1
|
El-Kamel RS, Fekry AM. Enhanced modified poly-tyrosine voltammetric sensor for the quantification detection of salivary pepsin. Int J Biol Macromol 2024; 277:134178. [PMID: 39067726 DOI: 10.1016/j.ijbiomac.2024.134178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2024] [Revised: 07/23/2024] [Accepted: 07/24/2024] [Indexed: 07/30/2024]
Abstract
Pepsin as an aspartic acid protease member and one of the three foremost proteolytic enzymes in the digestive system is essential to be detected. An electrochemically polymerized tyrosine film on carbon paste electrode (pTyr/CPE) has been synthesized by electro-polymerization donating an affordable electrochemical sensor to sense salivary pepsin as a diagnostic technique for gastroesophageal reflux disease (GRD) due to saliva collection is non-invasive and relatively comfortable. The pTyr/CPE was applied for Voltammetric sensing of pepsin and its quantification in phosphate buffer solution of pH 2.0 (PBS). Scanning electron microscopy (SEM) was conducted to learn the surface morphology. Cyclic voltammetry (CV), differential pulse voltammetry (DPVs), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) were developed to realize the electrocatalytic activity of the sensor. The pTyr/CPE proceeded as a sensitive detector to pepsin with two linear ranges from 1 to 20 & 20 to 100 ng/mL donating two limits of detection as 0.5 & 0.09 ng/mL, respectively, and high selectivity toward pepsin, as well as stability and fast response of 1.5 s. Consequently, it is guessed that the pTyr/CPE sensor could be supportive for the initial diagnosis of GRD through the detection of pepsin in saliva. Finally, we quantified the pepsin levels in saliva samples of LPR patients (n = 2), showing that the results were agreeable with those from the electrochemical sensor.
Collapse
Affiliation(s)
- Renad S El-Kamel
- Cairo University, Faculty of Science, Department of Chemistry, Giza, Egypt
| | - Amany M Fekry
- Cairo University, Faculty of Science, Department of Chemistry, Giza, Egypt.
| |
Collapse
|
2
|
Fekry AM, Filippova IV, Medany SS, Abdel-Gawad SA, Filippov LO. Use of a natural rock material as a precursor to inhibit corrosion of Ti alloy in an aggressive phosphoric acid medium. Sci Rep 2024; 14:9807. [PMID: 38684748 PMCID: PMC11058858 DOI: 10.1038/s41598-024-60403-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 04/23/2024] [Indexed: 05/02/2024] Open
Abstract
The mechanism of interaction between magnesite mineral and phosphoric acid (0.001-0.5 M) in addition to the determination of the protective properties for Ti alloy (working electrode) in phosphoric acid both with and without an inhibitor have been investigated by electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization measurements. Results of electrochemical tests show that the corrosion resistance of titanium alloy in phosphoric acid solution only increased and hydrogen production decreased by either decreasing acid concentration or increasing immersion time associated with the thickening of the oxide film formed on the alloy surface. On adding magnesite, the corrosion resistance of Ti alloy is enhanced by increasing the phosphoric acid concentration (0.001-0.5 M) due to the formation of sparingly soluble magnesium phosphate film on the alloy surface that inhibits the effect of increasing hydrogen evolution reaction due to the pH value decreases. The increasing adsorption behavior of the magnesite inhibitor and decreasing its diffusion were deduced from EIS measurements. Thus, the addition of 3% magnesite minimizes the corrosion by forming a new protective film (Mg3(PO4)2), which differs from the traditional passive film and prevents the effect of the increase of hydrogen evolution. The surface morphology and chemical composition of the tested alloy were determined using scanning electron microscopy (SEM), Fourier transform Infra-Red spectroscopy (FTIR), X-ray diffraction (XRD), X-ray Fluorescence (XRF) and In situ Raman spectroscopy.
Collapse
Affiliation(s)
- Amany M Fekry
- Université de Lorraine, CNRS, GeoRessources, 54000, Nancy, France.
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
| | - Inna V Filippova
- Université de Lorraine, CNRS, GeoRessources, 54000, Nancy, France
| | - Shymaa S Medany
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
| | - Soha A Abdel-Gawad
- Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt
- Faculty of Postgraduate Studies for Nanotechnology, Cairo University, Giza, Egypt
| | - Lev O Filippov
- Université de Lorraine, CNRS, GeoRessources, 54000, Nancy, France.
| |
Collapse
|
3
|
Asaduzzaman Chowdhury M, Helal Hossain MD, Hossain N, Hossen Z, Arefin Kowser M, Masud Rana M. Advances in coatings on Mg alloys and their anti-microbial activity for implant applications. ARAB J CHEM 2022. [DOI: 10.1016/j.arabjc.2022.104214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|
4
|
Dai D, Zhou D, Xie H, Wang J, Zhang C. The design, construction and application of graphene family composite nanocoating on dental metal surface. BIOMATERIALS ADVANCES 2022; 140:213087. [PMID: 36029723 DOI: 10.1016/j.bioadv.2022.213087] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Revised: 08/14/2022] [Accepted: 08/18/2022] [Indexed: 06/15/2023]
Abstract
Enhancement of the biological and mechanical properties of dental metals is important for accommodation with therapeutic schemes in different stomatological disciplines. Nanocoatings based on graphene family nanomaterials (GFNs) improve the topological structure and physicochemical properties of metal surfaces, endowing them with new properties while maintaining inherent mechanical properties. Nano-composite coatings, composed of GFNs with one or more type of polymer, metal, oxide, and inorganic nonmetallic compound, offer more matching modification schemes to meet multifunctional oral treatment requirements (e.g., anti-bacterial and anti-corrosive activity, osteogenesis and angiogenesis). This review describes recent progress in the development of GFN composite nanocoatings for the modification of dental metals, focus on biological effects in clinical settings. Underlying molecular mechanisms, critical modification schemes, and technical innovation in preparation methods are also discussed. The key parameters of GFN composite nanocoating surface modification are summarized according to effects on cellular responses and antibacterial activity. This review provides a theoretical reference for the optimization of the biological effects and application of GFN composite nanocoatings for dental metals, and the promotion of the environmentally friendly large-scale production of high-quality multifunctional GFN-based nanocoatings in the field of oral science.
Collapse
Affiliation(s)
- Danni Dai
- Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
| | - Dongshuai Zhou
- School of Materials Engineering, Jiangsu University of Technology, Changzhou 213001, China
| | - Hanshu Xie
- Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
| | - Jianrong Wang
- Stomatological Hospital, Southern Medical University, Guangzhou 510280, China
| | - Chao Zhang
- Stomatological Hospital, Southern Medical University, Guangzhou 510280, China.
| |
Collapse
|
5
|
A Degradable and Osteogenic Mg-Based MAO-MT-PLGA Drug/Ion Delivery System for Treating an Osteoporotic Fracture. Pharmaceutics 2022; 14:pharmaceutics14071481. [PMID: 35890376 PMCID: PMC9320112 DOI: 10.3390/pharmaceutics14071481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 07/02/2022] [Accepted: 07/11/2022] [Indexed: 12/10/2022] Open
Abstract
Osteoporotic fractures are a very common bone disease that is difficult to completely cure. A large number of people worldwide suffer from pain caused by osteoporotic fractures every year, which can even cause disability and death. The compromised skeletal strength, lower density, trabecular microstructure, and bone-forming ability caused by osteoporotic fractures make them difficult to treat relative to normal fractures. An ideal scheme for osteoporotic fractures is to select internal fixation materials with matched mechanical and biological properties and carry anti-osteoporosis drugs on the plant to achieve bio-fixation and improve the condition of osteoporosis simultaneously. We designed a Mg-based MAO-MT-PLGA drug/ion delivery system (DDS) compatible with bone-like mechanical properties, degradation properties, and drug therapy. In this research, we evaluated the degradation behavior of Mg-based MAO-MT-PLGA DDS using immersion tests and electrochemical tests aided by SEM, EDS, XPS, XRD, and FT-IR. The DDS showed better corrosion resistance over Mg alloy and could release more Mg2+ due to the degradation of PLGA. According to cell viability and cell adhesion, the DDS showed better osteogenic characteristics over control group I (Mg alloy) and control group II (Mg-based MAO alloy), especially in the cells co-cultured with the leaching solution for 72 h, in which the DDS group increased to about 15% cell viability compared with group I (p < 0.05). The mRNA relative expressions, including ALP, collagen I, OCN, OPG, and Runx-2, as well as extracellular matrix calcium deposits of the DDS, are 1.5~2 times over control group I and control group II (p < 0.05), demonstrating a better ability to promote bone formation and inhibit bone resorption. After the DDS was implanted into the castrated rat model for one month, the trabeculae in the treatment group were significantly denser and stronger than those in the control group, with a difference of about 1.5 times in bone volume fraction, bone density, and the number of trabeculae, as well as the magnesium content in the bone tissue (p < 0.05). The above results demonstrated that the Mg-based MAO-MT-PLGA drug/ion delivery system is a potential treatment for osteoporotic fractures.
Collapse
|
6
|
Development of a nanocapsule-loaded hydrogel for drug delivery for intraperitoneal administration. Int J Pharm 2022; 622:121828. [PMID: 35595041 DOI: 10.1016/j.ijpharm.2022.121828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 05/01/2022] [Accepted: 05/09/2022] [Indexed: 11/22/2022]
Abstract
Intraperitoneal (IP) drug delivery of chemotherapeutic agents, administered through hyperthermal intraperitoneal chemotherapy (HIPEC) and pressurized intraperitoneal aerosolized chemotherapy (PIPAC), is effective for the treatment of peritoneal malignancies. However, these therapeutic interventions are cumbersome in terms of surgical practice and are often associated with the formation of peritoneal adhesions, due to the catheters inserted into the peritoneal cavity during these procedures. Hence, there is a need for the development of drug delivery systems that can be administered into the peritoneal cavity. In this study, we have developed a nanocapsule (NCs)-loaded hydrogel for drug delivery in the peritoneal cavity. The hydrogel has been developed using poly(ethylene glycol) (PEG) and thiol-maleimide chemistry. NCs-loaded hydrogels were characterized by rheology and their resistance to dilution and drug release were determined in vitro. Using IVIS® to measure individual organ and recovered gel fluorescence intensity, an in vivo imaging study was performed and demonstrated that NCs incorporated in the PEG gel were retained in the IP cavity for 24 h after IP administration. NCs-loaded PEG gels could find potential applications as biodegradable, drug delivery systems that could be implanted in the IP cavity, for example at a the tumour resection site to prevent recurrence of microscopic tumours.
Collapse
|
7
|
Guo X, Hu Y, Yuan K, Qiao Y. Review of the Effect of Surface Coating Modification on Magnesium Alloy Biocompatibility. MATERIALS 2022; 15:ma15093291. [PMID: 35591624 PMCID: PMC9100161 DOI: 10.3390/ma15093291] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Revised: 04/24/2022] [Accepted: 05/02/2022] [Indexed: 12/26/2022]
Abstract
Magnesium alloy, as an absorbable and implantable biomaterial, has been greatly developed in the application field of biomaterials in recent years due to its excellent biocompatibility and biomechanics. However, due to the poor corrosion resistance of magnesium alloy in the physiological environment, the degradation rate will be unbalanced, which seriously affects the clinical use. There are two main ways to improve the corrosion resistance of magnesium alloy: one is by adding alloying elements, the other is by surface modification technology. Compared with adding alloy elements, the surface coating modification has the following advantages: (1) The surface coating modification is carried out without changing the matrix elements of magnesium alloy, avoiding the introduction of other elements; (2) The corrosion resistance of magnesium alloy can be improved by relatively simple physical, chemical, or electrochemical improvement. From the perspective of corrosion resistance and biocompatibility of biomedical magnesium alloy materials, this paper summarizes the application and characteristics of six different surface coating modifications in the biomedical magnesium alloy field, including chemical conversion method, micro-arc oxidation method, sol-gel method, electrophoretic deposition, hydrothermal method, and thermal spraying method. In the last section, it looks forward to the development prospect of surface coating modification and points out that preparing modified coatings on the implant surface combined with various modification post-treatment technologies is the main direction to improve biocompatibility and realize clinical functionalization.
Collapse
Affiliation(s)
| | | | | | - Yang Qiao
- Correspondence: ; Tel.: +86-152-7510-6865
| |
Collapse
|
8
|
GO-based antibacterial composites: Application and design strategies. Adv Drug Deliv Rev 2021; 178:113967. [PMID: 34509575 DOI: 10.1016/j.addr.2021.113967] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 08/18/2021] [Accepted: 09/05/2021] [Indexed: 12/15/2022]
Abstract
Graphene oxide (GO), for its unique structure with high biocompatibility and designability, is widely used in the antibacterial field. Various strategies have been designed to fabricate GO-based composites with antibacterial properties. This review summarized these strategies, divided them into three types and interpreted their antibacterial mechanisms: (i) "GO*/non-GO" type in which GO acts as the single antibacterial core, (ii) "GO*/non-GO*" type in which GO and non-GO components function synergistically as dual antibacterial cores, (iii) "GO/non-GO*" type in which non-GO acts as the single antibacterial core, while GO component plays a supportive, not a dominant role in antibiosis. Besides, the fields suiting their applications and factors influencing their antibacterial properties were analyzed. Finally, the limitations and prospects in the current researches were discussed. In summary, GO-based composites have revolutionized antibacterial strategies. This review may serve as a reference to inspire further research on GO-based antibacterial composites.
Collapse
|
9
|
Park S, Lee H, Kim HE, Jung HD, Jang TS. Bifunctional poly (l-lactic acid)/hydrophobic silica nanocomposite layer coated on magnesium stents for enhancing corrosion resistance and endothelial cell responses. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 127:112239. [PMID: 34225879 DOI: 10.1016/j.msec.2021.112239] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 05/25/2021] [Accepted: 06/02/2021] [Indexed: 11/28/2022]
Abstract
Biodegradable magnesium (Mg)-based vascular stents can overcome the limitations of conventional permanent metallic stents, such as late in-stent restenosis and thrombosis, but still have difficulty retarding degradation while providing adequate mechanical support to the blood vessel. We incorporated silica nanoparticles surface-functionalized with hexadecyltrimethoxysilane (mSiNP) into a poly (l-lactic acid) (PLLA) coating as a physical barrier to disturb the penetration of the corrosive medium as well as a bioactive source that releases silicon ions capable of stimulating endothelial cells. The corrosion resistance and biocompatibility of this bifunctional PLLA/mSiNP nanocomposite coating were investigated using different weight ratios of mSiNP. The nanocomposite coating containing more than 10 wt% of the mSiNP (PLLA/10mSiNP and PLLA/20mSiNP) significantly delayed the corrosion of the Mg substrate and exhibited favorable endothelial cell responses, compared to the pure PLLA coating. Specifically, the calculated corrosion rates of PLLA/10mSiNP and PLLA/20mSiNP decreased by half, indicating the durability of the coating after immersion in simulated body fluid for 12 days. Based on the in vitro cellular response, the incorporation of the mSiNPs into the PLLA coating significantly improved the endothelial cell responses to the Mg substrate, showing better initial cell surface coverage, migration, and proliferation rate than those of pure PLLA. These results indicate that the PLLA/mSiNP nanocomposite coatings have significant potential to improve the corrosion resistance and vascular compatibility of biodegradable Mg-based vascular stents.
Collapse
Affiliation(s)
- Suhyung Park
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea
| | - Hyun Lee
- Department of Biomedical-Chemical Engineering, Catholic University of Korea, Bucheon, Republic of Korea; Department of Biotechnology, The Catholic University of Korea, Bucheon 14662, Republic of Korea
| | - Hyoun-Ee Kim
- Department of Materials Science and Engineering, Seoul National University, Seoul, Republic of Korea; Biomedical Implant Convergence Research lab, Advanced Institutes of Convergence Technology, Suwon, Republic of Korea
| | - Hyun-Do Jung
- Department of Biomedical-Chemical Engineering, Catholic University of Korea, Bucheon, Republic of Korea; Department of Biotechnology, The Catholic University of Korea, Bucheon 14662, Republic of Korea.
| | - Tae-Sik Jang
- Department of Materials Science and Engineering, Chosun University, Gwangju, Republic of Korea.
| |
Collapse
|
10
|
Advances in Antibacterial Functionalized Coatings on Mg and Its Alloys for Medical Use—A Review. COATINGS 2020. [DOI: 10.3390/coatings10090828] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
As a revolutionary implant material, magnesium and its alloys have many exciting performances, such as biodegradability, mechanical compatibility, and excellent biosecurity. However, the rapid and uncontrollable degradation rate of magnesium greatly hampers its clinical use. Many efforts have been taken to enhance the corrosion resistance of magnesium. However, it must be noted that improving the corrosion resistance of magnesium will lead to the compromise of its antibacterial abilities, which are attribute and proportional to the alkaline pH during its degradation. Providing antibacterial functionalized coating is one of the best methods for balancing the degradation rate and the antibacterial ability of magnesium. Antibacterial functionalized magnesium is especially well-suited for patients with diabetes and infected wounds. Considering the extremely complex biological environment in the human body and the demands of enhancing corrosion resistance, biocompatibility, osteogenesis, and antibacterial ability, composite coatings with combined properties of different materials may be promising. The aim of this review isto collect and compare recent studies on antibacterial functionalized coatings on magnesium and its alloys. The clinical applications of antibacterial functionalized coatings and their material characteristics, antibacterial abilities, in vitro cytocompatibility, and corrosion resistance are also discussed in detail.
Collapse
|