1
|
Yang C, Wang Z, Xiao K, Ushakov N, Kumar S, Li X, Min R. Portable optical fiber biosensors integrated with smartphone: technologies, applications, and challenges [Invited]. BIOMEDICAL OPTICS EXPRESS 2024; 15:1630-1650. [PMID: 38495719 PMCID: PMC10942678 DOI: 10.1364/boe.517534] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/04/2024] [Accepted: 02/04/2024] [Indexed: 03/19/2024]
Abstract
The increasing demand for individualized health monitoring and diagnostics has prompted considerable research into the integration of portable optical fiber biosensors integrated with smartphones. By capitalizing on the benefits offered by optical fibers, these biosensors enable qualitative and quantitative biosensing across a wide range of applications. The integration of these sensors with smartphones, which possess advanced computational power and versatile sensing capabilities, addresses the increasing need for portable and rapid sensing solutions. This extensive evaluation thoroughly examines the domain of optical fiber biosensors in conjunction with smartphones, including hardware complexities, sensing approaches, and integration methods. Additionally, it explores a wide range of applications, including physiological and chemical biosensing. Furthermore, the review provides an analysis of the challenges that have been identified in this rapidly evolving area of research and concludes with relevant suggestions for the progression of the field.
Collapse
Affiliation(s)
- Chengwei Yang
- Center for Cognition and Neuroergonomics, State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Zhuhai 519087, China
| | - Zhuo Wang
- Center for Cognition and Neuroergonomics, State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Zhuhai 519087, China
| | - Kun Xiao
- Faculty of Arts and Sciences, Beijing Normal University, Zhuhai 519087, China
| | - Nikolai Ushakov
- Institute of Electronics and Telecommunications, Peter the Great St. Petersburg Polytechnic University, 195251 St. Petersburg, Russia
| | - Santosh Kumar
- Department of Electronics and Communication Engineering, K L Deemed to be University, Guntur, Andhra Pradesh 522302, India
| | - Xiaoli Li
- School of Automation Science and Engineering, South China University of Technology, Guangzhou 510641, China
- Guangdong Artificial Intelligence and Digital Economy Laboratory (Guangzhou), Guangzhou 510335, China
| | - Rui Min
- Center for Cognition and Neuroergonomics, State Key Laboratory of Cognitive Neuroscience and Learning, Beijing Normal University, Zhuhai 519087, China
| |
Collapse
|
2
|
Gradisteanu Pircalabioru G, Raileanu M, Dionisie MV, Lixandru-Petre IO, Iliescu C. Fast detection of bacterial gut pathogens on miniaturized devices: an overview. Expert Rev Mol Diagn 2024; 24:201-218. [PMID: 38347807 DOI: 10.1080/14737159.2024.2316756] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Accepted: 02/06/2024] [Indexed: 03/23/2024]
Abstract
INTRODUCTION Gut microbes pose challenges like colon inflammation, deadly diarrhea, antimicrobial resistance dissemination, and chronic disease onset. Development of early, rapid and specific diagnosis tools is essential for improving infection control. Point-of-care testing (POCT) systems offer rapid, sensitive, low-cost and sample-to-answer methods for microbe detection from various clinical and environmental samples, bringing the advantages of portability, automation, and simple operation. AREAS COVERED Rapid detection of gut microbes can be done using a wide array of techniques including biosensors, immunological assays, electrochemical impedance spectroscopy, mass spectrometry and molecular biology. Inclusion of Internet of Things, machine learning, and smartphone-based point-of-care applications is an important aspect of POCT. In this review, the authors discuss various fast diagnostic platforms for gut pathogens and their main challenges. EXPERT OPINION Developing effective assays for microbe detection can be complex. Assay design must consider factors like target selection, real-time and multiplex detection, sample type, reagent stability and storage, primer/probe design, and optimizing reaction conditions for accuracy and sensitivity. Mitigating these challenges requires interdisciplinary collaboration among scientists, clinicians, engineers, and industry partners. Future efforts are essential to enhance sensitivity, specificity, and versatility of POCT systems for gut microbe detection and quantification, advancing infectious disease diagnostics and management.
Collapse
Affiliation(s)
- Gratiela Gradisteanu Pircalabioru
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
- Division of Earth, Environmental and Life Sciences, The Research Institute of University of Bucharest (ICUB), Bucharest, Romania
- Academy of Romanian Scientists, Bucharest, Romania
| | - Mina Raileanu
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
- Department of Life and Environmental Physics, Horia Hulubei National Institute of Physics and Nuclear Engineering, Magurele, Romania
| | - Mihai Viorel Dionisie
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
| | - Irina-Oana Lixandru-Petre
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
| | - Ciprian Iliescu
- eBio-hub Research Centre, National University of Science and Technology "Politehnica" Bucharest, Bucharest, Romania
- Academy of Romanian Scientists, Bucharest, Romania
- Microsystems in Biomedical and Environmental Applications, National Research and Development Institute for Microtechnology, Bucharest, Romania
| |
Collapse
|
3
|
Wu C, Tan P, Chen X, Chang H, Chen Y, Su G, Liu T, Lu Z, Sun M, Wang Y, Zou Y, Wang J, Rao H. Machine Learning-Assisted High-Throughput Strategy for Real-Time Detection of Spermine Using a Triple-Emission Ratiometric Probe. ACS APPLIED MATERIALS & INTERFACES 2023; 15:48506-48518. [PMID: 37796018 DOI: 10.1021/acsami.3c09836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
In this study, we designed and fabricated a spermine-responsive triple-emission ratiometric fluorescent probe using dual-emissive carbon nanoparticles and quantum dots, which improve the sensor's accuracy and reduce interfering environmental effects. The probe is advantageous for the proportionate detection of spermine because it has good emission resolution, and the maximum points of the two emission peaks differ by 95 nm. As a proof of concept, cuvettes and a 96-well plate were combined with a smartphone and YOLO series algorithms to accomplish real-time, visual, and high-throughput detection of seafood and meat freshness. In addition, the reaction mechanism was verified by density functional theory and fundamental characterizations. Upon exposure to different amounts of spermine, the intensity of the fluorescent probe changed linearly, and the fluorescent color shifted from yellow-green to red, with a limit of detection of 0.33 μM. To enable visual identification of food-originated spermine, a hydrogel-based visual sensing platform was successfully developed utilizing the triple-emission fluorescent probe. Consequently, spermine could be identified and quantified without complicated equipment.
Collapse
Affiliation(s)
- Chun Wu
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Ping Tan
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Xianjin Chen
- College of Information Engineering, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Hongrong Chang
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Yuhui Chen
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Gehong Su
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Tao Liu
- College of Information Engineering, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Zhiwei Lu
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Mengmeng Sun
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Yanying Wang
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Yuanfeng Zou
- College of Veterinary Medicine, Sichuan Agricultural University, Huimin Road, Wenjiang District, Chengdu 611130, P. R. China
| | - Jian Wang
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| | - Hanbing Rao
- College of Science, Sichuan Agricultural University, Xinkang Road, Yucheng District, Ya'an 625014, P. R. China
| |
Collapse
|
4
|
Li S, Qin Z, Fu J, Gao Q. Nanobiosensing Based on Electro-Optically Modulated Technology. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:2400. [PMID: 37686908 PMCID: PMC10489767 DOI: 10.3390/nano13172400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 08/22/2023] [Accepted: 08/22/2023] [Indexed: 09/10/2023]
Abstract
At the nanoscale, metals exhibit special electrochemical and optical properties, which play an important role in nanobiosensing. In particular, surface plasmon resonance (SPR) based on precious metal nanoparticles, as a kind of tag-free biosensor technology, has brought high sensitivity, high reliability, and convenient operation to sensor detection. By applying an electrochemical excitation signal to the nanoplasma device, modulating its surface electron density, and realizing electrochemical coupling SPR, it can effectively complete the joint transmission of electrical and optical signals, increase the resonance shift of the spectrum, and further improve the sensitivity of the designed biosensor. In addition, smartphones are playing an increasingly important role in portable mobile sensor detection systems. These systems typically connect sensing devices to smartphones to perceive different types of information, from optical signals to electrochemical signals, providing ideas for the portability and low-cost design of these sensing systems. Among them, electrochemiluminescence (ECL), as a special electrochemically coupled optical technology, has good application prospects in mobile sensing detection due to its strong anti-interference ability, which is not affected by background light. In this review, the SPR is introduced using nanoparticles, and its response process is analyzed theoretically. Then, the mechanism and sensing application of electrochemistry coupled with SPR and ECL are emphatically introduced. Finally, it extends to the relevant research on electrochemically coupled optical sensing on mobile detection platforms.
Collapse
Affiliation(s)
- Shuang Li
- Academy of Medical Engineering and Translational Medicine, Medical College, Tianjin University, Tianjin 300072, China; (Z.Q.); (J.F.); (Q.G.)
| | | | | | | |
Collapse
|
5
|
Yang S, Dai W, Tang M, Wang J. Nonstoichiometric Nanocubes with a Controllable Morphology and Persistent Luminescence for Autofluorescence-Free Biosensing. ACS APPLIED MATERIALS & INTERFACES 2023; 15:38644-38652. [PMID: 37527437 DOI: 10.1021/acsami.3c05895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/03/2023]
Abstract
Persistent luminescence nanoparticles (PLNPs) have shown special advantages in areas such as bioimaging, cancer therapy, stress sensing, and photo-biocatalysis. However, the lack of methods for controllable synthesis of PLNPs with uniform morphologies and strong persistent luminescence has seriously hindered the applications of PLNPs. Herein, we reported that modifying the electronic structures of zinc gallogermanate (ZGGO) PLNPs by nonstoichiometric reactions can produce highly uniform nanocubes with controllable size and persistent luminescence. By nonstoichiometric increase of the Ge/Ga ratio in ZGGO, the ZGGO PLNPs were transformed from a mixture of nanocubes and small nanospheres into highly symmetrical and uniform large nanocubes, accompanied by the enhancement of persistent luminescence intensity by about 3.7 times. Moreover, we found that ZGGO PLNPs were responsive to reactive oxygen species (ROS), that is, the persistent luminescence of ZGGO can be quenched by ROS. Autofluorescence-free serum ROS detection was achieved with the developed PLNPs. Further, a biosensing assay for glucose oxidase (GOx) was designed based on the responsiveness of ZGGO PLNPs to H2O2. This study may pave a new way for better control of PLNPs' size, morphology, and persistent luminescence, and it can further promote the applications of PLNPs in areas ranging from theranostics to solar energy utilization.
Collapse
Affiliation(s)
- Shuting Yang
- The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou 215123, China
| | - Wenjing Dai
- The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou 215123, China
| | - Man Tang
- School of Electronic and Electrical Engineering, Wuhan Textile University, Wuhan 430200, China
| | - Jie Wang
- The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou 215123, China
| |
Collapse
|
6
|
Leynaud V, Gillet C, Lavoué R, Concordet D, Reynolds BS. Evaluation of a smartphone-based colorimetric method for urinalysis dipstick readings in cats. J Feline Med Surg 2023; 25:1098612X231171434. [PMID: 37226706 PMCID: PMC10811987 DOI: 10.1177/1098612x231171434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
OBJECTIVES The aim of the study was to compare the diagnostic performances of a smartphone-based colorimetric method (SBCM) for urinalysis with a semi-automated point-of-care (POC) analyser using standardised solutions and cat urine. METHODS Artificial solutions (negative and positive quality controls, and purposely designed artificial urine) and natural urine from 216 cats were used. Two urine reagent strips were simultaneously dipped in each sample. One dipstick was read by the SBCM and the other by the POC analyser at the same time. Results for pH, proteins, bilirubin, 'blood', glucose and ketones were considered. Overall agreement and sensitivity, specificity and accuracy of the SBCM were determined based on selected cut-offs. RESULTS For the artificial solutions, 80 comparisons were obtained for each analyte and each expected concentration. The overall agreement (exactly the same result) between the two methods was 78.4%. SBCM sensitivity, specificity and accuracy were 99.0%, 100% and 99.3%, respectively. The correlation between the two methods was almost perfect (Cohen's kappa coefficient = 0.9851). For natural urine samples, the overall agreement (including pH) was 68.6%. Using optimal cut-offs for the SBCM determined from the results of analysis of artificial solutions, the sensitivity, specificity and accuracy of the SBCM were 100%, 76.02% and 80.5%, respectively. In this situation, the correlation between the two methods was moderate (Cohen's kappa coefficient = 0.5401). This was mostly due to a high rate of false-positive results for bilirubin (61.1%). CONCLUSIONS AND RELEVANCE With proper cut-off use (ie, considering positive or negative results) the SBCM evaluated here has a perfect sensitivity and appropriate diagnostic performances for proteins, 'blood', glucose and ketones. Based on these experimental data, this method appears suitable for dipstick urinalysis but positive results for bilirubin and proteins have to be confirmed.
Collapse
Affiliation(s)
| | - Candice Gillet
- Université de Toulouse, ENVT, Toulouse, Occitanie, France
| | - Rachel Lavoué
- InTheRes, Université de Toulouse, INRAE, ENVT, Toulouse, Occitanie, France
| | - Didier Concordet
- InTheRes, Université de Toulouse, INRAE, ENVT, Toulouse, Occitanie, France
| | - Brice S Reynolds
- InTheRes, Université de Toulouse, INRAE, ENVT, Toulouse, Occitanie, France
| |
Collapse
|
7
|
Bhan R, Pamula R, Faruki P, Gajrani J. Blockchain-enabled secure and efficient data sharing scheme for trust management in healthcare smartphone network. THE JOURNAL OF SUPERCOMPUTING 2023; 79:1-42. [PMID: 37359328 PMCID: PMC10131528 DOI: 10.1007/s11227-023-05272-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 04/04/2023] [Indexed: 06/28/2023]
Abstract
The Internet of Medical Things (IoMT) is an extended genre of the Internet of Things (IoT) where the Things collaborate to provide remote patient health monitoring, also known as the Internet of Health (IoH). Smartphones and IoMTs are expected to maintain secure and trusted confidential patient record exchange while managing the patient remotely. Healthcare organizations deploy Healthcare Smartphone Networks (HSN) for personal patient data collection and sharing among smartphone users and IoMT nodes. However, attackers gain access to confidential patient data via infected IoMT nodes on the HSN. Additionally, attackers can compromise the entire network via malicious nodes. This article proposes a Hyperledger blockchain-based technique to identify compromised IoMT nodes and safeguard sensitive patient records. Furthermore, the paper presents a Clustered Hierarchical Trust Management System (CHTMS) to block malicious nodes. In addition, the proposal employs Elliptic Curve Cryptography (ECC) to protect sensitive health records and is resilient against Denial-Of-Service (DOS) attacks. Finally, the evaluation results show that integrating blockchains into the HSN system improved detection performance compared to the existing state of the art. Therefore, the simulation results indicate better security and reliability when compared to conventional databases.
Collapse
Affiliation(s)
- Rati Bhan
- Department of Computer Science and Engineering, Indian Institute of Technology (ISM), Dhanbad, Dhanbad, 826004 India
| | - Rajendra Pamula
- Department of Computer Science and Engineering, Indian Institute of Technology (ISM), Dhanbad, Dhanbad, 826004 India
| | - Parvez Faruki
- Department of Technical Education, Govt. of Gujarat, Gandhinagar, India
| | - Jyoti Gajrani
- Department of Computer Science and Engineering, Engineering College Ajmer, Ajmer, India
| |
Collapse
|
8
|
Bhalla N, Payam AF. Addressing the Silent Spread of Monkeypox Disease with Advanced Analytical Tools. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2206633. [PMID: 36517107 DOI: 10.1002/smll.202206633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Indexed: 06/17/2023]
Abstract
Monkeypox disease is caused by a virus which belongs to the orthopoxvirus genus of the poxviridae family. This disease has recently spread out to several non-endemic countries. While some cases have been linked to travel from endemic regions, more recent infections are thought to have spread in the community without any travel links, raising the risks of a wider outbreak. This state of public health represents a highly unusual event which requires urgent surveillance. In this context, the opportunities and technological challenges of current bio/chemical sensors, nanomaterials, nanomaterial characterization instruments, and artificially intelligent biosystems collectively called "advanced analytical tools" are reviewed here, which will allow early detection, characterization, and inhibition of the monkeypox virus (MPXV) in the community and limit its expansion from endemic to pandemic. A summary of background information is also provided from biological and epidemiological perspective of monkeypox to support the scientific case for its holistic management using advanced analytical tools.
Collapse
Affiliation(s)
- Nikhil Bhalla
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, York St., BT15 1ED Belfast, Northern Ireland, UK
- Healthcare Technology Hub, Ulster University, York St., BT15 1ED Belfast, Northern Ireland, UK
| | - Amir Farokh Payam
- Nanotechnology and Integrated Bioengineering Centre (NIBEC), School of Engineering, Ulster University, York St., BT15 1ED Belfast, Northern Ireland, UK
- Healthcare Technology Hub, Ulster University, York St., BT15 1ED Belfast, Northern Ireland, UK
| |
Collapse
|
9
|
Recent advances on CRISPR/Cas system-enabled portable detection devices for on-site agri-food safety assay. Trends Food Sci Technol 2022. [DOI: 10.1016/j.tifs.2022.09.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
10
|
He Z, Liu C, Li Z, Chu Z, Chen X, Chen X, Guo Y. Advances in the use of nanomaterials for nucleic acid detection in point-of-care testing devices: A review. Front Bioeng Biotechnol 2022; 10:1020444. [DOI: 10.3389/fbioe.2022.1020444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 09/23/2022] [Indexed: 01/03/2023] Open
Abstract
The outbreak of the coronavirus (COVID-19) has heightened awareness of the importance of quick and easy testing. The convenience, speed, and timely results from point-of-care testing (POCT) in all vitro diagnostic devices has drawn the strong interest of researchers. However, there are still many challenges in the development of POCT devices, such as the pretreatment of samples, detection sensitivity, specificity, and so on. It is anticipated that the unique properties of nanomaterials, e.g., their magnetic, optical, thermal, and electrically conductive features, will address the deficiencies that currently exist in POCT devices. In this review, we mainly analyze the work processes of POCT devices, especially in nucleic acid detection, and summarize how novel nanomaterials used in various aspects of POCT products can improve performance, with the ultimate aims of offering new ideas for the application of nanomaterials and the overall development of POCT devices.
Collapse
|
11
|
Beduk T, Beduk D, Hasan MR, Guler Celik E, Kosel J, Narang J, Salama KN, Timur S. Smartphone-Based Multiplexed Biosensing Tools for Health Monitoring. BIOSENSORS 2022; 12:bios12080583. [PMID: 36004979 PMCID: PMC9406027 DOI: 10.3390/bios12080583] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 07/25/2022] [Accepted: 07/26/2022] [Indexed: 05/24/2023]
Abstract
Many emerging technologies have the potential to improve health care by providing more personalized approaches or early diagnostic methods. In this review, we cover smartphone-based multiplexed sensors as affordable and portable sensing platforms for point-of-care devices. Multiplexing has been gaining attention recently for clinical diagnosis considering certain diseases require analysis of complex biological networks instead of single-marker analysis. Smartphones offer tremendous possibilities for on-site detection analysis due to their portability, high accessibility, fast sample processing, and robust imaging capabilities. Straightforward digital analysis and convenient user interfaces support networked health care systems and individualized health monitoring. Detailed biomarker profiling provides fast and accurate analysis for disease diagnosis for limited sample volume collection. Here, multiplexed smartphone-based assays with optical and electrochemical components are covered. Possible wireless or wired communication actuators and portable and wearable sensing integration for various sensing applications are discussed. The crucial features and the weaknesses of these devices are critically evaluated.
Collapse
Affiliation(s)
- Tutku Beduk
- Silicon Austria Labs GmbH: Sensor Systems, 9524 Villach, Austria;
| | - Duygu Beduk
- Central Research Test and Analysis Laboratory Application and Research Center, Ege University, 35100 Izmir, Turkey;
| | - Mohd Rahil Hasan
- Department of Biotechnology, Jamia Hamdard, New Delhi 110062, India; (M.R.H.); (J.N.)
| | - Emine Guler Celik
- Department of Bioengineering, Faculty of Engineering, Ege University, 35100 Izmir, Turkey;
| | - Jurgen Kosel
- Silicon Austria Labs GmbH: Sensor Systems, 9524 Villach, Austria;
| | - Jagriti Narang
- Department of Biotechnology, Jamia Hamdard, New Delhi 110062, India; (M.R.H.); (J.N.)
| | - Khaled Nabil Salama
- Sensors Lab, Advanced Membranes and Porous Materials Center, Computer, Electrical and Mathematical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia;
| | - Suna Timur
- Central Research Test and Analysis Laboratory Application and Research Center, Ege University, 35100 Izmir, Turkey;
- Department of Biochemistry, Faculty of Science, Ege University, 35100 Izmir, Turkey
| |
Collapse
|
12
|
Use of Cysteamine and Glutaraldehyde Chemicals for Robust Functionalization of Substrates with Protein Biomarkers—An Overview on the Construction of Biosensors with Different Transductions. BIOSENSORS 2022; 12:bios12080581. [PMID: 36004978 PMCID: PMC9406156 DOI: 10.3390/bios12080581] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Revised: 07/21/2022] [Accepted: 07/27/2022] [Indexed: 11/17/2022]
Abstract
Currently, several biosensors are reported to confirm the absence/presence of an abnormal level of specific human biomarkers in research laboratories. Unfortunately, public marketing and/or pharmacy accessibility are not yet possible for many bodily fluid biomarkers. The questions are numerous, starting from the preparation of the substrates, the wet/dry form of recognizing the (bio)ligands, the exposure time, and the choice of the running buffers. In this context, for the first time, the present overview summarizes the pre-functionalization of standard and nanostructured solid/flexible supports with cysteamine (Cys) and glutaraldehyde (GA) chemicals for robust protein immobilization and detection of biomarkers in body fluids (serum, saliva, and urine) using three transductions: piezoelectrical, electrochemical, and optical, respectively. Thus, the reader can easily access and compare step-by-step conjugate protocols published over the past 10 years. In conclusion, Cys/GA chemistry seems widely used for electrochemical sensing applications with different types of recorded signals, either current, potential, or impedance. On the other hand, piezoelectric detection via quartz crystal microbalance (QCM) and optical detection by surface plasmon resonance (LSPR)/surface-enhanced Raman spectroscopy (SERS) are ultrasensitive platforms and very good candidates for the miniaturization of medical devices in the near future.
Collapse
|