1
|
Hu H, Cui H, Yin X, Fan Q, Shuai H, Zhang J, Liao F, Xiong W, Jiang H, Fan H, Liu W, Wei G. Dual-mode fluorescence and electrochemiluminescence sensors based on Ru-MOF nanosheets for sensitive detection of apoE genes. J Mater Chem B 2024; 12:701-709. [PMID: 38131524 DOI: 10.1039/d3tb01934a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
A fluorescence-electrochemiluminescence (FL-ECL) dual-mode sensor for apoE gene detection has been developed, leveraging the unique properties of ruthenium metal organic framework nanosheets (RuMOFNSs). The system utilizes the quenching effect of the Ru(bpy)32+ ECL signal by ferrocene, leading to the synthesis of a multi-electron electrical signal marker, bisferrocene. By immobilizing the P-DNA on RuMOFNSs, bisferrocene quenches both FL and ECL signals. The addition of T-DNA and the consequent formation of double-stranded DNA enable the ExoIII enzyme to excise the bisferrocene fragment, restoring the signals. The sensor demonstrates wide detection linear ranges (1 fM to 1 nM for FL and 0.01 fM to 10 pM for ECL) and remarkable sensitivity (0.048 fM for FL and 0.016 fM for ECL). The dual-mode design offers enhanced reliability through a self-correction feature, reducing false positives. Compared to single-mode sensors, the dual-mode sensor shows significant advantages. Real-world testing confirms the sensor's capacity for robust detection in actual samples, underscoring its promising application in early disease diagnosis. This innovative approach opens up avenues for multi-signal response sensors, offering significant potential for diagnostic technologies.
Collapse
Affiliation(s)
- Huiting Hu
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Hanfeng Cui
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Xia Yin
- JiangXi Province Hospital of Integrated Chinese and Western Medicine, Nan Chang, JiangXi 330004, China
| | - Qiqi Fan
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Hai Shuai
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Jing Zhang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Fusheng Liao
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Wei Xiong
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Hedong Jiang
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Hao Fan
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Wenming Liu
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| | - Guobing Wei
- JiangXi University of Chinese Medicine, Nan Chang, JiangXi 330004, China.
| |
Collapse
|
2
|
Rational design of an allosteric G-quadruplex aptamer probe for ultra-sensitive detection of melamine in milk. Int J Biol Macromol 2022; 210:430-438. [PMID: 35500779 DOI: 10.1016/j.ijbiomac.2022.04.198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Revised: 04/25/2022] [Accepted: 04/26/2022] [Indexed: 11/22/2022]
Abstract
Efficient and accurate detection of melamine in dairy products remains a crucial yet challenging task. Herein, an allosterically modulated G-quadruplex-integrated aptamer is rationally designed with thymine-rich recognition termini for melamine binding. The detection process is facile by simply introducing the analyte into the mixture consisting of G-quadruplex aptamer probes, exonuclease III, and thioflavin T (ThT). The detection feasibility is confirmed by the polyacrylamide gel electrophoresis and fluorescence measurement results. This exonuclease III-assisted signal amplifiable approach works well in a linear range from 0.1 nM to 0.1 μM. Moreover, a detection limit as low as 83 pM is easily achieved, which is almost five orders of magnitude smaller than the maximum allowable melamine levels (about 8 μM) defined by many countries all over the world. The whole assay time for each test is no longer than 1 h. Additionally, the scheme is highly specific and satisfactory recovery rates (from 91% to 104%) are readily obtained when challenged with melamine-spiked milk samples. Therefore, the label-free, turn-on, low-cost, and time-efficient method can be used for reliable detection of melamine in an easily manipulated and ultra-sensitive manner, which may find its utilization in the field of food safety, biomedical engineering, and clinical diagnosis.
Collapse
|