1
|
Zhang LZ, Shang L, Zhang W, Jia LP, Ma RN, Li XJ, Xue QW, Wang HS. Dual-potential ratiometric electrochemiluminescence based on single emitter and single coreactant for the sensitive detection of carcinoembryonic antigen. Talanta 2024; 274:126023. [PMID: 38583328 DOI: 10.1016/j.talanta.2024.126023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2024] [Revised: 03/12/2024] [Accepted: 03/30/2024] [Indexed: 04/09/2024]
Abstract
Dual-potential ratiometric electrochemiluminescence (ECL) is in favor of resistance to environmental interference. However, two kinds of emitters or coreactants, and a wide scan potential range (>2 V) are mandatory. This work developed a new dual-potential ratiometric ECL sensor for detection of carcinoembryonic antigen (CEA) using single emitter (luminol) and single coreactant (H2O2) with a mild potential range from -0.1 to 0.6 V. Luminol could produce a strong cathodic ECL (Ec) induced by hydroxyl radicals (HO‧) from the reduction of H2O2, and a relatively weak anodic ECL (Ea). After the ferrocene modified CEA aptamer (Apt-Fc) was attached, Fc could promote Ea by catalyzing the oxidation of H2O2, and reduce Ec by consuming HO‧. With the cycling amplification of the exonuclease I, CEA could substantially reduce the amount of Apt-Fc, resulting in the decrease of Ea and the rise of Ec. So, the ratio of Ec to Ea (Ec/Ea) was used as the detection signal, realizing the sensitive determination of CEA from 0.1 pg mL-1 to 10 ng mL-1 with a LOD of 41.85 fg mL-1 (S/N = 3). The developed sensor demonstrated excellent specificity, stability and reproducibility, with satisfactory results in practical detection.
Collapse
Affiliation(s)
- Lin-Zhi Zhang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China.
| | - Lei Shang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China.
| | - Wei Zhang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China
| | - Li-Ping Jia
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China
| | - Rong-Na Ma
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China
| | - Xiao-Jian Li
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China
| | - Qing-Wang Xue
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China
| | - Huai-Sheng Wang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, PR China.
| |
Collapse
|
2
|
Erkal-Aytemur A, Mülazımoğlu İE, Üstündağ Z, Caglayan MO. A novel aptasensor platform for the detection of carcinoembryonic antigen using quartz crystal microbalance. Talanta 2024; 277:126376. [PMID: 38852341 DOI: 10.1016/j.talanta.2024.126376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 05/13/2024] [Accepted: 06/05/2024] [Indexed: 06/11/2024]
Abstract
In this study, a quartz crystal microbalance (QCM) aptasensor for carcinoembryonic antigen (CEA), a well-known biomarker for various cancer types, was reported, utilizing two different aptamers. To achieve this, a nanofilm of 4-mercaptophenyl was electrochemically attached to gold-coated QCM crystal surfaces via the reduction of 4-mercaptobenzenediazonium salt (4 MB-DAT) using cyclic voltammetry. Subsequently, gold nanoparticles (AuNP) were affixed to this structure, and then aptamers (antiCEA1 and antiCEA2) modified with SH-functional ends bound to AuNPs completed the modification. The analytical performance of the CEA sensor was evaluated through simultaneous QCM measurements employing CEA solutions ranging from 0.1 ng/mL to 25 ng/mL. The detection limit (LOD) for CEA was determined to be 102 pg/mL for antiCEA1 and 108 pg/mL for antiCEA2 aptamers. Interday and intraday precision and accuracy tests yielded maximum results of 4.3 and + 3.8, respectively, for both aptasensors, as measured by relative standard deviation (RSD%) and relative error (RE%). The kinetic data of the aptasensors resulted in affinity values (KD) of 0.43 ± 0.14 nM for antiCEA1 and 0.75 ± 0.42 nM for antiCEA2. These values were lower than the reported values of 3.9 nM and 37.8 nM for both aptamers, respectively. The selectivity of the aptasensor was evaluated by measuring the signal changes caused by alpha-fetoprotein (AFP), cancer antigen (CA-125), and vascular endothelial growth factor (VEGF-165) individually and together at a concentration of 500 ng/mL, resulting in a maximum 4.1 % change, which was comparable to precision and accuracy values reported in the literature. After confirming the selectivity of the aptamers, recovery experiments were conducted using spiked commercial serum samples to simulate real samples, and the lowest recovery value obtained was 95.4 %. It was determined that two different aptasensors could be successfully used for the QCM-based detection of CEA in this study.
Collapse
Affiliation(s)
- Aslı Erkal-Aytemur
- Alanya Alaaddin Keykubat University, R.K. Faculty of Engineering, Fundamental Science, Antalya, Turkey
| | | | - Zafer Üstündağ
- Kütahya Dumlupınar University, Faculty of Arts and Science, Department of Chemistry, Kütahya, Turkey
| | - Mustafa Oguzhan Caglayan
- Bilecik Seyh Edebali University, Faculty of Engineering, Department of Bioengineering, Bilecik, Turkey.
| |
Collapse
|
3
|
Wu Q, Tian L, Shan X, Yang S, Li H, Li C, Lu J. Enhancing electrochemiluminescence by modifying Fe 3CuO 4 and CdS@ZnS: A novel ECL sensor for highly sensitive detection of permethrin. Talanta 2024; 268:125393. [PMID: 37944418 DOI: 10.1016/j.talanta.2023.125393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 10/31/2023] [Accepted: 11/03/2023] [Indexed: 11/12/2023]
Abstract
A novel electrochemiluminescence (ECL) sensor was constructed for the detection of permethrin by modifying Fe3CuO4-Ru(bpy)32+ and GO-CdS@ZnS on the electrode. Fe3CuO4 was used as a carrier to adsorb more luminous reagent Ru(bpy)32+ to promote luminescence. Meanwhile, it also can be used as a co-reaction promoter to amplify the initial signal of Ru(bpy)32+-tri-n-propylamine (TPrA) system. When GO-CdS@ZnS was introduced into this system, the ECL signal was further enhanced. The porous nature of graphene oxide (GO) was utilized to load a large amount of CdS@ZnS, in which CdS@ZnS acted as the co-reactant to amplify the ECL signal. The amount of permethrin (PMT) increased and the ECL signal decreased. Under the optimum conditions, the ECL response was linearly related to the logarithm of PMT concentration. The developed ECL sensor allowed for sensitive determination of PMT and exhibited a wide linear range from 1.0 × 10-11 mol L-1 to 1.0 × 10-7 mol L-1. The limit of detection was 3.3 × 10-12 mol L-1 (S/N = 3). It can be used for the detection of PMT in vegetable samples.
Collapse
Affiliation(s)
- Qian Wu
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Li Tian
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China.
| | - Xiangyu Shan
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Shuning Yang
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Huiling Li
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Chao Li
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China
| | - Juan Lu
- College of Chemistry, Changchun Normal University, Changchun, 130032, People's Republic of China.
| |
Collapse
|
4
|
Cheng M, Zhang J, Huang T, Qin L, Dong H, Liao F, Fan H. A dual-mode sensor platform with adjustable electrochemiluminescence-fluorescence for selective detection of paraquat pesticide. Food Chem 2024; 430:137030. [PMID: 37523820 DOI: 10.1016/j.foodchem.2023.137030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Revised: 07/03/2023] [Accepted: 07/25/2023] [Indexed: 08/02/2023]
Abstract
This study presents functionalized metal-organic frameworks nanosheets (RuMOFNSs) with strong electrochemiluminescence (ECL) and fluorescence (FL) properties and a novel signal marker-tetraferrocene. Based on the efficient quenching effect of the tetraferrocene on RuMOFNSs, a "signal switch" ECL-FL dual-mode sensor is constructed for sensitive detection of paraquat (PQ). ECL and FL signals are annihilated after adding paraquat-aptamer DNA (PQ-Apt DNA) labeled with tetraferrocene since it is close to RuMOFNSs. PQ is added, and the strong binding and intermolecular interaction between PQ-Apt DNA and PQ induces spatial separation, with tetraferrocene groups far away from RuMOFNSs. At this point, ECL and FL signals are restored. The change in ECL and FL signals realized the quantitative determination of the PQ solution. In addition, the dual-mode sensor exhibits high sensitivity and specificity with detection limits as low as 0.008 ng/mL and 0.059 ng/mL. The proposed sensor is successfully applied to determine PQ, indicating its great application potential in the food industry.
Collapse
Affiliation(s)
- Mengqing Cheng
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China
| | - Jing Zhang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China
| | - Ting Huang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China
| | - Longshua Qin
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China
| | - Huanhuan Dong
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Fusheng Liao
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Hao Fan
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| |
Collapse
|
5
|
Shelash Al-Hawary SI, Malviya J, Althomali RH, Almalki SG, Kim K, Romero-Parra RM, Fahad Ahmad A, Sanaan Jabbar H, Vaseem Akram S, Hussien Radie A. Emerging Insights into the Use of Advanced Nanomaterials for the Electrochemiluminescence Biosensor of Pesticide Residues in Plant-Derived Foodstuff. Crit Rev Anal Chem 2023:1-18. [PMID: 37728973 DOI: 10.1080/10408347.2023.2258971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
Pesticides have an important role in rising the overall productivity and yield of agricultural foods by eliminating and controlling insects, pests, fungi, and various plant-related illnesses. However, the overuse of pesticides has caused pesticide pollution of water bodies and food products, along with disruption of environmental and ecological systems. In this regard, developing low-cost, simple, and rapid-detecting approaches for the accurate, rapid, efficient, and on-site screening of pesticide residues is an ongoing challenge. Electrochemiluminescence (ECL) possesses the benefits of great sensitivity, the capability to resolve several analytes using different emission wavelengths or redox potentials, and excellent control over the light radiation in time and space, making it a powerful strategy for sensing various pesticides. Cost-effective and simple ECL systems allow sensitive, selective, and accurate quantification of pesticides in agricultural fields. Particularly, the development and progress of nanomaterials, aptamer/antibody recognition, electric/photo-sensing, and their integration with electrochemiluminescence sensing technology has presented the hopeful potential in reporting the residual amounts of pesticides. Current trends in the application of nanoparticles are debated, with an emphasis on sensor substrates using aptamer, antibodies, enzymes, and molecularly imprinted polymers (MIPs). Different strategies are enclosed in labeled and label-free sensing along with luminescence determination approaches (signal-off, signal-on, and signal-switch modes). Finally, the recent challenges and upcoming prospects in this ground are also put forward.
Collapse
Affiliation(s)
| | - Jitendra Malviya
- Department of Life Sciences & Biological Sciences, IES University, Bhopal, India
| | - Raed H Althomali
- Department of Chemistry, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Sami G Almalki
- Department of Medical Laboratory Sciences, College of Applied Medical Sciences, Majmaah University, Majmaah, Saudi Arabia
| | - Kibum Kim
- Department of Human-Computer Interaction, Hanyang University, Seoul, South Korea
| | | | - Ahmad Fahad Ahmad
- Department of Radiology, College of Health and Medical Technology, Al-Ayen University, Thi-Qar, Iraq
| | - Hijran Sanaan Jabbar
- Department of Chemistry, College of Science, Salahaddin University-Erbil, Erbil, Iraq
| | - Shaik Vaseem Akram
- Division of Research & Innovation, Uttaranchal Institute of Technology, Uttaranchal University, Dehradun, India
| | | |
Collapse
|
6
|
Malik S, Singh J, Goyat R, Saharan Y, Chaudhry V, Umar A, Ibrahim AA, Akbar S, Ameen S, Baskoutas S. Nanomaterials-based biosensor and their applications: A review. Heliyon 2023; 9:e19929. [PMID: 37809900 PMCID: PMC10559358 DOI: 10.1016/j.heliyon.2023.e19929] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 10/10/2023] Open
Abstract
A sensor can be called ideal or perfect if it is enriched with certain characteristics viz., superior detections range, high sensitivity, selectivity, resolution, reproducibility, repeatability, and response time with good flow. Recently, biosensors made of nanoparticles (NPs) have gained very high popularity due to their excellent applications in nearly all the fields of science and technology. The use of NPs in the biosensor is usually done to fill the gap between the converter and the bioreceptor, which is at the nanoscale. Simultaneously the uses of NPs and electrochemical techniques have led to the emergence of biosensors with high sensitivity and decomposition power. This review summarizes the development of biosensors made of NPssuch as noble metal NPs and metal oxide NPs, nanowires (NWs), nanorods (NRs), carbon nanotubes (CNTs), quantum dots (QDs), and dendrimers and their recent advancement in biosensing technology with the expansion of nanotechnology.
Collapse
Affiliation(s)
- Sumit Malik
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India
| | - Joginder Singh
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India
| | - Rohit Goyat
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India
| | - Yajvinder Saharan
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India
| | - Vivek Chaudhry
- Department of Chemistry, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, 133203, Haryana, India
| | - Ahmad Umar
- Department of Chemistry, Faculty of Science and Arts, and Promising Centre for Sensors and Electronic Devices (PCSED)Najran University, Najran, 11001, Kingdom of Saudi Arabia
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH, 43210, USA
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Ahmed A. Ibrahim
- Department of Chemistry, Faculty of Science and Arts, and Promising Centre for Sensors and Electronic Devices (PCSED)Najran University, Najran, 11001, Kingdom of Saudi Arabia
| | - Sheikh Akbar
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH, 43210, USA
| | - Sadia Ameen
- Advanced Materials and Devices Laboratory, Department of Bio-Convergence Science, Advanced Science Campus, Jeonbuk National University, 56212, Jeonju, Republic of Korea
| | - Sotirios Baskoutas
- Department of Materials Science, University of Patras, 26500, Patras, Greece
| |
Collapse
|
7
|
Shi Y, Li T, Zhao L, Liu Y, Ding K, Li D, He P, Jiang D, Liu J, Zhou H. Ultrathin MXene nanosheet-based TiO2/CdS heterostructure as a photoelectrochemical sensor for detection of CEA in human serum samples. Biosens Bioelectron 2023; 230:115287. [PMID: 37012191 DOI: 10.1016/j.bios.2023.115287] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/18/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023]
Abstract
To develop highly accurate and ultrasensitive strategies is of great importance for the clinical measurement, in particular, the detection of cancer biomarkers. Herein, we synthesized an ultrasensitive TiO2/MXene/CdS QDs (TiO2/MX/CdS) heterostructure as a photoelectrochemical immunosensor, which favors energy levels matching and fast electron transfer from CdS to TiO2 in the help of ultrathin MXene nanosheet. Dramatic photocurrent quenching can be observed upon incubation of the TiO2/MX/CdS electrode by Cu2+ solution from 96-well microplate, which caused by the formation of CuS and subsequent CuxS (x = 1, 2), reducing the absorption of light and boosting the electron-hole recombination upon irradiation. As a result, the as-prepared biosensor demonstrates a linearly increased photocurrent quenching percentage (Q%) value with CEA concentration ranging from 1 fg/mL to 10 ng/mL, as well as a low detection limit of 0.24 fg/mL. Benefit from its excellent stability, high selectivity and good reproducibility of as-prepared PEC immunosensor, we believe that this proposed strategy might provide new opportunities for clinical diagnosis of CEA and other tumor markers.
Collapse
|
8
|
Xie Y, Guan Z, Ma H, Wang P, Xi S. Ultrasensitive detection of carcinoembryonic antigen based on exonuclease Ⅲ-assisted recycling and hybridization chain reaction strategies. INT J ELECTROCHEM SC 2023. [DOI: 10.1016/j.ijoes.2023.100127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
|
9
|
Khan S, Cho WC, Sepahvand A, Haji Hosseinali S, Hussain A, Nejadi Babadaei MM, Sharifi M, Falahati M, Jaragh-Alhadad LA, Ten Hagen TLM, Li X. Electrochemical aptasensor based on the engineered core-shell MOF nanostructures for the detection of tumor antigens. J Nanobiotechnology 2023; 21:136. [PMID: 37101280 PMCID: PMC10131368 DOI: 10.1186/s12951-023-01884-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2022] [Accepted: 04/06/2023] [Indexed: 04/28/2023] Open
Abstract
It is essential to develop ultrasensitive biosensors for cancer detection and treatment monitoring. In the development of sensing platforms, metal-organic frameworks (MOFs) have received considerable attention as potential porous crystalline nanostructures. Core-shell MOF nanoparticles (NPs) have shown different diversities, complexities, and biological functionalities, as well as significant electrochemical (EC) properties and potential bio-affinity to aptamers. As a result, the developed core-shell MOF-based aptasensors serve as highly sensitive platforms for sensing cancer biomarkers with an extremely low limit of detection (LOD). This paper aimed to provide an overview of different strategies for improving selectivity, sensitivity, and signal strength of MOF nanostructures. Then, aptamers and aptamers-modified core-shell MOFs were reviewed to address their functionalization and application in biosensing platforms. Additionally, the application of core-shell MOF-assisted EC aptasensors for detection of several tumor antigens such as prostate-specific antigen (PSA), carbohydrate antigen 15-3 (CA15-3), carcinoembryonic antigen (CEA), human epidermal growth factor receptor-2 (HER2), cancer antigen 125 (CA-125), cytokeratin 19 fragment (CYFRA21-1), and other tumor markers were discussed. In conclusion, the present article reviews the advancement of potential biosensing platforms toward the detection of specific cancer biomarkers through the development of core-shell MOFs-based EC aptasensors.
Collapse
Affiliation(s)
- Suliman Khan
- Medical Research Center, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China
- Department of Medical Lab Technology, The University of Haripur, Haripur, Pakistan
| | - William C Cho
- Department of Clinical Oncology, Queen Elizabeth Hospital, Kowloon, Hong Kong, China
| | - Afrooz Sepahvand
- Department of Cellular and Molecular Biology, Faculty of Advanced Science and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Sara Haji Hosseinali
- Department of Genetics, Faculty of Advanced Science and Technology, Tehran Medical Sciences, Islamic Azad University, Tehran, Iran
| | - Arif Hussain
- School of Life Sciences, Manipal Academy of Higher Education, Dubai, United Arab Emirates
| | - Mohammad Mahdi Nejadi Babadaei
- Department of Molecular Genetics, Faculty of Biological Science, North Tehran Branch, Islamic Azad University, Tehran, Iran
| | - Majid Sharifi
- Student Research Committee, School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran
- Depatment of Tissue Engineering, School of Medicine, Shahroud University of Medical Sciences, Shahroud, Iran
| | - Mojtaba Falahati
- Precision Medicine in Oncology (PrMiO), Department of Pathology, Erasmus MC Cancer Institute, Erasmus MC, Rotterdam, The Netherlands.
- Nanomedicine Innovation Center Erasmus (NICE), Erasmus MC, Rotterdam, The Netherlands.
| | | | - Timo L M Ten Hagen
- Precision Medicine in Oncology (PrMiO), Department of Pathology, Erasmus MC Cancer Institute, Erasmus MC, Rotterdam, The Netherlands.
- Nanomedicine Innovation Center Erasmus (NICE), Erasmus MC, Rotterdam, The Netherlands.
| | - Xin Li
- Department of Neurology, The Second Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
| |
Collapse
|
10
|
Wang J, Xu X, Zheng L, Guo Q, Nie G. A signal "on-off-on"-type electrochemiluminescence aptamer sensor for detection of sulfadimethoxine based on Ru@Zn-oxalate MOF composites. Mikrochim Acta 2023; 190:131. [PMID: 36912979 DOI: 10.1007/s00604-023-05701-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 02/10/2023] [Indexed: 03/14/2023]
Abstract
An "on-off-on"-type electrochemiluminescence (ECL) aptamer sensor based on Ru@Zn-oxalate metal-organic framework (MOF) composites is constructed for sensitive detection of sulfadimethoxine (SDM). The prepared Ru@Zn-oxalate MOF composites with the three-dimensional structure provide good ECL performance for the "signal-on." The MOF structure with a large surface area enables the material to fix more Ru(bpy)32+. Moreover, the Zn-oxalate MOF with three-dimensional chromophore connectivity provides a medium which can accelerate excited-state energy transfer migration among Ru(bpy)32+ units, and greatly reduces the influence of solvent on chromophore, achieving a high-energy Ru emission efficiency. The aptamer chain modified with ferrocene at the end can hybridize with the capture chain DNA1 fixed on the surface of the modified electrode through base complementary pairing, which can significantly quench the ECL signal of Ru@Zn-oxalate MOF. SDM specifically binds to its aptamer to separate ferrocene from the electrode surface, resulting in a "signal-on" ECL signal. The use of the aptamer chain further improves the selectivity of the sensor. Thus, high-sensitivity detection of SDM specificity is realized through the specific affinity between SDM and its aptamer. This proposed ECL aptamer sensor has good analytical performance for SDM with low detection limit (27.3 fM) and wide detection range (100 fM-500 nM). The sensor also shows excellent stability, selectivity, and reproducibility, which proved its analytical performance. The relative standard deviation (RSD) of SDM detected by the sensor is between 2.39 and 5.32%, and the recovery is in the range 97.23 to 107.5%. The sensor shows satisfactory results in the analysis of actual seawater samples, which is expected to play a role in the exploration of marine environmental pollution.
Collapse
Affiliation(s)
- Jingjing Wang
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, People's Republic of China
| | - Xuejiao Xu
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, People's Republic of China
| | - Lu Zheng
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, People's Republic of China
| | - Qingfu Guo
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, People's Republic of China
| | - Guangming Nie
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao, 266042, People's Republic of China.
| |
Collapse
|
11
|
Highly efficient synthesis of CeO2@g-C3N4 double-shelled hollow spheres for ultrasensitive self-enhanced electrochemiluminescence biosensors. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/07/2023]
|
12
|
Akbari Nakhjavani S, Khalilzadeh B, Afsharan H, Hosseini N, Ghahremani MH, Carrara S, Tasoglu S, Omidi Y. Electrochemiluminescent immunosensor for detection of carcinoembryonic antigen using luminol-coated silver nanoparticles. Mikrochim Acta 2023; 190:77. [PMID: 36715890 DOI: 10.1007/s00604-023-05656-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 01/09/2023] [Indexed: 01/31/2023]
Abstract
Recently, electrochemiluminescent (ECL) immunosensors have received much attention in the field of biomarker detection. Here, a highly enhanced ECL immunosensing platform was designed for ultrasensitive detection of carcinoembryonic antigen (CEA). The surface of the glassy carbon electrode was enhanced by applying functional nanostructures such as thiolated graphene oxide (S-GO) and streptavidin-coated gold nanoparticles (SA-AuNPs). The selectivity and sensitivity of the designed immunosensor were improved by entrapping CEA biomolecules using a sandwich approach. Luminol/silver nanoparticles (Lu-SNPs) were applied as the main core of the signaling probe, which were then coated with streptavidin to provide overloading of the secondary antibody. The highly ECL signal enhancement was obtained due to the presence of horseradish peroxidase (HRP) in the signaling probe, in which the presence of H2O2 further amplified the intensity of the signals. The engineered immunosensor presented excellent sensitivity for CEA detection, with limit of detection (LOD) and linear detection range (LDR) values of 58 fg mL-1 and 0.1 pg mL-1 to 5 pg mL-1 (R2 = 0.9944), respectively. Besides its sensitivity, the fabricated ECL immunosensor presented outstanding selectivity for the detection of CEA in the presence of various similar agents. Additionally, the developed immunosensor showed an appropriate repeatability (RSD 3.8%) and proper stability (2 weeks). Having indicated a robust performance in the real human serum with stated LOD and LDR, the engineered immunosensor can be considered for the detection and monitoring of CEA in the clinic.
Collapse
Affiliation(s)
- Sattar Akbari Nakhjavani
- Mechanical Engineering Department, School of Engineering, Koç University, Istanbul, Turkey, 34450.
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran.
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul, Turkey, 34450.
| | - Balal Khalilzadeh
- Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Hadi Afsharan
- Optical+Biomedical Engineering Laboratory, Department of Electrical, Electronic and Computer Engineering, University of Western Australia, Perth, WA, 6009, Australia
| | - Nashmin Hosseini
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Department of Pharmaceutics, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Hossein Ghahremani
- Department of Molecular Medicine, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
- Faculty of Pharmacy, Department of Pharmacology-Toxicology, Tehran University of Medical Sciences, Tehran, Iran
| | - Sandro Carrara
- Integrated Circuit Laboratory, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Savas Tasoglu
- Mechanical Engineering Department, School of Engineering, Koç University, Istanbul, Turkey, 34450.
- Koç University Translational Medicine Research Center (KUTTAM), Koç University, Istanbul, Turkey, 34450.
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA.
| |
Collapse
|
13
|
Wang X, Zhu R, Wang X, Liu F, Gao Y, Guan R, Chen Y. Flexible and washable CDs@Eu-MOFs/PVDF Multifunctional thin films as highly selective sensing for nitrobenzene and 4-Nitrophenol. INORG CHEM COMMUN 2023. [DOI: 10.1016/j.inoche.2023.110423] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
14
|
Yang Q, Huang X, Gao B, Gao L, Yu F, Wang F. Advances in electrochemiluminescence for single-cell analysis. Analyst 2022; 148:9-25. [PMID: 36475529 DOI: 10.1039/d2an01159j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Recent years have witnessed the emergence of innovative analytical methods with high sensitivity and spatiotemporal resolution that allowed qualitative and quantitative analysis to be carried out at single-cell and subcellular levels. Electrochemiluminescence (ECL) is a unique chemiluminescence of high-energy electron transfer triggered by electrical excitation. The ingenious combination of electrochemistry and chemiluminescence results in the distinct advantages of high sensitivity, a wide dynamic range and good reproducibility. Specifically, single-cell ECL (SCECL) analysis with excellent spatiotemporal resolution has emerged as a promising toolbox in bioanalysis for revealing individual cells' heterogeneity and stochastic processes. This review focuses on advances in SCECL analysis and bioimaging. The history and recent advances in ECL probes and strategies for system design are briefly reviewed. Subsequently, the latest advances in representative SCECL analysis techniques for bioassays, bioimaging and therapeutics are also highlighted. Then, the current challenges and future perspectives are discussed.
Collapse
Affiliation(s)
- Qian Yang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China. .,Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, China.
| | - Xiaoyu Huang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Beibei Gao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Lu Gao
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| | - Feng Yu
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi 832003, China.
| | - Fu Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.
| |
Collapse
|
15
|
Pu J, Tong P, Meng Y, Li J. Development of a molecularly imprinted electrochemiluminescence sensor based on bifunctional bilayer structured ZIF-8-based magnetic particles for dopamine sensing. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1016/j.cjac.2022.100226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
16
|
Kurup C, Mohd-Naim NF, Keasberry NA, Zakaria SNA, Bansal V, Ahmed MU. Label-Free Electrochemiluminescence Nano-aptasensor for the Ultrasensitive Detection of ApoA1 in Human Serum. ACS OMEGA 2022; 7:38709-38716. [PMID: 36340071 PMCID: PMC9631400 DOI: 10.1021/acsomega.2c04300] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 09/06/2022] [Indexed: 05/11/2023]
Abstract
A molybdenum sulfide/zirconium oxide/Nafion (MoS2/ZrO2/Naf) based electrochemiluminescence (ECL) aptasensor for the selective and ultrasensitive detection of ApoA1 is proposed, with Ru(bpy)3 2+ as the luminophore. The chitosan (CS) modification on the nanocomposite layer allowed glutaraldehyde (GLUT) cross-linking, resulting in the immobilization of ApoA1 aptamers. Scanning electron microscopy, tunneling electron microscopy, and energy dispersive X-ray spectroscopy were used to characterize the nanocomposite, while electrochemiluminescence (ECL), cyclic voltammetry, and electrochemical impedance spectroscopy were used to analyze the aptasensor assembly. The nanocomposite was used as an electrode modifier, which increased the intensity of the ECL signal. Due to the anionic environment produced on the sensor surface following the specific interaction of the ApoA1 biomarker with the sensor, more Ru(bpy)3 2+ were able to be electrostatically attached to the aptamer-ApoA1 complex, resulting in enhanced ECL signal. The ECL aptasensor demonstrated outstanding sensitivity for ApoA1 under optimal experimental conditions, with a detection limit of 53 fg/mL and a wide linear dynamic range of 0.1-1000 pg/mL. The potential practical applicability of this aptasensor was validated by analyzing ApoA1 in human serum samples, with recovery rates of 94-108% (n = 3). The proposed assay was found to be substantially better compared to the commercially available enzyme-linked immunosorbent assay method, as reflected from over 1500 times improvement in the detection limit for ApoA1.
Collapse
Affiliation(s)
- Chitra
P. Kurup
- Biosensors
and Nanobiotechnology Laboratory, Integrated Science Building, Faculty
of Science, Universiti Brunei Darussalam, Jalan Tungku Link, GadongBE 1410, Brunei Darussalam
| | - Noor F. Mohd-Naim
- Biosensors
and Nanobiotechnology Laboratory, Integrated Science Building, Faculty
of Science, Universiti Brunei Darussalam, Jalan Tungku Link, GadongBE 1410, Brunei Darussalam
- PAPRSB
Institute of Health Sciences, Universiti
Brunei Darussalam, Jalan Tungku Link, GadongBE 1410, Brunei Darussalam
| | - Natasha A. Keasberry
- Biosensors
and Nanobiotechnology Laboratory, Integrated Science Building, Faculty
of Science, Universiti Brunei Darussalam, Jalan Tungku Link, GadongBE 1410, Brunei Darussalam
| | - Siti N. A. Zakaria
- Biosensors
and Nanobiotechnology Laboratory, Integrated Science Building, Faculty
of Science, Universiti Brunei Darussalam, Jalan Tungku Link, GadongBE 1410, Brunei Darussalam
| | - Vipul Bansal
- Ian
Potter NanoBioSensing Facility, NanoBiotechnology Research Laboratory
(NBRL), School of Science, RMIT University, GPO Box 2476, Melbourne, Victoria3000, Australia
| | - Minhaz U. Ahmed
- Biosensors
and Nanobiotechnology Laboratory, Integrated Science Building, Faculty
of Science, Universiti Brunei Darussalam, Jalan Tungku Link, GadongBE 1410, Brunei Darussalam
- ;
| |
Collapse
|
17
|
Padmakumari Kurup C, Abdullah Lim S, Ahmed MU. Nanomaterials as signal amplification elements in aptamer-based electrochemiluminescent biosensors. Bioelectrochemistry 2022; 147:108170. [DOI: 10.1016/j.bioelechem.2022.108170] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 05/18/2022] [Accepted: 05/19/2022] [Indexed: 02/05/2023]
|
18
|
Dessale M, Mengistu G, Mengist HM. Nanotechnology: A Promising Approach for Cancer Diagnosis, Therapeutics and Theragnosis. Int J Nanomedicine 2022; 17:3735-3749. [PMID: 36051353 PMCID: PMC9427008 DOI: 10.2147/ijn.s378074] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 08/22/2022] [Indexed: 01/10/2023] Open
Abstract
Cancer remains the most devastating disease and the major cause of mortality worldwide. Although early diagnosis and treatment are the key approach in fighting against cancer, the available conventional diagnostic and therapeutic methods are not efficient. Besides, ineffective cancer cell selectivity and toxicity of traditional chemotherapy remain the most significant challenge. These limitations entail the need for the development of both safe and effective cancer diagnosis and treatment options. Due to its robust application, nanotechnology could be a promising method for in-vivo imaging and detection of cancer cells and cancer biomarkers. Nanotechnology could provide a quick, safe, cost-effective, and efficient method for cancer management. It also provides simultaneous diagnosis and treatment of cancer using nano-theragnostic particles that facilitate early detection and selective destruction of cancer cells. Updated and recent discussions are important for selecting the best cancer diagnosis, treatment, and management options, and new insights on designing effective protocols are utmost important. This review discusses the application of nanotechnology in cancer diagnosis, therapeutics, and theragnosis and provides future perspectives in the field.
Collapse
Affiliation(s)
- Mesfin Dessale
- Department of Medical Laboratory Sciences, Debre Markos University, Debre Markos, Amhara, Ethiopia
| | - Getachew Mengistu
- Department of Medical Laboratory Sciences, Debre Markos University, Debre Markos, Amhara, Ethiopia
| | | |
Collapse
|
19
|
Ding Y, Hu Z, Zhao Y, Shi C, Zhang S, Zhang Z. Self-assembled nanoplatforms with ZIF-8 as a framework for FRET-based glutathione sensing in biological samples. Analyst 2022; 147:5775-5784. [DOI: 10.1039/d2an01544g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
A nanoprobe was constructed by embedding QDs and a rhodamine B derivative (RBD) into ZIF-8. Then, the ultraviolet absorption of RBD that reacted with glutathione can overlap with the emission spectrum of the QDs, causing FRET-based glutathione sensing.
Collapse
Affiliation(s)
- Yujie Ding
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, P. R. China
| | - Zhongfei Hu
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, P. R. China
| | - Yiming Zhao
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, P. R. China
| | - Cai Shi
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, P. R. China
| | - Shijie Zhang
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, P. R. China
| | - Zongrui Zhang
- School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, Anhui 241000, P. R. China
| |
Collapse
|
20
|
Torul H, Çalık Kayiş E, Boyaci IH, Tamer U. An ECL sensor combined with a paper electrode for the determination of phenylalanine. Analyst 2022; 147:4866-4875. [DOI: 10.1039/d2an01340a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2023]
Abstract
An electrochemiluminescence (ECL) sensor combined with a paper electrode was developed for the detection of phenylalanine (l-Phe) in blood samples.
Collapse
Affiliation(s)
- Hilal Torul
- Faculty of Pharmacy, Department of Analytical Chemistry, Gazi University, 06330 Ankara, Turkey
| | - Elif Çalık Kayiş
- Faculty of Pharmacy, Department of Analytical Chemistry, Gazi University, 06330 Ankara, Turkey
| | - I. Hakki Boyaci
- Department of Food Engineering, Hacettepe University, Beytepe, 06512 Ankara, Turkey
| | - Ugur Tamer
- Faculty of Pharmacy, Department of Analytical Chemistry, Gazi University, 06330 Ankara, Turkey
| |
Collapse
|
21
|
Shang L, Zhao XH, Zhang W, Jia LP, Ma RN, Xue QW, Wang HS, Guo AX, Si L. Graphene-PtPd nanocomposite for low-potential-driven electrochemiluminescent determination of carcinoembryonic antigen using Ru(bpy) 32. Mikrochim Acta 2021; 189:17. [PMID: 34873664 DOI: 10.1007/s00604-021-05120-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 11/29/2021] [Indexed: 10/19/2022]
Abstract
As well known, the electrochemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)32+) heavily relies on highly positive or negative triggered voltage, prejudicing the detection toward the bio-molecules. In this work, Ru(bpy)32+ could generate enhanced and stable ECL at a low potential of 0.05 V (vs. Ag/AgCl) on graphene-PtPd hybrid, attributing to its excellent electrocatalysis from the synergistic effect between Pt and Pd. The obtained low-potential-driven ECL could be quenched by MoS2 nanoflowers. Based on the quenching effect, a sandwich "signal-off" ECL immunosensor was fabricated to sensitively detect carcinoembryonic antigen (CEA). A linear calibration curve from 1 fg mL-1 to 1 ng mL-1 was obtained along with a low detection limit of 0.54 fg mL-1 (S/N = 3) under optimal conditions. The sensor showed satisfactory specificity, stability, and reproducibility and was successfully applied to determine CEA in actual samples. The recoveries ranged from 98.80 to 100.23%, and the relative standard deviation (RSD) was lower than 5%. Above all, this work explored new materials in low-potential-driven ECL system and provided a reliable sensing strategy for clinical applications.
Collapse
Affiliation(s)
- Lei Shang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China.
| | - Xiao-Hong Zhao
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China
| | - Wei Zhang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China
| | - Li-Ping Jia
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China
| | - Rong-Na Ma
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China
| | - Qing-Wang Xue
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China
| | - Huai-Sheng Wang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong, 252059, People's Republic of China.
| | - Ai-Xiang Guo
- Liaocheng People's Hospital, Liaocheng, 252002, Shandong, China
| | - Lei Si
- Liaocheng People's Hospital, Liaocheng, 252002, Shandong, China
| |
Collapse
|