1
|
Pang Y. Orientation dependent proton transverse relaxation in the human brain white matter: The magic angle effect on a cylindrical helix. Magn Reson Imaging 2023; 100:73-83. [PMID: 36965837 DOI: 10.1016/j.mri.2023.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 03/15/2023] [Accepted: 03/21/2023] [Indexed: 03/27/2023]
Abstract
PURPOSE To overcome some limitations of previous proton orientation-dependent transverse relaxation formalisms in human brain white matter (WM) by a generalized magic angle effect function. METHODS A cylindrical helix model was developed embracing anisotropic rotational and translational diffusion of restricted molecules in WM, with the former characterized by an axially symmetric system. Transverse relaxation rates R2 and R2∗ were divided into isotropic R2i and anisotropic parts, R2a ∗ f(α,Φ - ε0), with α denoting an open angle and ε0 an orientation (Φ) offset from DTI-derived primary diffusivity direction. The proposed framework (Fit A) was compared to prior models without ε0 on previously published water and methylene proton transverse relaxation rates from developing, healthy, and pathological WM at 3 T. Goodness of fit was represented by root-mean-square error (RMSE). F-test and linear correlation were used with statistical significance set to P ≤ 0.05. RESULTS Fit A significantly (P < 0.01) outperformed prior models as demonstrated by reduced RMSEs, e.g., 0.349 vs. 0.724 in myelin water. Fitted ε0 was in good agreement with calculated ε0 from directional diffusivities. Compared with those from healthy adult, the fitted R2i, R2a, and α from neonates were substantially reduced but ε0 increased, consistent with developing myelination. Significant positive (R2i) and negative (α and R2a) correlations were found with aging (demyelination) in elderly. CONCLUSION The developed framework can better characterize orientation dependences from a wide range of proton transverse relaxation measurements in the human brain WM, thus shedding new light on myelin microstructural alterations at the molecular level.
Collapse
Affiliation(s)
- Yuxi Pang
- Department of Radiology, University of Michigan, 1500 E. Medical Center Dr., UH B2 RM A205F, Ann Arbor, MI 48109-5030, USA.
| |
Collapse
|
2
|
Adelnia F, Davis LT, Acosta LM, Puckett A, Wang F, Zu Z, Harkins KD, Gore JC. R 1ρ dispersion in white matter correlates with quantitative metrics of cognitive impairment. Neuroimage Clin 2023; 37:103366. [PMID: 36889101 PMCID: PMC10009712 DOI: 10.1016/j.nicl.2023.103366] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 02/21/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023]
Abstract
Much previous neuroimaging research in Alzheimer's disease has focused on the roles of amyloid and tau proteins, but recent studies have implicated microvascular changes in white matter as early indicators of damage related to later dementia. We used MRI to derive novel, non-invasive measurements of R1ρ dispersion using different locking fields to characterize variations of microvascular structure and integrity in brain tissues. We developed a non-invasive 3D R1ρ dispersion imaging technique using different locking fields at 3T. We acquired MR images and cognitive assessments of participants with mild cognitive impairment (MCI) and compared them to age-matched healthy controls in a cross-sectional study. After providing informed consent, 40 adults aged 62 to 82 years (n = 17 MCI) were included in this study. White matter ΔR1ρ-fraction measured by R1ρ dispersion imaging showed a strong correlation with the cognitive status of older adults (βstd = -0.4, p-value < 0.01) independent of age, in contrast to other conventional MRI markers such as T2, R1ρ, and white matter hyperintense lesion volume (WMHs) measured with T2-FLAIR. The correlation of WMHs with cognitive status was no longer significant after adjusting for age and sex in linear regression analysis, and the size of the regression coefficient was substantially decreased (53% lower). This work establishes a new non-invasive method that potentially characterizes impairment of the microvascular structure of white matter in MCI patients compared to healthy controls. The application of this method in longitudinal studies would improve our fundamental understanding of the pathophysiologic changes that accompany abnormal cognitive decline with aging and help identify potential targets for treatment of Alzheimer's disease.
Collapse
Affiliation(s)
- Fatemeh Adelnia
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA.
| | - Larry T Davis
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Lealani Mae Acosta
- Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Amanda Puckett
- Department of Neurology, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Feng Wang
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Zhongliang Zu
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Kevin D Harkins
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| | - John C Gore
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
3
|
Yang Y, Wang C, Liu Y, Chen Z, Liu X, Zheng H, Liang D, Zhu Y. A robust adiabatic constant amplitude spin-lock preparation module for myocardial T 1ρ quantification at 3 T. NMR IN BIOMEDICINE 2023; 36:e4830. [PMID: 36093600 DOI: 10.1002/nbm.4830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 08/25/2022] [Accepted: 09/08/2022] [Indexed: 06/15/2023]
Abstract
T1ρ quantification has the potential to assess myocardial fibrosis without contrast agent. However, its preparation spin-lock pulse is sensitive to B1 and B0 inhomogeneities, resulting in severe banding artifacts in the heart region, especially at high magnetic field such as 3 T. We aimed to design a robust spin-lock (SL) preparation module that can be used in myocardial T1ρ quantification at 3 T. We used the tan/tanh pulse to tip up and tip down the magnetization in the spin-lock preparation module (tan/tanh-SL). Bloch simulation was used to optimize pulse shape parameters of the tan/tanh with a pulse duration (Tp ) of 8, 4, and 2 ms, respectively. The designed tan/tanh-SL modules were implemented on a 3-T MR scanner. They were evaluated in phantom studies under three different cases of B0 and B1 inhomogeneities, and tested in cardiac T1ρ quantification of healthy volunteers. The performance of the tan/tanh-SL was compared with the composite SL preparation pulses and the commonly used hyperbolic secant pulse for spin-lock (HS-SL). Feasible pulse shape parameters were obtained using Bloch simulation. Compared with HS-SL, the quantification error of tan/tanh-SL was reduced by 27.7% for Tp = 8 ms (mean ∆Q = 126.15 vs. 174.42) and 75.6% for Tp = 4 ms (mean ∆Q = 136.65 vs. 559.53). In the phantom study, tan/tanh-SL was less sensitive to B1 and B0 inhomogeneity compared with composite SL pulses and HS-SL. In cardiac T1ρ quantification, the T1ρ maps using tan/tanh-SL showed fewer banding artifacts than using composite SL pulses and HS-SL. The proposed tan/tanh-SL preparation module greatly improves the robustness to B0 and B1 field inhomogeneities and can be used in cardiac T1ρ quantification at 3 T.
Collapse
Affiliation(s)
- Yuxin Yang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Che Wang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Yuanyuan Liu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Zhongmin Chen
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Xin Liu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Hairong Zheng
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Dong Liang
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Yanjie Zhu
- Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| |
Collapse
|
4
|
Pang Y. A self-compensated spin-locking scheme for quantitative R 1ρ dispersion MR imaging in ordered tissues. Magn Reson Imaging 2022; 94:112-118. [PMID: 36181969 DOI: 10.1016/j.mri.2022.09.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 09/01/2022] [Accepted: 09/25/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE To propose a self-compensated spin-locking (SL) method for quantitative R1ρ dispersion imaging in ordered tissues. METHODS Two pairs of antiphase rotary-echo SL pulses were proposed in a new scheme with each pairs sandwiching one refocusing RF pulse. This proposed SL method was evaluated by Bloch simulations and experimental studies relative to three prior schemes. Quantitative R1ρR dispersion imaging studies with constant SL duration (TSL = 40 ms) were carried out on an agarose (1-4% w/v) phantom and one in vivo human knee at 3 T, using six SL RF strengths ranging from 50 to 1000 Hz. The performances of these SL schemes were characterized with an average coefficient of variation (CV) of the signal intensities in agarose gels and the sum of squared errors (SSE) for quantifying in vivo R1ρ dispersion of the femoral and tibial cartilage. RESULTS The simulations demonstrate that the proposed SL scheme was less prone to B0 and B1 field inhomogeneities. This theoretical prediction was supported by fewer image banding artifacts and less signal fluctuation signified by a reduced CV (%) on the phantom without R1ρ dispersion (i.e., 4.04 ± 1.36 vs. 18.87 ± 4.46 or 6.66 ± 2.92 or 5.71 ± 2.05 for others), and further by mostly decreased SSE (*10-3) for characterizing R1ρ dispersion of the femoral (i.e., 0.3 vs. 1.2 or 0.4 or 0.1) and tibial (i.e., 0.4 vs. 7.2 or 3.2 or 2.8) cartilage. CONCLUSION The proposed SL scheme is less sensitive to B0 and B1 field artifacts for a wide range of SL RF strengths and thus more suitable for quantitative R1ρ dispersion imaging in ordered tissues.
Collapse
Affiliation(s)
- Yuxi Pang
- Department of Radiology, University of Michigan, Ann Arbor, MI, USA.
| |
Collapse
|