1
|
Chen JL, Njoku DI, Tang C, Gao Y, Chen J, Peng YK, Sun H, Mao G, Pan M, Tam NFY. Advances in Microfluidic Paper-Based Analytical Devices (µPADs): Design, Fabrication, and Applications. SMALL METHODS 2024:e2400155. [PMID: 38781604 DOI: 10.1002/smtd.202400155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/01/2024] [Indexed: 05/25/2024]
Abstract
Microfluidic Paper-based Analytical Devices (µPADs) have emerged as a new class of microfluidic systems, offering numerous advantages over traditional microfluidic chips. These advantages include simplicity, cost-effectiveness, stability, storability, disposability, and portability. As a result, various designs for different types of assays are developed and investigated. In recent years, µPADs are combined with conventional detection methods to enable rapid on-site detection, providing results comparable to expensive and sophisticated large-scale testing methods that require more time and skilled personnel. The application of µPAD techniques is extensive in environmental quality control/analysis, clinical diagnosis, and food safety testing, paving the way for on-site real-time diagnosis as a promising future development. This review focuses on the recent research advancements in the design, fabrication, material selection, and detection methods of µPADs. It provides a comprehensive understanding of their principles of operation, applications, and future development prospects.
Collapse
Affiliation(s)
- Jian Lin Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
| | - Demian Ifeanyi Njoku
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Cui Tang
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yaru Gao
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Jiayu Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Yung-Kang Peng
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Hongyan Sun
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| | - Guozhu Mao
- School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, P. R. China
| | - Min Pan
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
| | - Nora Fung-Yee Tam
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Kowloon, Hong Kong SAR, P. R. China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
- Shenzhen Research Institute of City University of Hong Kong, Shenzhen, 518057, P. R. China
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, P. R. China
| |
Collapse
|
2
|
Dai W, Inumbra B, Wong PY, Sarmiento A, Yau Y, Han J, Mao G, Peng YK, Chen JL. A Dye-Assisted Paper-Based Assay to Rapidly Differentiate the Stress of Chlorophenols and Heavy Metals on Enterococcus faecalis and Escherichia coli. BIOSENSORS 2023; 13:bios13050523. [PMID: 37232884 DOI: 10.3390/bios13050523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 05/01/2023] [Accepted: 05/04/2023] [Indexed: 05/27/2023]
Abstract
Biological toxicity testing plays an essential role in identifying the possible negative effects induced by substances such as organic pollutants or heavy metals. As an alternative to conventional methods of toxicity detection, paper-based analytical device (PAD) offers advantages in terms of convenience, quick results, environmental friendliness, and cost-effectiveness. However, detecting the toxicity of both organic pollutants and heavy metals is challenging for a PAD. Here, we show the evaluation of biotoxicity testing for chlorophenols (pentachlorophenol, 2,4-dichlorophenol, and 4-chlorophenol) and heavy metals (Cu2+, Zn2+, and Pb2+) by a resazurin-integrated PAD. The results were achieved by observing the colourimetric response of bacteria (Enterococcus faecalis and Escherichia coli) to resazurin reduction on the PAD. The toxicity responses of E. faecalis-PAD and E. coli-PAD to chlorophenols and heavy metals can be read within 10 min and 40 min, respectively. Compared to the traditional growth inhibition experiments for toxicity measuring which takes at least 3 h, the resazurin-integrated PAD can recognize toxicity differences between studied chlorophenols and between studied heavy metals within 40 min.
Collapse
Affiliation(s)
- Wanqing Dai
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
| | - Bibi Inumbra
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
| | - Po Yu Wong
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
| | - Alma Sarmiento
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
| | - Ying Yau
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
| | - Jie Han
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
| | - Guozhu Mao
- School of Environmental Science and Engineering, Tianjin University, Tianjin 300350, China
| | - Yung-Kang Peng
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, China
| | - Jian Lin Chen
- Department of Applied Science, School of Science and Technology, Hong Kong Metropolitan University, Good Shepherd Street, Ho Man Tin, Hong Kong SAR, China
- State Key Laboratory of Marine Pollution, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR, China
| |
Collapse
|
3
|
Elvira KS, Gielen F, Tsai SSH, Nightingale AM. Materials and methods for droplet microfluidic device fabrication. LAB ON A CHIP 2022; 22:859-875. [PMID: 35170611 PMCID: PMC9074766 DOI: 10.1039/d1lc00836f] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Accepted: 01/21/2022] [Indexed: 05/19/2023]
Abstract
Since the first reports two decades ago, droplet-based systems have emerged as a compelling tool for microbiological and (bio)chemical science, with droplet flow providing multiple advantages over standard single-phase microfluidics such as removal of Taylor dispersion, enhanced mixing, isolation of droplet contents from surfaces, and the ability to contain and address individual cells or biomolecules. Typically, a droplet microfluidic device is designed to produce droplets with well-defined sizes and compositions that flow through the device without interacting with channel walls. Successful droplet flow is fundamentally dependent on the microfluidic device - not only its geometry but moreover how the channel surfaces interact with the fluids. Here we summarise the materials and fabrication techniques required to make microfluidic devices that deliver controlled uniform droplet flow, looking not just at physical fabrication methods, but moreover how to select and modify surfaces to yield the required surface/fluid interactions. We describe the various materials, surface modification techniques, and channel geometry approaches that can be used, and give examples of the decision process when determining which material or method to use by describing the design process for five different devices with applications ranging from field-deployable chemical analysers to water-in-water droplet creation. Finally we consider how droplet microfluidic device fabrication is changing and will change in the future, and what challenges remain to be addressed in the field.
Collapse
Affiliation(s)
- Katherine S Elvira
- Department of Chemistry, Faculty of Science, University of Victoria, BC, Canada
| | - Fabrice Gielen
- Living Systems Institute, College of Engineering, Physics and Mathematics, University of Exeter, Exeter, EX4 4QD, UK
| | - Scott S H Tsai
- Department of Mechanical and Industrial Engineering, Ryerson University, ON, Canada
- Institute for Biomedical Engineering, Science, and Technology (iBEST)-a partnership between Ryerson University and St. Michael's Hospital, ON, Canada
- Keenan Research Centre for Biomedical Science, St. Michael's Hospital, ON, Canada
| | - Adrian M Nightingale
- Mechanical Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK
- Centre of Excellence for Continuous Digital Chemical Engineering Science, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, SO17 1BJ, UK.
| |
Collapse
|
4
|
Sun Q, Tam NFY, Han J, Yung-Kang Peng W, Zhu Z, Chen JL. A simple paper-based colorimetric analytical device for rapid detection of Enterococcus faecalis under the stress of chlorophenols. Talanta 2021; 225:121966. [PMID: 33592720 DOI: 10.1016/j.talanta.2020.121966] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Revised: 11/17/2020] [Accepted: 11/30/2020] [Indexed: 10/22/2022]
Abstract
Bacteria detection and toxicity measurement are essential in many aspects. Becoming increasingly popular in recent years, paper-based analytical devices (PADs) have proven to be cost-effective, portable and eco-friendly with quantitative diagnostic results. In this work, by a straightforward soaking-drying method, a resazurin-deposited PAD has been developed for rapid bacteria detection and biotoxicity measurement. The colorimetric response on the PAD was generated from metabolic reduction of resazurin by Enterococcus faecalis, a facultative anaerobic bacterial strain. After recording and quantifying the colorimetric response with Hue value by a smartphone, the bioassay on PAD enables the detection of resazurin reduction kinetics difference among bacteria at various densities in 10 min. Thereby, the bioassay on PAD was applied to study the toxicity of two chlorophenols, i.e. pentachlorophenol (PCP) and 4-chlorophenol (4-CP), to E. faecalis. Compared to growth-based inhibition test, which takes 5 h, this assay shows higher efficiency, i.e. in 30 min, the biotoxicity difference between PCP and 4-CP can be identified.
Collapse
Affiliation(s)
- Qidi Sun
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Nora F Y Tam
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China; Department of Science, School of Science and Technology, The Open University of Hong Kong, Good Shepherd Street, Ho Man Tin, Hong Kong, China
| | - Jie Han
- Department of Science, School of Science and Technology, The Open University of Hong Kong, Good Shepherd Street, Ho Man Tin, Hong Kong, China
| | - Will Yung-Kang Peng
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Zonglong Zhu
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China
| | - Jian Lin Chen
- Department of Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, China; Department of Science, School of Science and Technology, The Open University of Hong Kong, Good Shepherd Street, Ho Man Tin, Hong Kong, China.
| |
Collapse
|
5
|
Sun J, Ren Y, Ji J, Guo Y, Sun X. A novel concentration gradient microfluidic chip for high-throughput antibiotic susceptibility testing of bacteria. Anal Bioanal Chem 2021; 413:1127-1136. [PMID: 33420534 DOI: 10.1007/s00216-020-03076-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 11/12/2020] [Accepted: 11/16/2020] [Indexed: 11/29/2022]
Abstract
Antibiotic resistance has become a serious threat to food safety and public health globally. Therefore, the development of a sensitive, quick, and simple method for antibiotic susceptibility testing is an urgent and crucial need. A novel concentration gradient microfluidic chip was designed in this work to generate antibiotic concentration gradient, culture bacteria, and produce fluorescence emission. An in-house-assembled fluorescence detection platform was constructed, and experiments were conducted to verify the linearity of the generated concentration gradient, explore the appropriate incubation time and flow rate for the microfluidic chip, and study the effect of long-term acid-based food processing on antibiotic susceptibility testing. Experimental results show that the concentration gradient generated by the microfluidic chip exhibited good linearity, stability, and controllability. The appropriate flow rate and incubation time for the microfluidic chip were 2 μL/min and 5 h, respectively. The use of this microfluidic chip for testing antibiotic resistance of Salmonella to ofloxacin and ampicillin generated results that were completely consistent with test results obtained using the gold-standard method. Furthermore, Salmonella showed greater sensitivity to antibiotics under strong acid conditions, confirming the potential influence of acid-based food processing on antibiotic susceptibility testing of real samples. The designed microfluidic chip provides a high-throughput, sensitive, and rapid antibiotic susceptibility testing method that combines the microfluidic chip and the fluorescence detection platform. The application of this method would facilitate determination of antibiotic-resistant bacterial strains for clinicians and researchers, and enable monitoring of changes in bacterial resistance during food processing.
Collapse
Affiliation(s)
- Jiadi Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, 214122, Jiangsu, China.,State Key Laboratory of Dairy Biotechnology,Shanghai Engineering Research Center of Dairy Biotechnology, Dairy Research Institute, Bright Dairy & Food Co., Ltd., Shanghai, 200436, Shanghai, China
| | - Yijing Ren
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, 214122, Jiangsu, China
| | - Jian Ji
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, 214122, Jiangsu, China
| | - Yu Guo
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, 214122, Jiangsu, China.,School of Internet of Things Engineering, Jiangnan University, Jiangsu, 214122, Wuxi, People's Republic of China
| | - Xiulan Sun
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, National Engineering Research Center for Functional Food, Synergetic Innovation Center of Food Safety and Quality Control, Jiangnan University, Wuxi, 214122, Jiangsu, China.
| |
Collapse
|
6
|
Ortiz R, Stuckey DC, Steele TW. Rapid EC50 determination of hydrophobic toxicants in continuous droplet biomicrofluidics. MICRO AND NANO ENGINEERING 2019. [DOI: 10.1016/j.mne.2019.05.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|