Zulkarnain NIH, Sadeghi-Tarakameh A, Thotland J, Harel N, Eryaman Y. A workflow for predicting radiofrequency-induced heating around bilateral deep brain stimulation electrodes in MRI. Med Phys 2024; 51:1007-1018. [PMID: 38153187 PMCID: PMC10922480 DOI: 10.1002/mp.16913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 10/04/2023] [Accepted: 12/10/2023] [Indexed: 12/29/2023] Open
Abstract
BACKGROUND Heating around deep brain stimulation (DBS) in magnetic resonance imaging (MRI) occurs when the time-varying electromagnetic (EM) fields induce currents in the electrodes which can generate heat and potentially cause tissue damage. Predicting the heating around the electrode contacts is important to ensure the safety of patients with DBS implants undergoing an MRI scan. We previously proposed a workflow to predict heating around DBS contacts and introduced a parameter, equivalent transimpedance, that is independent of electrode trajectories, termination, and radiofrequency (RF) excitations. The workflow performance was validated in a unilateral DBS system. PURPOSE To predict RF heating around the contacts of bilateral (DBS) electrodes during an MRI scan in an anthropomorphic head phantom. METHODS Bilateral electrodes were fixed in a skull phantom filled with hydroxyethyl cellulose (HEC) gel. The electrode shafts were suspended extracranially, in a head and torso phantom filled with the same gel material. The current induced on the electrode shaft was experimentally measured using an MR-based technique 3 cm above the tip. A transimpedance value determined in a previous offline calibration was used to scale the shaft current and calculate the contact voltage. The voltage was assigned as a boundary condition on the electrical contacts of the electrode in a quasi-static (EM) simulation. The resulting specific absorption rate (SAR) distribution became the input for a transient thermal simulation and was used to predict the heating around the contacts. RF heating experiments were performed for eight different lead trajectories using circularly polarized (CP) excitation and two linear excitations for one trajectory. The measured temperatures for all experiments were compared with the simulated temperatures and the root-mean-squared errors (RMSE) were calculated. RESULTS The RF heating around the contacts of both bilateral electrodes was predicted with ≤ 0.29°C of RMSE for 20 heating scenarios. CONCLUSION The workflow successfully predicted the heating for different bilateral DBS trajectories and excitation patterns in an anthropomorphic head phantom.
Collapse
Affiliation(s)
- Nur Izzati Huda Zulkarnain
- Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, 55455, USA
| | - Alireza Sadeghi-Tarakameh
- Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, 55455, USA
| | - Jeromy Thotland
- Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, 55455, USA
| | - Noam Harel
- Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, 55455, USA
| | - Yigitcan Eryaman
- Center for Magnetic Resonance Research (CMRR), University of Minnesota, Minneapolis, Minnesota, 55455, USA
| |
Collapse
|
2
|
Lottner T, Reiss S, Rieger SB, Schuettler M, Fischer J, Bielak L, Özen AC, Bock M. Radio-frequency induced heating of intra-cranial EEG electrodes: The more the colder? Neuroimage 2022; 264:119691. [PMID: 36375783 DOI: 10.1016/j.neuroimage.2022.119691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 09/20/2022] [Accepted: 10/16/2022] [Indexed: 11/13/2022] Open
Abstract
Many neurological disorders are analyzed and treated with implantable electrodes. Many patients with such electrodes have to undergo MRI examinations - often unrelated to their implant - at the risk of radio-frequency induced heating. The number of electrode contact sites of these implants keeps increasing due to improvements in manufacturing and computational algorithms. Electrode grids with multiple receive channels couple to the RF fields present in MRI, but, due to their proximity, a combination of leads has a coupling response which is not a superposition of the individual leads' response. To investigate the problem of RF-induced heating of coupled multi-lead implants, temperature mapping was performed on a set of intra-cranial electroencephalogram (icEEG) electrode grid prototypes with increasing number of contact sites (1-16). Additionally, electric field measurements were used to investigate the radio-frequency heating characteristics of the implants in different media combinations, simulating the device being partially immersed inside the patient. MR measurements show RF-induced heating up to 19.6 K for the single electrode, reducing monotonically with larger number of contact sites to a minimum of 0.9 K for the largest grid. The SAR calculated from temperature measurements agrees well with electric field mapping: The same trend is visible for different insertion lengths, however, the energy dissipated by the whole implant varies with the grid size and insertion length. Thus, in the tested circumstances, a larger electrode number either reduced or had a similar risk of RF induced heating, indicating, that the size of electrode grids is a design parameter, which can be used to change an implants RF response and in turn to reduce the risk of RF induced heating and improve the safety of patient with neuro-implants undergoing MRI examinations.
Collapse
Affiliation(s)
- Thomas Lottner
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Simon Reiss
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | | | - Johannes Fischer
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Lars Bielak
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ali C Özen
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Bock
- Division of Medical Physics, Department of Diagnostic and Interventional Radiology, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| |
Collapse
|
3
|
Tesfai AS, Vollmer A, Özen AC, Braig M, Semper-Hogg W, Altenburger MJ, Ludwig U, Bock M. Inductively Coupled Intraoral Flexible Coil for Increased Visibility of Dental Root Canals in Magnetic Resonance Imaging. Invest Radiol 2022; 57:163-170. [PMID: 34510099 DOI: 10.1097/rli.0000000000000826] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Accurate visualization of dental root canals is vital for the correct diagnosis and subsequent treatment. This work assesses the improvement of a dedicated new coil for dental magnetic resonance imaging (MRI) in comparison to conventional ones in terms of signal-to-noise ratio (SNR) and visibility. MATERIALS AND METHODS A newly developed intraoral flexible coil was used to display dental roots with MRI, and it provides improved sensitivity with a loop design and size adjusted to a single tooth anatomy. Ex vivo and in vivo measurements were performed on a 3 T clinical MR system, and results were compared with conventional head and surface coil images. Additional comparison was performed with a modified fast spin echo sequence and a constructive interference in steady-state sequence. RESULTS Ex vivo, an SNR gain of 6.3 could be achieved with the intraoral flexible coil setup, and higher visibility down to 200 μm was possible, whereas the external loop coil is limited to 400 μm. In vivo measurements in a volunteer resulted in an SNR gain of up to 4.5 with an improved delineation of the root canals, especially for the branch tissue splitting of the mesial root canal into mesial-buccal and mesial-lingual. CONCLUSIONS In summary, we showed the feasibility of implementing a wireless coil approach with readily available dental practice materials for sealing and placement. Highly improved MRI scans can be acquired within clinically feasible scan times, and this might provide additional medical findings to supplement available x-ray images.
Collapse
Affiliation(s)
| | - Andreas Vollmer
- Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg
| | | | | | - Wiebke Semper-Hogg
- Department of Oral and Craniomaxillofacial Surgery, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg
| | - Markus Jörg Altenburger
- Department of Operative Dentistry and Periodontology, Center for Dental Medicine, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Ute Ludwig
- From the Department of Radiology, Medical Physics
| | - Michael Bock
- From the Department of Radiology, Medical Physics
| |
Collapse
|
4
|
Zhang Y, Le S, Li H, Ji B, Wang MH, Tao J, Liang JQ, Zhang XY, Kang XY. MRI magnetic compatible electrical neural interface: From materials to application. Biosens Bioelectron 2021; 194:113592. [PMID: 34507098 DOI: 10.1016/j.bios.2021.113592] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2021] [Accepted: 08/24/2021] [Indexed: 01/07/2023]
Abstract
Neural electrical interfaces are important tools for local neural stimulation and recording, which potentially have wide application in the diagnosis and treatment of neural diseases, as well as in the transmission of neural activity for brain-computer interface (BCI) systems. At the same time, magnetic resonance imaging (MRI) is one of the effective and non-invasive techniques for recording whole-brain signals, providing details of brain structures and also activation pattern maps. Simultaneous recording of extracellular neural signals and MRI combines two expressions of the same neural activity and is believed to be of great importance for the understanding of brain function. However, this combination makes requests on the magnetic and electronic performance of neural interface devices. MRI-compatibility refers here to a technological approach to simultaneous MRI and electrode recording or stimulation without artifacts in imaging. Trade-offs between materials magnetic susceptibility selection and electrical function should be considered. Herein, prominent trends in selecting materials of suitable magnetic properties are analyzed and material design, function and application of neural interfaces are outlined together with the remaining challenge to fabricate MRI-compatible neural interface.
Collapse
Affiliation(s)
- Yuan Zhang
- Laboratory for Neural Interface and Brain Computer Interface, Institute of AI and Robotics, Academy for Engineering and Technology, FUDAN University, 220 Handan Rd., Yangpu District, Shanghai, 200433, China; Ji Hua Laboratory, 28 Island Ring South Rd., Foshan City, 528200, China; Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, Shanghai 200433, China; Research Center for Intelligent Sensing, Zhejiang Lab, Hangzhou, 311100, China; Yiwu Research Institute of Fudan University, Chengbei Road, Yiwu City, 322000, Zhejiang, China
| | - Song Le
- Laboratory for Neural Interface and Brain Computer Interface, Institute of AI and Robotics, Academy for Engineering and Technology, FUDAN University, 220 Handan Rd., Yangpu District, Shanghai, 200433, China; Ji Hua Laboratory, 28 Island Ring South Rd., Foshan City, 528200, China; Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, Shanghai 200433, China; Research Center for Intelligent Sensing, Zhejiang Lab, Hangzhou, 311100, China; Yiwu Research Institute of Fudan University, Chengbei Road, Yiwu City, 322000, Zhejiang, China
| | - Hui Li
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, 1068 Xueyuan Avenue, Shenzhen University Town, Shenzhen, 518055, China
| | - Bowen Ji
- Unmanned System Research Institute; Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, Xi'an, 710072, China
| | - Ming-Hao Wang
- The MOE Engineering Research Center of Smart Microsensors and Microsystems, School of Electronics & Information, Hangzhou Dianzi University, Hangzhou, 310018, China
| | - Jin Tao
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin, 130033, China
| | - Jing-Qiu Liang
- State Key Laboratory of Applied Optics, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin, 130033, China
| | - Xiao-Yong Zhang
- Institute of Science and Technology for Brain-inspired Intelligence, FUDAN University, Shanghai, 200433, China; Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence (Fudan University), Ministry of Education, Shanghai 200433, China
| | - Xiao-Yang Kang
- Laboratory for Neural Interface and Brain Computer Interface, Institute of AI and Robotics, Academy for Engineering and Technology, FUDAN University, 220 Handan Rd., Yangpu District, Shanghai, 200433, China; Ji Hua Laboratory, 28 Island Ring South Rd., Foshan City, 528200, China; Engineering Research Center of AI & Robotics, Ministry of Education, Shanghai Engineering Research Center of AI & Robotics, MOE Frontiers Center for Brain Science, Shanghai 200433, China; Research Center for Intelligent Sensing, Zhejiang Lab, Hangzhou, 311100, China; Yiwu Research Institute of Fudan University, Chengbei Road, Yiwu City, 322000, Zhejiang, China.
| |
Collapse
|
5
|
Erhardt JB, Lottner T, Pasluosta CF, Gessner I, Mathur S, Schuettler M, Bock M, Stieglitz T. Fabrication and validation of reference structures for the localization of subdural standard- and micro-electrodes in MRI. J Neural Eng 2020; 17:046044. [PMID: 32764195 DOI: 10.1088/1741-2552/abad7a] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Report simple reference structure fabrication and validate the precise localization of subdural micro- and standard electrodes in magnetic resonance imaging (MRI) in phantom experiments. APPROACH Electrode contacts with diameters of 0.3 mm and 4 mm are localized in 1.5 T MRI using reference structures made of silicone and iron oxide nanoparticle doping. The precision of the localization procedure was assessed for several standard MRI sequences and implant orientations in phantom experiments and compared to common clinical localization procedures. MAIN RESULTS A localization precision of 0.41 ± 0.20 mm could be achieved for both electrode diameters compared to 1.46 ± 0.69 mm that was achieved for 4 mm standard electrode contacts localized using a common clinical standard method. The new reference structures are intrinsically bio-compatible, and they can be detected with currently available feature detection software so that a clinical implementation of this technology should be feasible. SIGNIFICANCE Neuropathologies are increasingly diagnosed and treated with subdural electrodes, where the exact localization of the electrode contacts with respect to the patient's cortical anatomy is a prerequisite for the procedure. Post-implantation electrode localization using MRI may be advantageous compared to the common alternative of CT-MRI image co-registration, as it avoids systematic localization errors associated with the co-registration itself, as well as brain shift and implant movement. Additionally, MRI provides superior soft tissue contrast for the identification of brain lesions without exposing the patient to ionizing radiation. Recent studies show that smaller electrodes and high-density electrode grids are ideal for clinical and research purposes, but the localization of these devices in MRI has not been demonstrated.
Collapse
Affiliation(s)
- Johannes B Erhardt
- Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany. BrainLinks-BrainTools, Freiburg, Germany
| | | | | | | | | | | | | | | |
Collapse
|