1
|
Calero-Cañuelo C, Casado-Carmona FA, Lucena R, Cárdenas S. Sorptive tape-spray tandem mass spectrometry using aluminum foil coated with mixed-mode microparticles. Talanta 2024; 272:125774. [PMID: 38359721 DOI: 10.1016/j.talanta.2024.125774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/06/2024] [Accepted: 02/07/2024] [Indexed: 02/17/2024]
Abstract
Direct mass spectrometry (MS) is an exciting strategy in bioanalysis, enabling rapid decision-making in different scenarios. Its application is usually hindered by matrix effects and the typically low concentration of the target compounds in the biofluids. In this sense, combining a previous sample preparation step minimizes or removes these shortcomings. This article describes sorptive tape-spray tandem mass spectrometry (STS-MS/MS) based on mixed-mode particles as a strategy to combine sample preparation and MS analysis in a single device. The technique uses a sorptive tape (ST) consisting of mixed-mode polymeric microparticles (combining ionic exchange and hydrophobic interactions) coated over aluminum foil in a spatial controlled way. The tapes act as the sorptive phases to isolate the analytes from the sample matrix and substrates for STS-MS/MS. The performance of the technique has been evaluated by developing a method to determine codeine in saliva as proof of concept. The affordability of the STs elements allows the preparation of many individual phases at low cost so that several samples can be extracted simultaneously, thus increasing the sample throughput. The extraction variables were optimized following a multivariate approach. Working under the optimum conditions, the limit of detection was 0.3 μg L-1, while the intraday precision, calculated as relative standard deviation (RSD) at three concentration levels, was better than 9.4 %. The accuracy, expressed as relative recovery, was in the range of 78-98 %. The method was also applied to the analysis of real samples. Despite being a powerful strategy, the direct combination of microextraction to MS is not always affordable in all laboratories. For this reason, the STs were also combined with commercial liquid chromatography-MS working under the direct infusion mode to demonstrate the usefulness of the ST in classical extraction workflows.
Collapse
Affiliation(s)
- Carlos Calero-Cañuelo
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain; FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Illes Balears, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
2
|
Millán-Santiago J, Lucena R, Cárdenas S. Bioinspired composite packed in blunt needles, integrated microextraction and determination of oxycodone and naloxone in saliva by substrate spray mass spectrometry. Anal Chim Acta 2024; 1297:342376. [PMID: 38438230 DOI: 10.1016/j.aca.2024.342376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 02/02/2024] [Accepted: 02/13/2024] [Indexed: 03/06/2024]
Abstract
BACKGROUND Opioids are effective painkillers used for medical purposes. Their prolonged ingestion can provoke some side effects (including overdose or constipation) that are minimized by using opioid antagonists (e.g., naloxone). The rapid determination of opioids and their antagonists in biosamples is essential for an effective medical treatment. The direct combination of sample preparation and mass spectrometry (MS) fits well in this scenario. It can speed up the analysis achieving a good selectivity, which relies on the sample preparation and MS, and sensitivity levels. RESULTS This article presents a novel substrate-spray mass spectrometry interface based on a polydopamine-cotton (PDA-Cel) composite hosted inside the inner diameter of a 14-gauge blunt needle to determine oxycodone and naloxone in saliva samples. The needle is used as a microextraction device and a substrate for mass spectrometric analysis. The lack of sharpness of the 14-gauge (14G) blunt needles challenges the formation of the electrospray (ESI), and a commercial 10 μL pipette tip is proposed as a simple solution to this shortcoming. Under the optimum parameters, the proposed method was validated, obtaining limits of detection lower than 0.6 μg L-1, linear range up to 200 μg L-1, and linearity better than 0.9915. Relative standard deviation (RSD) and relative recoveries (RR) were studied at three different concentration levels (2, 40, and 200 μg L-1). RSD values were better than 20.7 %, and RR ranged from 90 to 114 %. Finally, a positive sample from a patient under medical treatment was analyzed. SIGNIFICANCE AND NOVELTY 14G blunt needles have been demonstrated as effective extraction devices due to their low price (<0.15 € per extraction unit), their better safety (avoiding finger pricking), and their higher hosting capacity (up to 8 mg of sorbent). The conductivity of stainless steel permits their use as electrospray emitters, making their direct combination to MS easier. The large variety of fibrous sorbents makes this approach versatile enough to be adapted to other analytical problems.
Collapse
Affiliation(s)
- Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain.
| |
Collapse
|
3
|
Fattahi N, Heidari R, Ghazanfaripoor B, Masoudipour E, Gharehdaghi J, Nejad KS. Standardization of the analytical procedure based on deep eutectic solvent for the extraction and measurement of tricyclic antidepressants drugs in post-mortem blood samples. J Pharm Biomed Anal 2024; 238:115811. [PMID: 37879218 DOI: 10.1016/j.jpba.2023.115811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/15/2023] [Accepted: 10/20/2023] [Indexed: 10/27/2023]
Abstract
Measuring drugs in post-mortem blood samples is one of the most important challenges in forensic medicine. The development of sensitive analytical techniques for the measurement of drugs in biological samples is of great use in forensic medicine. In this research an easy, safe and environmental friendly vortex-assisted liquid phase microextraction (VA-LPME) based on deep eutectic solvent (DES) followed by high performance liquid chromatography-ultraviolet detector (HPLC-UV) was developed for the extraction, preconcentration and analysis of tricyclic antidepressants drugs (TCAs) in post-mortem blood samples. DES synthesized from thymol as hydrogen bond acceptor (HBA) and ethylene glycol (EG) as hydrogen bond donor (HBD) with a molar ratio of 2:1 was used as an extractant. After adding DES to the sample solution, the resulting mixture was vortexed in order to increase the contact surface and increase the extraction efficiency. Next, phase separation was done using centrifugation. Some effective parameters on the extraction were studied and optimized. Under the optimum conditions, intra- and inter-day %RSDs of the method based on 7 replicate measurements of 100 μg L-1 of TCAs in blood samples were in the range of 2.4-5.1 and 3.7-6.8 %, respectively. The analytical performance of the method showed linearity over the concentration of 3-500 μg L-1 with the detection limits ranging from 1.0-2.0 μg L-1. The trueness of the method was confirmed by spiking different concentrations of TCAs in real blood samples and obtaining relative recoveries in the range of 91.2-108 %.
Collapse
Affiliation(s)
- Nazir Fattahi
- Research Center for Environmental Determinants of Health, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Islamic Republic of Iran.
| | - Rohollah Heidari
- Research Center for Environmental Determinants of Health, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Islamic Republic of Iran
| | - Behzad Ghazanfaripoor
- Legal Medicine Research Center, Legal Medicine Organization, Tehran, Islamic Republic of Iran
| | - Elham Masoudipour
- Legal Medicine Research Center, Legal Medicine Organization, Tehran, Islamic Republic of Iran
| | - Jaber Gharehdaghi
- Legal Medicine Research Center, Legal Medicine Organization, Tehran, Islamic Republic of Iran
| | - Kambiz Soltani Nejad
- Legal Medicine Research Center, Legal Medicine Organization, Tehran, Islamic Republic of Iran
| |
Collapse
|
4
|
Moosavi NS, Yamini Y. Growth of bimetallic Ni-Co MOFs on a skeleton of electrospun PAN nanofibers and coating on a thin film for SPME of amitriptyline and nortriptyline in urine and plasma samples. J Pharm Biomed Anal 2023; 236:115755. [PMID: 37778203 DOI: 10.1016/j.jpba.2023.115755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 09/10/2023] [Accepted: 09/25/2023] [Indexed: 10/03/2023]
Abstract
In this research, composited bimetallic organic framework-polyacrylonitrile (Ni-Co MOFs-PAN) was applied for thin-film solid phase microextraction (TF-SPME) of tricyclic antidepressant (TCA) drugs from biological samples. The separation and quantification of the analytes were accomplished by HPLC-UV. First, seeded nanofibers with organic ligands were electrospun on a sheet of foil. Then, with the uniform in-situ solvothermal growth of Ni-Co MOFs on the skeletal surface of nanofibers, the nanoparticles were successfully attached to the surfaces without effective bonds and produced a thin layer with a high flexibility, large active surface and abundant functional groups for adsorption. The characteristics of the produced nanocomposite were investigated by Fourier-transform infrared spectroscopy, field emission-scanning electron microscopy, X-ray diffraction, energy dispersive X-ray spectroscopy and Brunauer-Emmett-Teller analysis. The stirring rate, pH, ionic strength, adsorption and desorption time along with type and volume of desorption solvents as influential factors on extraction efficiencies of the analytes, were optimized by one variable at a time method. Under optimized conditions, wide linear range for analytes in water and plasma matrices were obtained from 0.2 to 1000.0 μg L-1 and 1.0-1000.0 μg L-1, respectively, with R2 ≥ 0.9925. The limits of detection were in the range of 0.06-0.3 μg L-1 in different media. Good repeatability and reproducibility were attained within intra-day, inter-day and film-to-film RSDs% (n = 3) below 3.3 %, 3.9 % and 4.7 %, respectively. Since desirable relative recoveries were calculated between 91.4 % and 100.4 %. The method can be used for the successful extraction and measurement of amitriptyline and nortriptyline as its metabolite in different sampling time from urine and plasma matrices.
Collapse
Affiliation(s)
- Negar Sabahi Moosavi
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran.
| |
Collapse
|
5
|
Zhang YX, Zhang Y, Bian Y, Liu YJ, Ren A, Zhou Y, Shi D, Feng XS. Benzodiazepines in complex biological matrices: Recent updates on pretreatment and detection methods. J Pharm Anal 2023. [DOI: 10.1016/j.jpha.2023.03.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2023] Open
|
6
|
Locatelli M, Covone S, Rosato E, Bonelli M, Savini F, Furton K, Gazioglu I, D'Ovidio C, Kabir A, Tartaglia A. Analysis of seven selected antidepressant drugs in post–mortem samples using fabric phase sorptive extraction followed by high performance liquid chromatography-photodiode array detection. Forensic Chem 2022. [DOI: 10.1016/j.forc.2022.100460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
7
|
Stelmaszczyk P, Iwan M, Wietecha-Posłuszny R. The direct immersion solid phase microextraction coupled with the LC–MS method for ex vivo determination of selected date-rape drugs in the human blood samples. MONATSHEFTE FUR CHEMIE 2022. [DOI: 10.1007/s00706-022-02962-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
AbstractNowadays, solid phase microextraction is developing rapidly. The use of this extraction technique allowed for the reduction of toxic solvents usage, easy automatization, and integration with other techniques. In this study, the use of DI-SPME/LC–MS to determine selected date-rape drugs (benzodiazepines, ketamine, and cocaine) is presented. The determined values of validation parameters: limits of detection (LOD = 0.6–4.9 ng cm−3), and quantification (LOQ = 25 or 50 ng cm−3), intra-day and inter-day precision (CV = 0.87–10.7% and 4.96–16.1%, respectively), recovery (RE = 94.6–106.7%) and matrix effect (81.7–116.5%) indicated that the tested method could be used to determine the concentration of date-rape drugs in blood samples. The evaluation of the method according to the principles of White Analytical Chemistry showed that the DI-SPME/LC–MS method was characterized by satisfactory analytical quality, greenness, and economical use. The use of this method met the requirements of Green Chemistry. The significant advantages of this method were the quick analytical procedure, partial automation of the extraction stages, high sensitivity, lower sample, and reagent consumption.
Graphical abstract
Collapse
|
8
|
Wachełko O, Szpot P, Tusiewicz K, Nowak K, Chłopaś-Konowałek A, Zawadzki M. An ultra-sensitive UHPLC-QqQ-MS/MS method for determination of 54 benzodiazepines (pharmaceutical drugs, NPS and metabolites) and z-drugs in biological samples. Talanta 2022; 251:123816. [DOI: 10.1016/j.talanta.2022.123816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 07/25/2022] [Accepted: 08/02/2022] [Indexed: 11/28/2022]
|
9
|
Vejar-Vivar C, Millán-Santiago J, Mardones C, Lucena R, Cárdenas S. Polydopamine inner wall-coated hypodermic needle as microextraction device and electrospray emitter for the direct analysis of illicit drugs in oral fluid by ambient mass spectrometry. Talanta 2022; 249:123693. [PMID: 35751921 DOI: 10.1016/j.talanta.2022.123693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/08/2022] [Accepted: 06/13/2022] [Indexed: 10/31/2022]
Abstract
In this article, polydopamine inner wall-coated hypodermic needles (PDA-HNs) are evaluated as both microextraction devices and electrospray ionization (ESI) emitters for determining selected illicit drugs (methamphetamine, cocaine, and methadone) in oral fluid samples. The PDA film, located in the inner wall of the needle, allows the extraction of the analytes at alkaline pH, where their hydrophobic character is promoted. The extracted analytes are finally eluted in a methanol/formic acid mixture that also acts as ESI solution. For this purpose, a dedicated interface based on the connection of a PEEK tube with the needle hub is proposed. This assembly allows delivering the ESI solution by the infusion syringe pump of the mass spectrometer, providing an efficient ESI on the tip of the needle. The double use of the PDA-HNs as microextraction devices and ESI emitters permits the determination of the target analytes with limits of detection and precision (expressed as relative standard deviation) values better than 2.4 μg/L and 17.6%, respectively. The accuracy was evaluated by analyzing independent spiked oral fluid samples, obtaining good results.
Collapse
Affiliation(s)
- Carmina Vejar-Vivar
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain; Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción, Concepción, Casilla 237, Correo 3, Concepción, Chile
| | - Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Claudia Mardones
- Departamento de Análisis Instrumental, Facultad de Farmacia, Universidad de Concepción, Concepción, Casilla 237, Correo 3, Concepción, Chile
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Universitario de Investigación en Química Fina y Nanoquímica IUNAN, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
10
|
Novel Applications of Microextraction Techniques Focused on Biological and Forensic Analyses. SEPARATIONS 2022. [DOI: 10.3390/separations9010018] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
In recent years, major attention has been focused on microextraction procedures that allow high recovery of target analytes, regardless of the complexity of the sample matrices. The most used techniques included liquid-liquid extraction (LLE), solid-phase extraction (SPE), solid-phase microextraction (SPME), dispersive liquid-liquid microextraction (DLLME), microextraction by packed sorbent (MEPS), and fabric-phase sorptive extraction (FPSE). These techniques manifest a rapid development of sample preparation techniques in different fields, such as biological, environmental, food sciences, natural products, forensic medicine, and toxicology. In the biological and forensic fields, where a wide variety of drugs with different chemical properties are analyzed, the sample preparation is required to make the sample suitable for the instrumental analysis, which often includes gas chromatography (GC) and liquid chromatography (LC) coupled with mass detectors or tandem mass detectors (MS/MS). In this review, we have focused our attention on the biological and forensic application of these innovative procedures, highlighting the major advantages and results that have been accomplished in laboratory and clinical practice.
Collapse
|