1
|
Aslett LD, Calfee MW, Monge M, Abdel-Hady A, Chamberlain T, Baartmans R, Touati A. Evaluation of sponge wipe surface sampling for collection of potential surrogates for non-spore-forming bioterrorism agents. J Appl Microbiol 2024; 135:lxae097. [PMID: 38609348 DOI: 10.1093/jambio/lxae097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Revised: 04/04/2024] [Accepted: 04/11/2024] [Indexed: 04/14/2024]
Abstract
AIM Evaluate the efficacy of sponge wipe sampling at recovering potential bacterial surrogates for Category A and B non-spore-forming bacterial bioterrorism agents from hard, nonporous surfaces. METHODS A literature survey identified seven nonpathogenic bacteria as potential surrogates for selected Category A and B non-spore-forming bacterial agents. Small (2 × 4 cm) and large (35.6 × 35.6 cm) coupons made from either stainless steel, plastic, or glass, were inoculated and utilized to assess persistence and surface sampling efficiency, respectively. Three commercially available premoistened sponge wipes (3M™, Sani-Stick®, and Solar-Cult®) were evaluated. RESULTS Mean recoveries from persistence testing indicated that three microorganisms (Yersinia ruckeri, Escherichia coli, and Serratia marcescens) demonstrated sufficient persistence across all tested material types. Sampling of large inoculated (≥107 CFU per sample) coupons resulted in mean recoveries ranging from 6.6 to 3.4 Log10 CFU per sample. Mean recoveries for the Solar-Cult®, 3M™ sponge wipes, and Sani-Sticks® across all test organisms and all material types were ≥5.7, ≥3.7, and ≥3.4 Log10 CFU per sample, respectively. Mean recoveries for glass, stainless steel, and ABS plastic across all test organisms and all sponge types were ≥3.8, ≥3.7, and ≥3.4 Log10 CFU per sample, respectively. CONCLUSIONS Recovery results suggest that sponge wipe sampling can effectively be used to recover non-spore-forming bacterial cells from hard, nonporous surfaces such as stainless steel, ABS plastic, and glass.
Collapse
Affiliation(s)
- L D Aslett
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, United States
| | - M W Calfee
- Office of Research and Development, US EPA, Research Triangle Park, NC 27711, United States
| | - M Monge
- CSS, Inc., 10301 Democracy Lane, Suite 300, Fairfax, VA 22030, United States
| | - A Abdel-Hady
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, United States
| | - T Chamberlain
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, United States
| | - R Baartmans
- Intellectechs, Inc., 195 S. Rosemont Road, Suite 103, VA Beach, VA 23452, United States
| | - A Touati
- Jacobs Technology, Inc., 600 William Northern Blvd, Tullahoma, TN 37388, United States
| |
Collapse
|
2
|
Julich S, Hotzel H, Gärtner C, Trouchet D, Fawzy El Metwaly Ahmed M, Kemper N, Tomaso H. Evaluation of a microfluidic chip system for preparation of bacterial DNA from swabs, air, and surface water samples. Biologicals 2016; 44:574-580. [PMID: 27520284 PMCID: PMC5119575 DOI: 10.1016/j.biologicals.2016.06.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2015] [Revised: 12/17/2015] [Accepted: 06/29/2016] [Indexed: 11/18/2022] Open
Abstract
The detection of bacterial pathogens from complex sample matrices by PCR requires efficient DNA extraction. In this study, a protocol for extraction and purification of DNA from swabs, air, and water samples using a microfluidic chip system was established. The optimized protocol includes a combination of thermal, chemical and enzymatic lysis followed by chip-based DNA purification using magnetic particles. The procedure was tested using Gram-positive Bacillus thuringiensis Berliner var. kurstaki as a model organism for Bacillus anthracis and the attenuated live vaccine strain of Francisella tularensis subsp. holarctica as Gram-negative bacterium. The detection limits corresponded to 103 genome equivalents per milliliter (GE/ml) for surface water samples spiked with F. tularensis and 102 GE/ml for B. thuringiensis. In air, 10 GE of F. tularensis per 10 L and 1 GE of B. thuringiensis per 10 L were detectable. For swab samples obtained from artificially contaminated surfaces the detection limits were 4 × 103 GE/cm2 for F. tularensis and 4 × 102 GE/cm2 for B. thuringiensis. Suitability of the chip-assisted procedure for DNA preparation of real samples was demonstrated using livestock samples. The presence of thermophilic Campylobacter spp. DNA could be confirmed in air samples collected on pig and broiler farms. A microfluidic chip system for magnetic bead-based DNA preparation was evaluated. Bacterial DNA was recovered from swabs, air, and surface water. A universal protocol was used for Gram-positive and Gram-negative bacteria. 10 GE of F. tularensis and 1 GE of B. thuringiensis per 10 l air were detectable. Thermophilic Campylobacter DNA was detected in air samples of pig and broiler farms.
Collapse
Affiliation(s)
- Sandra Julich
- Friedrich-Loeffler-Institut, Federal Research Institute for Animal Health, Institute of Bacterial Infections and Zoonoses, Naumburger Straße 96a, 07743 Jena, Germany
| | - Helmut Hotzel
- Friedrich-Loeffler-Institut, Federal Research Institute for Animal Health, Institute of Bacterial Infections and Zoonoses, Naumburger Straße 96a, 07743 Jena, Germany
| | - Claudia Gärtner
- microfluidic ChipShop, Stockholmer Straße 20, 07747 Jena, Germany
| | - Daniel Trouchet
- Bertin Technologies, 10 Avenue André Marie Ampére, 78180 Montigny-le-Bretonneux, France
| | - Marwa Fawzy El Metwaly Ahmed
- Mansoura University, Faculty of Veterinary Medicine, Department of Animal Hygiene and Zoonoses, 60 El Gomhoria Street, 35516 Mansoura, Egypt
| | - Nicole Kemper
- University of Veterinary Medicine Hannover, Foundation, Institute of Animal Hygiene, Animal Welfare and Farm Animal Behaviour, Bischofsholer Damm 15, 30173 Hannover, Germany
| | - Herbert Tomaso
- Friedrich-Loeffler-Institut, Federal Research Institute for Animal Health, Institute of Bacterial Infections and Zoonoses, Naumburger Straße 96a, 07743 Jena, Germany.
| |
Collapse
|
3
|
Silvestri EE, Perkins SD, Rice EW, Stone H, Schaefer FW. Review of processing and analytical methods for Francisella tularensis in soil and water. ANN MICROBIOL 2015. [DOI: 10.1007/s13213-015-1144-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
4
|
Hedman J, Knutsson R, Ansell R, Rådström P, Rasmusson B. Pre-PCR processing in bioterrorism preparedness: improved diagnostic capabilities for laboratory response networks. Biosecur Bioterror 2014; 11 Suppl 1:S87-101. [PMID: 23971826 DOI: 10.1089/bsp.2012.0090] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
Diagnostic DNA analysis using polymerase chain reaction (PCR) has become a valuable tool for rapid detection of biothreat agents. However, analysis is often challenging because of the limited size, quality, and purity of the biological target. Pre-PCR processing is an integrated concept in which the issues of analytical limit of detection and simplicity for automation are addressed in all steps leading up to PCR amplification--that is, sampling, sample treatment, and the chemical composition of PCR. The sampling method should maximize target uptake and minimize uptake of extraneous substances that could impair the analysis--so-called PCR inhibitors. In sample treatment, there is a trade-off between yield and purity, as extensive purification leads to DNA loss. A cornerstone of pre-PCR processing is to apply DNA polymerase-buffer systems that are tolerant to specific sample impurities, thereby lowering the need for expensive purification steps and maximizing DNA recovery. Improved awareness among Laboratory Response Networks (LRNs) regarding pre-PCR processing is important, as ineffective sample processing leads to increased cost and possibly false-negative or ambiguous results, hindering the decision-making process in a bioterrorism crisis. This article covers the nature and mechanisms of PCR-inhibitory substances relevant for agroterrorism and bioterrorism preparedness, methods for quality control of PCR reactions, and applications of pre-PCR processing to optimize and simplify the analysis of various biothreat agents. Knowledge about pre-PCR processing will improve diagnostic capabilities of LRNs involved in the response to bioterrorism incidents.
Collapse
Affiliation(s)
- Johannes Hedman
- Johannes Hedman, PhD, is employed as a specialist at the Swedish National Laboratory of Forensic Science (SKL) and holds a research position at Applied Microbiology, Lund University. Rickard Knutsson, PhD, is Director of Security Department, National Veterinary Institute (SVA), Uppsala, Sweden . Ricky Ansell, PhD, is employed as forensic advisor and senior reporting officer at the Swedish National Laboratory of Forensic Science (SKL). Birgitta Rasmusson, PhD, is employed as research director at the Swedish National Laboratory of Forensic Science (SKL) and holds a position as adjunct professor at Applied Microbiology, Lund University. Peter Rådström, PhD, is employed as professor Applied Microbiology, Lund University
| | | | | | | | | |
Collapse
|
5
|
Amoako KK, Janzen TW, Shields MJ, Hahn KR, Thomas MC, Goji N. Rapid detection and identification of Bacillus anthracis in food using pyrosequencing technology. Int J Food Microbiol 2013; 165:319-25. [DOI: 10.1016/j.ijfoodmicro.2013.05.028] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2012] [Revised: 04/23/2013] [Accepted: 05/29/2013] [Indexed: 12/22/2022]
|
6
|
Abstract
The clinical laboratory diagnosis of cutaneous anthrax is generally established by conventional microbiological methods, such as culture and directly straining smears of clinical specimens. However, these methods rely on recovery of viable Bacillus anthracis cells from swabs of cutaneous lesions and often yield negative results. This study developed a rapid protocol for detection of B. anthracis on clinical swabs. Three types of swabs, flocked-nylon, rayon, and polyester, were evaluated by 3 extraction methods, the swab extraction tube system (SETS), sonication, and vortex. Swabs were spiked with virulent B. anthracis cells, and the methods were compared for their efficiency over time by culture and real-time PCR. Viability testing indicated that the SETS yielded greater recovery of B. anthracis from 1-day-old swabs; however, reduced viability was consistent for the 3 extraction methods after 7 days and nonviability was consistent by 28 days. Real-time PCR analysis showed that the PCR amplification was not impacted by time for any swab extraction method and that the SETS method provided the lowest limit of detection. When evaluated using lesion swabs from cutaneous anthrax outbreaks, the SETS yielded culture-negative, PCR-positive results. This study demonstrated that swab extraction methods differ in their efficiency of recovery of viable B. anthracis cells. Furthermore, the results indicated that culture is not reliable for isolation of B. anthracis from swabs at ≥ 7 days. Thus, we recommend the use of the SETS method with subsequent testing by culture and real-time PCR for diagnosis of cutaneous anthrax from clinical swabs of cutaneous lesions.
Collapse
|
7
|
Impact of processing method on recovery of bacteria from wipes used in biological surface sampling. Appl Environ Microbiol 2012; 78:5872-81. [PMID: 22706055 DOI: 10.1128/aem.00873-12] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Environmental sampling for microbiological contaminants is a key component of hygiene monitoring and risk characterization practices utilized across diverse fields of application. However, confidence in surface sampling results, both in the field and in controlled laboratory studies, has been undermined by large variation in sampling performance results. Sources of variation include controlled parameters, such as sampling materials and processing methods, which often differ among studies, as well as random and systematic errors; however, the relative contributions of these factors remain unclear. The objective of this study was to determine the relative impacts of sample processing methods, including extraction solution and physical dissociation method (vortexing and sonication), on recovery of Gram-positive (Bacillus cereus) and Gram-negative (Burkholderia thailandensis and Escherichia coli) bacteria from directly inoculated wipes. This work showed that target organism had the largest impact on extraction efficiency and recovery precision, as measured by traditional colony counts. The physical dissociation method (PDM) had negligible impact, while the effect of the extraction solution was organism dependent. Overall, however, extraction of organisms from wipes using phosphate-buffered saline with 0.04% Tween 80 (PBST) resulted in the highest mean recovery across all three organisms. The results from this study contribute to a better understanding of the factors that influence sampling performance, which is critical to the development of efficient and reliable sampling methodologies relevant to public health and biodefense.
Collapse
|
8
|
Rose HL, Dewey CA, Ely MS, Willoughby SL, Parsons TM, Cox V, Spencer PM, Weller SA. Comparison of eight methods for the extraction of Bacillus atrophaeus spore DNA from eleven common interferents and a common swab. PLoS One 2011; 6:e22668. [PMID: 21818364 PMCID: PMC3144239 DOI: 10.1371/journal.pone.0022668] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2011] [Accepted: 06/28/2011] [Indexed: 11/19/2022] Open
Abstract
Eight DNA extraction products or methods (Applied Biosystems PrepFiler Forensic DNA Extraction Kit; Bio-Rad Instagene Only, Bio-Rad Instagene & Spin Column Purification; EpiCentre MasterPure DNA & RNA Kit; FujiFilm QuickGene Mini80; Idaho Technologies 1-2-3 Q-Flow Kit; MoBio UltraClean Microbial DNA Isolation Kit; Sigma Extract-N-Amp Plant and Seed Kit) were adapted to facilitate extraction of DNA under BSL3 containment conditions. DNA was extracted from 12 common interferents or sample types, spiked with spores of Bacillus atropheaus. Resulting extracts were tested by real-time PCR. No one method was the best, in terms of DNA extraction, across all sample types. Statistical analysis indicated that the PrepFiler method was the best method from six dry powders (baking, biological washing, milk, plain flour, filler and talcum) and one solid (Underarm deodorant), the UltraClean method was the best from four liquids (aftershave, cola, nutrient broth, vinegar), and the MasterPure method was the best from the swab sample type. The best overall method, in terms of DNA extraction, across all sample types evaluated was the UltraClean method.
Collapse
Affiliation(s)
- Helen L. Rose
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Caroline A. Dewey
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Morgan S. Ely
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Sarah L. Willoughby
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Tanya M. Parsons
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Victoria Cox
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Phillippa M. Spencer
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
| | - Simon A. Weller
- Detection Department, Defence Science and Technology Laboratory, Porton Down, Salisbury, United Kingdom
- * E-mail:
| |
Collapse
|
9
|
Dauphin LA, Walker RE, Petersen JM, Bowen MD. Comparative evaluation of automated and manual commercial DNA extraction methods for detection of Francisella tularensis DNA from suspensions and spiked swabs by real-time polymerase chain reaction. Diagn Microbiol Infect Dis 2011; 70:299-306. [PMID: 21546201 DOI: 10.1016/j.diagmicrobio.2011.02.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2010] [Revised: 12/08/2010] [Accepted: 02/28/2011] [Indexed: 01/27/2023]
Abstract
This study evaluated commercial automated and manual DNA extraction methods for the isolation of Francisella tularensis DNA suitable for real-time polymerase chain reaction (PCR) analysis from cell suspensions and spiked cotton, foam, and polyester swabs. Two automated methods, the MagNA Pure Compact and the QIAcube, were compared to 4 manual methods, the IT 1-2-3 DNA sample purification kit, the MasterPure Complete DNA and RNA purification kit, the QIAamp DNA blood mini kit, and the UltraClean Microbial DNA isolation kit. The methods were compared using 6 F. tularensis strains representing the 2 subspecies which cause the majority of reported cases of tularemia in humans. Cell viability testing of the DNA extracts showed that all 6 extraction methods efficiently inactivated F. tularensis at concentrations of ≤10⁶ CFU/mL. Real-time PCR analysis using a multitarget 5' nuclease assay for F. tularensis revealed that the PCR sensitivity was equivalent using DNA extracted by the 2 automated methods and the manual MasterPure and QIAamp methods. These 4 methods resulted in significantly better levels of detection from bacterial suspensions and performed equivalently for spiked swab samples than the remaining 2. This study identifies optimal DNA extraction methods for processing swab specimens for the subsequent detection of F. tularensis DNA using real-time PCR assays. Furthermore, the results provide diagnostic laboratories with the option to select from 2 automated DNA extraction methods as suitable alternatives to manual methods for the isolation of DNA from F. tularensis.
Collapse
Affiliation(s)
- Leslie A Dauphin
- Bioterrorism Rapid Response and Advanced Technology (BRRAT) Laboratory, Laboratory Preparedness and Response Branch (LPRB), Division of Preparedness and Emerging Infections (DPEI), Centers for Disease Control and Prevention (CDC), Atlanta, GA 30333, USA.
| | | | | | | |
Collapse
|