1
|
Mitchinson AJ, Pogson M, Czanner G, Conway D, Wilkinson RR, Murphy MF, Siekmann I, Webb SD. A stochastic model for topographically influenced cell migration. J Theor Biol 2024; 581:111745. [PMID: 38272110 DOI: 10.1016/j.jtbi.2024.111745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 01/05/2024] [Accepted: 01/20/2024] [Indexed: 01/27/2024]
Abstract
Migrating cells traverse a range of topographic configurations presented by the native extracellular environment to conduct their physiologic functions. It is well documented cells can modulate their behaviour in response to different topographic features, finding promising applications in biomaterial and bioimplant design. It is useful, in these areas of research, to be able to predict which topographic arrangements could be used to promote certain patterns of migration prior to laboratory experimentation. Despite a profusion of study and interest shown in these fields by experimentalists, the related modelling literature is as yet relatively sparse and tend to focus more on either cell-matrix interaction or morphological responses of cells. We propose a mathematical model for individual cell migration based on an Ornstein-Uhlenbeck process, and set out to see if the model can be used to predict migration patterns on 2-d isotropic and anisotropic topographies, whose characteristics can be broadly described as either uniform flat, uniform linear with variable ridge density or non-uniform disordered with variable feature density. Results suggest the model is capable of producing realistic patterns of migration for flat and linear topographic patterns, with calibrated output closely approximating NIH3T3 fibroblast migration behaviour derived from an experimental dataset, in which migration linearity increased with ridge density and average speed was highest at intermediate ridge densities. Exploratory results for non-uniform disordered topographies suggest cell migration patterns may adopt disorderedness present in the topography and that 'distortion' introduced to linear topographic patterns may not impede linear guidance of migration, given its magnitude is bounded within certain limits. We conclude that an Ornstein-Uhlenbeck based model for topographically influenced migration may be useful to predict patterns of migration behaviour for certain isotropic (flat) and anisotropic (linear) topographies in the NIH3T3 fibroblast cell line, but additional investigation is required to predict with confidence migration patterns for non-uniform disordered topographic arrangements.
Collapse
Affiliation(s)
- A J Mitchinson
- School of Computer Science and Mathematics, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom.
| | - M Pogson
- Department of Communication and Media, University of Liverpool, Liverpool, L69 7ZG, United Kingdom
| | - G Czanner
- School of Computer Science and Mathematics, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom; PROTECT-eHealth, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom
| | - D Conway
- School of Biological Sciences, Queen's University Belfast, Belfast, BT9 5DL, United Kingdom
| | - R R Wilkinson
- School of Computer Science and Mathematics, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom
| | - M F Murphy
- School of Pharmacy and Biomolecular Sciences, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom
| | - I Siekmann
- School of Computer Science and Mathematics, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom; PROTECT-eHealth, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom; Liverpool Centre for Cardiovascular Science, Liverpool, United Kingdom; Data Science Research Centre, Liverpool John Moores University, Liverpool, L3 3AF, United Kingdom
| | - S D Webb
- Syngenta, Crop Protection Research, Jealott's Hill, Bracknell, RG42 6EY, United Kingdom
| |
Collapse
|
2
|
Su H, Yin S, Yang J, Wu Y, Shi C, Sun H, Wang G. In situ monitoring of circulating tumor cell adhered on three-dimensional graphene/ZnO macroporous structure by resistance change and electrochemical impedance spectroscopy. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.139093] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
3
|
Szczepańczyk P, Szlachta M, Złocista-Szewczyk N, Chłopek J, Pielichowska K. Recent Developments in Polyurethane-Based Materials for Bone Tissue Engineering. Polymers (Basel) 2021; 13:polym13060946. [PMID: 33808689 PMCID: PMC8003502 DOI: 10.3390/polym13060946] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 02/24/2021] [Accepted: 02/25/2021] [Indexed: 11/16/2022] Open
Abstract
To meet the needs of clinical medicine, bone tissue engineering is developing dynamically. Scaffolds for bone healing might be used as solid, preformed scaffolding materials, or through the injection of a solidifiable precursor into the defective tissue. There are miscellaneous biomaterials used to stimulate bone repair including ceramics, metals, naturally derived polymers, synthetic polymers, and other biocompatible substances. Combining ceramics and metals or polymers holds promise for future cures as the materials complement each other. Further research must explain the limitations of the size of the defects of each scaffold, and additionally, check the possibility of regeneration after implantation and resistance to disease. Before tissue engineering, a lot of bone defects were treated with autogenous bone grafts. Biodegradable polymers are widely applied as porous scaffolds in bone tissue engineering. The most valuable features of biodegradable polyurethanes are good biocompatibility, bioactivity, bioconductivity, and injectability. They may also be used as temporary extracellular matrix (ECM) in bone tissue healing and regeneration. Herein, the current state concerning polyurethanes in bone tissue engineering are discussed and introduced, as well as future trends.
Collapse
|
4
|
Somani M, Mukhopadhyay S, Gupta B. Surface features and patterning in hydrolytic functionalization of polyurethane films. Polym Bull (Berl) 2021. [DOI: 10.1007/s00289-021-03601-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
5
|
Hou Z, Xu J, Teng J, Jia Q, Wang X. Facile preparation of medical segmented poly(ester-urethane) containing uniformly sized hard segments and phosphorylcholine groups for improved hemocompatibility. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 109:110571. [PMID: 32228944 DOI: 10.1016/j.msec.2019.110571] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 11/29/2019] [Accepted: 12/17/2019] [Indexed: 12/12/2022]
Abstract
In order to improve the hemocompatibility of durable medical-grade polyurethane, a novel series of segmented poly(ester-urethane)s containing uniformly sized hard segments and phosphorylcholine (PC) groups on the side chains (SPU-PCs) was prepared by a facile method. The 2-methacryloyloxyethyl phosphorylcholine (MPC) was first reacted with α-thioglycerol by Michael addition to give a diol compound (MPC-diol), then the SPU-PCs with various PC content were prepared by a one-step chain extension of the mixture of MPC-diol and poly(ε-caprolactone) diol (PCL-diol) with aliphatic diurethane diisocyanates (HBH). The chemical structures of MPC-diol and SPU-PCs were confirmed by 1H NMR and FT-IR, and the influences of PC content on the physicochemical properties of the SPU-PC films were studied. The introduction of PC groups enhanced the degree of micro-phase separation and improved the hydrolytic degradation of the films. Due to the denser hydrogen bonds formed in the uniformly sized hard segments, the films exhibited favorable tensile properties and a slow hydrolytic degradation rate. The results of water contact angle and XPS analysis indicated that the PC groups on the flexible side chains were concentrated on the surface after contact with water. The surface hemocompatibility of the films was evaluated by testing the protein adsorption and platelet adhesion, and the results revealed that the films surfaces could dramatically suppress the protein adsorption and platelet adhesion. The PC-containing polyurethane films possessed outstanding tensile properties, low degradation rate and good surface hemocompatibility, implying their great potential for use as long-term implant or blood-contacting devices.
Collapse
Affiliation(s)
- Zhaosheng Hou
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, PR China.
| | - Jun Xu
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, PR China
| | - Jinwei Teng
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, PR China
| | - Qi Jia
- Jinan Thermal Power Co. Ltd., Jinan 250001, PR China
| | - Xuejie Wang
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, PR China
| |
Collapse
|
6
|
A mild method for surface-grafting MPC onto poly(ester-urethane) based on aliphatic diurethane diisocyanate with high grafting efficiency. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 104:109952. [DOI: 10.1016/j.msec.2019.109952] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 06/05/2019] [Accepted: 07/05/2019] [Indexed: 12/30/2022]
|
7
|
Liu L, Gao Y, Zhao J, Yuan L, Li C, Liu Z, Hou Z. A Mild Method for Surface-Grafting PEG Onto Segmented Poly(Ester-Urethane) Film with High Grafting Density for Biomedical Purpose. Polymers (Basel) 2018; 10:E1125. [PMID: 30961050 PMCID: PMC6403733 DOI: 10.3390/polym10101125] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Revised: 10/08/2018] [Accepted: 10/08/2018] [Indexed: 01/11/2023] Open
Abstract
In the paper, poly(ethylene glycol) (PEG) was grafted on the surface of poly(ester-urethane) (SPEU) film with high grafting density for biomedical purposes. The PEG-surface-grafted SPEU (SPEU-PEG) was prepared by a three-step chemical treatment under mild-reaction conditions. Firstly, the SPEU film surface was treated with 1,6-hexanediisocyanate to introduce -NCO groups on the surface with high density (5.28 × 10-7 mol/cm²) by allophanate reaction; subsequently, the -NCO groups attached to SPEU surface were coupled with one of -NH₂ groups of tris(2-aminoethyl)amine via condensation reaction to immobilize -NH₂ on the surface; finally, PEG with different molecular weight was grafted on the SPEU surface through Michael addition between terminal C = C bond of monoallyloxy PEG and -NH₂ group on the film surface. The chemical structure and modified surface were characterized by FT-IR, ¹H NMR, X-ray photoelectron spectroscopy (XPS), and water contact angle. The SPEU-PEGs displaying much lower water contact angles (23.9⁻21.8°) than SPEU (80.5°) indicated that the hydrophilic PEG chains improved the surface hydrophilicity significantly. The SPEU-PEG films possessed outstanding mechanical properties with strain at break of 866⁻884% and ultimate stress of 35.5⁻36.4 MPa, which were slightly lower than those of parent film, verifying that the chemical treatments had minimum deterioration on the mechanical properties of the substrate. The bovine serum albumin adsorption and platelet adhesion tests revealed that SPEU-PEGs had improved resistance to protein adsorption (3.02⁻2.78 μg/cm²) and possessed good resistance to platelet adhesion (781⁻697 per mm²), indicating good surface hemocompatibility. In addition, due to the high grafting density, the molecular weight of surface-grafted PEG had marginal effect on the surface hydrophilicity and hemocompatibility.
Collapse
Affiliation(s)
- Lulu Liu
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Yuanyuan Gao
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Juan Zhao
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Litong Yuan
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Chenglin Li
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Zhaojun Liu
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| | - Zhaosheng Hou
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, Shandong, China.
| |
Collapse
|
8
|
Fischer NG, Wong J, Baruth A, Cerutis DR. Effect of Clinically Relevant CAD/CAM Zirconia Polishing on Gingival Fibroblast Proliferation and Focal Adhesions. MATERIALS 2017; 10:ma10121358. [PMID: 29186907 PMCID: PMC5744293 DOI: 10.3390/ma10121358] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2017] [Revised: 11/06/2017] [Accepted: 11/22/2017] [Indexed: 01/08/2023]
Abstract
Mucosal seal formation around dental abutments is critical to the successful integration of dental implants into the human oral cavity. No information exists for how clinically relevant polishing procedures for computer-aided design and computer-aided manufactured (CAD/CAM) zirconia abutments affects cellular responses important to mucosal seal formation. CAD/CAM zirconia was divided into four groups for clinically relevant polishing utilizing commercial polishing heads: control, coarse, coarse plus medium, and coarse plus medium plus fine. Surfaces were analyzed with scanning electron microscopy (SEM), atomic force microscopy (AFM), and optical profilometry (OP). Subsequently, human gingival fibroblasts (HGFs) were seeded onto the zirconia surfaces. Proliferation was measured via a quantitative SEM technique and focal adhesion kinase (FAK) phosphorylation status was measured by an enzyme-linked immunosorbent assay (ELISA). Results showed an increase in proliferation on all polished surfaces as compared to the control. Phosphorylation of FAK at tyrosine 397 (Y397) was up-modulated on the control surfaces. The associated cell adaptation is discussed. In all cases, FAK phosphorylation was greater at 24 h than 48 h. These results suggest that clinicians should be mindful of the effects of abutment polishing methodology, as this may have an impact on early mucosal seal formation.
Collapse
Affiliation(s)
- Nicholas G Fischer
- Department of Physics, College of Arts and Sciences, Creighton University, 2500 California Plaza, Omaha, NE 68178, USA.
| | - Jeffrey Wong
- Department of Physics, College of Arts and Sciences, Creighton University, 2500 California Plaza, Omaha, NE 68178, USA.
| | - Andrew Baruth
- Department of Physics, College of Arts and Sciences, Creighton University, 2500 California Plaza, Omaha, NE 68178, USA.
| | - D Roselyn Cerutis
- Department of Oral Biology, School of Dentistry, Creighton University, 2802 Webster Street, Omaha, NE 68178, USA.
| |
Collapse
|
9
|
Valencia-Lazcano AA, Román-Doval R, De La Cruz-Burelo E, Millán-Casarrubias EJ, Rodríguez-Ortega A. Enhancing surface properties of breast implants by using electrospun silk fibroin. J Biomed Mater Res B Appl Biomater 2017; 106:1655-1661. [DOI: 10.1002/jbm.b.33973] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2017] [Revised: 07/18/2017] [Accepted: 08/04/2017] [Indexed: 11/09/2022]
Affiliation(s)
- A. A. Valencia-Lazcano
- Department of Science and Technology Development for Society; Centro de Investigación y de Estudios Avanzados del IPN; Ave. IPN 2508, San Pedro Zacatenco 07360, Mexico City Mexico
| | - R. Román-Doval
- Department of Nanoscience and Nanotechnology; Centro de Investigación y de Estudios Avanzados del IPN; Ave. IPN 2508, San Pedro Zacatenco, Mexico City Mexico
| | - E. De La Cruz-Burelo
- Department of Science and Technology Development for Society; Centro de Investigación y de Estudios Avanzados del IPN; Ave. IPN 2508, San Pedro Zacatenco 07360, Mexico City Mexico
- Physics Department; Centro de Investigación y de Estudios Avanzados del IPN; Ave. IPN 2508, San Pedro Zacatenco 07360, Mexico City Mexico
| | - E. J. Millán-Casarrubias
- Department of Nanoscience and Nanotechnology; Centro de Investigación y de Estudios Avanzados del IPN; Ave. IPN 2508, San Pedro Zacatenco, Mexico City Mexico
| | - A. Rodríguez-Ortega
- Agrotechnology Engineering Department; Universidad Politécnica Francisco I. Madero; Tepatepec Hidalgo Mexico
| |
Collapse
|
10
|
Hu X, Sun A, Kang W, Zhou Q. Strategies and knowledge gaps for improving nanomaterial biocompatibility. ENVIRONMENT INTERNATIONAL 2017; 102:177-189. [PMID: 28318601 DOI: 10.1016/j.envint.2017.03.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2016] [Revised: 02/26/2017] [Accepted: 03/01/2017] [Indexed: 06/06/2023]
Abstract
With rapid development of nanotechnology and nanomaterials, nanosafety has attracted wide attention in all fields related to nanotechnology. As well known, a grand challenge in nanomaterial applications is their biocompatibility. It is urgent to explore effective strategies to control the unintentional effects. Although many novel methods for the synthesis of biocompatible and biodegradable nanomaterials are reported, the control strategy of nanotoxicity remains in its infancy. It is urgent to review the archived strategies for improving nanomaterial biocompatibility to clarify what we have done and where we should be. In this review, the achievements and challenges in nanomaterial structure/surface modifications and size/shape controls were analyzed. Moreover, the chemical and biological strategies to make nanomaterial more biocompatible and biodegradable were compared. Finally, the concerns that have not been studied well were prospected, involving unintended releases, life-cycle, occupational exposure and methodology.
Collapse
Affiliation(s)
- Xiangang Hu
- Key Laboratory of Pollution Processes and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China.
| | - Anqi Sun
- Key Laboratory of Pollution Processes and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China
| | - Weilu Kang
- Key Laboratory of Pollution Processes and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China
| | - Qixing Zhou
- Key Laboratory of Pollution Processes and Environmental Criteria, Ministry of Education, College of Environmental Science and Engineering, Nankai University, Tianjin 300071, China
| |
Collapse
|