| | - Yu-Jui Fan
- International PhD Program for Cell Therapy and Regeneration Medicine, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan; International PhD Program for Biomedical Engineering, School of Biomedical Engineering, Taipei Medical University, 250 Wuxing St., Taipei, 11031, Taiwan.
| |
Collapse
|
8
|
Lu YJ, Hsieh HY, Kuo WC, Wei PK, Sheen HJ, Tahara H, Chiu TW, Fan YJ. Nanoplasmonic Structure of a Polycarbonate Substrate Integrated with Parallel Microchannels for Label-Free Multiplex Detection. Polymers (Basel) 2021; 13:polym13193294. [PMID: 34641110 PMCID: PMC8512492 DOI: 10.3390/polym13193294] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2021] [Revised: 09/21/2021] [Accepted: 09/24/2021] [Indexed: 01/03/2023] Open
Abstract
In this study, a multiplex detection system was proposed by integrating a localized surface plasmon resonance (LSPR) sensing array and parallel microfluidic channels. The LSPR sensing array was fabricated by nanoimprinting and gold sputter on a polycarbonate (PC) substrate. The polydimethylsiloxane (PDMS) microfluidic channels and PC LSPR sensing array were bound together through (3-aminopropyl)triethoxysilane (APTES) surface treatment and oxygen plasma treatment. The resonant spectrum of the LSPR sensing device was obtained by broadband white-light illumination and polarized wavelength measurements with a spectrometer. The sensitivity of the LSPR sensing device was measured using various ratios of glycerol to water solutions with different refractive indices. Multiplex detection was demonstrated using human immunoglobulin G (IgG), IgA, and IgM. The anti-IgG, anti-IgA, and anti-IgM were separately modified in each sensing region. Various concentrations of human IgG, IgA, and IgM were prepared to prove the concept that the parallel sensing device can be used to detect different targets.
Collapse
Affiliation(s)
- Yi-Jung Lu
- Division of Family and Operative Dentistry, Department of Dentistry, Taipei Medical University Hospital, Taipei 11031, Taiwan;
| | - Han-Yun Hsieh
- Institute of Applied Mechanics, National Taiwan University, Taipei 10617, Taiwan; (H.-Y.H.); (W.-C.K.); (H.-J.S.)
- Department of Cellular and Molecular Biology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8553, Japan;
- School of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
| | - Wen-Chang Kuo
- Institute of Applied Mechanics, National Taiwan University, Taipei 10617, Taiwan; (H.-Y.H.); (W.-C.K.); (H.-J.S.)
| | - Pei-Kuen Wei
- Research Center for Applied Sciences, Academia Sinica, Nankang, Taipei 11529, Taiwan;
| | - Horn-Jiunn Sheen
- Institute of Applied Mechanics, National Taiwan University, Taipei 10617, Taiwan; (H.-Y.H.); (W.-C.K.); (H.-J.S.)
| | - Hidetoshi Tahara
- Department of Cellular and Molecular Biology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8553, Japan;
| | - Te-Wei Chiu
- Department of Materials and Mineral Resources Engineering, National Taipei University of Technology, Taipei 10608, Taiwan
- Correspondence: (T.-W.C.); (Y.-J.F.); Tel.: +886-2-2736-1661 (ext. 7722) (Y.-J.F.)
| | - Yu-Jui Fan
- School of Biomedical Engineering, Taipei Medical University, Taipei 11031, Taiwan
- Correspondence: (T.-W.C.); (Y.-J.F.); Tel.: +886-2-2736-1661 (ext. 7722) (Y.-J.F.)
| |
Collapse
|
9
|
Modern Analytical Techniques for Detection of Bacteria in Surface and Wastewaters. SUSTAINABILITY 2021. [DOI: 10.3390/su13137229] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Contamination of surface waters with pathogens as well as all diseases associated with such events are a significant concern worldwide. In recent decades, there has been a growing interest in developing analytical methods with good performance for the detection of this category of contaminants. The most important analytical methods applied for the determination of bacteria in waters are traditional ones (such as bacterial culturing methods, enzyme-linked immunoassay, polymerase chain reaction, and loop-mediated isothermal amplification) and advanced alternative methods (such as spectrometry, chromatography, capillary electrophoresis, surface-enhanced Raman scattering, and magnetic field-assisted and hyphenated techniques). In addition, optical and electrochemical sensors have gained much attention as essential alternatives for the conventional detection of bacteria. The large number of available methods have been materialized by many publications in this field aimed to ensure the control of water quality in water resources. This study represents a critical synthesis of the literature regarding the latest analytical methods covering comparative aspects of pathogen contamination of water resources. All these aspects are presented as representative examples, focusing on two important bacteria with essential implications on the health of the population, namely Pseudomonas aeruginosa and Escherichia coli.
Collapse
|
10
|
Dutta P, Lu YJ, Hsieh HY, Lee TY, Lee YT, Cheng CM, Fan YJ. Detection of Candida albicans Using a Manufactured Electrochemical Sensor. MICROMACHINES 2021; 12:166. [PMID: 33567542 PMCID: PMC7915424 DOI: 10.3390/mi12020166] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 02/04/2021] [Accepted: 02/04/2021] [Indexed: 01/13/2023]
Abstract
Candida albicans is a commensal fungus that is responsible for a lot of nosocomial infections in immunocompromised people. Cell culture is currently the predominant method for diagnosing candidiasis, but it is time consuming. In this study, we developed a rapid screen procedure by devising a method for detecting C. albicans with the use of electrochemical sensors. Through this experiment, we propose a method for the detection of C. albicans in the system through the use of personal glucose meters. The hemicellulase was used to break down the cell wall of C. albicans to glucose and oligo, which can be detected by a glucose meter. The spiked samples were prepared suspending C. albicans in urine and serum, demonstrating the feasibility of the developed method in a real situation.
Collapse
Affiliation(s)
- Prakhar Dutta
- International Ph.D. Program for Biomedical Engineering, Graduate Institute of Biomedical Materials & Tissue Engineering, School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, 250 Wuxing St., Taipei 11031, Taiwan;
| | - Yi-Jung Lu
- Division of Family and Operative Dentistry, Department of Dentistry, Taipei Medical University Hospital, Taipei 11031, Taiwan;
| | - Han-Yu Hsieh
- Department of Signal Transduction, Research Institute for Microbial Disease, Osaka University, 3-1 Yamada-oka, Suita, Osaka 565-0871, Japan;
| | - Tyng-Yuh Lee
- Institute of Biomedical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan; (T.-Y.L.); (C.-M.C.)
| | - Yi-Tzu Lee
- Department of Emergency Medicine, Taipei Veterans General Hospital, Taipei 11217, Taiwan;
- Faculty of Medicine, School of Medicine, National Yang-Ming University, Taipei 11221, Taiwan
| | - Chao-Min Cheng
- Institute of Biomedical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan; (T.-Y.L.); (C.-M.C.)
| | - Yu-Jui Fan
- International Ph.D. Program for Biomedical Engineering, Graduate Institute of Biomedical Materials & Tissue Engineering, School of Biomedical Engineering, College of Biomedical Engineering, Taipei Medical University, 250 Wuxing St., Taipei 11031, Taiwan;
| |
Collapse
|