• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4624131)   Today's Articles (6040)   Subscriber (49410)
For: Schüller M, Drobetz H, Redl H, Tschegg E. Analysis of the fatigue behaviour characterized by stiffness and permanent deformation for different distal volar radius compression plates. Materials Science and Engineering: C 2009. [DOI: 10.1016/j.msec.2009.07.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Number Cited by Other Article(s)
1
Wei G, Niu X, Li Y, Chang T, Zhang J, Wang H, Li X, He Y, Wang R, Tian F, Xu Y. Biomechanical analysis of internal fixation system stability for tibial plateau fractures. Front Bioeng Biotechnol 2023;11:1199944. [PMID: 37388773 PMCID: PMC10303893 DOI: 10.3389/fbioe.2023.1199944] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 06/06/2023] [Indexed: 07/01/2023]  Open
2
Xie S, Manda K, Pankaj P. Effect of loading frequency on deformations at the bone-implant interface. Proc Inst Mech Eng H 2019;233:1219-1225. [PMID: 31560261 DOI: 10.1177/0954411919877970] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
3
Okazaki Y, Gotoh E, Mori J. Strength⁻Durability Correlation of Osteosynthesis Devices Made by 3D Layer Manufacturing. MATERIALS 2019;12:ma12030436. [PMID: 30708995 PMCID: PMC6385053 DOI: 10.3390/ma12030436] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/25/2018] [Revised: 01/29/2019] [Accepted: 01/29/2019] [Indexed: 11/16/2022]
4
Shaat M. Reporting the Fatigue Life of 316L Stainless Steel Locking Compression Plate Implants: The Role of the Femoral and Tibial Biomechanics During the Gait. J Biomech Eng 2017;139:2648718. [DOI: 10.1115/1.4037561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Indexed: 01/02/2023]
5
Meischel M, Eichler J, Martinelli E, Karr U, Weigel J, Schmöller G, Tschegg E, Fischerauer S, Weinberg A, Stanzl-Tschegg S. Adhesive strength of bone-implant interfaces and in-vivo degradation of PHB composites for load-bearing applications. J Mech Behav Biomed Mater 2016;53:104-118. [DOI: 10.1016/j.jmbbm.2015.08.004] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Revised: 07/28/2015] [Accepted: 08/04/2015] [Indexed: 11/26/2022]
6
Can the use of variable-angle volar locking plates compensate for suboptimal plate positioning in unstable distal radius fractures? A biomechanical study. J Orthop Trauma 2015;29:e1-6. [PMID: 24786734 DOI: 10.1097/bot.0000000000000146] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
7
Berger L, Fischerauer S, Weiß B, Celarek A, Castellani C, Weinberg AM, Tschegg E. Unlocked and locked elastic stable intramedullary nailing in an ovine tibia fracture model: A biomechanical study. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014;40:267-74. [DOI: 10.1016/j.msec.2014.04.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2013] [Revised: 03/11/2014] [Accepted: 04/03/2014] [Indexed: 11/25/2022]
8
Drobetz H, Weninger P, Grant C, Heal C, Muller R, Schuetz M, Pham M, Steck R. More is not necessarily better. A biomechanical study on distal screw numbers in volar locking distal radius plates. Injury 2013;44:535-9. [PMID: 23127726 DOI: 10.1016/j.injury.2012.10.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/16/2012] [Revised: 10/11/2012] [Accepted: 10/14/2012] [Indexed: 02/02/2023]
9
Biomechanical analysis of a synthetic femur spiral fracture model: Influence of different materials on the stiffness in flexible intramedullary nailing. Clin Biomech (Bristol, Avon) 2011;26:592-7. [PMID: 21345557 DOI: 10.1016/j.clinbiomech.2011.01.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2010] [Revised: 01/26/2011] [Accepted: 01/27/2011] [Indexed: 02/07/2023]
10
Drobetz H, Schueller M, Tschegg EK, Heal C, Redl H, Muller R. Influence of screw diameter and number on reduction loss after plating of distal radius fractures. ANZ J Surg 2010;81:46-51. [PMID: 21299798 DOI: 10.1111/j.1445-2197.2010.05479.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA