1
|
Yi CC, Kim J, Jung J, Jo D, Kim JH. Biomechanical analysis using finite element analysis of orbital floor fractures reproduced in a realistic experimental environment with an anatomical model. Front Bioeng Biotechnol 2024; 12:1354944. [PMID: 38774815 PMCID: PMC11106499 DOI: 10.3389/fbioe.2024.1354944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 04/15/2024] [Indexed: 05/24/2024] Open
Abstract
Introduction: In this study, we attempted to demonstrate the actual process of orbital floor fracture visually and computationally in anatomically reconstructed structures and to investigate them using finite element analysis. Methods: A finite element model of the skull and cervical vertebrae was reconstructed from computed tomography data, and an eyeball surrounded by extraocular adipose was modeled in the orbital cavity. Three-dimensional volume mesh was generated using 173,894 of the 4-node hexahedral solid elements. Results: For the cases where the impactor hit the infraorbital foramen, buckling occurred at the orbital bone as a result of the compressive force, and the von Mises stress exceeded 150 MPa. The range of stress components included inferior orbital rim and orbital floor. For the cases where the impactor hit the eyeball first, the orbital bone experienced less stress and the range of stress components limited in orbital floor. The critical speeds for blowout fracture were 4 m/s and 6 m/s for buckling and hydraulic mechanism. Conclusion: Each mechanism has its own fracture inducing energy and its transmission process, type of force causing the fracture, and fracture pattern. It is possible to determine the mechanism of the fracture based on whether an orbital rim fracture is present.
Collapse
Affiliation(s)
- Changryul Claud Yi
- Department of Plastic and Reconstructive Surgery, Pusan National University School of Medicine, Busan, Republic of Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea
| | - Jaehoon Kim
- School of Mechanical Engineering, Pusan National University, Busan, Republic of Korea
| | - Jaebong Jung
- School of Mechanical Engineering, Pusan National University, Busan, Republic of Korea
| | - Deoksang Jo
- School of Mechanical Engineering, Pusan National University, Busan, Republic of Korea
| | - Ji Hoon Kim
- School of Mechanical Engineering, Pusan National University, Busan, Republic of Korea
| |
Collapse
|
2
|
Delplace V, Ortin-Martinez A, Tsai ELS, Amin AN, Wallace V, Shoichet MS. Controlled release strategy designed for intravitreal protein delivery to the retina. J Control Release 2019; 293:10-20. [DOI: 10.1016/j.jconrel.2018.11.012] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Revised: 11/05/2018] [Accepted: 11/09/2018] [Indexed: 12/25/2022]
|
3
|
Aloy MÁ, Adsuara JE, Cerdá-Durán P, Obergaulinger M, Esteve-Taboada JJ, Ferrer-Blasco T, Montés-Micó R. Estimation of the mechanical properties of the eye through the study of its vibrational modes. PLoS One 2017; 12:e0183892. [PMID: 28922351 PMCID: PMC5603173 DOI: 10.1371/journal.pone.0183892] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2016] [Accepted: 08/14/2017] [Indexed: 12/28/2022] Open
Abstract
Measuring the eye's mechanical properties in vivo and with minimally invasive techniques can be the key for individualized solutions to a number of eye pathologies. The development of such techniques largely relies on a computational modelling of the eyeball and, it optimally requires the synergic interplay between experimentation and numerical simulation. In Astrophysics and Geophysics the remote measurement of structural properties of the systems of their realm is performed on the basis of (helio-)seismic techniques. As a biomechanical system, the eyeball possesses normal vibrational modes encompassing rich information about its structure and mechanical properties. However, the integral analysis of the eyeball vibrational modes has not been performed yet. Here we develop a new finite difference method to compute both the spheroidal and, specially, the toroidal eigenfrequencies of the human eye. Using this numerical model, we show that the vibrational eigenfrequencies of the human eye fall in the interval 100 Hz-10 MHz. We find that compressible vibrational modes may release a trace on high frequency changes of the intraocular pressure, while incompressible normal modes could be registered analyzing the scattering pattern that the motions of the vitreous humour leave on the retina. Existing contact lenses with embebed devices operating at high sampling frequency could be used to register the microfluctuations of the eyeball shape we obtain. We advance that an inverse problem to obtain the mechanical properties of a given eye (e.g., Young's modulus, Poisson ratio) measuring its normal frequencies is doable. These measurements can be done using non-invasive techniques, opening very interesting perspectives to estimate the mechanical properties of eyes in vivo. Future research might relate various ocular pathologies with anomalies in measured vibrational frequencies of the eye.
Collapse
Affiliation(s)
- M. Á. Aloy
- Department of Astronomy and Astrophysics, University of Valencia, 46100 Burjassot, Spain
- * E-mail:
| | - J. E. Adsuara
- Department of Astronomy and Astrophysics, University of Valencia, 46100 Burjassot, Spain
| | - P. Cerdá-Durán
- Department of Astronomy and Astrophysics, University of Valencia, 46100 Burjassot, Spain
| | - M. Obergaulinger
- Department of Astronomy and Astrophysics, University of Valencia, 46100 Burjassot, Spain
| | - J. J. Esteve-Taboada
- Department of Optics and Optometry and Vision Sciences, University of Valencia, 46100 Burjassot, Spain
| | - T. Ferrer-Blasco
- Department of Optics and Optometry and Vision Sciences, University of Valencia, 46100 Burjassot, Spain
| | - R. Montés-Micó
- Department of Optics and Optometry and Vision Sciences, University of Valencia, 46100 Burjassot, Spain
| |
Collapse
|
4
|
Besner S, Scarcelli G, Pineda R, Yun SH. In Vivo Brillouin Analysis of the Aging Crystalline Lens. Invest Ophthalmol Vis Sci 2017; 57:5093-5100. [PMID: 27699407 PMCID: PMC5054731 DOI: 10.1167/iovs.16-20143] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
Purpose To analyze the age dependence of the longitudinal modulus of the crystalline lens in vivo using Brillouin scattering data in healthy subjects. Methods Brillouin scans were performed along the crystalline lens in 56 eyes from 30 healthy subjects aged from 19 to 63 years. Longitudinal elastic modulus was acquired along the sagittal axis of the lens with a transverse and axial resolution of 4 and 60 μm, respectively. The relative lens stiffness was computed, and correlations with age were analyzed. Results Brillouin axial profiles revealed nonuniform longitudinal modulus within the lens, increasing from a softer periphery toward a stiffer central plateau at all ages. The longitudinal modulus at the central plateau showed no age dependence in a range of 19 to 45 years and a slight decrease with age from 45 to 63 years. A significant intersubject variability was observed in an age-matched analysis. Importantly, the extent of the central stiff plateau region increased steadily over age from 19 to 63 years. The slope of change in Brillouin modulus in the peripheral regions were nearly age-invariant. Conclusions The adult human lens showed no measurable age-related increase in the peak longitudinal modulus. The expansion of the stiff central region of the lens is likely to be the major contributing factor to age-related lens stiffening. Brillouin microscopy may be useful in characterizing the crystalline lens for the optimization of surgical or pharmacological treatments aimed at restoring accommodative power.
Collapse
Affiliation(s)
- Sebastien Besner
- Wellman Center for Photomedicine, Massachusetts General Hospital, Cambridge, Massachusetts, United States 2Department of Dermatology, Harvard Medical School, Boston, Massachusetts, United States
| | - Giuliano Scarcelli
- Wellman Center for Photomedicine, Massachusetts General Hospital, Cambridge, Massachusetts, United States 2Department of Dermatology, Harvard Medical School, Boston, Massachusetts, United States 3Fischell Department of Bioengineering, University of Maryland, College Park, Maryland, United States
| | - Roberto Pineda
- Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, United States
| | - Seok-Hyun Yun
- Wellman Center for Photomedicine, Massachusetts General Hospital, Cambridge, Massachusetts, United States 2Department of Dermatology, Harvard Medical School, Boston, Massachusetts, United States 5Harvard-MIT Health Sciences and Technology, Cambridge, Massachusetts, United States
| |
Collapse
|
5
|
Ali M, Raghunathan V, Li JY, Murphy CJ, Thomasy SM. Biomechanical relationships between the corneal endothelium and Descemet's membrane. Exp Eye Res 2016; 152:57-70. [PMID: 27639516 DOI: 10.1016/j.exer.2016.09.004] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 09/13/2016] [Indexed: 12/28/2022]
Abstract
The posterior face of the cornea consists of the corneal endothelium, a monolayer of cuboidal cells that secrete and attach to Descemet's membrane, an exaggerated basement membrane. Dysfunction of the endothelium compromises the barrier and pump functions of this layer that maintain corneal deturgesence. A large number of corneal endothelial dystrophies feature irregularities in Descemet's membrane, suggesting that cells create and respond to the biophysical signals offered by their underlying matrix. This review provides an overview of the bidirectional relationship between Descemet's membrane and the corneal endothelium. Several experimental methods have characterized a richly topographic and compliant biophysical microenvironment presented by the posterior surface of Descemet's membrane, as well as the ultrastructure and composition of the membrane as it builds during a lifetime. We highlight the signaling pathways involved in the mechanotransduction of biophysical cues that influence cell behavior. We present the specific example of Fuchs' corneal endothelial dystrophy as a condition in which a dysregulated Descemet's membrane may influence the progression of disease. Finally, we discuss some disease models and regenerative strategies that may facilitate improved treatments for corneal dystrophies.
Collapse
Affiliation(s)
- Maryam Ali
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, 95616, USA.
| | - VijayKrishna Raghunathan
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, TX, 77204, USA.
| | - Jennifer Y Li
- Department of Ophthalmology & Vision Science, School of Medicine, UC Davis Medical Center, Sacramento, CA, 95817, USA.
| | - Christopher J Murphy
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, 95616, USA; Department of Ophthalmology & Vision Science, School of Medicine, UC Davis Medical Center, Sacramento, CA, 95817, USA.
| | - Sara M Thomasy
- Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, CA, 95616, USA.
| |
Collapse
|
6
|
Baino F, Vitale-Brovarone C. Bioceramics in ophthalmology. Acta Biomater 2014; 10:3372-97. [PMID: 24879312 DOI: 10.1016/j.actbio.2014.05.017] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Revised: 05/15/2014] [Accepted: 05/16/2014] [Indexed: 12/21/2022]
Abstract
The benefits of ceramics in biomedical applications have been universally appreciated as they exhibit an extraordinarily broad set of physico-chemical, mechanical and biological properties which can be properly tailored by acting on their composition, porosity and surface texture to increase their versatility and suitability for targeted healthcare applications. Bioceramics have traditionally been used for the repair of hard tissues, such as bone and teeth, mainly due to their suitable strength for load-bearing applications, wear resistance (especially alumina, zirconia and composites thereof) and, in some cases, bone-bonding ability (calcium orthophosphates and bioactive glasses). Bioceramics have been also applied in other medical areas, like ophthalmic surgery; although their use in such a context has been scientifically documented since the late 1700s, the potential and importance of ceramic ocular implants still seem to be underestimated and an exhaustive, critical assessment is currently lacking in the relevant literature. The present review aims to fill this gap by giving a comprehensive picture of the ceramic-based materials and implants that are currently used in ophthalmology and pointing out the strengths and weaknesses of the existing devices. A prospect for future research is also provided, highlighting the potential of new, smart bioceramics able to carry specific added values which could have a significant impact on the treatment of ocular diseases.
Collapse
|
7
|
Baino F. How can bioactive glasses be useful in ocular surgery? J Biomed Mater Res A 2014; 103:1259-75. [DOI: 10.1002/jbm.a.35260] [Citation(s) in RCA: 32] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2014] [Revised: 05/29/2014] [Accepted: 05/31/2014] [Indexed: 11/10/2022]
Affiliation(s)
- Francesco Baino
- Institute of Materials Physics and Engineering, Applied Science and Technology Department; Politecnico di Torino, Corso Duca degli Abruzzi 24 10129 Torino Italy
| |
Collapse
|