1
|
Dell SJ, Hannan SJ, Venter JA, Teenan D, Hannan NC, Raju D, Berry CW, Kiss HJ, Schallhorn JM. Comparative Analysis of Clinical and Patient-Reported Outcomes of a New Enhanced Monofocal IOL and a Conventional Monofocal IOL. Clin Ophthalmol 2024; 18:1157-1169. [PMID: 38707771 PMCID: PMC11070167 DOI: 10.2147/opth.s456332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2024] [Accepted: 04/05/2024] [Indexed: 05/07/2024] Open
Abstract
Purpose To compare the outcomes of the Tecnis Eyhance ICB00 IOL, designed to enhance intermediate vision, to a conventional Tecnis Monofocal ZCB00 IOL. Methods This retrospective analysis compared two cohorts of patients undergoing lens replacement surgery with bilateral implantation of the Tecnis ICB00 or the Tecnis ZCB00 IOL (383 patients in each group). Monocular and binocular uncorrected distance (UDVA), intermediate (UIVA; 66cm), and near (UNVA; 40cm) visual acuities, refractive predictability, and patient-reported outcomes were compared. A sub-analysis of patients with the Eyhance IOL was performed to compare patients who achieved bilateral emmetropia to those with mini-monovision. One-month postoperative outcomes were analyzed. Results Both groups had comparable UDVA outcomes. On average, both monocular and binocular UIVAs were approximately one Snellen line better in patients implanted with Eyhance IOL (monocular UIVA: ICB00 0.23 ± 0.18 logMAR, ZCB00 0.33 ± 0.19 logMAR; binocular UIVA: ICB00 0.18 ± 0.18 logMAR, ZCB00 0.26 ± 0.20 logMAR, p < 0.01). Likewise, the mean UNVA was also one Snellen line better with the ICB00 model (monocular UNVA: ICB00 0.51 ± 0.20 logMAR, ZCB00 0.61 ± 0.18 logMAR; binocular UNVA: ICB00 0.42 ± 0.19 logMAR, ZCB00 0.51 ± 0.22 logMAR, p < 0.01). There was no difference between the two groups in overall satisfaction or visual phenomena. A subgroup of patients who achieved mini-monovision with Eyhance IOL had, on average, one Snellen line better UIVA and UNVA compared to patients with bilateral emmetropia. Conclusion Patients receiving the enhanced monofocal IOL had better intermediate and near vision compared to those receiving the conventional monofocal IOL, with similar levels of patient-reported photic phenomena in both groups.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | - Julie M Schallhorn
- University of California, San Francisco, Department of Ophthalmology, San Francisco, CA, USA
- F.I. Proctor Foundation, University of California, San Francisco, CA, USA
| |
Collapse
|
2
|
Lyu J, Bang SP, Yoon G. Refractive extended depth-of-focus lens design based on periodic power profile for presbyopia correction. Ophthalmic Physiol Opt 2024; 44:301-310. [PMID: 37984831 PMCID: PMC10925839 DOI: 10.1111/opo.13253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 10/26/2023] [Accepted: 11/01/2023] [Indexed: 11/22/2023]
Abstract
PURPOSE Limitations of existing diffractive multifocal designs for presbyopia correction include discrete foci and photic phenomena such as halos and glare. This study aimed to explore a methodology for developing refractive extended depth-of-focus (EDoF) lenses based on a periodic power profile. METHODS The proposed design technique employed an optical power profile that periodically alternated between far, intermediate and near distances across the pupil radius. To evaluate the lens designs, optical bench testing was conducted. The impact on visual performance was assessed using a spatial light modulator-based adaptive optics vision simulator in human subjects. Additionally, the effects of pupil size change and lens decentration on retinal image quality were examined. A comparative performance analysis was carried out against a typical diffractive trifocal design and a monofocal lens. RESULTS The proposed design method was found to be effective in uniformly distributing light energy across all object distances within the desired depth of focus (DoF). While trade-offs between overall image quality and DoF still exist, the EDoF lens design, when tested in human subjects, provided a continuous DoF spanning over 2.25 D. The results also revealed that the EDoF design had a slightly higher dependence on changes in pupil size and lens decentration than the diffractive trifocal design. CONCLUSION The proposed design method showed significant potential as an approach for developing refractive EDoF ophthalmic lenses. These lenses offer a continuous DoF but are slightly more susceptible to variations in pupil size and decentration compared with the diffractive trifocal design.
Collapse
Affiliation(s)
- Jiakai Lyu
- Institute of Optics, University of Rochester, Rochester, New York, USA
| | - Seung Pil Bang
- Department of Biomedical Engineering, University of Rochester, Rochester, New York, USA
| | - Geunyoung Yoon
- College of Optometry, University of Houston, Houston, Texas, USA
| |
Collapse
|
3
|
Tarricone R, Rognoni C, Ciarlo A, Giabbani I, Novello L, Balestrieri M, Costa G, Favuzza E, Mencucci R, Taroni L, Tognetto D, Giglio R. Systematic review for the development of a core outcome set for monofocal intraocular lenses for cataract surgery. Front Med (Lausanne) 2024; 11:1339793. [PMID: 38444419 PMCID: PMC10912568 DOI: 10.3389/fmed.2024.1339793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 02/05/2024] [Indexed: 03/07/2024] Open
Abstract
Introduction The aim of the study was to define a core outcome set (COS) to be measured following cataract surgery for the postoperative evaluation of monofocal intraocular lenses (IOLs). Compared to current COSs, the present work provides updates considering the advances in the technology due to the development of new generation monofocal IOLs, which are characterized by a safety profile comparable to standard monofocal IOLs but with an extended range of intermediate vision. Methods Healthcare professionals (ophthalmologist surgeons) and patients were involved in the selection of outcomes to be included in the COS, starting from a list of indicators retrieved from a systematic literature search. The search considered observational studies with both a retrospective or prospective design, case studies and classic randomized controlled trials (RCTs). A mixed methodology integrating a Delphi-driven and an expert panel approach was adopted to reach an agreement among clinicians, while patients were involved in the completion of a questionnaire. Results The final COS included 15 outcomes. Eleven outcomes, all clinical, were considered for inclusion after a joint discussion among ophthalmologists; seven outcomes were linked to visual acuity, while the remaining to contrast sensitivity, refractive errors, aberrations and adverse events. Measurement metrics, method of aggregation and measurement time point of these outcomes were specified. The most important aspects for the patients were (1) quality of life after cataract surgery, (2) the capacity to perform activities requiring good near vision (e.g., reading), (3) spectacle independence, and (4) safety of movements without fear of getting hurt or falling (intermediate vision). Discussion In a context with limited healthcare resources, it is important to optimize their use considering also the preferences of end-users, namely patients. The proposed COS, developed involving both ophthalmologists and patients, provides an instrument for the postoperative evaluation of different technologies in the context of monofocal IOLs, which can be used not only in clinical trials but also in clinical practice to increase the body of real-world evidence.
Collapse
Affiliation(s)
- Rosanna Tarricone
- Centre for Research on Health and Social Care Management (CERGAS), SDA Bocconi School of Management, Bocconi University, Milan, Italy
- Department of Social and Political Sciences, Bocconi University, Milan, Italy
| | - Carla Rognoni
- Centre for Research on Health and Social Care Management (CERGAS), SDA Bocconi School of Management, Bocconi University, Milan, Italy
| | - Anita Ciarlo
- Centre for Research on Health and Social Care Management (CERGAS), SDA Bocconi School of Management, Bocconi University, Milan, Italy
| | - Ilaria Giabbani
- Centre for Research on Health and Social Care Management (CERGAS), SDA Bocconi School of Management, Bocconi University, Milan, Italy
| | - Leonardo Novello
- Centre for Research on Health and Social Care Management (CERGAS), SDA Bocconi School of Management, Bocconi University, Milan, Italy
| | | | - Giacomo Costa
- Ospedale Morgagni-Pierantoni, AUSL della Romagna, Forlì, Italy
| | - Eleonora Favuzza
- Eye Clinic, Department of Neurosciences, Psychology, Drug Research and Child Health (NEUROFARBA), University of Florence, Florence, Italy
| | - Rita Mencucci
- Eye Clinic, Department of Neurosciences, Psychology, Drug Research and Child Health (NEUROFARBA), University of Florence, Florence, Italy
| | - Leonardo Taroni
- Ospedale Morgagni-Pierantoni, AUSL della Romagna, Forlì, Italy
| | - Daniele Tognetto
- University Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| | - Rosa Giglio
- University Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| |
Collapse
|
4
|
Hwang HS, Lee H, Park JH, Chae JB, Kim DY. Cataract surgery with new monofocal intraocular lens enhanced for intermediate vision and standard monofocal intraocular lens for retinal disorder. Int Ophthalmol 2024; 44:104. [PMID: 38378994 DOI: 10.1007/s10792-024-03047-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 01/18/2024] [Indexed: 02/22/2024]
Abstract
AIM To investigate the difference in the initial surgical results between a new monofocal intraocular lens (IOL) with enhanced intermediate vision and the standard monofocal IOL in patients with retinal disease. METHODS We retrospectively reviewed the medical records of patients with retinal disease who underwent cataract surgery due to accompanying cataracts. Types of retinal diseases were investigated and best-corrected distant visual acuity, distant uncorrected visual acuity (UCVA), intermediate UCVA, near UCVA, and spherical equivalent were recorded at each visit. The surgical results were investigated at 1 day, 1 week, and 1 month after surgery. RESULTS Seventeen eyes treated with a new monofocal IOL enhanced for intermediate vision (ICB00 group) and 18 eyes treated with the standard monofocal IOL (AAB00 group) were included in this study. There were no significant differences in the baseline characteristics, including the type of underlying retinal disease, between the groups. There were no significant differences between the groups in terms of distant, intermediate, or near UCVA at day 1 and week 1 after surgery. However, at 1 month after surgery, the ICB00 group showed a significantly better intermediate vision improvement than the AAB00 group (p = 0.001). CONCLUSION Even in patients with cataract accompanied by retinal disease, the use of the ICB00 IOL showed significant improvement in intermediate vision compared to the use of the AAB00 (standard monofocal) IOL. The ICB00 IOL might be a good option for patients with cataract and retinal disease in the era of increased intermediate vision needs in daily life.
Collapse
Affiliation(s)
- Hye Seong Hwang
- Department of Ophthalmology, Chungbuk National University Hospital, Cheongju, Korea
| | - Hwanho Lee
- Nineteenth Fighter Wing, Republic of Korea Air Force, Chungju, Korea
| | | | - Ju Byung Chae
- Top Retina Center, 122, Gangseo-ro, Heungdeok-gu, Cheongju, 28387, Korea
| | - Dong Yoon Kim
- Top Retina Center, 122, Gangseo-ro, Heungdeok-gu, Cheongju, 28387, Korea.
| |
Collapse
|
5
|
Kim DR, Yoon YC, Whang WJ, Hwang HS, Na KS. Ocular parameters associated with visual performance of enhanced monofocal intraocular lens. BMC Ophthalmol 2024; 24:74. [PMID: 38369454 PMCID: PMC10875848 DOI: 10.1186/s12886-024-03316-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Accepted: 01/18/2024] [Indexed: 02/20/2024] Open
Abstract
BACKGROUND An enhanced monofocal intraocular lenses (IOLs) (Tecnis Eyhance ICB00 and Tecnis Eyhance Toric DIU) has been developed to enhance intermediate vision while avoiding the disadvantages of multifocal IOLs. Although many studies have demonstrated the improvement of intermediate visual acuity with enhanced monofocal IOLs, it is not known specifically for which patients these IOLs should be recommended or avoided. In this study, we aim to find out which ocular parameters affect vision performance and photic phenomenon of ICB00 or DIU at different distances. METHODS Patients who underwent cataract surgery with ICB00 or DIU, performed by a single surgeon, were included. Before surgery, the patients' age, gender, axial length, anterior chamber depth, spherical aberration Z (4,0), vertical coma, horizontal coma, angle kappa (κ), angle alpha (α), and other ocular parameters were investigated. One month after surgery, uncorrected near visual acuity (UNVA at 40 cm), uncorrected intermediate visual acuity (UIVA at 66 cm), uncorrected distance logMAR visual acuity (UDVA), IOL decentration, and quality of vision (QoV) questionnaires were conducted. RESULTS A total of 43 patients (58 eyes) were included. The results of the univariate linear regression analyses showed a negative correlation between spherical aberration and logMAR UNVA and UIVA (p = 0.003, β=-0.51 and p = 0.018, β=-0.23, respectively) and a positive correlation between angle α and logMAR UIVA (p = 0.036, β = 0.19). Deeper anterior chamber depth (ACD) was associated with poorer total QoV (p = 0.018, β = 14.43), particularly in glare, halo, blur, and fluctuation perception. A higher degree of IOL decentration tended to decrease UNVA and UIVA (Pearson correlation coefficient, r = 0.336 and r = 0.221, respectively); however, no significant effect was observed on UDVA (Pearson correlation coefficient, r = 0.042). CONCLUSIONS In enhanced monofocal IOLs, a higher level of spherical aberration is associated with better performance in UNVA and UIVA, whereas a larger angle α has a negative impact. A deeper ACD negatively affects the QoV.
Collapse
Affiliation(s)
- Da Ran Kim
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Young Chae Yoon
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Woong-Joo Whang
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Ho Sik Hwang
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kyung-Sun Na
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
| |
Collapse
|
6
|
Steinmüller LN, Greve D, Rua Amaro D, Bertelmann E, von Sonnleithner C. Analysis of higher-order aberrations in relation to the clinical outcome of an enhanced monofocal IOL. Eur J Ophthalmol 2023; 33:2096-2105. [PMID: 36274639 PMCID: PMC10590024 DOI: 10.1177/11206721221134171] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 09/25/2022] [Indexed: 10/22/2023]
Abstract
PURPOSE To analyse higher-order aberrations of an enhanced monofocal aspheric intraocular lens (IOL) in relation to the clinical outcome compared to a monofocal aspheric IOL. SETTING Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Germany. DESIGN Prospective, monocentric, controlled, non-randomized, two-armed study. METHODS After phacoemulsification, a total of 30 patients (60 eyes) were bilaterally implanted with either TECNIS Eyhance IOL model ICB00 (Johnson & Johnson Surgical Vision, Inc.) or TECNIS Monofocal 1-Piece IOL model ZCB00 (Johnson & Johnson Surgical Vision, Inc.) in 30 eyes each. Assessments were performed 1 and 3 months after surgery including refraction, uncorrected and best-corrected distance, intermediate and near visual acuity, defocus curves, contrast sensitivities under photopic, mesopic and mesopic conditions with glare, higher-order aberrations (HOAs) at pupil sizes of 5, 4, 3 and 2 mm and patient satisfaction. RESULTS At 3-month follow-up, measurements of HOAs revealed significant higher negative internal and ocular primary spherical aberrations in the ICB00 group at pupil sizes of 5, 4, 3 and 2 mm. The ICB00 showed significant better results in intermediate and near visual acuity, but no difference in distance visual acuity. No significant difference was found in contrast sensitivities at any condition or spatial frequency. Spectacle independence was significant better without significant higher rates of dysphotopsia in the ICB00 group. CONCLUSIONS Higher negative spherical aberrations in the ICB00 group at all measured pupil sizes appear to lead to a superior clinical outcome in intermediate and near vision compared to the ZCB00 group without compromising contrast sensitivity or distance visual acuity.
Collapse
Affiliation(s)
| | - Daria Greve
- Department of Ophthalmology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - David Rua Amaro
- Department of Ophthalmology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | - Eckart Bertelmann
- Department of Ophthalmology, Charité – Universitätsmedizin Berlin, Berlin, Germany
| | | |
Collapse
|
7
|
Donoso R, Torres A, Klagges J, Mercado Y, Gonzalez T, Astudillo M, Norambuena H, Medina E. Enhanced vs conventional monofocal intraocular lens clinical results in patients with cataract: randomized clinical trial. J Cataract Refract Surg 2023; 49:818-825. [PMID: 37232418 DOI: 10.1097/j.jcrs.0000000000001224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Accepted: 05/17/2023] [Indexed: 05/27/2023]
Abstract
PURPOSE To compare clinical outcomes between an enhanced and a conventional monofocal intraocular lens (IOL) after cataract surgery. SETTING Ophthalmology Unit, Hospital del Salvador, University of Chile (tertiary care hospital). DESIGN Double-masked, prospective randomized controlled trial. METHODS 66 healthy adults with corneal astigmatism less than 1.50 diopters and axial length between 21 and 27 mm were randomly allocated (1:1) for bilateral phacoemulsification with either an enhanced monofocal IOL (ICB00) or a conventional aspheric monofocal IOL (ZCB00) implant. The refractive target was emmetropia in both eyes. Visual acuities, defocus curves, Catquest-9SF, and quality of vision (QoV) were measured 3 months postoperatively. RESULTS Binocular uncorrected intermediate visual acuity was improved in patients implanted with the enhanced monofocal lens (0.37 ± 0.12) compared with the conventional monofocal (0.45 ± 0.10) ( P < .01). There were no significant differences in corrected distance visual acuity (CDVA), Catquest-9SF, or QoV scores. CONCLUSIONS The enhanced monofocal IOL provided 1 additional line of intermediate visual acuity after cataract surgery. There was no significant change in either CDVA or QoV.
Collapse
Affiliation(s)
- Rodrigo Donoso
- From the Hospital del Salvador, Universidad de Chile, Santiago, Chile
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Goslings O, Veraart H, van de Laar-Muskens J, Piñero DP. Clinical outcomes with an aspheric monofocal and a new enhanced monofocal intraocular lens with modified optical profile. Graefes Arch Clin Exp Ophthalmol 2023; 261:2315-2326. [PMID: 37256375 PMCID: PMC10368552 DOI: 10.1007/s00417-023-06128-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 04/13/2023] [Accepted: 05/22/2023] [Indexed: 06/01/2023] Open
Abstract
PURPOSE This study aimed to evaluate and compare the clinical outcomes obtained after cataract surgery with an aspheric monofocal intraocular lens (IOL) and an enhanced IOL with a modified optical profile. METHODS Randomised clinical trial enrolling 70 patients (age, 52-87 years) undergoing cataract surgery. Two groups were created according to the type of IOL implanted: Vivinex iSert from Hoya Surgical Optics (Vivinex group, 35 patients) and Tecnis Eyhance ICB00 from Johnson & Johnson Vision (Eyhance group, 35 patients). Uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity (DCIVA), refraction, and self-perceived visual function (Catquest-9SF) were evaluated during a 3-month follow-up. RESULTS No significant differences were found between IOL groups in UDVA and CDVA (p ≥ 0.093). In contrast, monocular and binocular UIVA and DCIVA were significantly better in the Eyhance group at 1 (p ≤ 0.015) and 3 months postoperatively (p ≤ 0.002). Postoperative DCIVA 20/25 or better was obtained in 71.4% and 20.0% of patients in Eyhance and Vivinex groups, respectively. Differences in postoperative Rasch calibrated Catquest scores between Eyhance and Vivinex groups did not reach statistical significance (p ≥ 0.102). However, significant correlations were only found between the change in UIVA and Catquest scores (0.364 ≤ r ≤ 0.444, p ≤ 0.041) in the Eyhance group. CONCLUSIONS The modified monofocal IOL evaluated provides better intermediate visual function in comparison with a standard aspheric monofocal IOL, but the impact of this benefit on the self-perceived level of vision achieved after surgery according to the patient seemed to be limited.
Collapse
Affiliation(s)
- Oege Goslings
- Department of Ophthalmology, Elisabeth-TweeSteden Hospital, Hilvarenbeekseweg 60, 5022 GC Tilburg, The Netherlands
| | - Henk Veraart
- Department of Ophthalmology, Elisabeth-TweeSteden Hospital, Hilvarenbeekseweg 60, 5022 GC Tilburg, The Netherlands
| | - Janny van de Laar-Muskens
- Department of Ophthalmology, Elisabeth-TweeSteden Hospital, Hilvarenbeekseweg 60, 5022 GC Tilburg, The Netherlands
| | - David P. Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Crta San Vicente del Raspeig S/N 03016, San Vicente del Raspeig, Alicante, Spain
| |
Collapse
|
9
|
Fernández J, Burguera N, Rocha-de-Lossada C, Rodríguez-Calvo-de-Mora M, Rodríguez-Vallejo M. Agreement between Two Devices for Measuring Pupil Diameter in Patients Implanted with Multifocal Intraocular Lenses. Vision (Basel) 2023; 7:vision7020040. [PMID: 37218958 DOI: 10.3390/vision7020040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/12/2023] [Accepted: 05/03/2023] [Indexed: 05/24/2023] Open
Abstract
The purpose of this study was to evaluate the agreement between three methods for measuring pupil size in patients implanted with multifocal intraocular lenses (MIOLs): Keratograph 5M (K5M), Pentacam AXL Wave (PW), and a simple hand ruler. Sixty-nine subjects implanted with MIOLs and measured at the three-month follow-up visit were included in this retrospective analysis. K5M and PW were used to measure the photopic (PP) and mesopic (MP) pupil sizes, and a hand ruler was used to measure the pupil under environmental light conditions (135 lux). The Bland-Altman method with its limits (LoAs) was used to assess the agreement. The median PP was 2.8, 2.95, and 3 mm for K5M, PW, and the ruler, respectively (p < 0.05). Differences in PP were statistically significant for all paired comparisons (p < 0.0005) except between PW and the ruler (p = 0.44). The LoAs for the difference in PP between K5M and PW was 0.63 mm. The mean difference for MP between K5M and PW was 0.04 mm (p = 0.34) with LoAs of 0.72 mm. MP measured with K5M and PW could be considered interchangeable, although a correction of -0.3 mm (IC95%: -0.23 to -0.39) should be applied to PP measured with PW to attain the K5M mean.
Collapse
Affiliation(s)
- Joaquín Fernández
- Department of Ophthalmology (Qvision), VITHAS Almería Hospital, 04120 Almería, Spain
| | - Noemí Burguera
- Department of Ophthalmology (Qvision), VITHAS Almería Hospital, 04120 Almería, Spain
| | - Carlos Rocha-de-Lossada
- Department of Ophthalmology (Qvision), VITHAS Almería Hospital, 04120 Almería, Spain
- Department of Ophthalmology, VITHAS Málaga, 29016 Málaga, Spain
- Department of Ophthalmology, Hospital Regional Universitario de Málaga, Plaza del Hospital Civil, S/N, 29009 Málaga, Spain
- Departamento de Cirugía, Universidad de Sevilla, Área de Oftalmología, Doctor Fedriani, S/N, 41009 Sevilla, Spain
| | - Marina Rodríguez-Calvo-de-Mora
- Department of Ophthalmology (Qvision), VITHAS Almería Hospital, 04120 Almería, Spain
- Department of Ophthalmology, VITHAS Málaga, 29016 Málaga, Spain
- Department of Ophthalmology, Hospital Regional Universitario de Málaga, Plaza del Hospital Civil, S/N, 29009 Málaga, Spain
| | | |
Collapse
|
10
|
Choi WK, Han HJ, Son HS, Khoramnia R, Auffarth GU, Choi CY. Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population. BMC Ophthalmol 2023; 23:157. [PMID: 37069559 PMCID: PMC10108453 DOI: 10.1186/s12886-023-02897-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Accepted: 04/02/2023] [Indexed: 04/19/2023] Open
Abstract
BACKGROUND To compare the clinical outcomes of bilateral implantation of enhanced intermediate function intraocular lenses (IOLs) and standard monofocal IOLs. METHODS In this prospective, randomized, comparative controlled study, we compared the visual outcomes of patients who underwent bilateral cataract surgery at the Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, with either enhanced monofocal IOLs (Tecnis Eyhance, ICB00, Johnson and Johnson Vision Care, Inc) (Group 1) or standard monofocal IOLs (Tecnis, ZCB00, Johnson and Johnson Vision Care, Inc) (Group 2). The assessment included monocular and binocular uncorrected distance visual acuity (UDVA), uncorrected intermediate (UIVA at 60 cm) and near (UNVA at 40 cm) visual acuity, uncorrected defocus curves, contrast sensitivity testing (CST), and reading speed test using Quality of vision was evaluated using the Visual Function Questionnaire (VFQ-25). RESULTS At 3-months postoperatively, monocular and binocular outcomes of UIVA and UNVA were statistically significantly better in Group 1 (P < 0.05). The binocular uncorrected defocus curve of Group 1 showed statistically significantly better outcomes at vergence ranges of -1.5 to -4.0 D (P < 0.05). Significantly higher reading speed test was also observed in Group 1 in all ranges tested (1.0 to 0.1 LogMAR) (P < 0.05). There were no statistically significant differences in CST between groups. CONCLUSIONS Bilateral implantation of enhanced monofocal IOLs provided better vision at intermediate and near distances compared to standard monofocal IOLs, while maintaining good distance vision and contrast sensitivity.
Collapse
Affiliation(s)
- Wan Kyu Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-Ro, Jongno-Gu, Seoul, 03181, Republic of Korea
| | - Hyo Ji Han
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-Ro, Jongno-Gu, Seoul, 03181, Republic of Korea
| | - Hyeck-Soo Son
- Department of Ophthalmology, The David J. Apple International Laboratory for Ocular Pathology, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Ramin Khoramnia
- Department of Ophthalmology, The David J. Apple International Laboratory for Ocular Pathology, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Gerd U Auffarth
- Department of Ophthalmology, The David J. Apple International Laboratory for Ocular Pathology, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany
| | - Chul Young Choi
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, 29 Saemunan-Ro, Jongno-Gu, Seoul, 03181, Republic of Korea.
| |
Collapse
|
11
|
Gigon E, Bouthour W, Panos GD, Pajic B, Massa H. Real world outcomes of the new Tecnis Eyhance IOL. Eur J Ophthalmol 2022; 33:1390-1397. [PMID: 36567614 PMCID: PMC10152560 DOI: 10.1177/11206721221146675] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To compare the performance of Tecnis Eyhance ICB00 with Tecnis PCB00 IOL for far, intermediate, and near vision, in patients after bilateral cataract surgery. SETTINGS This study was done at Geneva University Hospitals. DESIGN This is a retrospective study of 224 eyes that underwent cataract between May 2019 and June 2020. METHODS Visual acuity was assessed from month 1 to 12 after surgery for distance, intermediate and near visual acuity, by the same optometrist, which was blind regarding the type of IOL. The patients answered to a quality of life questionnaire. Patients were excluded for: monocular surgery, macular disease, other IOL type, or inability to reach 20/20 visual acuity in both eyes without correction. RESULTS One hundred and fifty-two eyes were excluded. Three groups were then analyzed: PCB00 group (38 eyes), ICB00 group (22 eyes), and mismatch group (12 eyes). Monocular visual acuities (CIVA, UNVA and CNVA, in logMAR) were higher in the ICB00 group than the PCB00 group (respectively 0.3 vs 0.4, p = 0.0033; 0.3 vs 0.4, p = 0.0408; 0.3 vs 0.4, p = 0.0039). Binocular visual acuities, CIVA and CNVA were higher in the ICB00 group than the PCB00 group (0.2 vs 0.4, p = 0.0061; 0.15 vs 0.3, p = 0.018). This mirrored the findings of the quality of life questionnaire. There was no significant difference between PCB00 and mismatch groups. CONCLUSIONS the Tecnis Eyhance was more effective for intermediate and near vision. The central defocus of the lens might help patients achieve spectacle independence and better quality of life.
Collapse
Affiliation(s)
- Edward Gigon
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland
| | - Walid Bouthour
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland
| | - Georgios D Panos
- Department of Ophthalmology, Queen's Medical Centre, 9820Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Bojan Pajic
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland.,Eye Clinic Orasis, Swiss Eye Research Foundation, Reinach AG, Switzerland.,Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Faculty of Sciences, Department of Physics, University of Novi Sad, Novi Sad, Serbia.,Faculty of Medicine of the Military Medical Academy, University of Defense, Belgrade, Serbia
| | - Horace Massa
- Department of Clinical Neurosciences, Division of Ophthalmology, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
12
|
Abd Elghaffar Shehata M, Hosny MH, Tolba DA, Attya M. Evaluation of Postoperative Total Ocular Aberrations After Bilateral Implantation of Monofocal IOL with Extended Depth of Focus in Phacoemulsification. Clin Ophthalmol 2022; 16:4257-4261. [PMID: 36575683 PMCID: PMC9790161 DOI: 10.2147/opth.s391355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2022] [Accepted: 12/01/2022] [Indexed: 12/24/2022] Open
Abstract
Purpose To evaluate postoperative visual performance and total ocular aberration in cataract patients after implantation of the TECNIS Eyhance™ intraocular lens (IOL). Methods Our study is a prospective interventional non-comparative study that was conducted on 34 eyes of 17 patients who underwent phacoemulsification and Eyhance IOL implantation. Postoperative corrected and uncorrected near and far visual acuity and total ocular aberration were assessed 3 months after surgery. Results Our study included 34 eyes of 17 patients. At the third postoperative month, the mean spherical equivalent (SE) was -0.32 diopters (D) (SD ±0.62), and the mean distance-corrected near visual acuity (DCNVA) was 0.33 (SD ±0.15) and 0.42 (SD ±0.17) decimal notation (DN) monocular and binocular, respectively. The mean near distance with maximum visual acuity was 79.47 cm (SD ±7.70) and 74.76 cm (SD ±7.90) monocular and binocular, respectively. The mean postoperative minimum reading addition (add) was 1.6 D (SD ±0.47). The mean spherical aberration (SA) was 0.13 µm (SD ±0.09). The correlation of amount of spherical aberration with power of minimum reading add at 40 cm was not statistically significant (p=0.324). Conclusion The TECNIS Eyhance IOL provides good intermediate visual acuity and decreases the power of the reading add needed after phacoemulsification.
Collapse
Affiliation(s)
| | | | | | - Mohamed Attya
- Department of Ophthalmology, Cairo University, Cairo, Egypt,Correspondence: Mohamed Attya, Department of Ophthalmology, Cairo University, 15th Zahret Alsokar, Alsheikh Othman, Alhawamedia, Giza, Egypt, Tel +201113332892, Email
| |
Collapse
|
13
|
Current Advances and Future of Premium IOLs. CURRENT SURGERY REPORTS 2022. [DOI: 10.1007/s40137-022-00333-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
14
|
Redruello-Guerrero P, Rivera-Izquierdo M, Jiménez-Gutiérrez C, Láinez-Ramos-Bossini AJ, Yela R, López-Marín I. Improvement of intermediate vision with new monofocal intraocular lenses: A systematic review and meta-analysis. Eur J Ophthalmol 2022; 33:1308-1319. [PMID: 36124373 DOI: 10.1177/11206721221127075] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE Monofocal intraocular lenses (IOLs) used in cataract surgery are designed to improve visual acuity (VA). The available evidence of new monofocal IOLs" functional benefits is limited. The aim of this meta-analysis was to analyze the improvement in VA using Tecnis Eyhance monofocal IOLs compared to standard monofocal IOLs Tecnis ZCB00. METHODS MEDLINE, Web of Science and Scopus were searched for studies assessing improvement in intermediate VA using Tecnis Eyhance IOLs versus Tecnis ZCB00 IOLs. Studies evaluating post-operative VA in patients who underwent cataract surgery were selected. This meta-analysis followed PRISMA guidelines and was registered in PROSPERO. The Cochrane Risk of Bias Tool 2.0. was used to assess the methodological quality of the included studies, risk of selection bias and comparability of cohorts and outcomes. RESULTS The search resulted in 1153 articles. Five studies met the inclusion criteria and were included in the meta-analysis. A total of 604 eyes were evaluated, of which 309 received Tecnis Eyhance IOLs and 295 were implanted with Tecnis ZCB00 IOLs. Mean binocular distant-corrected intermediate VA with Tecnis Eyhance IOLs at 2 weeks-1 month showed a significant difference of -0,21 logMAR, p < 0.001; and mean binocular distance-corrected intermediate VA with Tecnis Eyhance IOLs at 6 months showed a significant difference of -0,11 logMAR, p < 0.001. CONCLUSION Near VA could not be assessed in this meta-analysis as it was measured in very few studies. Preliminary pooled evidence indicates that intermediate VA improved with Tecnis Eyhance IOLs. Further studies evaluating near VA and with longer follow-up are still necessary.
Collapse
Affiliation(s)
- Pablo Redruello-Guerrero
- Ophthalmology Department, Visióon Clinic Centre, Granada, Spain.,Department of Human Anatomy and Embryology, 16741University of Granada, Granada, Spain
| | - Mario Rivera-Izquierdo
- Department of Preventive Medicine and Public Health, 16741University of Granada, Granada, Spain.,Department of Preventive Medicine and Public Health, 16581San Cecilio University Hospital, Granada, Spain
| | | | | | - Rubén Yela
- Ophthalmology Department, Visióon Clinic Centre, Granada, Spain
| | | |
Collapse
|
15
|
Baur ID, Auffarth GU, Łabuz G, Khoramnia R. [Implantation of a Toric IOL with Enhanced Depth of Focus for Unilateral Traumatic Cataract]. Klin Monbl Augenheilkd 2022. [PMID: 35580622 DOI: 10.1055/a-1809-5187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Affiliation(s)
- Isabella Diana Baur
- Universitäts-Augenklinik Heidelberg, Universitätsklinikum Heidelberg, Deutschland
| | - Gerd U Auffarth
- Universitäts-Augenklinik Heidelberg, Universitätsklinikum Heidelberg, Deutschland
| | - Grzegorz Łabuz
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| | - Ramin Khoramnia
- International Vision Correction Research Centre (IVCRC) und David J Apple International Laboratory for Ocular Pathology, Universitäts-Augenklinik Heidelberg, Deutschland
| |
Collapse
|
16
|
Blancafort Alias S, Del Campo Carrasco Z, Salvador-Miras I, Luna Mariné S, Gómez Prieto MJ, Liñán Martín F, Salvà Casanovas A. Exploring Vision-Related Quality of Life: A Qualitative Study Comparing Patients’ Experience of Cataract Surgery with a Standard Monofocal IOL and an Enhanced Monofocal IOL. Clin Ophthalmol 2022; 16:1641-1652. [PMID: 35656389 PMCID: PMC9153939 DOI: 10.2147/opth.s358386] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 04/29/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- Sergi Blancafort Alias
- Fundació Salut i Envelliment (Health and Ageing Foundation), Universitat Autònoma de Barcelona (UAB), Barcelona, 08041, Spain
- Correspondence: Sergi Blancafort Alias, Fundació Salut i Envelliment (Health and Ageing Foundation), Universitat Autònoma de Barcelona (UAB), Sant Antoni Maria Claret, 171, Barcelona, 08041, Spain, Tel +34 93 433 50 30, Email
| | | | | | | | | | | | - Antoni Salvà Casanovas
- Fundació Salut i Envelliment (Health and Ageing Foundation), Universitat Autònoma de Barcelona (UAB), Barcelona, 08041, Spain
| |
Collapse
|
17
|
Moser Wurth C, Lecumberri Lopez M. Visual performance of a new Extended Depth of Focus (EDOF) intraocular lens: Preliminary results. J Fr Ophtalmol 2022; 45:529-536. [DOI: 10.1016/j.jfo.2021.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 10/13/2021] [Indexed: 10/19/2022]
|
18
|
Jeon YJ, Yoon Y, Kim TI, Koh K. Comparison Between an Intraocular Lens With Extended Depth of Focus (Tecnis Symfony ZXR00) and a New Monofocal Intraocular Lens With Enhanced Intermediate Vision (Tecnis Eyhance ICB00). Asia Pac J Ophthalmol (Phila) 2021; 10:542-547. [PMID: 34608065 PMCID: PMC8673848 DOI: 10.1097/apo.0000000000000439] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 08/24/2021] [Indexed: 11/26/2022] Open
Abstract
PURPOSE This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis Symfony, Johnson & Johnson Vision, Santa Ana, CA, US) to a novel, higher-order aspheric monofocal IOL (ICB00; Tecnis Eyhance, Johnson & Johnson Vision, Santa Ana, CA, US) which uses the same platform and material. METHODS Medical records of patients undergoing cataract surgery with ZXR00 or ICB00 implantation between March 2020 and January 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA); corrected distance VA; and optical quality parameters were the main outcome measures. RESULTS Among the 174 enrolled patients, 72 and 102 received the ZXR00 and ICB00, respectively. The average patient ages were 59.6 ± 10.6 (range: 49 to 70) and 65.2 ± 8.2 (range: 45 to 82) years in the ZXR00 and ICB00 groups, respectively, with significantly older patients in the ICB00 group. The other baseline parameters were not different for the 2 groups. Compared to the ICB00 group, the ZXR00 group showed markedly superior near VA (P < 0.05) at 3 months postoperatively. In terms of optical quality, ICB00 was, statistically, significantly superior to ZXR00. CONCLUSIONS The ZXR00 showed remarkable near vision and defocus curve smoothness, while the ICB00 achieved better optical quality. The 2 IOLs had comparable distance and intermediate vision.
Collapse
Affiliation(s)
- Young Joon Jeon
- Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| | - Yisang Yoon
- Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| | - Tae-im Kim
- Department of Opthalmology, Severance Eye Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kyungmin Koh
- Department of Opthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
19
|
Kang KH, Song MY, Kim KY, Hwang KY, Kwon YA, Koh K. Visual Performance and Optical Quality after Implantation of a New Generation Monofocal Intraocular Lens. KOREAN JOURNAL OF OPHTHALMOLOGY 2021; 35:112-119. [PMID: 33845556 PMCID: PMC8046615 DOI: 10.3341/kjo.2020.1115] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 02/21/2021] [Indexed: 11/26/2022] Open
Abstract
Purpose To evaluate the performance of two intraocular lenses (IOLs). The new monofocal IOL using a higher-order aspheric optic (Tecnis Eyhance ICB00) was compared to a standard monofocal IOL (Tecnis monofocal ZCB00) of the identical platform and material. Methods The medical records of the patients who had undergone cataract surgery with implantation of either the ZCB00 or the ICB00 in the dominant eye from March 2020 to August 2020 and with available data from the 3-month visit were reviewed. Subjects with ocular comorbidities or corneal astigmatism greater than 1.00 diopters were excluded. The uncorrected near, intermediate, distance visual acuity and corrected distance visual acuity were the main outcome measures. Optical quality parameters measured using an optical quality analysis system, clinical records including age, sex, laterality, ocular dominance, and information related to refractory errors was also collected. Parameters related to the refractory errors were all uniformly based on the Barrett Universal II formula. Results Of the 197 recruited patients, 111 and 86 were implanted with the ICB00 and ZCB00, respectively. No statistically significant differences in baseline parameters were observed between the two groups. While no statistically significant differences in distance visual acuity or optical quality were found between the two groups, compared to the ZCB00 group, the ICB00 group showed significantly higher intermediate visual acuity (p < 0.001) and near visual acuity (p < 0.05) 3 months postoperatively. Conclusions ICB00 provided superior intermediate vision and comparable distance performance and photic phenomena compared to a standard monofocal IOL.
Collapse
Affiliation(s)
- Kyoung Hae Kang
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Mi Yeon Song
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Kook Young Kim
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Kyu-Yeon Hwang
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Young-A Kwon
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| | - Kyungmin Koh
- Department of Ophthalmology, Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea
| |
Collapse
|