1
|
Choi ES, Kim JS, Nickel MD, Sung JK, Lee JK. Free-breathing contrast-enhanced multiphase MRI of the liver in patients with a high risk of breath-holding failure: comparison of compressed sensing-accelerated radial and Cartesian acquisition techniques. Acta Radiol 2021; 63:1453-1462. [PMID: 34839679 DOI: 10.1177/02841851211052988] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Knowing the advantages and disadvantages of each magnetic resonance (MR) technique, would allow us to choose a sequence better suited in patients with a high risk of breath-holding failure. PURPOSE To compare the image quality of free-breathing contrast-enhanced multiphase MR imaging (MRI) using incoherent Cartesian k-space sampling combined with a motion-resolved compressed sensing reconstruction (XD-VIBE) and Golden-Angle Radial Sparse Parallel MRI (GRASP). MATERIAL AND METHODS A total of 67 patients were included. Overall image quality, motion artifacts, and liver edge sharpness on arterial and portal-venous phase were evaluated by two radiologists. We evaluated the signal intensity ratio between liver in the late arterial phase to aorta at peak enhancement and the detection rate of hypervascular lesions. RESULTS Overall image quality, artifact, and liver edge sharpness scores of XD-VIBE and GRASP were not significantly different (P = 0.070-0.397). Four (reviewer 1, 12.1%) and seven patients (reviewer 2, 21.2%) received non-diagnostic quality in the XD-VIBE group whereas one patient (reviewer 2, 2.9%) received non-diagnostic quality in the GRASP group. The ratio between the aorta and liver signal for GRASP was significantly higher than that of XD-VIBE (0.32 ± 0.10 vs. 0.47 ± 0.13; P < 0.001). The hypervascular lesion detection rate of XD-VIBE (86.7%) was higher than that of GRASP (57.1%) in the arterial phase without a statistically significant difference (P = 0.081). CONCLUSION Overall image quality of XD-VIBE and GRASP were not significantly different. More XD-VIBE examinations were rated non-diagnostic. On the other hand, the relative liver parenchymal enhancement to the aorta in the late arterial phase of GRASP was higher than that of XD-VIBE, which potentially leads to lower detectability of hypervascular lesions on arterial phase images.
Collapse
Affiliation(s)
- Eun Sun Choi
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | - Jin Sil Kim
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| | | | - Jae Kon Sung
- Siemens Healthineers Ltd, Seoul, Republic of Korea
| | - Jeong Kyong Lee
- Department of Radiology, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
| |
Collapse
|
2
|
Röwer LM, Uelwer T, Hußmann J, Malik H, Eichinger M, Voit D, Wielpütz MO, Frahm J, Harmeling S, Klee D, Pillekamp F. Spirometry-based reconstruction of real-time cardiac MRI: Motion control and quantification of heart-lung interactions. Magn Reson Med 2021; 86:2692-2702. [PMID: 34272760 DOI: 10.1002/mrm.28892] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 05/13/2021] [Accepted: 05/31/2021] [Indexed: 02/06/2023]
Abstract
PURPOSE To test the feasibility of cardiac real-time MRI in combination with retrospective gating by MR-compatible spirometry, to improve motion control, and to allow quantification of respiratory-induced changes during free-breathing. METHODS Cross-sectional real-time MRI (1.5T; 30 frames/s) using steady-state free precession contrast during free-breathing was combined with MR-compatible spirometry in healthy adult volunteers (n = 4). Retrospective binning assigned images to classes that were defined by electrocardiogram and spirometry. Left ventricular eccentricity index as an indicator of septal position and ventricular volumes in different respiratory phases were calculated to assess heart-lung interactions. RESULTS Real-time MRI with MR-compatible spirometry is feasible and well tolerated. Spirometry-based binning improved motion control significantly. The end-diastolic epicardial eccentricity index increased significantly during inspiration (1.04 ± 0.04 to 1.19 ± 0.05; P < .05). During inspiration, right ventricular end-diastolic volume (79 ± 17 mL/m2 to 98 ± 18 mL/m2 ), stroke volume (41 ± 8 mL/m2 to 59 ± 11 mL/m2 ) and ejection fraction (53 ± 3% to 60 ± 1%) increased significantly, whereas the end-systolic volume remained almost unchanged. Left ventricular end-diastolic volume, left ventricular stroke volume, and left ventricular ejection fraction decreased during inspiration, whereas the left ventricular end-systolic volume increased. The relationship between stroke volume and end-diastolic volume (Frank-Starling relationship) based on changes induced by respiration allowed for a slope estimate of the Frank-Starling curve to be 0.9 to 1.1. CONCLUSION Real-time MRI during free-breathing combined with MR-compatible spirometry and retrospective binning improves image stabilization, allows quantitative image analysis, and importantly, offers unique opportunities to judge heart-lung interactions.
Collapse
Affiliation(s)
- Lena Maria Röwer
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital Düsseldorf, Düsseldorf, Germany.,Department of Diagnostic and Interventional Radiology, Heinrich Heine University, Düsseldorf, Germany
| | - Tobias Uelwer
- Department of Computer Science, Heinrich Heine University, Düsseldorf, Germany
| | - Janina Hußmann
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital Düsseldorf, Düsseldorf, Germany.,Department of Diagnostic and Interventional Radiology, Heinrich Heine University, Düsseldorf, Germany
| | - Halima Malik
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital Düsseldorf, Düsseldorf, Germany.,Department of Diagnostic and Interventional Radiology, Heinrich Heine University, Düsseldorf, Germany
| | - Monika Eichinger
- Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Thoraxklinik, University of Heidelberg, Heidelberg, Germany.,Department of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Heidelberg, Germany.,Translational Lung Research Center Heidelberg, German Center for Lung Research, Heidelberg, Germany
| | - Dirk Voit
- Biomedizinische NMR, Max-Planck Institute for Biophysical Chemistry, Göttingen, Germany
| | - Mark Oliver Wielpütz
- Department of Diagnostic and Interventional Radiology with Nuclear Medicine, Thoraxklinik, University of Heidelberg, Heidelberg, Germany.,Department of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Heidelberg, Germany.,Translational Lung Research Center Heidelberg, German Center for Lung Research, Heidelberg, Germany
| | - Jens Frahm
- Biomedizinische NMR, Max-Planck Institute for Biophysical Chemistry, Göttingen, Germany.,Partner Site Göttingen, German Centre for Cardiovascular Research, Berlin, Germany
| | - Stefan Harmeling
- Department of Computer Science, Heinrich Heine University, Düsseldorf, Germany
| | - Dirk Klee
- Department of Diagnostic and Interventional Radiology, Heinrich Heine University, Düsseldorf, Germany
| | - Frank Pillekamp
- Department of General Pediatrics, Neonatology and Pediatric Cardiology, University Children's Hospital Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
3
|
Nicolò A, Massaroni C, Schena E, Sacchetti M. The Importance of Respiratory Rate Monitoring: From Healthcare to Sport and Exercise. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6396. [PMID: 33182463 PMCID: PMC7665156 DOI: 10.3390/s20216396] [Citation(s) in RCA: 114] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 11/05/2020] [Accepted: 11/08/2020] [Indexed: 12/11/2022]
Abstract
Respiratory rate is a fundamental vital sign that is sensitive to different pathological conditions (e.g., adverse cardiac events, pneumonia, and clinical deterioration) and stressors, including emotional stress, cognitive load, heat, cold, physical effort, and exercise-induced fatigue. The sensitivity of respiratory rate to these conditions is superior compared to that of most of the other vital signs, and the abundance of suitable technological solutions measuring respiratory rate has important implications for healthcare, occupational settings, and sport. However, respiratory rate is still too often not routinely monitored in these fields of use. This review presents a multidisciplinary approach to respiratory monitoring, with the aim to improve the development and efficacy of respiratory monitoring services. We have identified thirteen monitoring goals where the use of the respiratory rate is invaluable, and for each of them we have described suitable sensors and techniques to monitor respiratory rate in specific measurement scenarios. We have also provided a physiological rationale corroborating the importance of respiratory rate monitoring and an original multidisciplinary framework for the development of respiratory monitoring services. This review is expected to advance the field of respiratory monitoring and favor synergies between different disciplines to accomplish this goal.
Collapse
Affiliation(s)
- Andrea Nicolò
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy;
| | - Carlo Massaroni
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy; (C.M.); (E.S.)
| | - Emiliano Schena
- Unit of Measurements and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy; (C.M.); (E.S.)
| | - Massimo Sacchetti
- Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, 00135 Rome, Italy;
| |
Collapse
|