1
|
Jin J, Zhou Y, Chen L, Chen Z. Ultrafast T 2 and T 2* mapping using single-shot spatiotemporally encoded MRI with reduced field of view and spiral out-in-out-in trajectory. Med Phys 2024; 51:7308-7319. [PMID: 38896823 DOI: 10.1002/mp.17268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 05/15/2024] [Accepted: 06/11/2024] [Indexed: 06/21/2024] Open
Abstract
BACKGROUND T2 and T2* mapping are crucial components of quantitative magnetic resonance imaging, offering valuable insights into tissue characteristics and pathology. Single-shot methods can achieve ultrafast T2 or T2* mapping by acquiring multiple readout echo trains. However, the extended echo trains pose challenges, such as compromised image quality and diminished quantification accuracy. PURPOSE In this study, we develop a single-shot method for ultrafast T2 and T2* mapping with reduced echo train length. METHODS The proposed method is based on ultrafast single-shot spatiotemporally encoded (SPEN) MRI combined with reduced field of view (FOV) and spiral out-in-out-in (OIOI) trajectory. Specifically, a biaxial SPEN excitation scheme was employed to excite the spin signal into the spatiotemporal encoding domain. The OIOI trajectory with high acquisition efficiency was employed to acquire signals within targeted reduced FOV. Through non-Cartesian super-resolved (SR) reconstruction, 12 aliasing-free images with different echo times were obtained within 150 ms. These images were subsequently fitted to generate T2 or T2* mapping simultaneously using a derived model. RESULTS Accurate and co-registered T2 and T2* maps were generated, closely resembling the reference maps. Numerical simulations demonstrated substantial consistency (R2 > 0.99) with the ground truth values. A mean difference of 0.6% and 1.7% was observed in T2 and T2*, respectively, in in vivo rat brain experiments compared to the reference. Moreover, the proposed method successfully obtained T2 and T2* mappings of rat kidney in free-breathing mode, demonstrating its superiority over multishot methods lacking respiratory navigation. CONCLUSIONS The results suggest that the proposed method can achieve ultrafast and accurate T2 and T2* mapping, potentially facilitating the application of T2 and T2* mapping in scenarios requiring high temporal resolution.
Collapse
Affiliation(s)
- Junxian Jin
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Yang Zhou
- Key Laboratory for Magnetic Resonance and Multimodality Imaging of Guangdong Province, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, School of Electronic Science and Engineering, National Model Microelectronics College, Xiamen University, Xiamen, China
| |
Collapse
|
2
|
Ma L, Otikovs M, Cousin SF, Liberman G, Bao Q, Frydman L. Simultaneous multi-banding and multi-echo phase encoding for the accelerated acquisition of high-resolution volumetric diffusivity maps by spatiotemporally encoded MRI. Magn Reson Imaging 2021; 79:130-139. [PMID: 33744384 DOI: 10.1016/j.mri.2021.03.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 03/12/2021] [Accepted: 03/13/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE Spatiotemporal Encoding (SPEN) is an ultrafast imaging technique where the low-bandwidth axis is rasterized in a joint spatial/k-domain. SPEN benefits from increased robustness to field inhomogeneities, folding-free reconstruction of subsampled data, and an ability to combine multiple interleaved or signal averaged scans -yet its relatively high SAR complicates volumetric uses. Here we show how this can be alleviated by merging simultaneous multi-band excitation, with intra-slab multi-echo (ME) phase encoding, for the acquisition of high definition volumetric DWI/DTI data. METHODS A protocol involving phase-cycling of simultaneous multi-banded z-slab excitations in independently ky-interleaved scans, together with ME trains that kz-encoded positions within these slabs, was implemented. A reconstruction incorporating a CAIPIRINHA-like encoding of the multiple bands and exploiting SPEN's ability to deliver self-referenced, per-shot phase maps, then led to high-definition diffusivity acquisitions, with reduced SAR and acquisition times vis-à-vis non-optimized 3D counterparts. RESULTS The new protocol was used to collect full brain 3 T DTI experiments at a variety of nominal voxel sizes, ranging from 1.95 to 2.54 mm3. In general, the new protocol yielded superior sensitivity and fewer distortions than what could be observed in comparably timed phase-encoded 3D SPEN, multi-slice 2D SPEN, or optimized EPI counterparts. CONCLUSIONS A robust procedure for acquiring volumetric DWI/DTI data was developed and demonstrated.
Collapse
Affiliation(s)
- Lingceng Ma
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel; College of Electronic Science and Technology, Xiamen University, Xiamen, China
| | - Martins Otikovs
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Samuel F Cousin
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel; Centre de RMN à Très Haut Champs, Lyon, France
| | - Gilad Liberman
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel; Massachusetts General Hospital, Boston, USA
| | - Qingjia Bao
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel; Wuhan Center for Magnetic Resonance, Chinese Academy of Sciences, Wuhan 430071, China
| | - Lucio Frydman
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel.
| |
Collapse
|
3
|
Cousin SF, Liberman G, Solomon E, Otikovs M, Frydman L. A regularized reconstruction pipeline for high‐definition diffusion MRI in challenging regions incorporating a per‐shot image correction. Magn Reson Med 2019; 82:1322-1330. [DOI: 10.1002/mrm.27802] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 04/09/2019] [Accepted: 04/16/2019] [Indexed: 12/20/2022]
Affiliation(s)
- Samuel F. Cousin
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Gilad Liberman
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Eddy Solomon
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Martins Otikovs
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Lucio Frydman
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| |
Collapse
|
4
|
Multiple-coil k
-space interpolation enhances resolution in single-shot spatiotemporal MRI. Magn Reson Med 2017; 79:796-805. [DOI: 10.1002/mrm.26731] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Revised: 04/02/2017] [Accepted: 04/03/2017] [Indexed: 12/17/2022]
|
5
|
Chen L, Huang J, Zhang T, Li J, Cai C, Cai S. Variable density sampling and non-Cartesian super-resolved reconstruction for spatiotemporally encoded single-shot MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016; 272:1-9. [PMID: 27591366 DOI: 10.1016/j.jmr.2016.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 08/14/2016] [Accepted: 08/26/2016] [Indexed: 06/06/2023]
Abstract
Spatiotemporally encoded (SPEN) single-shot MRI is an emerging ultrafast technique, which is capable of spatially selective acquisition and reduced field-of-view imaging. Compared to uniform sampling, variable density sampling has great potential in reducing aliasing artifacts and improving sampling efficiency. In this study, variable density spiral trajectory and non-Cartesian super-resolved (SR) reconstruction method are developed for SPEN MRI. The gradient waveforms design of spiral trajectory is mathematically described as an optimization problem subjected to the limitations of hardware. Non-Cartesian SR reconstruction with specific gridding method is developed to retrieve a resolution enhanced image from raw SPEN data. The robustness and efficiency of the proposed methods are demonstrated by numerical simulation and various experiments. The results indicate that variable density SPEN MRI can provide better spatial resolution and fewer aliasing artifacts compared to Cartesian counterpart. The proposed methods will facilitate the development of variable density SPEN MRI.
Collapse
Affiliation(s)
- Lin Chen
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China; Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21205, United States.
| | - Jianpan Huang
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| | - Ting Zhang
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| | - Jing Li
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| | - Congbo Cai
- Department of Communication Engineering, Xiamen University, Xiamen 361005, China.
| | - Shuhui Cai
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
6
|
Huang J, Zhang M, Lu J, Cai C, Chen L, Cai S. A fast chemical exchange saturation transfer imaging scheme based on single-shot spatiotemporal encoding. Magn Reson Med 2016; 77:1786-1796. [PMID: 27120691 DOI: 10.1002/mrm.26258] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2016] [Revised: 03/30/2016] [Accepted: 04/01/2016] [Indexed: 01/31/2023]
Abstract
PURPOSE To design a new approach that can not only keep the spatial and temporal resolution but also have better built-in immunity to magnetic field inhomogeneity and chemical shift effects than the single-shot echo planar imaging (EPI) for chemical exchange saturation transfer (CEST) MRI. METHOD The single-shot spatiotemporally encoded (SPEN) MRI sequence was combined with a continuous wave saturation pulse for fast CEST MRI (CEST-SPEN MRI). The resulting images were super-resolved reconstructed by a hybrid method that solves the l1 norm minimization together with total variation (TV) regularization. Partial Lorentzian fitting was used to analyze the subsequent Z-spectra. RESULTS Experimental results of a creatine phantom and in vivo tumor rat brains show that CEST-SPEN MRI has good capability in providing CEST-based and NOE-based contrast images. CONCLUSIONS Compared with CEST-EPI, CEST-SPEN MRI has better immunity to magnetic field inhomogeneity and provides better contrast images within identical acquisition time, especially under an identical inhomogeneous field. Magn Reson Med 77:1786-1796, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Jianpan Huang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Miao Zhang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Jianhua Lu
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.,Meizhouwan Vocational Technology College, Putian, China
| | - Congbo Cai
- Department of Communication Engineering, Xiamen University, Xiamen, China
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| |
Collapse
|
7
|
Zhang Z, Seginer A, Frydman L. Single-scan MRI with exceptional resilience to field heterogeneities. Magn Reson Med 2016; 77:623-634. [PMID: 26901840 DOI: 10.1002/mrm.26145] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Revised: 12/15/2015] [Accepted: 01/07/2016] [Indexed: 01/01/2023]
Abstract
PURPOSE Single-scan two-dimensional MRI has been generally constrained to acquisitions in high quality magnets. This study introduces a methodology, cross-term spatiotemporal encoding (xSPEN), that delivers such images under much poorer external field conditions. METHODS xSPEN departs from conventional k-space scanning, by relying on spatiotemporally encoding the image being sought. Unlike hitherto proposed SPEN methods, however, xSPEN's image readout does not take place using a field gradient along the direction being probed, but rather with the aid of an ancillary source of inhomogeneous frequency broadening. This ancillary dimension was here imposed by an orthogonal field gradient; for example, images along the "y" axis were read out by application of a "z" gradient. The principles and characteristics of this new approach, compatible with existing scanners and free from the need to collect auxiliary information such as field maps, are presented and discussed. RESULTS Single- and multi-slice in vitro, ex vivo, and in vivo MRI experiments, confirmed the unusual resilience of this new single-shot MRI method to multiple chemical sites on phantoms, animals and humans. CONCLUSION xSPEN can deliver single-scan MRI with good sensitivity and exceptional resilience to field inhomogeneities. This could enable investigations that have hitherto escaped from MRI's scope. Magn Reson Med 77:623-634, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Zhiyong Zhang
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, Fujian, China
| | - Amir Seginer
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Lucio Frydman
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
8
|
Schmidt R, Mishkovsky M, Hyacinthe JN, Kunz N, Gruetter R, Comment A, Frydman L. Correcting surface coil excitation inhomogeneities in single-shot SPEN MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2015; 259:199-206. [PMID: 26363583 PMCID: PMC5035682 DOI: 10.1016/j.jmr.2015.08.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2015] [Revised: 08/25/2015] [Accepted: 08/26/2015] [Indexed: 05/08/2023]
Abstract
Given their high sensitivity and ability to limit the field of view (FOV), surface coils are often used in magnetic resonance spectroscopy (MRS) and imaging (MRI). A major downside of surface coils is their inherent radiofrequency (RF) B1 heterogeneity across the FOV, decreasing with increasing distance from the coil and giving rise to image distortions due to non-uniform spatial responses. A robust way to compensate for B1 inhomogeneities is to employ adiabatic inversion pulses, yet these are not well adapted to all imaging sequences - including to single-shot approaches like echo planar imaging (EPI). Hybrid spatiotemporal encoding (SPEN) sequences relying on frequency-swept pulses provide another ultrafast MRI alternative, that could help solve this problem thanks to their built-in heterogeneous spatial manipulations. This study explores how this intrinsic SPEN-based spatial discrimination, could be used to compensate for the B1 inhomogeneities inherent to surface coils. Experiments carried out in both phantoms and in vivo rat brains demonstrate that, by suitably modulating the amplitude of a SPEN chirp pulse that progressively excites the spins in a direction normal to the coil, it is possible to compensate for the RF transmit inhomogeneities and thus improve sensitivity and image fidelity.
Collapse
Affiliation(s)
- Rita Schmidt
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Mor Mishkovsky
- Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Jean-Noel Hyacinthe
- School of health, University of Applied Sciences and Arts Western Switzerland, Geneva, Switzerland
| | - Nicolas Kunz
- Center of Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Rolf Gruetter
- Laboratory of Functional and Metabolic Imaging, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
- Center of Biomedical Imaging (CIBM), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Arnaud Comment
- Institute of the Physics of Biological Systems, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | - Lucio Frydman
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
9
|
Chen L, Li J, Zhang M, Cai S, Zhang T, Cai C, Chen Z. Super-resolved enhancing and edge deghosting (SEED) for spatiotemporally encoded single-shot MRI. Med Image Anal 2015; 23:1-14. [DOI: 10.1016/j.media.2015.03.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 02/12/2015] [Accepted: 03/10/2015] [Indexed: 10/23/2022]
|
10
|
Schmidt R, Seginer A, Frydman L. Interleaved multishot imaging by spatiotemporal encoding: A fast, self-referenced method for high-definition diffusion and functional MRI. Magn Reson Med 2015; 75:1935-48. [DOI: 10.1002/mrm.25742] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Revised: 03/31/2015] [Accepted: 03/31/2015] [Indexed: 12/29/2022]
Affiliation(s)
- Rita Schmidt
- Chemical Physics Department; Weizmann Institute of Science; Rehovot Israel
| | - Amir Seginer
- Chemical Physics Department; Weizmann Institute of Science; Rehovot Israel
| | - Lucio Frydman
- Chemical Physics Department; Weizmann Institute of Science; Rehovot Israel
| |
Collapse
|
11
|
Ciobanu L, Solomon E, Pyatigorskaya N, Roussel T, Le Bihan D, Frydman L. fMRI contrast at high and ultrahigh magnetic fields: Insight from complementary methods. Neuroimage 2015; 113:37-43. [DOI: 10.1016/j.neuroimage.2015.03.018] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 03/08/2015] [Accepted: 03/09/2015] [Indexed: 11/27/2022] Open
|
12
|
Chen Y, Chen S, Zhong J, Chen Z. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2015; 254:1-9. [PMID: 25768263 DOI: 10.1016/j.jmr.2015.02.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2014] [Revised: 02/05/2015] [Accepted: 02/09/2015] [Indexed: 06/04/2023]
Abstract
This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.
Collapse
Affiliation(s)
- Ying Chen
- Department of Electronic Science, Fijian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China; Center for Brain Imaging Science and Technology, Zhejiang University, Hangzhou, China
| | - Song Chen
- Center for Brain Imaging Science and Technology, Zhejiang University, Hangzhou, China
| | - Jianhui Zhong
- Center for Brain Imaging Science and Technology, Zhejiang University, Hangzhou, China.
| | - Zhong Chen
- Department of Electronic Science, Fijian Provincial Key Laboratory of Plasma and Magnetic Resonance, State Key Laboratory of Physical Chemistry of Solid Surfaces, Xiamen University, Xiamen, China.
| |
Collapse
|
13
|
Li J, Zhang M, Chen L, Cai C, Sun H, Cai S. Reduced field-of-view imaging for single-shot MRI with an amplitude-modulated chirp pulse excitation and Fourier transform reconstruction. Magn Reson Imaging 2015; 33:503-15. [PMID: 25721996 DOI: 10.1016/j.mri.2015.02.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 01/21/2015] [Accepted: 02/16/2015] [Indexed: 11/18/2022]
Abstract
PURPOSE We employ an amplitude-modulated chirp pulse to selectively excite spins in one or more regions of interest (ROIs) to realize reduced field-of-view (rFOV) imaging based on single-shot spatiotemporally encoded (SPEN) sequence and Fourier transform reconstruction. MATERIALS AND METHODS The proposed rFOV imaging method was theoretically analyzed and illustrated with numerical simulation and tested with phantom experiments and in vivo rat experiments. In addition, point spread function was applied to demonstrate the feasibility of the proposed method. To evaluate the proposed method, the rFOV results were compared with those obtained using the EPI method with orthogonal RF excitation. RESULTS The simulation and experimental results show that the proposed method can image one or two separated ROIs along the SPEN dimension in a single shot with higher spatial resolution, less sensitive to field inhomogeneity, and practically no aliasing artifacts. In addition, the proposed method may produce rFOV images with comparable signal-to-noise ratio to the rFOV EPI images. CONCLUSION The proposed method is promising for the applications under severe susceptibility heterogeneities and for imaging separate ROIs simultaneously.
Collapse
Affiliation(s)
- Jing Li
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Miao Zhang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Congbo Cai
- Department of Communication Engineering, Xiamen University, Xiamen, China.
| | - Huijun Sun
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| |
Collapse
|