Singh R, Singh N, Kaur L. Deep learning methods for 3D magnetic resonance image denoising, bias field and motion artifact correction: a comprehensive review. Phys Med Biol 2024; 69:23TR01. [PMID: 39569887 DOI: 10.1088/1361-6560/ad94c7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2024] [Accepted: 11/19/2024] [Indexed: 11/22/2024]
Abstract
Magnetic resonance imaging (MRI) provides detailed structural information of the internal body organs and soft tissue regions of a patient in clinical diagnosis for disease detection, localization, and progress monitoring. MRI scanner hardware manufacturers incorporate various post-acquisition image-processing techniques into the scanner's computer software tools for different post-processing tasks. These tools provide a final image of adequate quality and essential features for accurate clinical reporting and predictive interpretation for better treatment planning. Different post-acquisition image-processing tasks for MRI quality enhancement include noise removal, motion artifact reduction, magnetic bias field correction, and eddy electric current effect removal. Recently, deep learning (DL) methods have shown great success in many research fields, including image and video applications. DL-based data-driven feature-learning approaches have great potential for MR image denoising and image-quality-degrading artifact correction. Recent studies have demonstrated significant improvements in image-analysis tasks using DL-based convolutional neural network techniques. The promising capabilities and performance of DL techniques in various problem-solving domains have motivated researchers to adapt DL methods to medical image analysis and quality enhancement tasks. This paper presents a comprehensive review of DL-based state-of-the-art MRI quality enhancement and artifact removal methods for regenerating high-quality images while preserving essential anatomical and physiological feature maps without destroying important image information. Existing research gaps and future directions have also been provided by highlighting potential research areas for future developments, along with their importance and advantages in medical imaging.
Collapse
Affiliation(s)
- Ram Singh
- Department of Computer Science & Engineering, Punjabi University, Chandigarh Road, Patiala 147002, Punjab, India
| | - Navdeep Singh
- Department of Computer Science & Engineering, Punjabi University, Chandigarh Road, Patiala 147002, Punjab, India
| | - Lakhwinder Kaur
- Department of Computer Science & Engineering, Punjabi University, Chandigarh Road, Patiala 147002, Punjab, India
| |
Collapse
|
2
|
Motyka S, Weiser P, Bachrata B, Hingerl L, Strasser B, Hangel G, Niess E, Niess F, Zaitsev M, Robinson SD, Langs G, Trattnig S, Bogner W. Predicting dynamic, motion-related changes in B 0 field in the brain at a 7T MRI using a subject-specific fine-trained U-net. Magn Reson Med 2024; 91:2044-2056. [PMID: 38193276 DOI: 10.1002/mrm.29980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 11/28/2023] [Accepted: 11/30/2023] [Indexed: 01/10/2024]
Abstract
PURPOSE Subject movement during the MR examination is inevitable and causes not only image artifacts but also deteriorates the homogeneity of the main magnetic field (B0 ), which is a prerequisite for high quality data. Thus, characterization of changes to B0 , for example induced by patient movement, is important for MR applications that are prone to B0 inhomogeneities. METHODS We propose a deep learning based method to predict such changes within the brain from the change of the head position to facilitate retrospective or even real-time correction. A 3D U-net was trained on in vivo gradient-echo brain 7T MRI data. The input consisted of B0 maps and anatomical images at an initial position, and anatomical images at a different head position (obtained by applying a rigid-body transformation on the initial anatomical image). The output consisted of B0 maps at the new head positions. We further fine-trained the network weights to each subject by measuring a limited number of head positions of the given subject, and trained the U-net with these data. RESULTS Our approach was compared to established dynamic B0 field mapping via interleaved navigators, which suffer from limited spatial resolution and the need for undesirable sequence modifications. Qualitative and quantitative comparison showed similar performance between an interleaved navigator-equivalent method and proposed method. CONCLUSION It is feasible to predict B0 maps from rigid subject movement and, when combined with external tracking hardware, this information could be used to improve the quality of MR acquisitions without the use of navigators.
Collapse
Affiliation(s)
- Stanislav Motyka
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Paul Weiser
- Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Beata Bachrata
- Department of Medical Engineering, Carinthia University of Applied Sciences, Klagenfurt, Austria
| | - Lukas Hingerl
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Bernhard Strasser
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Gilbert Hangel
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Department of Neurosurgery, Medical University of Vienna, Vienna, Austria
| | - Eva Niess
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Fabian Niess
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Maxim Zaitsev
- Department of Radiology - Medical Physics, University of Freiburg, Freiburg, Germany
- Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Germany
| | - Simon Daniel Robinson
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Georg Langs
- Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Siegfried Trattnig
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Bogner
- High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| |
Collapse
|
3
|
Wu B, Li C, Zhang J, Lai H, Feng Q, Huang M. Unsupervised dual-domain disentangled network for removal of rigid motion artifacts in MRI. Comput Biol Med 2023; 165:107373. [PMID: 37611424 DOI: 10.1016/j.compbiomed.2023.107373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 07/28/2023] [Accepted: 08/12/2023] [Indexed: 08/25/2023]
Abstract
Motion artifacts in magnetic resonance imaging (MRI) have always been a serious issue because they can affect subsequent diagnosis and treatment. Supervised deep learning methods have been investigated for the removal of motion artifacts; however, they require paired data that are difficult to obtain in clinical settings. Although unsupervised methods are widely proposed to fully use clinical unpaired data, they generally focus on anatomical structures generated by the spatial domain while ignoring phase error (deviations or inaccuracies in phase information that are possibly caused by rigid motion artifacts during image acquisition) provided by the frequency domain. In this study, a 2D unsupervised deep learning method named unsupervised disentangled dual-domain network (UDDN) was proposed to effectively disentangle and remove unwanted rigid motion artifacts from images. In UDDN, a dual-domain encoding module was presented to capture different types of information from the spatial and frequency domains to enrich the information. Moreover, a cross-domain attention fusion module was proposed to effectively fuse information from different domains, reduce information redundancy, and improve the performance of motion artifact removal. UDDN was validated on a publicly available dataset and a clinical dataset. Qualitative and quantitative experimental results showed that our method could effectively remove motion artifacts and reconstruct image details. Moreover, the performance of UDDN surpasses that of several state-of-the-art unsupervised methods and is comparable with that of the supervised method. Therefore, our method has great potential for clinical application in MRI, such as real-time removal of rigid motion artifacts.
Collapse
Affiliation(s)
- Boya Wu
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
| | - Caixia Li
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou 510515, China.
| | - Jiawei Zhang
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
| | - Haoran Lai
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China.
| | - Qianjin Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou 510515, China.
| | - Meiyan Huang
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510515, China; Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou 510515, China; Guangdong Province Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou 510515, China.
| |
Collapse
|
4
|
Chen Z, Pawar K, Ekanayake M, Pain C, Zhong S, Egan GF. Deep Learning for Image Enhancement and Correction in Magnetic Resonance Imaging-State-of-the-Art and Challenges. J Digit Imaging 2023; 36:204-230. [PMID: 36323914 PMCID: PMC9984670 DOI: 10.1007/s10278-022-00721-9] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 09/09/2022] [Accepted: 10/17/2022] [Indexed: 11/06/2022] Open
Abstract
Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast for clinical diagnoses and research which underpin many recent breakthroughs in medicine and biology. The post-processing of reconstructed MR images is often automated for incorporation into MRI scanners by the manufacturers and increasingly plays a critical role in the final image quality for clinical reporting and interpretation. For image enhancement and correction, the post-processing steps include noise reduction, image artefact correction, and image resolution improvements. With the recent success of deep learning in many research fields, there is great potential to apply deep learning for MR image enhancement, and recent publications have demonstrated promising results. Motivated by the rapidly growing literature in this area, in this review paper, we provide a comprehensive overview of deep learning-based methods for post-processing MR images to enhance image quality and correct image artefacts. We aim to provide researchers in MRI or other research fields, including computer vision and image processing, a literature survey of deep learning approaches for MR image enhancement. We discuss the current limitations of the application of artificial intelligence in MRI and highlight possible directions for future developments. In the era of deep learning, we highlight the importance of a critical appraisal of the explanatory information provided and the generalizability of deep learning algorithms in medical imaging.
Collapse
Affiliation(s)
- Zhaolin Chen
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia.
- Department of Data Science and AI, Monash University, Melbourne, VIC, Australia.
| | - Kamlesh Pawar
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
| | - Mevan Ekanayake
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC, Australia
| | - Cameron Pain
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, VIC, Australia
| | - Shenjun Zhong
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- National Imaging Facility, Brisbane, QLD, Australia
| | - Gary F Egan
- Monash Biomedical Imaging, Monash University, Melbourne, VIC, 3168, Australia
- Turner Institute for Brain and Mental Health, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
5
|
Plumley A, Watkins L, Treder M, Liebig P, Murphy K, Kopanoglu E. Rigid motion-resolved B1+ prediction using deep learning for real-time parallel-transmission pulse design. Magn Reson Med 2022; 87:2254-2270. [PMID: 34958134 PMCID: PMC7613077 DOI: 10.1002/mrm.29132] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 11/30/2021] [Accepted: 12/03/2021] [Indexed: 11/19/2022]
Abstract
PURPOSE Tailored parallel-transmit (pTx) pulses produce uniform excitation profiles at 7 T, but are sensitive to head motion. A potential solution is real-time pulse redesign. A deep learning framework is proposed to estimate pTx B 1 + distributions following within-slice motion, which can then be used for tailored pTx pulse redesign. METHODS Using simulated data, conditional generative adversarial networks were trained to predict B 1 + distributions in the head following a displacement. Predictions were made for two virtual body models that were not included in training. Predicted maps were compared with ground-truth (simulated, following motion) B1 maps. Tailored pTx pulses were designed using B1 maps at the original position (simulated, no motion) and evaluated using simulated B1 maps at displaced position (ground-truth maps) to quantify motion-related excitation error. A second pulse was designed using predicted maps (also evaluated on ground-truth maps) to investigate improvement offered by the proposed method. RESULTS Predicted B 1 + maps corresponded well with ground-truth maps. Error in predicted maps was lower than motion-related error in 99% and 67% of magnitude and phase evaluations, respectively. Worst-case flip-angle normalized RMS error due to motion (76% of target flip angle) was reduced by 59% when pulses were redesigned using predicted maps. CONCLUSION We propose a framework for predicting B 1 + maps online with deep neural networks. Predicted maps can then be used for real-time tailored pulse redesign, helping to overcome head motion-related error in pTx.
Collapse
Affiliation(s)
- Alix Plumley
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
| | - Luke Watkins
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
- School of Physics & Astronomy, Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff, United Kingdom
| | - Matthias Treder
- School of Computer Science and Informatics, Cardiff University, Cardiff, United Kingdom
| | | | - Kevin Murphy
- School of Physics & Astronomy, Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff, United Kingdom
| | - Emre Kopanoglu
- Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom
| |
Collapse
|
6
|
Lee J, Shin D, Oh SH, Kim H. Method to Minimize the Errors of AI: Quantifying and Exploiting Uncertainty of Deep Learning in Brain Tumor Segmentation. SENSORS 2022; 22:s22062406. [PMID: 35336577 PMCID: PMC8951581 DOI: 10.3390/s22062406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Revised: 03/16/2022] [Accepted: 03/17/2022] [Indexed: 11/16/2022]
Abstract
Despite the unprecedented success of deep learning in various fields, it has been recognized that clinical diagnosis requires extra caution when applying recent deep learning techniques because false prediction can result in severe consequences. In this study, we proposed a reliable deep learning framework that could minimize incorrect segmentation by quantifying and exploiting uncertainty measures. The proposed framework demonstrated the effectiveness of a public dataset: Multimodal Brain Tumor Segmentation Challenge 2018. By using this framework, segmentation performances, particularly for small lesions, were improved. Since the segmentation of small lesions is difficult but also clinically significant, this framework could be effectively applied to the medical imaging field.
Collapse
Affiliation(s)
- Joohyun Lee
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea; (J.L.); (D.S.)
| | - Dongmyung Shin
- Department of Electrical and Computer Engineering, Seoul National University, Seoul 08826, Korea; (J.L.); (D.S.)
| | - Se-Hong Oh
- Division of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin 17035, Korea
- Correspondence: (S.-H.O.); (H.K.)
| | - Haejin Kim
- College of Science & Technology, Hongik University, Sejong 30016, Korea
- Correspondence: (S.-H.O.); (H.K.)
| |
Collapse
|