1
|
Rapley M, Freitas V, Weinberg IN, Baldassi B, Poladyan H, Waterston M, Ghai S, Taeb S, Bubon O, Mulligan AM, Reznik A. Case report: Possible role of low-dose PEM for avoiding unneeded procedures associated with false-positive or equivocal breast MRI results. Front Oncol 2024; 14:1405404. [PMID: 39091907 PMCID: PMC11291220 DOI: 10.3389/fonc.2024.1405404] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2024] [Accepted: 07/05/2024] [Indexed: 08/04/2024] Open
Abstract
Contrast-enhanced breast magnetic resonance imaging (MRI) is currently recommended as a screening tool for high-risk women and has been advocated for women with radiologically dense breast tissue. While breast MRI is acknowledged for its high sensitivity (with an exception for lower-grade ductal carcinoma in situ (DCIS) where emerging techniques like diffusion-weighted imaging offer improvement), its limitations include sensitivity to hormonal changes and a relatively high false-positive rate, potentially leading to overdiagnosis, increased imaging uncertainty, and unnecessary biopsies. These factors can exacerbate patient anxiety and impose additional costs. Molecular imaging with breast-targeted Positron Emission Tomography (PET) has shown the capability to detect malignancy independent of breast density and hormonal changes. Furthermore, breast-targeted PET has shown higher specificity when compared with MRI. However, traditional PET technology is associated with high radiation dose, which can limit its widespread use particularly in repeated studies or for undiagnosed patients. In this case report, we present a clinical application of low-dose breast imaging utilizing a breast-targeted PET camera (Radialis PET imager, Radialis Inc). The case involves a 33-year-old female patient who had multiple enhanced lesions detected on breast MRI after surgical removal of a malignant phyllodes tumor from the right breast. A benign core biopsy was obtained from the largest lesion seen in the left breast. One month after the MRI, 18F-fluorodeoxyglucose (18F-FDG) PET imaging session was performed using the Radialis PET Imager. Although the Radialis PET Imager has proven high count sensitivity and the capability to detect breast lesions with low metabolic activity (at a dose similar to mammography), no areas of increased 18F-FDG uptake were visualized in this particular case. The patient underwent a right-sided nipple-sparing mastectomy and left-sided lumpectomy, with bilateral reconstruction. The excised left breast tissue was completely benign, as suggested by both core biopsy and the PET results. The case presented highlights a promising clinical application of low-dose breast-targeted PET imaging to mitigate the uncertainty associated with MRI while keeping radiation doses within the safe range typically used in X-ray mammography.
Collapse
Affiliation(s)
- Madeline Rapley
- Department of Physics, Lakehead University, Thunder Bay, ON, Canada
| | - Vivianne Freitas
- Temerty Faculty of Medicine, Joint Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | | | | | | | | | - Sandeep Ghai
- Temerty Faculty of Medicine, Joint Department of Medical Imaging, University of Toronto, Toronto, ON, Canada
| | - Samira Taeb
- Department of Research, Princess Margaret Cancer Centre, University Health Network, Toronto, ON, Canada
| | - Oleksandr Bubon
- Department of Physics, Lakehead University, Thunder Bay, ON, Canada
- Radialis Inc., Thunder Bay, ON, Canada
| | - Anna Marie Mulligan
- Laboratory Medicine Program, University Health Network – Toronto General Hospital Site, University of Toronto, Toronto, ON, Canada
| | - Alla Reznik
- Department of Physics, Lakehead University, Thunder Bay, ON, Canada
- Thunder Bay Regional Health Sciences Centre, Thunder Bay, ON, Canada
| |
Collapse
|
2
|
Li X, Johnson JM, Strigel RM, Bancroft LCH, Hurley SA, Estakhraji SIZ, Kumar M, Fowler AM, McMillan AB. Attenuation correction and truncation completion for breast PET/MR imaging using deep learning. Phys Med Biol 2024; 69:045031. [PMID: 38252969 DOI: 10.1088/1361-6560/ad2126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 01/22/2024] [Indexed: 01/24/2024]
Abstract
Objective. Simultaneous PET/MR scanners combine the high sensitivity of MR imaging with the functional imaging of PET. However, attenuation correction of breast PET/MR imaging is technically challenging. The purpose of this study is to establish a robust attenuation correction algorithm for breast PET/MR images that relies on deep learning (DL) to recreate the missing portions of the patient's anatomy (truncation completion), as well as to provide bone information for attenuation correction from only the PET data.Approach. Data acquired from 23 female subjects with invasive breast cancer scanned with18F-fluorodeoxyglucose PET/CT and PET/MR localized to the breast region were used for this study. Three DL models, U-Net with mean absolute error loss (DLMAE) model, U-Net with mean squared error loss (DLMSE) model, and U-Net with perceptual loss (DLPerceptual) model, were trained to predict synthetic CT images (sCT) for PET attenuation correction (AC) given non-attenuation corrected (NAC) PETPET/MRimages as inputs. The DL and Dixon-based sCT reconstructed PET images were compared against those reconstructed from CT images by calculating the percent error of the standardized uptake value (SUV) and conducting Wilcoxon signed rank statistical tests.Main results. sCT images from the DLMAEmodel, the DLMSEmodel, and the DLPerceptualmodel were similar in mean absolute error (MAE), peak-signal-to-noise ratio, and normalized cross-correlation. No significant difference in SUV was found between the PET images reconstructed using the DLMSEand DLPerceptualsCTs compared to the reference CT for AC in all tissue regions. All DL methods performed better than the Dixon-based method according to SUV analysis.Significance. A 3D U-Net with MSE or perceptual loss model can be implemented into a reconstruction workflow, and the derived sCT images allow successful truncation completion and attenuation correction for breast PET/MR images.
Collapse
Affiliation(s)
- Xue Li
- Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI, United States of America
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
| | - Jacob M Johnson
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
| | - Roberta M Strigel
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
- Department of Medical Physics, University of Wisconsin, Madison, WI, United States of America
- University of Wisconsin Carbone Cancer Center, Madison, WI, United States of America
| | - Leah C Henze Bancroft
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
| | - Samuel A Hurley
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
| | - S Iman Zare Estakhraji
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
| | - Manoj Kumar
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
- ICTR Graduate Program in Clinical Investigation, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
| | - Amy M Fowler
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
- Department of Medical Physics, University of Wisconsin, Madison, WI, United States of America
- University of Wisconsin Carbone Cancer Center, Madison, WI, United States of America
| | - Alan B McMillan
- Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI, United States of America
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, United States of America
- Department of Medical Physics, University of Wisconsin, Madison, WI, United States of America
- University of Wisconsin Carbone Cancer Center, Madison, WI, United States of America
| |
Collapse
|
3
|
Perera Molligoda Arachchige AS. Assessing dedicated breast PET performance in breast cancer screening alongside digital mammography, digital breast tomosynthesis, and ultrasound: a reader's insight. Ann Nucl Med 2024; 38:81-82. [PMID: 37943380 DOI: 10.1007/s12149-023-01882-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Accepted: 09/26/2023] [Indexed: 11/10/2023]
|
4
|
Vaz SC, Oliveira C, Teixeira R, Arias-Bouda LMP, Cardoso MJ, de Geus-Oei LF. The current role of nuclear medicine in breast cancer. Br J Radiol 2023; 96:20221153. [PMID: 37097285 PMCID: PMC10461286 DOI: 10.1259/bjr.20221153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 02/24/2023] [Accepted: 02/27/2023] [Indexed: 04/26/2023] Open
Abstract
Breast cancer is the most common cancer in females worldwide. Nuclear medicine plays an important role in patient management, not only in initial staging, but also during follow-up. Radiopharmaceuticals to study breast cancer have been used for over 50 years, and several of these are still used in clinical practice, according to the most recent guideline recommendations.In this critical review, an overview of nuclear medicine procedures used during the last decades is presented. Current clinical indications of each of the conventional nuclear medicine and PET/CT examinations are the focus of this review, and are objectively provided. Radionuclide therapies are also referred, mainly summarising the methods to palliate metastatic bone pain. Finally, recent developments and future perspectives in the field of nuclear medicine are discussed. In this context, the promising potential of new radiopharmaceuticals not only for diagnosis, but also for therapy, and the use of quantitative imaging features as potential biomarkers, are addressed.Despite the long way nuclear medicine has gone through, it looks like it will continue to benefit clinical practice, paving the way to improve healthcare provided to patients with breast cancer.
Collapse
Affiliation(s)
| | - Carla Oliveira
- Nuclear Medicine-Radiopharmacology, Champalimaud Clinical Center, Champalimaud Foundation, Lisbon, Portugal
| | - Ricardo Teixeira
- Nuclear Medicine-Radiopharmacology, Champalimaud Clinical Center, Champalimaud Foundation, Lisbon, Portugal
| | | | | | | |
Collapse
|
5
|
Evaluation of a High-Sensitivity Organ-Targeted PET Camera. SENSORS 2022; 22:s22134678. [PMID: 35808181 PMCID: PMC9269056 DOI: 10.3390/s22134678] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 06/16/2022] [Accepted: 06/17/2022] [Indexed: 02/05/2023]
Abstract
The aim of this study is to evaluate the performance of the Radialis organ-targeted positron emission tomography (PET) Camera with standardized tests and through assessment of clinical-imaging results. Sensitivity, count-rate performance, and spatial resolution were evaluated according to the National Electrical Manufacturers Association (NEMA) NU-4 standards, with necessary modifications to accommodate the planar detector design. The detectability of small objects was shown with micro hotspot phantom images. The clinical performance of the camera was also demonstrated through breast cancer images acquired with varying injected doses of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (18F-FDG) and qualitatively compared with sample digital full-field mammography, magnetic resonance imaging (MRI), and whole-body (WB) PET images. Micro hotspot phantom sources were visualized down to 1.35 mm-diameter rods. Spatial resolution was calculated to be 2.3 ± 0.1 mm for the in-plane resolution and 6.8 ± 0.1 mm for the cross-plane resolution using maximum likelihood expectation maximization (MLEM) reconstruction. The system peak noise equivalent count rate was 17.8 kcps at a 18F-FDG concentration of 10.5 kBq/mL. System scatter fraction was 24%. The overall efficiency at the peak noise equivalent count rate was 5400 cps/MBq. The maximum axial sensitivity achieved was 3.5%, with an average system sensitivity of 2.4%. Selected results from clinical trials demonstrate capability of imaging lesions at the chest wall and identifying false-negative X-ray findings and false-positive MRI findings, even at up to a 10-fold dose reduction in comparison with standard 18F-FDG doses (i.e., at 37 MBq or 1 mCi). The evaluation of the organ-targeted Radialis PET Camera indicates that it is a promising technology for high-image-quality, low-dose PET imaging. High-efficiency radiotracer detection also opens an opportunity to reduce administered doses of radiopharmaceuticals and, therefore, patient exposure to radiation.
Collapse
|
6
|
Covington MF, Koppula BR, Fine GC, Salem AE, Wiggins RH, Hoffman JM, Morton KA. PET-CT in Clinical Adult Oncology: II. Primary Thoracic and Breast Malignancies. Cancers (Basel) 2022; 14:cancers14112689. [PMID: 35681669 PMCID: PMC9179296 DOI: 10.3390/cancers14112689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 05/20/2022] [Accepted: 05/26/2022] [Indexed: 12/24/2022] Open
Abstract
Simple Summary Positron emission tomography (PET), typically combined with computed tomography (CT), has become a critical advanced imaging technique in oncology. With PET-CT, a radioactive molecule (radiotracer) is injected in the bloodstream and localizes to sites of tumor because of specific cellular features of the tumor that accumulate the targeting radiotracer. The CT scan, performed at the same time, provides information to facilitate assessment of the amount of radioactivity from deep or dense structures, and to provide detailed anatomic information. PET-CT has a variety of applications in oncology, including staging, therapeutic response assessment, restaging, and surveillance. This series of six review articles provides an overview of the value, applications, and imaging and interpretive strategies of PET-CT in the more common adult malignancies. The second article in this series addresses the use of PET-CT in breast cancer and other primary thoracic malignancies. Abstract Positron emission tomography combined with x-ray computed tomography (PET-CT) is an advanced imaging modality with oncologic applications that include staging, therapy assessment, restaging, and surveillance. This six-part series of review articles provides practical information to providers and imaging professionals regarding the best use of PET-CT for the more common adult malignancies. The second article of this series addresses primary thoracic malignancy and breast cancer. For primary thoracic malignancy, the focus will be on lung cancer, malignant pleural mesothelioma, thymoma, and thymic carcinoma, with an emphasis on the use of FDG PET-CT. For breast cancer, the various histologic subtypes will be addressed, and will include 18F fluorodeoxyglucose (FDG), recently Food and Drug Administration (FDA)-approved 18F-fluoroestradiol (FES), and 18F sodium fluoride (NaF). The pitfalls and nuances of PET-CT in breast and primary thoracic malignancies and the imaging features that distinguish between subcategories of these tumors are addressed. This review will serve as a resource for the appropriate roles and limitations of PET-CT in the clinical management of patients with breast and primary thoracic malignancies for healthcare professionals caring for adult patients with these cancers. It also serves as a practical guide for imaging providers, including radiologists, nuclear medicine physicians, and their trainees.
Collapse
Affiliation(s)
- Matthew F. Covington
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
| | - Bhasker R. Koppula
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
| | - Gabriel C. Fine
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
| | - Ahmed Ebada Salem
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
- Department of Radiodiagnosis and Intervention, Faculty of Medicine, Alexandria University, Alexandria 21526, Egypt
| | - Richard H. Wiggins
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
| | - John M. Hoffman
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
| | - Kathryn A. Morton
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT 84132, USA; (M.F.C.); (B.R.K.); (G.C.F.); (A.E.S.); (R.H.W.); (J.M.H.)
- Intermountain Healthcare Hospitals, Summit Physician Specialists, Murray, UT 84123, USA
- Correspondence: ; Tel.: +1-801-581-7553
| |
Collapse
|
7
|
Galati F, Moffa G, Pediconi F. Breast imaging: Beyond the detection. Eur J Radiol 2021; 146:110051. [PMID: 34864426 DOI: 10.1016/j.ejrad.2021.110051] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 07/23/2021] [Accepted: 11/15/2021] [Indexed: 12/23/2022]
Abstract
Breast cancer is a heterogeneous disease nowadays, including different biological subtypes with a variety of possible treatments, which aim to achieve the best outcome in terms of response to therapy and overall survival. In recent years breast imaging has evolved considerably, and the ultimate goal is to predict these strong phenotypic differences noninvasively. Indeed, breast cancer multiparametric studies can highlight not only qualitative imaging parameters, as the presence/absence of a likely malignant finding, but also quantitative parameters, suggesting clinical-pathological features through the evaluation of imaging biomarkers. A further step has been the introduction of artificial intelligence and in particular radiogenomics, that investigates the relationship between breast cancer imaging characteristics and tumor molecular, genomic and proliferation features. In this review, we discuss the main techniques currently in use for breast imaging, their respective fields of use and their technological and diagnostic innovations.
Collapse
Affiliation(s)
- Francesca Galati
- Department of Radiological, Oncological and Pathological Sciences, "Sapienza" - University of Rome, Viale Regina Elena, 324, 00161 Rome, Italy.
| | - Giuliana Moffa
- Department of Radiological, Oncological and Pathological Sciences, "Sapienza" - University of Rome, Viale Regina Elena, 324, 00161 Rome, Italy
| | - Federica Pediconi
- Department of Radiological, Oncological and Pathological Sciences, "Sapienza" - University of Rome, Viale Regina Elena, 324, 00161 Rome, Italy.
| |
Collapse
|
8
|
Park CKS, Bax JS, Gardi L, Knull E, Fenster A. Development of a mechatronic guidance system for targeted ultrasound-guided biopsy under high-resolution positron emission mammography localization. Med Phys 2021; 48:1859-1873. [PMID: 33577113 DOI: 10.1002/mp.14768] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 01/20/2021] [Accepted: 02/05/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Image-guided needle biopsy of small, detectable lesions is crucial for early-stage diagnosis, treatment planning, and management of breast cancer. High-resolution positron emission mammography (PEM) is a dedicated functional imaging modality that can detect breast cancer independent of breast tissue density, but anatomical context and real-time needle visualization are not yet available to guide biopsy. We propose a mechatronic guidance system integrating an ultrasound (US)-guided core-needle biopsy (CNB) with high-resolution PEM localization to improve the spatial sampling of breast lesions. This paper presents the benchtop testing and phantom studies to evaluate the accuracy of the system and its constituent components for targeted PEM-US-guided biopsy under simulated high-resolution PEM localization. METHODS A mechatronic guidance system was developed to operate with the Radialis PEM system and a conventional US system. The system includes a user-operated guidance arm and end-effector biopsy device, integrating a US transducer and CNB gun, with its needle focused on a remote center of motion (RCM). Custom software modules were developed to track, display, and guide the end-effector biopsy device. Registration of the mechatronic guidance system to a simulated PEM detector plate was performed using a landmark-based method. Testing was performed with fiducials positioned in the peripheral and central regions of the simulated detector plate and registration error was quantified. Breast phantom experiments were performed under ideal detection and localization to evaluate for bias in the end-effector biopsy device. The accuracy of the complete mechatronic guidance system to perform targeted breast biopsy was assessed using breast phantoms with simulated lesions. Three-dimensional positioning error was quantified, and principal component analysis assessed for directional trends in 3D space within 95% prediction intervals. Targeted breast biopsies with test phantoms were performed and an overall in-plane needle targeting error was quantified. RESULTS The mean registration errors were 0.63 mm (N = 44) and 0.73 mm (N = 72) in the peripheral and central regions of the simulated PEM detector plate, respectively. A 3D 95% prediction ellipsoid shows an error volume <2.0 mm in diameter, centered on the mean registration error. Under ideal detection and localization, targets <1.0 mm in diameter can be sampled with 95% confidence. The complete mechatronic guidance system was able to successfully spatially sample simulated breast lesions, 4 mm and 6 mm in diameter and height (N = 20) in known 3D positions in the PEM image coordinate space. The 3D positioning error was 0.85 mm (N = 20) with 0.64 mm in-plane and 0.44 mm cross-plane component errors. Targeted breast biopsies resulted in a mean in-plane needle targeting error of 1.08 mm (N = 15) allowing for targets 1.32 mm in radius to be sampled with 95% confidence. CONCLUSIONS We demonstrated the utility of our mechatronic guidance system for targeted breast biopsy under high-resolution PEM localization. Breast phantom studies showed the ability to accurately guide, position, and target breast lesions with the accuracy to spatially sample targets <3.0 mm in diameter with 95% confidence. Future work will integrate the developed system with the Radialis PEM system toward combined PEM-US-guided breast biopsy.
Collapse
Affiliation(s)
- Claire Keun Sun Park
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, N6A 3K7, Canada.,Imaging Research Laboratories, Robarts Research Institute, London, Ontario, N6A 5B7, Canada
| | - Jeffrey Scott Bax
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, N6A 5B7, Canada
| | - Lori Gardi
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, N6A 5B7, Canada
| | - Eric Knull
- Imaging Research Laboratories, Robarts Research Institute, London, Ontario, N6A 5B7, Canada.,School of Biomedical Engineering, Faculty of Engineering, Western University, London, Ontario, N6A 3K7, Canada
| | - Aaron Fenster
- Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, N6A 3K7, Canada.,Imaging Research Laboratories, Robarts Research Institute, London, Ontario, N6A 5B7, Canada.,School of Biomedical Engineering, Faculty of Engineering, Western University, London, Ontario, N6A 3K7, Canada
| |
Collapse
|
9
|
Molecular Breast Cancer Imaging in the Era of Precision Medicine. AJR Am J Roentgenol 2020; 215:1512-1519. [DOI: 10.2214/ajr.20.22883] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
10
|
Characterisation of MRI Indeterminate Breast Lesions Using Dedicated Breast PET and Prone FDG PET-CT in Patients with Breast Cancer—A Proof-of-Concept Study. J Pers Med 2020; 10:jpm10040148. [PMID: 32992995 PMCID: PMC7712852 DOI: 10.3390/jpm10040148] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Revised: 09/17/2020] [Accepted: 09/21/2020] [Indexed: 01/18/2023] Open
Abstract
Magnetic resonance imaging (MRI) in patients with breast cancer to assess extent of disease or multifocal disease can demonstrate indeterminate lesions requiring second-look ultrasound and ultrasound or MRI-guided biopsies. Prone positron emission tomography-computed tomography (PET-CT) is a dedicated acquisition performed with a breast-supporting device on a standard PET-CT scanner. The MAMmography with Molecular Imaging (MAMMI, Oncovision, Valencia, Spain) PET system (PET-MAMMI) is a true tomographic ring scanner for the breast. We investigated if PET-MAMMI and prone PET-CT were able to characterise these MRI- indeterminate lesions further. A total of 10 patients with breast cancer and indeterminate lesions on breast MRI were included. Patients underwent prone PET-MAMMI and prone PET-CT after injection of FDG subsequently on the same day. Patients then resumed their normal pathway, with the clinicians blinded to the results of the PET-MAMMI and prone PET-CT. Of the MRI-indeterminate lesions, eight were histopathologically proven to be malignant and two were benign. PET-MAMMI and prone PET-CT only were able to demonstrate increased FDG uptake in 1/8 and 0/8 of the MRI-indeterminate malignant lesions, respectively. Of the MRI-indeterminate benign lesions, both PET-MAMMI and prone PET-CT demonstrated avidity in 1/2 of these lesions. Our findings do not support the use of PET-MAMMI to characterise indeterminate breast MRI lesions requiring a second look ultrasound.
Collapse
|
11
|
Wei S, Vaska P. Evaluation of quantitative, efficient image reconstruction for VersaPET, a compact PET system. Med Phys 2020; 47:2852-2868. [PMID: 32219853 DOI: 10.1002/mp.14158] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 03/13/2020] [Accepted: 03/13/2020] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Previously we developed a high-resolution positron emission tomography (PET) system-VersaPET-characterized by a block geometry with relatively large axial and transaxial interblock gaps and a compact geometry susceptible to parallax blurring effects. In this work, we report the qualitative and quantitative evaluation of a graphic processing unit (GPU)-accelerated maximum-likelihood by expectation-maximization (MLEM) image reconstruction framework for VersaPET which features accurate system geometry and projection space point-spread-function (PSF) modeling. METHODS We combined the ray-tracing module from software for tomographic image reconstruction (STIR), an open-source PET image reconstruction package, with VersaPET's exact block geometry for the geometric system matrix. Point-spread-function modeling of crystal penetration and scattering was achieved by a custom Monte-Carlo simulation for projection space blurring in all dimensions. We also parallelized the reconstruction in GPU taking advantage of the system's symmetry for PSF computation. To investigate the effects of PSF width, we generated and studied multiple kernels between one that reflects the true LYSO density in the MC simulation and another that reflects geometry only (no PSF). GATE simulations of hot and cold-sphere phantoms with spheres of different sizes, real microDerenzo phantom, and human blood vessel data were used to characterize the quantitative and qualitative performances of the reconstruction. RESULTS Reconstruction with an accurate system geometry effectively improved image quality compared to STIR (version 3.0) which assumes an idealized system geometry. Reconstructions of GATE-simulated hot-sphere phantom data showed that all PSF kernels achieved superior performance in contrast recovery and bias reduction compared to using no PSF, but may introduce edge artifact and lumped background noise pattern depending on the width of PSF kernels. Cold-sphere phantom simulation results also indicated improvement in contrast recovery and quantification with PSF modeling (compared to no PSF) for 5 and 10 mm cold spheres. Real microDerenzo phantom images with the PSF kernel that reflects the true LYSO density showed degraded resolving power of small sectors that could be resolved more clearly by underestimated PSF kernels, which is consistent with recent literature despite differences in scanner geometries and in approaches to system model estimation. The human vessel results resemble those of the hot-sphere phantom simulation with the PSF kernel that reflects the true LYSO density achieving the highest peak in the time activity curve (TAC) and similar lumped noise pattern. CONCLUSIONS We fully evaluated a practical MLEM reconstruction framework that we developed for VersaPET in terms of qualitative and quantitative performance. Different PSF kernels may be adopted for improving the results of specific imaging tasks but the underlying reasons for the variation in optimal kernel for the real and simulation studies requires further study.
Collapse
Affiliation(s)
- Shouyi Wei
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, NY, 11794, USA
| | - Paul Vaska
- Departments of Biomedical Engineering and Radiology, Renaissance School of Medicine at Stony Brook University, Stony Brook, NY, 11794, USA
| |
Collapse
|