Lodoso-Torrecilla I, Konka J, Kreuzer M, Jimenez-Pique E, Espanol M, Ginebra MP. Quality assessment of regenerated bone in intraosseous and intramuscular scaffolds by spectroscopy and nanoindentation. BIOMATERIALS ADVANCES 2024; 164:213982. [PMID: 39098081 DOI: 10.1016/j.bioadv.2024.213982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 07/12/2024] [Accepted: 07/31/2024] [Indexed: 08/06/2024]
Abstract
The efficiency of synthetic bone grafts can be evaluated either in osseous sites, to analyze osteoconduction or ectopically, in intramuscular or subcutaneous sites, to assess osteoinduction. Bone regeneration is usually evaluated in terms of the presence and quantity of newly formed bone, but little information is normally provided on the quality of this bone. Here, we propose a novel approach to evaluate bone quality by the combined use of spectroscopy techniques and nanoindentation. Calcium phosphate scaffolds with different architectures, either foamed or 3D-printed, that were implanted in osseous or intramuscular defects in Beagle dogs for 6 or 12 weeks were analyzed. ATR-FTIR and Raman spectroscopy were performed, and mineral-to-matrix ratio, crystallinity, and mineral and collagen maturity were calculated and mapped for the newly regenerated bone and the mature cortical bone from the same specimen. For all the parameters studied, the newly-formed bone showed lower values than the mature host bone. Hardness and elastic modulus were determined by nanoindentation and, in line with what was observed by spectroscopy, lower values were observed in the regenerated bone than in the cortical bone. While, as expected, all techniques pointed to an increase in the maturity of the newly-formed bone between 6 and 12 weeks, the bone found in the intramuscular samples after 12 weeks presented lower mineralization than the intraosseous counterparts. Moreover, scaffold architecture also played a role in bone maturity, with the foamed scaffolds showing higher mineralization and crystallinity than the 3D-printed scaffolds after 12 weeks.
Collapse
Affiliation(s)
- Irene Lodoso-Torrecilla
- Department of Materials Science and Engineering, Group of Biomaterials, Biomechanics and Tissue Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Barcelona Research Centre in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain
| | - Joanna Konka
- Department of Materials Science and Engineering, Group of Biomaterials, Biomechanics and Tissue Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Barcelona Research Centre in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain
| | - Martin Kreuzer
- CELLS-ALBA, Carrer de la Llum 2-26, 08290, Cerdanyola del Valles, Barcelona, Spain
| | - Emilio Jimenez-Pique
- Barcelona Research Centre in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Department of Materials Science and Engineering, CIEFMA Group, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain
| | - Montserrat Espanol
- Department of Materials Science and Engineering, Group of Biomaterials, Biomechanics and Tissue Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Barcelona Research Centre in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Centro de Investigación Biomédica en Red-Bioingeniería, Biomedicina y Nanomedicina (CIBER-BBN), Spain
| | - Maria-Pau Ginebra
- Department of Materials Science and Engineering, Group of Biomaterials, Biomechanics and Tissue Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Barcelona Research Centre in Multiscale Science and Engineering, Universitat Politècnica de Catalunya (UPC), Barcelona, Spain; Centro de Investigación Biomédica en Red-Bioingeniería, Biomedicina y Nanomedicina (CIBER-BBN), Spain; Institute for Bioengineering of Catalonia (IBEC), Barcelona Institute of Science and Technology, Carrer Baldiri Reixac 10-12, 08028 Barcelona, Spain.
| |
Collapse
|
2
|
Gao X, Fraulob M, Haïat G. Biomechanical behaviours of the bone-implant interface: a review. J R Soc Interface 2019; 16:20190259. [PMID: 31362615 PMCID: PMC6685012 DOI: 10.1098/rsif.2019.0259] [Citation(s) in RCA: 97] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/01/2019] [Indexed: 01/09/2023] Open
Abstract
In recent decades, cementless implants have been widely used in clinical practice to replace missing organs, to replace damaged or missing bone tissue or to restore joint functionality. However, there remain risks of failure which may have dramatic consequences. The success of an implant depends on its stability, which is determined by the biomechanical properties of the bone-implant interface (BII). The aim of this review article is to provide more insight on the current state of the art concerning the evolution of the biomechanical properties of the BII as a function of the implant's environment. The main characteristics of the BII and the determinants of implant stability are first introduced. Then, the different mechanical methods that have been employed to derive the macroscopic properties of the BII will be described. The experimental multi-modality approaches used to determine the microscopic biomechanical properties of periprosthetic newly formed bone tissue are also reviewed. Eventually, the influence of the implant's properties, in terms of both surface properties and biomaterials, is investigated. A better understanding of the phenomena occurring at the BII will lead to (i) medical devices that help surgeons to determine an implant's stability and (ii) an improvement in the quality of implants.
Collapse
Affiliation(s)
- Xing Gao
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
- Research Centre for Medical Robotics and Minimally Invasive Surgical Devices, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| |
Collapse
|
3
|
Akilbekova D, Ogay V, Yakupov T, Sarsenova M, Umbayev B, Nurakhmetov A, Tazhin K, Yakovlev VV, Utegulov ZN. Brillouin spectroscopy and radiography for assessment of viscoelastic and regenerative properties of mammalian bones. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-11. [PMID: 30264554 PMCID: PMC8357194 DOI: 10.1117/1.jbo.23.9.097004] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2018] [Accepted: 08/15/2018] [Indexed: 05/20/2023]
Abstract
Biomechanical properties of mammalian bones, such as strength, toughness, and plasticity, are essential for understanding how microscopic-scale mechanical features can link to macroscale bones' strength and fracture resistance. We employ Brillouin light scattering (BLS) microspectroscopy for local assessment of elastic properties of bones under compression and the efficacy of the tissue engineering approach based on heparin-conjugated fibrin (HCF) hydrogels, bone morphogenic proteins, and osteogenic stem cells in the regeneration of the bone tissues. BLS is noninvasive and label-free modality for probing viscoelastic properties of tissues that can give information on structure-function properties of normal and pathological tissues. Results showed that MCS and BPMs are critically important for regeneration of elastic and viscous properties, respectively, HCF gels containing combination of all factors had the best effect with complete defect regeneration at week nine after the implantation of bone grafts and that the bones with fully consolidated fractures have higher values of elastic moduli compared with defective bones.
Collapse
Affiliation(s)
- Dana Akilbekova
- Nazarbayev University, National Laboratory Astana, Astana, Kazakhstan
- Nazarbayev University, School of Engineering, Department of Chemical Engineering, Astana, Kazakhstan
- Address all correspondence to: Dana Akilbekova, E-mail: ; Zhandos N. Utegulov, E-mail:
| | - Vyacheslav Ogay
- National Center for Biotechnology, Stem Cell Laboratory, Astana, Kazakhstan
| | - Talgat Yakupov
- Nazarbayev University, Department of Physics, School of Science and Technology, Astana, Kazakhstan
| | - Madina Sarsenova
- National Center for Biotechnology, Stem Cell Laboratory, Astana, Kazakhstan
| | - Bauyrzhan Umbayev
- Nazarbayev University, National Laboratory Astana, Astana, Kazakhstan
| | - Asset Nurakhmetov
- Research Institute of Traumatology and Orthopedics, Astana, Kazakhstan
| | - Kairat Tazhin
- Research Institute of Traumatology and Orthopedics, Astana, Kazakhstan
| | - Vladislav V. Yakovlev
- Texas A&M University, Department of Biomedical Engineering and Department of Physics and Astronomy, College Station, Texas, United States
| | - Zhandos N. Utegulov
- Nazarbayev University, Department of Physics, School of Science and Technology, Astana, Kazakhstan
- Address all correspondence to: Dana Akilbekova, E-mail: ; Zhandos N. Utegulov, E-mail:
| |
Collapse
|
4
|
Anchieta RB, Guimarães MVM, Suzuki M, Tovar N, Bonfante EA, Atria P, Coelho PG. Nanomechanical Assessment of Bone Surrounding Implants Loaded for 3 Years in a Canine Experimental Model. J Oral Maxillofac Surg 2017; 76:71-79. [PMID: 28893541 DOI: 10.1016/j.joms.2017.08.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2017] [Revised: 08/09/2017] [Accepted: 08/09/2017] [Indexed: 11/17/2022]
Abstract
PURPOSE This work evaluated the nanomechanical properties of bone surrounding submerged and immediately loaded implants after 3 years in vivo. It was hypothesized that the nanomechanical properties of bone would markedly increase in immediately and functionally loaded implants compared with submerged implants. MATERIALS AND METHODS The second, third, and fourth right premolars and the first molar of 10 adult Doberman dogs were extracted. After 6 months, 4 implants were placed in 1 side of the mandible. The mesial implant received a cover screw and remained unloaded. The remaining 3 implants received fixed dental prostheses within 48 hours after surgery that remained in occlusal function for 3 years. After sacrifice, the bone was prepared for histologic and nanoindentation analysis. Nanoindentation was carried out under wet conditions on bone areas within the plateaus. Indentations (n = 30 per histologic section) were performed with a maximum load of 300 μN (loading rate, 60 μN per second) followed by a holding and unloading time of 10 and 2 seconds, respectively. Elastic modulus (E) and hardness (H) were computed in giga-pascals. The amount of bone-to-implant contact (BIC) also was evaluated. RESULTS The E and H values for cortical bone regions were higher than those for trabecular bone regardless of load condition, but this difference was not statistically significant (P > .05). The E and H values were higher for loaded implants than for submerged implants (P < .05) for cortical and trabecular bone. For the same load condition, the E and H values for cortical and trabecular bone were not statistically different (P > .05). The loaded and submerged implants presented BIC values (mean ± standard deviation) of 57.4 ± 12.1% and 62 ± 7.5%, respectively (P > .05). CONCLUSION The E and H values of bone surrounding dental implants, measured by nanoindentation, were higher for immediately loaded than for submerged implants.
Collapse
Affiliation(s)
- Rodolfo B Anchieta
- Assistant Professor, Centro Universitario do Norte Paulista (UNORP), São Jose do Rio Preto, SP, Brazil; Visiting Scholar, Department of Biomaterials and Biomimetics, New York University, New York, NY; Department of Restorative Denstistry, Araçatuba, Universidade Estadual Paulista (UNESP), SP, Brazil
| | | | - Marcelo Suzuki
- Associate Professor, Department of Prosthodontics and Operative Dentistry, Tufts University School of Dental Medicine, Boston, MA
| | - Nick Tovar
- Adjunct Assistant Professor, Department of Biomaterials and Biomimetics, New York University, New York, NY
| | - Estevam A Bonfante
- Assistant Professor, Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil.
| | - Pablo Atria
- Research Professor, Universidad de los Andes, Santiago, Chile
| | - Paulo G Coelho
- Professor, Department of Biomaterials and Biomimetics, New York University, New York, NY; Mechanical and Aerospace Engineering, NYU Tandon School of Engineering; and Hansjörg Wyss Department of Plastic Surgery, NYU Langone Medical Center, New York, NY
| |
Collapse
|
5
|
Halldin A, Ander M, Jacobsson M, Hansson S. Simulation of the mechanical interlocking capacity of a rough bone implant surface during healing. Biomed Eng Online 2015; 14:45. [PMID: 25994839 PMCID: PMC4440247 DOI: 10.1186/s12938-015-0038-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2014] [Accepted: 04/16/2015] [Indexed: 11/16/2022] Open
Abstract
Background When an implant is inserted in the bone the healing process starts to osseointegrate the implant by creating new bone that interlocks with the implant. Biomechanical interlocking capacity is commonly evaluated in in vivo experiments. It would be beneficial to find a numerical method to evaluate the interlocking capacity of different surface structures with bone. In the present study, the theoretical interlocking capacity of three different surfaces after different healing times was evaluated by the means of explicit finite element analysis. Methods The surface topographies of the three surfaces were measured with interferometry and were used to construct a 3D bone-implant model. The implant was subjected to a displacement until failure of the bone-to-implant interface and the maximum force represents the interlocking capacity. Results The simulated ratios (test/control) seem to agree with the in vivo ratios of Halldin et al. for longer healing times. However the absolute removal torque values are underestimated and do not reach the biomechanical performance found in the study by Halldin et al. which might be a result of unknown mechanical properties of the interface. Conclusion Finite element analysis is a promising method that might be used prior to an in vivo study to compare the load bearing capacity of the bone-to-implant interface of two surface topographies at longer healing times.
Collapse
Affiliation(s)
- Anders Halldin
- Department of Prosthodontics, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden. .,DENTSPLY Implants, Box 14, 43121, Mölndal, Sweden.
| | - Mats Ander
- Department of Applied Mechanics, Chalmers University of Technology, 41296, Gothenburg, Sweden.
| | - Magnus Jacobsson
- Department of Prosthodontics, Faculty of Odontology, Malmö University, 205 06, Malmö, Sweden.
| | - Stig Hansson
- DENTSPLY Implants, Box 14, 43121, Mölndal, Sweden.
| |
Collapse
|
6
|
Matsukawa M, Tsubota R, Kawabe M, Fukui K. Application of a micro-Brillouin scattering technique to characterize bone in the GHz range. ULTRASONICS 2014; 54:1155-61. [PMID: 24139301 DOI: 10.1016/j.ultras.2013.09.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2013] [Revised: 08/17/2013] [Accepted: 09/01/2013] [Indexed: 05/20/2023]
Abstract
The evaluation of elastic properties of bone matrix has been investigated using several techniques such as nanoindentation and scanning acoustic microscopy (SAM). These techniques make use of good spatial resolution, which can prevent effects due to microstructures at the level of several hundreds of microns. In this paper, micro-Brillouin scattering (μ-BR) is introduced as another possible technique to characterize the elastic properties of bone. This technique is well known as a non-contact and non-destructive method to evaluate viscoelastic properties of transparent materials in the GHz range. Using thin, translucent bone specimens with thicknesses of around 100 μm, and the reflection induced optical geometry, ultrasonic wave velocities in the GHz range were obtained. Because this technique optically measures thermal phonons in the specimen, we can easily measure in-plane anisotropy of wave velocities by rotating the specimen. In a single trabecula, the site matched data between SAM and μ-BR showed good correlation, revealing the applicability of this technique to characterize material properties of bone. Some recent results on the anisotropy in a trabecula and the elasticity evaluation of newly and matured bones are also introduced.
Collapse
Affiliation(s)
- Mami Matsukawa
- Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan.
| | - Ryo Tsubota
- Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan
| | - Masahiko Kawabe
- Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan
| | - Kenji Fukui
- Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan
| |
Collapse
|
7
|
Nanomechanical properties and molecular structures of in vitro mineralized tissues on anodically-oxidized titanium surfaces. NANOMEDICINE-NANOTECHNOLOGY BIOLOGY AND MEDICINE 2014; 10:629-37. [DOI: 10.1016/j.nano.2013.09.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2013] [Revised: 08/12/2013] [Accepted: 09/26/2013] [Indexed: 12/23/2022]
|
8
|
Grandfield K, Palmquist A, Engqvist H, Thomsen P. Resolving the CaP-bone interface: a review of discoveries with light and electron microscopy. BIOMATTER 2014; 2:15-23. [PMID: 23507782 DOI: 10.4161/biom.20062] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
It has long been known that the interfacial relationship between synthetic materials and tissue is influential in the success of implant materials. Instability at the implant interface has been shown, in some cases, to lead to complete implant failure. Bioceramics, and in particular calcium phosphates, form a large fraction of the implantable devices on the market today due to the biocompatibility they exhibit in contact with bone and tooth-like tissues. The characterization of such bioceramic-tissue interfaces has played a crucial role in understanding the behavior of bioceramics in vivo. In this review, we shed light on the preparation methods, technological approaches and key advances in resolving the interface between calcium phosphate bioceramics and bone, and share a future outlook on this field.
Collapse
Affiliation(s)
- Kathryn Grandfield
- Department of Engineering Sciences, Ångström Laboratory, Uppsala University, Uppsala, Sweden.
| | | | | | | |
Collapse
|
9
|
Iijima M, Nakagaki S, Yasuda Y, Handa K, Koike T, Muguruma T, Saito T, Mizoguchi I. Effect of immediate loading on the biomechanical properties of bone surrounding the miniscrew implants. Eur J Orthod 2012; 35:577-82. [PMID: 22952154 DOI: 10.1093/ejo/cjs055] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The aim of this study was to investigate the effect of immediate loading on the biomechanical properties of bone surrounding a miniscrew implant. Forty titanium alloy miniscrew implants were placed on the buccal side of the maxillae and mandibles in four beagle dogs. Twelve pairs of miniscrew implants were immediately loaded with approximately 150 g of continuous force using nickel-titanium coil springs and the remaining 16 implants were left unloaded for 8 weeks. Nanoindentation testing was performed (peak load 10 mN) and the hardness and elastic modulus were calculated. Two series of indentations (in cortical and trabecular bone) for both the compression and tension sides were made. For each site, five indentations were placed approximately 25 μm from the implant-bone interface and 250 μm from the screw thread. The mean hardness and elastic modulus were generally higher in mandibles than maxillae and were higher in cortical bone than in trabecular bone. The trabecular bone near the implant-bone interface on the compression side was significantly harder than that at other locations in trabecular bone. In conclusion, this is the first study that has investigated the biomechanical properties of bone surrounding a miniscrew implant under immediate loading using nanoindentation testing. The mechanical properties of bone surrounding a miniscrew implant may be influenced by immediate loading.
Collapse
Affiliation(s)
- Masahiro Iijima
- Division of Orthodontics and Dentofacial Orthopedics, Department of Oral Growth and Development, School of Dentistry, Health Sciences University of Hokkaido, Ishikari-Tobetsu
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Mathieu V, Fukui K, Matsukawa M, Kawabe M, Vayron R, Soffer E, Anagnostou F, Haiat G. Micro-Brillouin scattering measurements in mature and newly formed bone tissue surrounding an implant. J Biomech Eng 2011; 133:021006. [PMID: 21280878 DOI: 10.1115/1.4003131] [Citation(s) in RCA: 59] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
The evolution of implant stability in bone tissue remains difficult to assess because remodeling phenomena at the bone-implant interface are still poorly understood. The characterization of the biomechanical properties of newly formed bone tissue in the vicinity of implants at the microscopic scale is of importance in order to better understand the osseointegration process. The objective of this study is to investigate the potentiality of micro-Brillouin scattering techniques to differentiate mature and newly formed bone elastic properties following a multimodality approach using histological analysis. Coin-shaped Ti-6Al-4V implants were placed in vivo at a distance of 200 μm from rabbit tibia leveled cortical bone surface, leading to an initially empty cavity of 200 μm×4.4 mm. After 7 weeks of implantation, the bone samples were removed, fixed, dehydrated, embedded in methyl methacrylate, and sliced into 190 μm thick sections. Ultrasonic velocity measurements were performed using a micro-Brillouin scattering device within regions of interest (ROIs) of 10 μm diameter. The ROIs were located in newly formed bone tissue (within the 200 μm gap) and in mature bone tissue (in the cortical layer of the bone sample). The same section was then stained for histological analysis of the mineral content of the bone sample. The mean values of the ultrasonic velocities were equal to 4.97×10(-3) m/s in newly formed bone tissue and 5.31×10(-3) m/s in mature bone. Analysis of variance (p=2.42×10(-4)) tests revealed significant differences between the two groups of measurements. The standard deviation of the velocities was significantly higher in newly formed bone than in mature bone. Histological observations allow to confirm the accurate locations of the velocity measurements and showed a lower degree of mineralization in newly formed bone than in the mature cortical bone. The higher ultrasonic velocity measured in newly formed bone tissue compared with mature bone might be explained by the higher mineral content in mature bone, which was confirmed by histology. The heterogeneity of biomechanical properties of newly formed bone at the micrometer scale may explain the higher standard deviation of velocity measurements in newly formed bone compared with mature bone. The results demonstrate the feasibility of micro-Brillouin scattering technique to investigate the elastic properties of newly formed bone tissue.
Collapse
Affiliation(s)
- Vincent Mathieu
- Laboratoire de Biomécanique Biomatériau Ostéo Articulaire, CNRS, Université Paris 7, UMR CNRS 7052, 10 Avenue de Verdun, Paris 75010, France
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Zhao Y, Ovaert TC. Error Estimation of Nanoindentation Mechanical Properties Near a Dissimilar Interface via Finite Element Analysis and Analytical Solution Methods. JOURNAL OF MATERIALS RESEARCH 2010; 25:2308-2316. [PMID: 21528107 PMCID: PMC3082209 DOI: 10.1557/jmr.2010.0295] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Nanoindentation methods are well suited for probing the mechanical properties of a heterogeneous surface, since the probe size and contact volumes are small and localized. However, the nanoindentation method may introduce errors in the computed mechanical properties when indenting near the interface between two materials having significantly different mechanical properties. Here we examine the case where a soft material is loaded in close proximity to an interface of higher modulus, such as the case when indenting bone near a metallic implant. Results are derived from both an approximate analytical quarter-space solution and a finite element model, and used to estimate the error in indentation-determined elastic modulus as a function of the distance from the apex of contact to the dissimilar interface, for both Berkovich and spherical indenter geometries. Sample data reveal the potential errors in mechanical property determination that can occur when indenting near an interface having higher stiffness, or when characterizing strongly heterogeneous materials. The results suggest that caution should be used when interpreting results in the near-interfacial region.
Collapse
|
12
|
Baker MI, Eberhardt AW, Martin DM, McGwin G, Lemons JE. Bone properties surrounding hydroxyapatite-coated custom osseous integrated dental implants. J Biomed Mater Res B Appl Biomater 2010; 95:218-24. [DOI: 10.1002/jbm.b.31693] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
13
|
Lim JI, Lee YK. Oleic acid-added embedding medium for histological analysis of hard tissue. Microsc Res Tech 2009; 72:766-71. [DOI: 10.1002/jemt.20738] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
14
|
Zhao L, Wu Z, Zhang Y. Low-magnitude mechanical vibration may be applied clinically to promote dental implant osseointegration. Med Hypotheses 2009; 72:451-2. [DOI: 10.1016/j.mehy.2008.10.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2008] [Revised: 09/22/2008] [Accepted: 10/02/2008] [Indexed: 01/27/2023]
|
15
|
Investigation of bone inelastic response in interaction phenomena with dental implants. Dent Mater 2008; 24:561-9. [DOI: 10.1016/j.dental.2007.11.024] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2007] [Accepted: 11/29/2007] [Indexed: 11/21/2022]
|