de Buck MHS, Hess AT, Jezzard P. Simulation-based optimization and experimental comparison of intracranial T2-weighted DANTE-SPACE vessel wall imaging at 3T and 7T. Magn Reson Med 2024; 92:2112-2126. [PMID: 38970460 DOI: 10.1002/mrm.30203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 04/30/2024] [Accepted: 06/12/2024] [Indexed: 07/08/2024]
Abstract
PURPOSE T2-weighted DANTE-SPACE (Delay Alternating with Nutation for Tailored Excitation - Sampling Perfection with Application optimized Contrasts using different flip angle Evolution) sequences facilitate non-invasive intracranial vessel wall imaging at 7T through simultaneous suppression of blood and CSF. However, the achieved vessel wall delineation depends closely on the selected sequence parameters, and little information is available about the performance of the sequence using more widely available 3T MRI. Therefore, in this paper a comprehensive DANTE-SPACE simulation framework is used for the optimization and quantitative comparison of T2-weighted DANTE-SPACE at both 7T and 3T. METHODS Simulations are used to propose optimized sequence parameters at both 3T and 7T. At 7T, an additional protocol which uses a parallel transmission (pTx) shim during the DANTE preparation for improved suppression of inflowing blood is also proposed. Data at both field strengths using optimized and literature protocols are acquired and quantitatively compared in six healthy volunteers. RESULTS At 7T, more vessel wall signal can be retained while still achieving sufficient CSF suppression by using fewer DANTE pulses than described in previous implementations. The use of a pTx shim during DANTE at 7T provides a modest further improvement to the inner vessel wall delineation. At 3T, aggressive DANTE preparation is required to achieve CSF suppression, resulting in reduced vessel wall signal. As a result, the achievable vessel wall definition at 3T is around half that of 7T. CONCLUSION Simulation-based optimization of DANTE parameters facilitates improved T2-weighted DANTE-SPACE contrasts at 7T. The improved vessel definition of T2-weighted DANTE-SPACE at 7T makes DANTE preparation more suitable for T2-weighted VWI at 7T than at 3T.
Collapse
Affiliation(s)
- Matthijs H S de Buck
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Spinoza Centre for Neuroimaging, Netherlands Institute for Neuroscience, Royal Netherlands Academy for Arts and Sciences (KNAW), Amsterdam, The Netherlands
| | - Aaron T Hess
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Peter Jezzard
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| |
Collapse
|
2
|
de Buck MHS, Jezzard P, Hess AT. An extended phase graph-based framework for DANTE-SPACE simulations including physiological, temporal, and spatial variations. Magn Reson Med 2024; 92:332-345. [PMID: 38469983 DOI: 10.1002/mrm.30071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 01/18/2024] [Accepted: 02/09/2024] [Indexed: 03/13/2024]
Abstract
PURPOSE The delay alternating with nutation for tailored excitation (DANTE)-sampling perfection with application-optimized contrasts (SPACE) sequence facilitates 3D intracranial vessel wall imaging with simultaneous suppression of blood and CSF. However, the achieved image contrast depends closely on the selected sequence parameters, and the clinical use of the sequence is limited in vivo by observed signal variations in the vessel wall, CSF, and blood. This paper introduces a comprehensive DANTE-SPACE simulation framework, with the aim of providing a better understanding of the underlying contrast mechanisms and facilitating improved parameter selection and contrast optimization. METHODS An extended phase graph formalism was developed for efficient spin ensemble simulation of the DANTE-SPACE sequence. Physiological processes such as pulsatile flow velocity variation, varying flow directions, intravoxel velocity variation, diffusion, andB 1 + $$ {\mathrm{B}}_1^{+} $$ effects were included in the framework to represent the mechanisms behind the achieved signal levels accurately. RESULTS Intravoxel velocity variation improved temporal stability and robustness against small velocity changes. Time-varying pulsatile velocity variation affected CSF simulations, introducing periods of near-zero velocity and partial rephasing. Inclusion of diffusion effects was found to substantially reduce the CSF signal. Blood flow trajectory variations had minor effects, butB 1 + $$ {\mathrm{B}}_1^{+} $$ differences along the trajectory reduced DANTE efficiency in low-B 1 + $$ {\mathrm{B}}_1^{+} $$ areas. Introducing low-velocity pulsatility of both CSF and vessel wall helped explain the in vivo observed signal heterogeneity in both tissue types. CONCLUSION The presented simulation framework facilitates a more comprehensive optimization of DANTE-SPACE sequence parameters. Furthermore, the simulation framework helps to explain observed contrasts in acquired data.
Collapse
Affiliation(s)
- Matthijs H S de Buck
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
- Spinoza Centre for Neuroimaging, Amsterdam, The Netherlands
| | - Peter Jezzard
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | - Aaron T Hess
- Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| |
Collapse
|
3
|
Abstract
Vessel wall MR imaging (VW-MRI) has been introduced into clinical practice and applied to a variety of diseases, and its usefulness has been reported. High-resolution VW-MRI is essential in the diagnostic workup and provides more information than other routine MR imaging protocols. VW-MRI is useful in assessing lesion location, morphology, and severity. Additional information, such as vessel wall enhancement, which is useful in the differential diagnosis of atherosclerotic disease and vasculitis could be assessed by this special imaging technique. This review describes the VW-MRI technique and its clinical applications in arterial disease, venous disease, vasculitis, and leptomeningeal disease.
Collapse
|
4
|
Gong Y, Cao C, Guo Y, Chang B, Sheng Z, Shen W, Zou Y, Lu X, Xing J, Xia S. Quantification of intracranial arterial stenotic degree evaluated by high-resolution vessel wall imaging and time-of-flight MR angiography: reproducibility, and diagnostic agreement with DSA. Eur Radiol 2021; 31:5479-5489. [PMID: 33585995 DOI: 10.1007/s00330-021-07719-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 12/17/2020] [Accepted: 01/27/2021] [Indexed: 12/20/2022]
Abstract
OBJECTIVES The purpose of this study was to compare the reproducibility and diagnostic agreement of high-resolution vessel wall imaging (HR-VWI) and time-of-flight magnetic resonance angiography (TOF-MRA) with digital subtraction angiography (DSA) to evaluate intracranial arterial stenosis. METHODS We retrospectively enrolled patients who underwent HR-VWI and TOF-MRA with suspected intracranial artery disease and had DSA results from our institutional imaging database. Two neuroradiologists separately and independently evaluated anonymous image data for the stenotic lesions. DSA was analyzed by two neurointerventionalists and it served as a standard criterion. The reproducibility of these two MR techniques was determined by the intraclass correlation coefficients (ICCs). The diagnostic agreement to DSA was assessed by the concordance correlation coefficients (CCCs). RESULTS A total of 246 lesions from 106 individuals were analyzed for stenotic degrees. The total intra-observer and inter-observer reproducibility of HR-VWI was excellent for identifying stenosis and better than of TOF-MRA. The overall concordance of HR-VWI with DSA was excellent with CCC = 0.932, whereas TOF-MRA was 0.694. In addition, HR-VWI could provide additional vessel wall information. CONCLUSIONS HR-VWI has more advantages over TOF-MRA, such as better reproducibilities and diagnostic agreements with DSA to analyze intracranial arterial stenosis. It provides additional information that helps in clinical diagnosis and management. KEY POINTS • High-resolution vessel wall imaging can assess intracranial arterial stenosis with a better reproducibility than TOF-MRA and has a higher diagnostic agreement with DSA. • High-resolution vessel wall imaging had a higher diagnostic agreement with DSA compared with TOF-MRA. • Apart from evaluating vascular stenosis, HR-VWI provided additional vessel wall information to help in clinical diagnosis.
Collapse
Affiliation(s)
- Yan Gong
- Department of Radiology, First Central Clinical College, Tianjin Medical University, Tianjin, 300192, China.,Department of Radiology, Tianjin Medical University Nankai Hospital, Tianjin, 300100, China
| | - Chen Cao
- Department of Radiology, First Central Clinical College, Tianjin Medical University, Tianjin, 300192, China.,Department of Radiology, Tianjin Huanhu Hospital, Key Laboratory for Cerebral Artery and Neural Degeneration of Tianjin, Tianjin, 300350, China
| | - Yu Guo
- Department of Radiology, Tianjin First Central Hospital, School of Medical, Nankai University, Tianjin, 300192, China
| | - Binge Chang
- Department of Neurosurgery, Tianjin First Central Hospital, School of Medical, Nankai University, Tianjin, 300192, China
| | - Zhiguo Sheng
- Department of Neurosurgery, Tianjin First Central Hospital, School of Medical, Nankai University, Tianjin, 300192, China
| | - Wen Shen
- Department of Radiology, Tianjin First Central Hospital, School of Medical, Nankai University, Tianjin, 300192, China
| | - Ying Zou
- Department of Radiology, First Central Clinical College, Tianjin Medical University, Tianjin, 300192, China.,Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, 300381, China
| | - Xiudi Lu
- Department of Radiology, First Central Clinical College, Tianjin Medical University, Tianjin, 300192, China.,Department of Radiology, First Teaching Hospital of Tianjin University of Traditional Chinese Medicine, Tianjin, 300381, China
| | - Jiahua Xing
- School of Medicine, Nankai University, Tianjin, 300071, China
| | - Shuang Xia
- Department of Radiology, Tianjin First Central Hospital, School of Medical, Nankai University, Tianjin, 300192, China.
| |
Collapse
|
5
|
Oshima S, Fushimi Y, Okada T, Nakajima S, Yokota Y, Shima A, Grinstead J, Ahn S, Sawamoto N, Takahashi R, Nakamoto Y. Neuromelanin-Sensitive Magnetic Resonance Imaging Using DANTE Pulse. Mov Disord 2020; 36:874-882. [PMID: 33314293 PMCID: PMC8247273 DOI: 10.1002/mds.28417] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 10/14/2020] [Accepted: 11/16/2020] [Indexed: 12/22/2022] Open
Abstract
Background Neuromelanin‐sensitive magnetic resonance imaging techniques have been developed but currently require relatively long scan times. The aim of this study was to assess the ability of black‐blood delay alternating with nutation for tailored excitation‐prepared T1‐weighted variable flip angle turbo spin echo (DANTE T1‐SPACE), which provides relatively high resolution with a short scan time, to visualize neuromelanin in the substantia nigra pars compacta (SNpc). Methods Participants comprised 49 healthy controls and 25 patients with Parkinson's disease (PD). Contrast ratios of SNpc and hyperintense SNpc areas, which show pixels brighter than thresholds, were assessed between DANTE T1‐SPACE and T1‐SPACE in healthy controls. To evaluate the diagnostic ability of DANTE T1‐SPACE, the contrast ratios and hyperintense areas were compared between healthy and PD groups, and receiver operating characteristic analyses were performed. We also compared areas under the curve (AUCs) between DANTE T1‐SPACE and the previously reported gradient echo neuromelanin (GRE‐NM) imaging. Each analysis was performed using original images in native space and images transformed into Montreal Neurological Institute space. Values of P < 0.05 were considered significant. Results DANTE T1‐SPACE showed significantly higher contrast ratios and larger hyperintense areas than T1‐SPACE. On DANTE T1‐SPACE, healthy controls showed significantly higher contrast ratios and larger hyperintense areas than patients with PD. Hyperintense areas in native space analysis achieved the best AUC (0.94). DANTE T1‐SPACE showed AUCs as high as those of GRE‐NM. Conclusions DANTE T1‐SPACE successfully visualized neuromelanin of the SNpc and showed potential for evaluating PD. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society ![]()
Collapse
Affiliation(s)
- Sonoko Oshima
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yasutaka Fushimi
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Tomohisa Okada
- Human Brain Research Center, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Satoshi Nakajima
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yusuke Yokota
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Atsushi Shima
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | | | - Sinyeob Ahn
- Siemens Healthineers, San Francisco, California, USA
| | - Nobukatsu Sawamoto
- Department of Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Ryosuke Takahashi
- Department of Neurology, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Yuji Nakamoto
- Department of Diagnostic Imaging and Nuclear Medicine, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| |
Collapse
|
6
|
Zhang N, Lyu J, Ren L, Zhang L, Fan Z, Wan L, Li Y, Liang D, Zheng H, Liu X. Arterial culprit plaque characteristics revealed by magnetic resonance Vessel Wall imaging in patients with single or multiple infarcts. Magn Reson Imaging 2020; 84:12-17. [PMID: 32534066 DOI: 10.1016/j.mri.2020.06.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Revised: 05/15/2020] [Accepted: 06/09/2020] [Indexed: 01/03/2023]
Abstract
PURPOSE To investigate characteristics of intra- and extracranial arterial culprit plaques between patients with single infarct and multiple-infarcts by a head-neck combined high resolution magnetic resonance vessel wall imaging (HR-MRVWI). MATERIALS AND METHODS Forty-three patients with recent ischemic stroke due to large artery atherosclerosis were enrolled. The head-neck combined HR-MRVWI was performed in all patients both pre- and post-contrast administration. Based on diffusion weighted imaging findings, patients were divided into single-infarction and multiple-infarction groups. For patients with anterior circulation ischemic stroke, they were also divided into perforating artery infarction (PAI) and non-PAI groups. Patient demographics, number and location of culprit plaques, artery stenosis percentage, intraplaque hemorrhage, and plaque enhancement were evaluated and compared between single-infarction and multiple-infarction groups, as well as between PAI and non-PAI groups. RESULTS A total of 83 culprit plaques were identified. The artery stenosis degree was more severe and plaque enhancement more prominent in multiple-infarction group than in single-infarction group. Patients with multiple infarcts also had more culprit plaques per patient than those with single infarct, which contributed to the occurrence of multiple infarcts. For comparison of PAI and non-PAI groups, a higher artery stenosis percentage was observed in non-PAI group, and patients with non-PAI had more culprit plaques per patient, which contributed to a variety of infarct manifestations. CONCLUSION A higher stenosis grade and higher number of culprit plaques seem to be associated with a higher number of cerebral infarcts in patients with large artery atherosclerosis.
Collapse
Affiliation(s)
- Na Zhang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Jinhao Lyu
- Department of Radiology, Chinese People's Liberation Army (PLA) General Hospital, Beijing, China
| | - Lijie Ren
- Department of Neurology, Shenzhen Second People's Hospital, Shenzhen, China
| | - Lei Zhang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Zhangyan Fan
- Department of Neurology, Shenzhen Second People's Hospital, Shenzhen, China
| | - Liwen Wan
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Ye Li
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Dong Liang
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Xin Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China; CAS key Laboratory of Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
| |
Collapse
|