1
|
Al-Asad HM, El Afandy MH, Mohamed HT, Mohamed MH. Hybrid Prosthesis versus Overdenture: Effect of BioHPP Prosthetic Design Rehabilitating Edentulous Mandible. Int J Dent 2023; 2023:4108679. [PMID: 37426766 PMCID: PMC10325880 DOI: 10.1155/2023/4108679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 02/24/2023] [Accepted: 05/29/2023] [Indexed: 07/11/2023] Open
Abstract
Aim To compare the BioHPP (biocompatible high-performance polymer) as a substructure for the hybrid prosthesis versus the BioHPP bar supporting and retaining implant overdenture by radiographic evaluation to identify bone height alteration around the implants and to evaluate satisfaction based on visual analoge scale questionnaire. Materials and Methods Ill-fitting mandibular dentures were chosen for 14 fully edentulous male patients with adequate dental hygiene, enough interarch space, and free of systemic diseases and parafunctional habits. Patients who received new dentures (CDs) were randomly allocated into each group using computer software, and four interforaminal implants were inserted in parallel using a surgical guide. Three months after osseointegration, the patients received either CAD-CAM BioHPP framework hybrid prosthesis (Group I) or BioHPP bar supported and retained overdenture (Group II). Using digital preapical radiography, the bone loss is evaluated 6, 12, and 18 months after insertion. The subjective patient evaluation was done using a questionnaire based on the VAS includes five points for chewing, comfort, esthetics, speech, oral hygiene, and general satisfaction. Results The overall marginal bone loss (MBL) revealed that Group I (hybrid prosthesis) was more than Group II (bar overdenture) at all intervals in the anterior and posterior implants' mesial and distal surfaces. The patient satisfaction survey results showed that, after 18 months, the difference was statistically not significant between them all (P > 0.05) except for the comfort (for the overdenture group, 4.43 ± 0.53 while the fixed hybrid was 5.00 ± 0.00). Conclusion BioHPP framework material is an alternative material for implant rehabilitation of edentulous mandible with minimal MBL in BioHPP bar overdenture compared to BioHPP hybrid prosthesis.
Collapse
Affiliation(s)
- Hanan Mohsen Al-Asad
- Faculty of Dentistry, Aden University, Aden, Yemen
- University of Science and Technology, Aden, Yemen
| | | | | | | |
Collapse
|
2
|
Cheng Y, Xiao C, Zhu Y, Chen Q, Zhang L, Zhang Y, Gao M, Li X, Zhou Y, Song G, Zhang T, Pei R. Three-year observations on the effect of different cusp inclinations on the restoration of short maxillary first molar implants: A randomized controlled trial. Front Physiol 2023; 13:992800. [PMID: 36685182 PMCID: PMC9845769 DOI: 10.3389/fphys.2022.992800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 10/11/2022] [Indexed: 01/06/2023] Open
Abstract
Objective: To investigate the effect of different cusp inclination on short implant prosthesis of maxillary first molar after 3 years of weight-bearing in biology and mechanics. Methods: The clinical patients were randomly selected from the database and divided into four groups A, B, C, and D according to the cusp inclination of the maxillary first molar short implant restoration (4.8 mm × 8 mm, Dentium). 20 cases in each group. The cusp inclination was 10 degrees-15 degrees, 15 degrees-20 degrees, 20 degrees-25 degrees, 25 degrees-30 degrees. After 3 years of weight-bearing, cone beam computed tomography (CBCT) and Florida probe were used to measure and observe the height of alveolar bone (H), periodontal probing depth (PD) and modified sulcus bleeding index (MBI). Visual analogue scale (VAS) was used to evaluate the overall satisfaction of patients, and the mechanical complications of each group within 3 years of implant weight-bearing were counted. Results: The H and PD of group D were 1.09 ± 0.23 and 2.19 ± 0.11 respectively, which were significantly higher than those of group A, B and C (p < 0.05). There was no significant difference in MBI between groups A-D (p > 0.05). The VAS scores of group B and group C were 88.36 ± 5.12 and 88.70 ± 4.52 respectively, which were higher than those of group A and group D (p < 0.05). The incidence of food impaction, porcelain collapse and abutment loosening in group D were 40.0%, 25.0% and 15.0% respectively, which were higher than those in group B and C (p < 0.05). Conclusion: The risk of biological and mechanical complications increases after long-term weight-bearing of maxillary first molar short implant prostheses with high cusp inclination. The cusp inclination of short implant prostheses should be designed as low as 25 degrees.
Collapse
Affiliation(s)
- Yuye Cheng
- Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Cong Xiao
- Department of Orthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Yu Zhu
- Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Qiuyan Chen
- Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Longbo Zhang
- Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Yanshu Zhang
- Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Meiqin Gao
- Department of Orthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Xinpei Li
- Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Yan Zhou
- Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Guiqiang Song
- Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Tiecheng Zhang
- Department of Anesthesiology, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China
| | - Runsheng Pei
- Department of Prosthodontics, Nantong Stomatological Hospital, The Affiliated Nantong Stomatological Hospital of Nantong University, Nantong, Jiangsu, China,*Correspondence: Runsheng Pei,
| |
Collapse
|
3
|
Topcu Ersöz MB, Mumcu E. Biomechanical investigation of maxillary implant-supported full-arch prostheses produced with different framework materials: a finite elements study. J Adv Prosthodont 2022; 14:346-359. [PMID: 36685790 PMCID: PMC9832146 DOI: 10.4047/jap.2022.14.6.346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 10/18/2022] [Accepted: 10/19/2022] [Indexed: 12/28/2022] Open
Abstract
PURPOSE Four and six implant-supported fixed full-arch prostheses with various framework materials were assessed under different loading conditions. MATERIALS AND METHODS In the edentulous maxilla, the implants were positioned in a configuration of four to six implant modalities. CoCr, Ti, ZrO2, and PEEK materials were used to produce the prosthetic structure. Using finite element stress analysis, the first molar was subjected to a 200 N axial and 45° oblique force. Stresses were measured on the bone, implants, abutment screw, abutment, and prosthetic screw. The Von Mises, maximum, and minimum principal stress values were calculated and compared. RESULTS The maximum and minimum principal stresses in bone were determined as CoCr < ZrO2 < Ti < PEEK. The Von Mises stresses on the implant, implant screw, abutment, and prosthetic screws were determined as CoCr < ZrO2 < Ti < PEEK. The highest Von Mises stress was 9584.4 Mpa in PEEK material on the prosthetic screw under 4 implant-oblique loading. The highest maximum principal stress value in bone was found to be 120.89 Mpa, for PEEK in 4 implant-oblique loading. CONCLUSION For four and six implant-supported structures, and depending on the loading condition, the system accumulated different stresses. The distribution of stress was reduced in materials with a high elastic modulus. When choosing materials for implant-supported fixed prostheses, it is essential to consider both the number of implants and the mechanical and physical attributes of the framework material.
Collapse
Affiliation(s)
- Mirac Berke Topcu Ersöz
- Department of Prosthodontics, Faculty of Dentistry, Eskisehir Osmangazi University, Eskisehir, Turkey
| | - Emre Mumcu
- Department of Prosthodontics, Faculty of Dentistry, Eskisehir Osmangazi University, Eskisehir, Turkey.,Advanced Material Technologies Application and Research Center, Eskisehir Osmangazi University, Eskisehir, Turkey.,Translational Medicine Research and Clinical Center, Eskisehir Osmangazi University, Eskisehir, Turkey
| |
Collapse
|