1
|
Geng C, Dong Z, Zhang T, Yang Z, Xu Z, Liang S, Ding X. Advances in atmospheric pressure plasma-based optical emission spectrometry for the analysis of heavy metals. Talanta 2024; 270:125634. [PMID: 38215585 DOI: 10.1016/j.talanta.2024.125634] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 01/03/2024] [Accepted: 01/04/2024] [Indexed: 01/14/2024]
Abstract
Over the past decade, miniaturized optical emission spectrometry (OES) systems utilizing atmospheric pressure plasmas (APPs) as radiation sources have exhibited impressive capabilities in trace heavy metal analysis. As the core of the analytical system, APPs sources possess unique properties such as compact size, light weight, low energy requirement, ease of fabrication, and relatively low manufacturing cost. This critical review focuses on recent progress of APP-based OES systems employed for the determination of heavy metals. Influences of technical details including the sample introduction manner, the sampling volume, the sample flow rate, the pH of the solutions on the plasma stability and the intensity of analytical signals are comprehensively discussed. Furthermore, the review emphasizes the analytical challenges faced by these techniques and highlights the opportunities for further development in the field of heavy metal detection.
Collapse
Affiliation(s)
- Chaoqun Geng
- Department of Pharmaceutical Analysis, School of Pharmacy, Qingdao University, Qingdao, 266071, China
| | - Zheng Dong
- Shandong Qingdao Hospital of Integrated Traditional and Western Medicine, Qingdao, 266002, China
| | - Tiantian Zhang
- Department of Pharmaceutical Analysis, School of Pharmacy, Qingdao University, Qingdao, 266071, China
| | - Zhao Yang
- Qingdao Institute for Food and Drug Control, Qingdao 266071, China
| | - Zewen Xu
- Shandong Institute for Food and Drug Control, Jinan 250101, China
| | - Shuai Liang
- Department of Pharmaceutical Chemistry, School of Pharmacy, Qingdao University, Qingdao, 266071, China.
| | - Xuelu Ding
- Department of Pharmaceutical Analysis, School of Pharmacy, Qingdao University, Qingdao, 266071, China.
| |
Collapse
|
2
|
Lu Q, Feng Y, Luo H, Yu J, Kang Y. Enhanced Sensitivity for the Determination of Lithium by Miniaturized Liquid Cathode Glow Discharge (LCGD) Atomic Emission Spectrometry (AES) with the Addition of Surfactants. ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2072856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Quanfang Lu
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, China
- Editorial Department of the University Journal, Northwest Normal University, Lanzhou, China
| | - Yan Feng
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, China
| | - Hui Luo
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, China
| | - Jie Yu
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, China
| | - Yuejing Kang
- College of Chemistry and Chemical Engineering, Northwest Normal University, Lanzhou, China
| |
Collapse
|
3
|
Liu YQ, Ju XJ, Zhou XL, Mu XT, Tian XY, Zhang L, Liu Z, Wang W, Xie R, Chu LY. A novel chemosensor for sensitive and facile detection of strontium ions based on ion-imprinted hydrogels modified with guanosine derivatives. JOURNAL OF HAZARDOUS MATERIALS 2022; 421:126801. [PMID: 34388916 DOI: 10.1016/j.jhazmat.2021.126801] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 07/29/2021] [Accepted: 07/30/2021] [Indexed: 06/13/2023]
Abstract
A novel chemosensor is developed for the sensitive and facile detection of trace strontium ions (Sr2+) based on the ion-imprinted hydrogels. With Sr2+ as the templates, the ion-imprinted hydrogels are synthesized by copolymerizing the ion-responsive units 5'-O-acryloyl-2',3'-O-isopropylidene guanosine (APG) and the thermo-responsive units N-isopropylacrylamide (NIPAM). In the presence of Sr2+, APG units can self-assemble to form planar G-quartets via the complexation with Sr2+, which are introduced into the gel network during polymerization. Then Sr2+ templates can be removed by multiple repeated washing. When re-exposed to Sr2+, the relaxed G-quartets can recognize Sr2+, leading to the weakening of electrostatic repulsion between the four oxygen atoms in the G-quartets and inducing the shrinkage of the hydrogels. In this work, the Sr2+-imprinted chemosensors are designed as the grating systems for detecting trace Sr2+. Based on the array of hydrogel strings synthesized on a nano-scale, the smart grating systems thus constructed can convert and amplify the Sr2+ concentration signals to the easily-measurable optical signals. With the Sr2+-imprinted hydrogel gratings, trace Sr2+ (10-11 M) in an aqueous solution can be detected sensitively. Moreover, the proposed Sr2+-imprinted chemosensors can be integrated with other smart systems for developing various detectors with high performance.
Collapse
Affiliation(s)
- Yu-Qiong Liu
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Xiao-Jie Ju
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, People's Republic of China.
| | - Xing-Long Zhou
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Xiao-Ting Mu
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Xiao-Yu Tian
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Lu Zhang
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Zhuang Liu
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Wei Wang
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Rui Xie
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| | - Liang-Yin Chu
- School of Chemical Engineering, Sichuan University, Chengdu 610065, People's Republic of China; State Key Laboratory of Polymer Materials Engineering, Sichuan University, Chengdu 610065, People's Republic of China
| |
Collapse
|
4
|
Improved solution cathode glow discharge micro-plasma source with a geometrically optimized stainless steel auxiliary cathode for optical emission spectrometry of metal elements. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106883] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
5
|
Pohl P, Jamroz P, Greda K, Gorska M, Dzimitrowicz A, Welna M, Szymczycha-Madeja A. Five years of innovations in development of glow discharges generated in contact with liquids for spectrochemical elemental analysis by optical emission spectrometry. Anal Chim Acta 2021; 1169:338399. [PMID: 34088364 DOI: 10.1016/j.aca.2021.338399] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 03/01/2021] [Accepted: 03/01/2021] [Indexed: 01/13/2023]
Abstract
The newest achievements in the field of glow microdischarges generated in contact with a flowing liquid cathode (FLC) and a flowing liquid anode (FLA), used as the excitation sources for optical emission spectrometry (OES), were summarized herein. The design of recently reported discharge systems was compared and comprehensively discussed. A lot of effort was devoted to evaluate the effect of selected operating parameters, i.e., discharge voltage and current, sample flow rate, sample pH, jet-supporting gas flow rate, and discharge gap, on the microplasma stability and the intensity of measurable analytical signals. Furthermore, the influence of chemical modifiers, i.e., organic acids, alcohols, and surfactants, aimed at improving the sensitivity and reducing matrix effects, was referred to as well. Finally, the analytical performance and the application of these promising excitation sources for the elemental analysis of different-matrix samples were presented.
Collapse
Affiliation(s)
- Pawel Pohl
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland.
| | - Piotr Jamroz
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland
| | - Krzysztof Greda
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland
| | - Monika Gorska
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland
| | - Anna Dzimitrowicz
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland
| | - Maja Welna
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland
| | - Anna Szymczycha-Madeja
- Wroclaw University of Science and Technology, Faculty of Chemistry, Department of Analytical Chemistry and Chemical Metallurgy, Wyspianskiego 27, 50370 Wroclaw, Poland
| |
Collapse
|
6
|
Gorska M, Pohl P. Comparison of the performance of atmospheric pressure glow discharges operated between a flowing liquid cathode and either a pin-type anode or a helium jet anode for the Ga and In determination by the optical emission spectrometry. Talanta 2021; 226:122155. [PMID: 33676703 DOI: 10.1016/j.talanta.2021.122155] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Revised: 01/20/2021] [Accepted: 01/24/2021] [Indexed: 02/06/2023]
Abstract
Novel atmospheric pressure glow discharge (APGD) microplasma systems, sustained between a miniaturized flowing liquid cathode (FLC) and either a pin-type anode or a He nozzle jet were investigated for the determination of Ga and In by the optical emission spectrometry (OES). The most influential working parameters, i.e., solution flow rate, acid concentration, discharge current, and He flow rate, were optimized for both studied systems. Furthermore, the effect of the addition of low molecular weight organic compounds (LMWOCs) into the FLC solution on the signals intensity of Ga and In was investigated. Subsequently, the impact of concomitant ions on the signals intensity of Ga and In was thoroughly studied and it was established that both studied methods are relatively resistant to matrix effects. Under the optimized conditions, the detection limits (DLs, assessed on the basis of the 3σ criterion) of the studied elements were similar for both discharges and ranged between 1.8 and 2.3 μg L-1 for Ga and 0.37-0.40 μg L-1 for In. The received DLs were therefore better than those obtained for other spectrometric methods being premised upon microplasma systems and comparable with those obtained by currently employed large-scale instrumentation. The system with the pin-type anode was successfully applied for the Ga and In determination in four leachates of solders and electronic scrap as well as river water, using external calibration with simple standard solutions. The received results were compared to those obtained from ICP-OES or ICP-MS measurements and their recoveries were fallen within the range of 98-114%, confirming the excellent accuracy and reliability of the developed FLC-APGD-OES method.
Collapse
Affiliation(s)
- Monika Gorska
- Wroclaw University of Science and Technology, Faculty of Chemistry, Division of Analytical Chemistry and Chemical Metallurgy, Wybrzeze Stanislawa Wyspianskiego 27, 50-370, Wroclaw, Poland.
| | - Pawel Pohl
- Wroclaw University of Science and Technology, Faculty of Chemistry, Division of Analytical Chemistry and Chemical Metallurgy, Wybrzeze Stanislawa Wyspianskiego 27, 50-370, Wroclaw, Poland
| |
Collapse
|