1
|
Huang HH, Chen ZH, Nguyen DT, Tseng CM, Chen CS, Chang JH. Blood Coagulation on Titanium Dioxide Films with Various Crystal Structures on Titanium Implant Surfaces. Cells 2022; 11:cells11172623. [PMID: 36078030 PMCID: PMC9454428 DOI: 10.3390/cells11172623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 08/18/2022] [Accepted: 08/19/2022] [Indexed: 11/18/2022] Open
Abstract
Background: Titanium (Ti) is one of the most popular implant materials, and its surface titanium dioxide (TiO2) provides good biocompatibility. The coagulation of blood on Ti implants plays a key role in wound healing and cell growth at the implant site; however, researchers have yet to fully elucidate the mechanism underlying this process on TiO2. Methods: This study examined the means by which blood coagulation was affected by the crystal structure of TiO2 thin films (thickness < 50 nm), including anatase, rutile, and mixed anatase/rutile. The films were characterized in terms of roughness using an atomic force microscope, thickness using an X-ray photoelectron spectrometer, and crystal structure using transmission electron microscopy. The surface energy and dielectric constant of the surface films were measured using a contact angle goniometer and the parallel plate method, respectively. Blood coagulation properties (including clotting time, factor XII contact activation, fibrinogen adsorption, fibrin attachment, and platelet adhesion) were then assessed on the various test specimens. Results: All of the TiO2 films were similar in terms of surface roughness, thickness, and surface energy (hydrophilicity); however, the presence of rutile structures was associated with a higher dielectric constant, which induced the activation of factor XII, the formation of fibrin network, and platelet adhesion. Conclusions: This study provides detailed information related to the effects of TiO2 crystal structures on blood coagulation properties on Ti implant surfaces.
Collapse
Affiliation(s)
- Her-Hsiung Huang
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Institute of Oral Biology, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung 413, Taiwan
- Department of Medical Research, China Medical University Hospital, China Medical University, Taichung 404, Taiwan
- Department of Stomatology, Taipei Veterans General Hospital, Taipei 112, Taiwan
- Department of Education and Research, Taipei City Hospital, Taipei 103, Taiwan
- Correspondence: (H.-H.H.); (C.-S.C.)
| | - Zhi-Hwa Chen
- Institute of Oral Biology, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| | - Diem Thuy Nguyen
- Department of Dentistry, National Yang Ming Chiao Tung University, Taipei 112, Taiwan
| | - Chuan-Ming Tseng
- Department of Materials Engineering and Center for Plasma and Thin Film Technologies, Ming Chi University of Technology, New Taipei City 243, Taiwan
| | - Chiang-Sang Chen
- Department of Orthopedics, Far Eastern Memorial Hospital, New Taipei City 220, Taiwan
- Department of Materials and Textiles, Asia Eastern University of Science and Technology, New Taipei City 220, Taiwan
- Correspondence: (H.-H.H.); (C.-S.C.)
| | - Jean-Heng Chang
- Dental Department, Cheng Hsin General Hospital, Taipei 112, Taiwan
| |
Collapse
|
2
|
Wu X, Wang C, Hao P, He F, Yao Z, Zhang X. Adsorption properties of albumin and fibrinogen on hydrophilic/hydrophobic TiO 2 surfaces: A molecular dynamics study. Colloids Surf B Biointerfaces 2021; 207:111994. [PMID: 34303996 DOI: 10.1016/j.colsurfb.2021.111994] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 07/06/2021] [Accepted: 07/16/2021] [Indexed: 01/23/2023]
Abstract
In serval experimental researches, UV-induced hydrophilicity enabled better hemocompatibility in the TiO2 surface, which was considered to be caused by the removal of the carboxylic acid contamination from the surface. In this paper, we altered the surface wetting property by applying the formate contamination on the rutile (110) surface, and systematically investigated the adsorption properties of albumin and fibrinogen on hydrophilic/hydrophobic TiO2 surface. Unique contacts were found between the charged residues and the hydrophilic surface, anchoring the protein on the surface. The small size and the heart shape of albumin make it easy to cross the stable water layers near the surface. Besides, albumin has a higher proportion of charged residues, so it can form more unique contacts on the hydrophilic surface. Therefore, the albumin tends to adsorb on the hydrophilic surface. For the hydrophobic surface, the water layers near the surface are weakened, which helps the fibrinogen diffusing to the surface and adjusting its orientation. Although the hydrophobic surface cannot form the unique contacts, the larger size of fibrinogen can provide more residues to form enough ordinary contacts after adjusting, and then achieves stable adsorption. Therefore, fibrinogen tends to adsorb on the hydrophobic surface.
Collapse
Affiliation(s)
- Xiao Wu
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Chenyang Wang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Pengfei Hao
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Feng He
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China
| | - Zhaohui Yao
- University of Chinese Academy of Sciences, Beijing, 101408, China
| | - Xiwen Zhang
- Department of Engineering Mechanics, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
3
|
Effects of diameters and crystals of titanium dioxide nanotube arrays on blood compatibility and endothelial cell behaviors. Colloids Surf B Biointerfaces 2019; 184:110521. [PMID: 31569001 DOI: 10.1016/j.colsurfb.2019.110521] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 08/20/2019] [Accepted: 09/21/2019] [Indexed: 12/15/2022]
Abstract
Titanium dioxide nanotube arrays (TNTAs) have attracted extensive attention in the fields of biomaterials and biomedicine due to their unique tubular structure and good biocompatibility. In this paper, TNTAs with different nanotube diameters and lengths were in situ prepared on the titanium surface by the anodic oxidation, and their crystal structures were further changed by annealing treatment. The effects of TNTAs with different diameters and crystals on the blood compatibility and endothelial cell behaviors were investigated. The results showed that TNTAs with the diameter of 30∼90 nm can be obtained by controlling the anodization voltage, and annealing treatment did not obviously change the diameters and lengths of the nanotube arrays. However, annealing treatment can transform the amorphous TNTAs into the anatase structure. The diameter and crystal structure of the nanotube arrays played a key role in the surface wettability and protein adsorption. The nanotube array with larger diameter displayed better surface hydrophilicity as compared to the pristine titanium, and annealing treatment further enhanced the hydrophilicity. As compared to the pristine titanium, the nanotube array structure had the characteristic of selective protein adsorption, and the nanotube array can promote the bovine serum albumin (BSA) adsorption and prevent the fibrinogen (FIB) adsorption, however, the increase of nanotube diameter could reduce BSA adsorption and increase FIB adsorption. Besides, the nanotube array with anatase structure can promote BSA adsorption while reduce FIB adsorption. Therefore, the TNTAs with smaller diameter and anatase crystal had good blood compatibility and cell compatibility, they can not only reduce platelet adhesion and hemolysis rate but also increase endothelial cell adhesion and proliferation. In conclusion, the nanotube arrays of the present study can be used to improve the cell compatibility and blood compatibility of the titanium implants.
Collapse
|
4
|
Influence of the Electrolyte Concentration on the Smooth TiO2 Anodic Coatings on Ti-6Al-4V. COATINGS 2017. [DOI: 10.3390/coatings7030039] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|