Liu Q, Yang W, Li D, Wang Z, Chen W, Zhai C, Wei W. Total and simulated keratometry measurements using IOLMaster 700 and Pentacam AXL after small incision lenticule extraction. Int Ophthalmol 2024; 44:237. [PMID: 38902457 DOI: 10.1007/s10792-024-03191-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Accepted: 06/15/2024] [Indexed: 06/22/2024]
Abstract
PURPOSE Calculating the intraocular lens (IOL) in patients after corneal refractive surgery presents a challenge. Because an overestimation of corneal power in cases undergone this surgery leading to a subsequent under-correction of IOL power. However, recent advancements in technology have eliable measurement of total corneal power. The aim of this research was to assess the agreement in simulated keratometry (SimK) and total keratometry (TK) values between IOLMaster 700 and Pentacam AXL. METHODS The study involved 99 patients (99 eyes) undergone small incision lenticule extraction (SMILE) surgery. Each patient underwent scans using IOL Master 700 and Pentacam AXL. The following parameters were recorded: SimK1, SimK2, Total K1 (TK1), and Total K2 (TK2) for IOLMaster 700; and SimK1, SimK2, True Net Power (TNP) K1, TNPK2, Total Corneal Refractive Power (TCRP) K1, and TCRP K2 for Pentacam AXL. Agreement between the two devices was evaluated using Bland-Altman plot, while paired t-test was utilized to compare any differences in the same parameter by both instruments. RESULTS The results revealed a strong correlation between the two devices.Noticeable comparability was identified for all SimK variables. However, there were noticeable differences in TK measurements as well as TK1-TNPK1, TK2-TNP K2, TK1-TCRP K1, and TK2-TCRP K2 parameters when comparing the two devices. The IOLMaster 700 consistently measured steeper values than the Pentacam AXL, with significant and clinically relevant differences of 1.34, 1.37, 0.87, and 0.95 diopters, respectively. CONCLUSION While there was a noticeable correlation between the IOLMaster 700 and Pentacam AXL in SimK measurements, a marked difference was noted in TK values. The two devices cannot be used interchangeably when quantifying TK values.
Collapse
Affiliation(s)
- Qian Liu
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China
| | - Wenli Yang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China.
| | - Dongjun Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China
| | - Ziyang Wang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China
| | - Wei Chen
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China
| | - Changbin Zhai
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China
| | - Wenbin Wei
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, No.1 Dongjiaomin Ln, Dongcheng District, Beijing, 100730, China
| |
Collapse
|
2
|
Pan X, Wang Y, Li Z, Ye Z. Intraocular Lens Power Calculation in Eyes After Myopic Laser Refractive Surgery and Radial Keratotomy: Bayesian Network Meta-analysis. Am J Ophthalmol 2024; 262:48-61. [PMID: 37865389 DOI: 10.1016/j.ajo.2023.09.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2023] [Revised: 08/17/2023] [Accepted: 09/27/2023] [Indexed: 10/23/2023]
Abstract
PURPOSE To compare the accuracy of formulas for calculating intraocular lens power in eyes after myopic laser refractive surgery or radial keratotomy. DESIGN Bayesian network meta-analysis. METHODS PubMed, Embase, the Cochrane Data Base of Systematic Reviews, and the Cochrane Central Register of Controlled Trials databases were searched for retrospective and prospective clinical studies published from January 1, 2012, to August 24, 2022. The outcome measurement was the percentage of eyes with a predicted error within the target refractive range (±0.50 diopter [D] or ±1.00 D). RESULTS Our meta-analysis includes 24 studies of 1172 eyes after myopic refractive surgery that use 12 formulas for intraocular lens power calculation. (1) A network meta-analysis showed that Barrett true-K no history, the optical coherence tomography (OCT) formula, and the Masket formula had a significantly higher percent of eyes within ±0.50 D of the goal than the Haigis-L formula, whereas the Wang-Koch-Maloney formula showed the poor predictability. Using an error criterion of within ±1.00 D, the same 3 formulas performed slightly better than the Haigis-L formula. Based on performance using both prediction error criteria, the Barrett true-K no history formula, OCT formula, and Masket formula showed the highest probability of ranking as the top 3 among the 12 methods. (2) A direct meta-analysis with a subset of 4 studies and 5 formulas indicated that formulas did not differ in percent success for either the ±0.5 D or ±1.0 D error range in eyes that had undergone radial keratotomy. CONCLUSIONS The OCT, Masket, and Barrett true-K no history formulas are more accurate for eyes with previous myopic laser refractive surgery, whereas no significant difference was found among the formulas for eyes that had undergone radial keratotomy.
Collapse
Affiliation(s)
- Xiaoying Pan
- From the School of Medicine, Nankai University, Tianjin (X.P.); Department of Ophthalmology, the Chinese People's Liberation Army General Hospital, Beijing (X.P., Y.W., Z.L., Z.Y.), China
| | - Yuyao Wang
- Department of Ophthalmology, Medical School of Chinese People's Liberation Army, Beijing (Y.W.); Department of Ophthalmology, the Chinese People's Liberation Army General Hospital, Beijing (X.P., Y.W., Z.L., Z.Y.), China
| | - Zhaohui Li
- Department of Ophthalmology, the Chinese People's Liberation Army General Hospital, Beijing (X.P., Y.W., Z.L., Z.Y.), China
| | - Zi Ye
- Department of Ophthalmology, the Chinese People's Liberation Army General Hospital, Beijing (X.P., Y.W., Z.L., Z.Y.), China.
| |
Collapse
|
3
|
Zollet P, Romeo MA, Tripepi D, Vinciguerra P, Vinciguerra R. Camellin-Calossi Formula for Intraocular Lens Power Calculation in Patients With Previous Myopic Laser Vision Correction. J Refract Surg 2024; 40:e156-e163. [PMID: 38466761 DOI: 10.3928/1081597x-20240208-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
PURPOSE To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction. METHODS This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted. RESULTS Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D. CONCLUSIONS The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction. [J Refract Surg. 2024;40(3):e156-e163.].
Collapse
|
4
|
Savage DE, Pantanelli SM. An update on intraocular lens power calculations in eyes with previous laser refractive surgery. Curr Opin Ophthalmol 2024; 35:34-43. [PMID: 37820078 DOI: 10.1097/icu.0000000000001004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
PURPOSE OF REVIEW There is an ever-growing body of research regarding intraocular lens (IOL) power calculations following photorefractive keratectomy (PRK), laser-assisted in-situ keratomileusis (LASIK), and small-incision lenticule extraction (SMILE). This review intends to summarize recent data and offer updated recommendations. RECENT FINDINGS Postmyopic LASIK/PRK eyes have the best refractive outcomes when multiple methods are averaged, or when Barrett True-K is used. Posthyperopic LASIK/PRK eyes also seem to do best when Barrett True-K is used, but with more variable results. With both aforementioned methods, using measured total corneal power incrementally improves results. For post-SMILE eyes, the first nontheoretical data favors raytracing. SUMMARY Refractive outcomes after cataract surgery in eyes with prior laser refractive surgery are less accurate and more variable compared to virgin eyes. Surgeons may simplify their approach to IOL power calculations in postmyopic and posthyperopic LASIK/PRK by using Barrett True-K, and employing measured total corneal power when available. For post-SMILE eyes, ray tracing seems to work well, but lack of accessibility may hamper its adoption.
Collapse
Affiliation(s)
- Daniel E Savage
- Department of Ophthalmology, David and Ilene Flaum Eye Institute
- Center for Visual Science, University of Rochester, Rochester, New York
| | - Seth M Pantanelli
- Department of Ophthalmology, Penn State College of Medicine, Hershey, Pennsylvania, USA
| |
Collapse
|
5
|
Cione F, De Bernardo M, Gioia M, Oliviero M, Santoro AG, Caputo A, Capasso L, Pagliarulo S, Rosa N. A No-History Multi-Formula Approach to Improve the IOL Power Calculation after Laser Refractive Surgery: Preliminary Results. J Clin Med 2023; 12:jcm12082890. [PMID: 37109228 PMCID: PMC10144756 DOI: 10.3390/jcm12082890] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 04/06/2023] [Accepted: 04/13/2023] [Indexed: 04/29/2023] Open
Abstract
This retrospective comparative study proposes a multi-formula approach by comparing no-history IOL power calculation methods after myopic laser-refractive-surgery (LRS). One-hundred-thirty-two eyes of 132 patients who had myopic-LRS and cataract surgery were examined. ALMA, Barrett True-K (TK), Ferrara, Jin, Kim, Latkany and Shammas methods were evaluated in order to back-calculate refractive prediction error (PE). To eliminate any systematic error, constant optimization through zeroing-out the mean error (ME) was performed for each formula. Median absolute error (MedAE) and percentage of eyes within ±0.50 and ±1.00 diopters (D) of PE were analyzed. PEs were plotted with corresponding mean keratometry (K), axial length (AL), and AL/K ratio; then, different ranges were evaluated. With optimized constants through zeroing-out ME (90 eyes), ALMA was better when K ≤ 38.00 D-AL > 28.00 mm and when 38.00 D < K ≤ 40.00 D-26.50 mm < AL ≤ 29.50 mm; Barrett-TK was better when K ≤ 38.00 D-AL ≤ 26.50 mm and when K > 40.00 D-AL ≤ 28.00 mm or AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges. (p < 0.05) Without modified constants (132 eyes), ALMA was better when K > 38.00 D-AL ≤ 29.50 mm and when 36.00 < K ≤ 38.00 D-AL ≤ 26.50 mm; Barrett-TK was better when K ≤ 36.00 D and when K ≤ 38.00 D with AL > 29.50 mm; and both ALMA and Barrett-TK were better in other ranges (p < 0.05). A multi-formula approach, according to different ranges of K and AL, could improve refractive outcomes in post-myopic-LRS eyes.
Collapse
Affiliation(s)
- Ferdinando Cione
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Maddalena De Bernardo
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Marco Gioia
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Marianunzia Oliviero
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Andrea Giuseppe Santoro
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Alessandro Caputo
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Luigi Capasso
- Corneal Transplant Unit, ASL Napoli 1, 80100 Naples, Italy
| | - Sergio Pagliarulo
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| | - Nicola Rosa
- Eye Unit, Department of Medicine Surgery and Dentistry, Scuola Medica Salernitana, University of Salerno, 84081 Baronissi, Italy
| |
Collapse
|
6
|
Gatinel D, Debellemanière G, Saad A, Rampat R. Theoretical Relationship Among Effective Lens Position, Predicted Refraction, and Corneal and Intraocular Lens Power in a Pseudophakic Eye Model. Transl Vis Sci Technol 2022; 11:5. [PMID: 36069859 PMCID: PMC9465937 DOI: 10.1167/tvst.11.9.5] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To ascertain the theoretical impact of anatomical variations in the effective lens position (ELP) of the intraocular lens (IOL) in a thick lens eye model. The impact of optimization of IOL power formulas based on a single lens constant was also simulated. Methods A schematic eye model was designed and manipulated to reflect changes in the ELP while keeping the optical design of the IOL unchanged. Corresponding relationships among variations in ELP, postoperative spherical equivalent refraction, and required IOL power adjustment to attain target refractions were computed for differing corneal powers (38 diopters [D], 43 D, and 48 D) with IOL power ranging from 1 to 35 D. Results The change in ELP required to compensate for various systematic biases increased dramatically with low-power IOLs (less than 10 D) and was proportional to the magnitude of the change in refraction. The theoretical impact of the variation in ELP on postoperative refraction was nonlinear and highly dependent on the optical power of the IOL. The concomitant variations in IOL power and refraction at the spectacle plane, induced by varying the ELP, were linearly related. The influence of the corneal power was minimal. Conclusions The consequences of variations in the lens constant mainly concern eyes receiving high-power IOLs. The compensation of a systematic bias by a constant increment of the ELP may induce a nonsystematic modification of the predicted IOL power, according to the biometric characteristics of the eyes studied. Translational Relevance Optimizing IOL power formulas by altering the ELP may induce nonsystematic modification of the predicted IOL power.
Collapse
Affiliation(s)
- Damien Gatinel
- Anterior Segment and Refractive Surgery Department, Rothschild Foundation Hospital, Paris, France
| | - Guillaume Debellemanière
- Anterior Segment and Refractive Surgery Department, Rothschild Foundation Hospital, Paris, France
| | - Alain Saad
- Anterior Segment and Refractive Surgery Department, Rothschild Foundation Hospital, Paris, France
| | - Radhika Rampat
- Anterior Segment and Refractive Surgery Department, Rothschild Foundation Hospital, Paris, France
| |
Collapse
|
7
|
IOL Power Calculations and Cataract Surgery in Eyes with Previous Small Incision Lenticule Extraction. J Clin Med 2022; 11:jcm11154418. [PMID: 35956035 PMCID: PMC9369542 DOI: 10.3390/jcm11154418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2022] [Revised: 06/30/2022] [Accepted: 07/27/2022] [Indexed: 02/01/2023] Open
Abstract
Small incision lenticule extraction (SMILE), with over 5 million procedures globally performed, will challenge ophthalmologists in the foreseeable future with accurate intraocular lens power calculations in an ageing population. After more than one decade since the introduction of SMILE, only one case report of cataract surgery with IOL implantation after SMILE is present in the peer-reviewed literature. Hence, the scope of the present multicenter study was to compare the IOL power calculation accuracy in post-SMILE eyes between ray tracing and a range of empirically optimized formulae available in the ASCRS post-keratorefractive surgery IOL power online calculator. In our study of 11 post-SMILE eyes undergoing cataract surgery, ray tracing showed the smallest mean absolute error (0.40 D) and yielded the largest percentage of eyes within ±0.50/±1.00 D (82/91%). The next best conventional formula was the Potvin–Hill formula with a mean absolute error of 0.66 D and an ±0.50/±1.00 D accuracy of 45 and 73%, respectively. Analyzing this first cohort of post-SMILE eyes undergoing cataract surgery and IOL implantation, ray tracing showed superior predictability in IOL power calculation over empirically optimized IOL power calculation formulae that were originally intended for use after Excimer-based keratorefractive procedures.
Collapse
|
8
|
Zeng Z, Ye X, Chen Q, Jia C, Zhang G. Intraocular lens power calculation after two different successive corneal refractive surgeries. Am J Ophthalmol Case Rep 2022; 26:101547. [PMID: 35514797 PMCID: PMC9062137 DOI: 10.1016/j.ajoc.2022.101547] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 02/06/2022] [Accepted: 04/18/2022] [Indexed: 11/25/2022] Open
Abstract
Purpose To report two challenging intraocular lens power calculation cases with patients each underwent different successive corneal refractive surgeries, respectively. Observations Biometry data, including the Back to Front corneal radii ratio (B/F ratio), were collected by Lenstar, IOL Master, and Pentacam AXL for Case 1 (received radial keratotomy (RK) and photorefractive keratectomy (PRK)) and Case 2 (received RK and laser-assisted in situ keratomileusis (LASIK)). The IOL power calculation was determined by several methods, including Shammas, Haigis-L, and Barrett True-K, which are available in the American Society of Cataract and Refractive Surgery online calculator and Pentacam AXL. The Barrett True-K (no history, post-RK) was more accurate in Case 1 (increased B/F ratio), whereas the Shammas, Haigis-L, and Barrett True-K (no history, post-LASIK/PRK) were more accurate in Case 2 (decreased B/F ratio). Conclusion and importance The B/F ratio may be a factor to be considered when selecting the IOL power calculation formula for patients who undergo two different corneal refractive surgeries. The further study focusing on this issue should be performed to clarify the results in the future.
Collapse
|
9
|
Fang X, Ben S, Dong Y, Chen X, Xue W, Wang Y. Outcomes of the Haigis-L formula for calculating intraocular lens power in extreme long axis eyes after myopic laser in situ keratomileusis. Eye (Lond) 2022; 36:1178-1184. [PMID: 34117389 PMCID: PMC9151766 DOI: 10.1038/s41433-021-01551-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 03/07/2021] [Accepted: 04/13/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To evaluate the accuracy of refractive prediction by the Haigis-L formula compared to four other IOL power calculation formulas in eyes with extremely long axial lengths (AL > 29.0 mm) after LASIK. SETTING Shanghai Eye Disease and Prevention Treatment Center, Shanghai, China. DESIGN Retrospective case series. METHODS Twenty-nine eyes from 19 patients were available for analysis. The primary outcome measure was the arithmetic refractive prediction error (RPE), defined as the difference between the actual postoperative refractive error and the intended formula-derived refractive target. The main outcome measure was the median absolute refraction prediction error (MedAE). The accuracy of the Haigis-L was compared with Barrett True K No History, Shammas-PL, SRK/Tcorrected K, and Holladay 2corrected K methods to calculate IOL power. RESULTS The Haigis-L formula had a significantly larger MedAE than Shammas-PL and SRK/Tcorrected K formulas (P = 0.005 and P = 0.015, respectively), a smaller percentage of eyes within ±1.50 diopter (D) of predicted error in refraction compared with Shammas-PL and SRK/Tcorrected K formulas (P = 0.014 and P = 0.005, respectively). The refractive prediction errors of 6 eyes with corneal keratometry of less than 35 D by Haigis-L all had more than 1.95 D of myopic overestimation, while none of the other four methods resulted in an absolute error over 1.95 D. CONCLUSIONS The Haigis-L formula was relatively accurate in predicting extreme long axis (>29.0 mm) eyes after myopic LASIK surgery but less accurate for eyes with extremely flat corneas (<35 D). SRK/Tcorrected K and Shammas-PL performed better than the other methods for refractive prediction in this type of eyes. SYNOPSIS Haigis-L performed worse than SRK/Tcorrected K and Shammas-PL in predicting IOL power in extremely long axis (>29.0 mm) eyes after myopic LASIK, especially with extremely flat corneas (K < 35 D).
Collapse
Affiliation(s)
- Xiaoling Fang
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/Shanghai Eye Hospital, Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai General Hospital, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Shenyu Ben
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/Shanghai Eye Hospital, Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai General Hospital, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Yiping Dong
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/Shanghai Eye Hospital, Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai General Hospital, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Xia Chen
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/Shanghai Eye Hospital, Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai General Hospital, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Wenwen Xue
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/Shanghai Eye Hospital, Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai General Hospital, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China
| | - Yulan Wang
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/Shanghai Eye Hospital, Shanghai Key Laboratory of Ocular Fundus Diseases, Shanghai General Hospital, Shanghai Engineering Center for Visual Science and Photomedicine, Shanghai, China.
| |
Collapse
|
10
|
Development of a New Method for Calculating Intraocular Lens Power after Myopic Laser In Situ Keratomileusis by Combining the Anterior-Posterior Ratio of the Corneal Radius of the Curvature with the Double-K Method. J Clin Med 2022; 11:jcm11030522. [PMID: 35159971 PMCID: PMC8837081 DOI: 10.3390/jcm11030522] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/12/2021] [Accepted: 01/17/2022] [Indexed: 02/05/2023] Open
Abstract
Background: A new method, the Iida–Shimizu–Shoji (ISS) method, is proposed for calculating intraocular lens (IOL) power that combines the anterior–posterior ratio of the corneal radius of the curvature after laser in situ keratomileusis (LASIK) and to compare the predictability of the method with that of other IOL formulas after LASIK. Methods: The estimated corneal power before LASIK (Kpre) in the double-K method was 43.86 D according to the American Society of Cataract and Refractive Surgery calculator, and the K readings of the IOL master were used as the K values after LASIK (Kpost). The factor for correcting the target refractive value (correcting factor [C-factor]) was calculated from the correlation between the anterior–posterior ratio of the corneal radius of the curvature and the refractive error obtained using this method for 30 eyes of 30 patients. Results: Fifty-nine eyes of 59 patients were included. The mean values of the numerical and absolute prediction errors obtained using the ISS method were −0.02 ± 0.45 diopter (D) and 0.35 ± 0.27 D, respectively. The prediction errors using the ISS method were within ±0.25, ±0.50, and ±1.00 D in 49.2%, 76.3%, and 96.6% of the eyes, respectively. The predictability of the ISS method was comparable to or better than some of the other formulas. Conclusions: The ISS method is useful for calculating the IOL power in eyes treated with cataract surgery after LASIK.
Collapse
|
11
|
IOL Power Calculations after LASIK or PRK. J Cataract Refract Surg 2022; 48:784-789. [DOI: 10.1097/j.jcrs.0000000000000883] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 01/04/2022] [Indexed: 11/26/2022]
|
12
|
Wang L, Koch D. Intraocular lens power calculations in eyes with previous corneal refractive surgery: Challenges, approaches, and outcomes. Taiwan J Ophthalmol 2022; 12:22-31. [PMID: 35399961 PMCID: PMC8988985 DOI: 10.4103/tjo.tjo_38_21] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 09/10/2021] [Indexed: 11/04/2022] Open
Abstract
In eyes with previous corneal refractive surgery, difficulties in accurately determining corneal refractive power and in predicting the effective lens position create challenges in intraocular lens (IOL) power calculations. There are three categories of methods proposed based on the use of historical data acquired prior to the corneal refractive surgery. The American Society of Cataract and Refractive Surgery postrefractive IOL calculator incorporates many commonly used methods. Accuracy of refractive prediction errors within ± 0.5 D is achieved in 0% to 85% of eyes with previous myopic LASIK/photorefractive keratectomy (PRK), 38.1% to 71.9% of eyes with prior hyperopic LASIK/PRK, and 29% to 87.5% of eyes with previous radial keratotomy. IOLs with negative spherical aberration (SA) may reduce the positive corneal SA induced by myopic correction, and IOLs with zero SA best match corneal SA in eyes with prior hyperopic correction. Toric, extended-depth-of-focus, and multifocal IOLs may provide excellent outcomes in selected cases that meet certain corneal topographic criteria. Further advances are needed to improve the accuracy of IOL power calculation in eyes with previous corneal refractive surgery.
Collapse
|
13
|
Prediction accuracy of No History IOL formulas for a diffractive extended depth-of-focus IOL after myopic corneal refractive surgery. J Cataract Refract Surg 2021; 48:462-468. [PMID: 34978784 DOI: 10.1097/j.jcrs.0000000000000873] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Accepted: 12/01/2021] [Indexed: 11/26/2022]
Abstract
Purpose To compare the accuracy of intraocular lens (IOL) calculation methods for extended depth-of-focus (EDOF) IOLs in eyes with a history of myopic LASIK/PRK surgery lacking historical data. Setting Changsha Aier Eye Hospital, Changsha, and Wuhan Aier Eye Hospital, Wuhan, China. Design Retrospective case series. Methods Patients with ALs >= 25.0 mm and a history of myopic LASIK/PRK surgery who underwent cataract surgery with implantation of EDOF IOLs were enrolled. A comparison was performed of the accuracy of 10 IOL methods lacking historical data, including Barrett True-K No History (Barrett TKNH), Haigis-L, Shammas, Potvin-Hill, "Average", 'minimum" and "maximum" IOL power on the ASCRS online post-refractive IOL calculator; Triple-S formula; and SToP formulas based on Holladay1 and SRK/T. IOL power was calculated with the abovementioned methods in 2 groups according to AL (Group1: 25.0 mm <= AL < 28.0 mm and Group2: AL >= 28.0 mm). Results Sixty-four eyes were included. Excellent outcomes were achieved with the "Minimum", Barrett TKNH, SToP (SRK/T) and Triple-S in the whole sample and subgroups, which led to similar median absolute error, mean absolute error, and the percentage of eyes with a prediction error within +/- 0.5 D. In the whole sample, the Haigis-L and "Maximum" had a significantly higher absolute error than "Minimum", SToP (SRK/T) and Barrett TKNH. The "Maximum" also had a significantly lower percentage of eyes within +/- 0.5 D than the Barrett TKNH, and SToP (SRK/T) (15.6% vs 50% and 51.5%, all P<0.05 with Bonferroni correction). Conclusions No-history IOL formulas in predicting the EDOF IOL power in post-myopic refractive eyes remain challenging. The Barrett TKNH, Triple-S, "Minimum" and SToP (SRK/T) achieved the best accuracy when AL >= 25.0 mm, while the Barrett TKNH and SToP (SRK/T) were recommended when AL >= 28.0mm.
Collapse
|
14
|
Wang L, Koch DD. Intraocular Lens Power Calculations in Eyes with Previous Corneal Refractive Surgery. Ophthalmology 2021; 128:e121-e131. [DOI: 10.1016/j.ophtha.2020.06.054] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 06/10/2020] [Accepted: 06/24/2020] [Indexed: 12/12/2022] Open
|
15
|
Wei L, Meng J, Qi J, Lu Y, Zhu X. Comparisons of intraocular lens power calculation methods for eyes with previous myopic laser refractive surgery: Bayesian network meta-analysis. J Cataract Refract Surg 2021; 47:1011-1018. [PMID: 34290197 DOI: 10.1097/j.jcrs.0000000000000562] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Accepted: 12/14/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the accuracy of the methods for calculation of intraocular lens (IOL) power in eyes with previous myopic laser refractive surgery. SETTING EENT Hospital of Fudan University, Shanghai, China. DESIGN Network meta-analysis. METHODS A literature search of MEDLINE and Cochrane Library from January 2000 to July 2019 was conducted for studies that evaluated methods of calculating IOL power in eyes with previous myopic laser refractive surgery. Outcomes measurements were the percentages of prediction error within ±0.50 diopters (D) and ±1.00 D of the target refraction (% ±0.50 D and % ±1.00 D). Traditional and network meta-analysis were conducted. RESULTS Nineteen prospective or retrospective clinical studies, including 1217 eyes and 13 calculation methods, were identified. A traditional meta-analysis showed that compared with the widely used Haigis-L method, the Barrett True-K formula, optical coherence tomography (OCT), and Masket methods showed significantly higher % ±0.50 D, whereas no difference was found in the % ±1.00 D. A network meta-analysis revealed that compared with the Haigis-L method, the OCT, Barrett True-K formula, and optiwave refractive analysis (ORA) methods performed better on the % ±0.50 D, whereas the Barrett True-K formula and ORA methods performed better on the % ±1.00 D. Based on the performances of both outcomes, the Barrett True-K formula, OCT, and ORA methods showed highest probability to rank the top 3 among the 13 methods. CONCLUSIONS The Barrett True-K formula, OCT, and ORA methods seemed to offer greater accuracy than others in calculating the IOL power for postrefractive surgery eyes.
Collapse
Affiliation(s)
- Ling Wei
- From the Department of Ophthalmology and Eye Institute, Eye and ENT Hospital of Fudan University; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science; and Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | | | | | | | | |
Collapse
|
16
|
Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia. J Cataract Refract Surg 2021; 47:304-310. [PMID: 32932366 DOI: 10.1097/j.jcrs.0000000000000405] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 08/03/2020] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same IOL before and after SMILE, was used, and the IOL power calculations were performed using ray tracing (OKULIX, version 9.06) and third- (Hoffer Q, Holladay 1, and SRK/T) and fourth-generation (Haigis-L and Haigis) formulas. The difference between the IOL-induced refractive error at corneal plane before and after SMILE (IOL-Dif) was compared with SMILE-Dif. The prediction error (PE) was calculated as the difference between SMILE-Dif-IOL-Dif. RESULTS The study included 204 eyes that underwent SMILE. The PE with ray tracing was -0.06 ± 0.40 diopter (D); Haigis-L, -0.39 ± 0.62 D; Haigis, 0.70 ± 0.48 D; Hoffer Q, 0.84 ± 0.47 D; Holladay 1, 1.21 ± 0.51 D; and SRK/T, 1.46 ± 0.54 D. The PE with ray tracing was significantly smaller compared with that of all formulas (P ≤ .001). The PE variance with ray tracing was σ2 = 0.159, being significantly more homogenous compared with that of all formulas (P ≤ .011, F ≥ 6.549). Ray tracing resulted in an absolute PE of 0.5 D or lesser in 81.9% of the cases, followed by Haigis-L (53.4%), Haigis (35.3%), Hoffer Q (25.5%), Holladay 1 (6.4%), and SRK/T (2.9%) formulas. CONCLUSIONS Ray tracing was the most accurate approach for IOL power calculation after myopic SMILE.
Collapse
|
17
|
Intraocular lens power calculation using adjusted corneal power in eyes with prior myopic laser vision correction. Graefes Arch Clin Exp Ophthalmol 2021; 259:3729-3737. [PMID: 34287694 DOI: 10.1007/s00417-021-05309-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Revised: 06/20/2021] [Accepted: 07/01/2021] [Indexed: 12/28/2022] Open
Abstract
PURPOSE To evaluate the prediction accuracy of the intraocular lens (IOL) power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio in the Haigis formula (Haigis-E) in patients with a history of prior myopic laser vision correction. METHODS Seventy eyes from 70 cataract patients who underwent cataract surgery and had a history of myopic laser vision correction were enrolled. The adjusted corneal power obtained with conventional keratometry (K) was calculated using the posterior/anterior corneal curvature radii ratio measured by a single Scheimpflug camera. In eyes longer than 25.0 mm, half of the Wang-Koch (WK) adjustment was applied. The median absolute error (MedAE) and the percentage of eyes that achieved a postoperative refractive prediction error within ± 0.50 diopters (D) based on the Haigis-E method was compared with those in the Shammas, Haigis-L, and Barrett True-K no-history methods. RESULTS The MedAE predicted using the Haigis-E (0.33 D) was significantly smaller than that obtained using the Shammas (0.44 D), Haigis-L (0.43 D), and Barrett True-K (0.44 D) methods (P < 0.001, P = 0.001, and P = 0.014, respectively). The percentage of eyes within ± 0.50 D of refractive prediction error using the Haigis-E (78.6%) was significantly greater than that produced using the Shammas (57.1%), Haigis-L (58.6%), and Barrett True-K (61.4%) methods (P = 0.025). CONCLUSION IOL power calculation using the adjusted corneal power according to the posterior/anterior corneal curvature radii ratio and modified WK adjustment in the Haigis formula could improve the refraction prediction accuracy after cataract surgery in eyes with prior myopic laser vision correction.
Collapse
|
18
|
Fu D, Shang J, Zhang X, Niu L, Han T, Zhou X. Scheimpflug analysis of corneal power changes after hyperopic small incision lenticule extraction. BMC Ophthalmol 2021; 21:282. [PMID: 34284749 PMCID: PMC8293571 DOI: 10.1186/s12886-021-02043-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 07/09/2021] [Indexed: 11/10/2022] Open
Abstract
Purpose To assess the ability of the Pentacam in predicting the corneal power after hyperopic small-incision lenticule extraction (SMILE). Methods Twenty-five eyes of 22 patients underwent hyperopic SMILE were prospectively followed. All patients finished at least 6 months visit. Cornea power was obtained by Pentacam HR, in the format of mean keratometry (Km), equivalent keratometry (EKR) and total cornea refractive power (TCRP). Calculation of TCRP were centered on either the corneal apex or the pupil center within a ring or zone, giving a total of four different subtypes naming AR、AZ、PR、PZ. Clinical history method (CHM) was regarded as a gold standard and was compared with other cornea power parameters. Results Center difference had no impact on the TCRP values (PR vs AR and PZ vs AZ, P > 0.05). Compared with CHM, no difference was found in Km, EKR 4.0 mm, EKR 4.5 mm, PR 3.0 mm, PR 4.0 mm, AR 3.0 mm and AR 4.0 mm. PR 4.0 mm showed the least difference with CHM (− 0.14 ± 1.03D, P > 0.05). The 95% limit of agreement (LOA) of the TCRPs and CHM was not close. The top two were PR 3.0 mm and PR 4.0 mm, LOA of which were − 2.20 to 1.84 D and − 2.18 to 1.68 D respectively. Central cornea thickness was correlated with error (TCRP – CHM) of PR 4.0 mm (r = 0.58, P = 0.003). Conclusions The Pentacam topographer is an alternative method of measuring corneal power in eyes after hyperopic SMILE. The optimal options seem to be the TCRP (PR 4.0 mm). The agreement needs more verifications.
Collapse
Affiliation(s)
- Dan Fu
- Eye Institute and Department of Ophthalmology and Vision Science, Eye & ENT Hospital, Fudan University, No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, 20031, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 20031, China
| | - Jianmin Shang
- Eye Institute and Department of Ophthalmology and Vision Science, Eye & ENT Hospital, Fudan University, No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, 20031, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 20031, China
| | - Xiaoyu Zhang
- Eye Institute and Department of Ophthalmology and Vision Science, Eye & ENT Hospital, Fudan University, No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, 20031, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 20031, China
| | - Lingling Niu
- Eye Institute and Department of Ophthalmology and Vision Science, Eye & ENT Hospital, Fudan University, No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, 20031, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 20031, China
| | - Tian Han
- Eye Institute and Department of Ophthalmology and Vision Science, Eye & ENT Hospital, Fudan University, No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China.,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, 20031, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 20031, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology and Vision Science, Eye & ENT Hospital, Fudan University, No.19 Baoqing Road, Xuhui District, Shanghai, 200031, China. .,NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Science, Shanghai, 20031, China. .,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 20031, China.
| |
Collapse
|
19
|
Park SY, Kwag JY, Choi JS, Pak KH, Chung SK. Intraocular Lens Power Calculation Using Shammas-PL Formula after Laser In-situ Keratomileusis. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2021. [DOI: 10.3341/jkos.2021.62.2.201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
20
|
Pantanelli SM, Lin CC, Al-Mohtaseb Z, Rose-Nussbaumer JR, Santhiago MR, Steigleman WA, Schallhorn JM. Intraocular Lens Power Calculation in Eyes with Previous Excimer Laser Surgery for Myopia: A Report by the American Academy of Ophthalmology. Ophthalmology 2021; 128:781-792. [PMID: 33500124 DOI: 10.1016/j.ophtha.2020.10.031] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Revised: 10/27/2020] [Accepted: 10/28/2020] [Indexed: 02/07/2023] Open
Abstract
PURPOSE To review the literature to evaluate the outcomes of intraocular lens (IOL) power calculation in eyes with a history of myopic LASIK or photorefractive keratectomy (PRK). METHODS Literature searches were conducted in the PubMed database in January 2020. Separate searches relevant to cataract surgery outcomes and corneal refractive surgery returned 1169 and 162 relevant citations, respectively, and the full text of 24 was reviewed. Eleven studies met the inclusion criteria for this assessment; all were assigned a level III rating of evidence by the panel methodologist. RESULTS When automated keratometry was used with a theoretical formula designed for eyes without previous laser vision correction, the mean prediction error (MPE) was universally positive (hyperopic), the mean absolute errors (MAEs) and median absolute errors (MedAEs) were relatively high (0.72-1.9 diopters [D] and 0.65-1.73 D, respectively), and a low (8%-40%) proportion of eyes were within 0.5 D of target spherical equivalent (SE). Formulas developed specifically for this population requiring both prerefractive surgery keratometry and manifest refraction (i.e., clinical history, corneal bypass, and Feiz-Mannis) produced a proportion of eyes within 0.5 D of target SE between 26% and 44%. Formulas requiring only preoperative keratometry or no history at all had lower MAEs (0.42-0.94 D) and MedAEs (0.30-0.81 D) and higher (30%-68%) proportions within 0.5 D of target SE. Strategies that averaged several methods yielded the lowest reported MedAEs (0.31-0.35 D) and highest (66%-68%) proportions within 0.5 D of target SE. Even after using the best-known methods, refractive outcomes were less accurate in eyes that had previous excimer laser surgery for myopia compared with those that did not have it. CONCLUSIONS Calculation methods requiring both prerefractive surgery keratometry and manifest refraction are no longer considered the gold standard. Refractive outcomes of cataract surgery in eyes that had previous excimer laser surgery are less accurate than in eyes that did not. Patients should be advised of this refractive limitation when considering cataract surgery in the setting of previous corneal refractive surgery. Conclusions are limited by the small sample sizes and retrospective nature of nearly all existing literature in this domain.
Collapse
Affiliation(s)
| | - Charles C Lin
- Byers Eye Institute, Stanford University, Palo Alto, California
| | | | - Jennifer R Rose-Nussbaumer
- Division of Research Kaiser Permanente Northern California and Francis I Proctor Foundation University of California, San Francisco, California
| | | | | | - Julie M Schallhorn
- Francis I. Proctor Foundation and Department of Ophthalmology, University of California, San Francisco, California
| |
Collapse
|
21
|
Patel P, Ashena Z, Vasavada V, Vasavada SA, Vasavada V, Sudhalkar A, Nanavaty MA. Comparison of intraocular lens calculation methods after myopic laser-assisted in situ keratomileusis and radial keratotomy without prior refractive data. Br J Ophthalmol 2020; 106:47-53. [PMID: 33093154 DOI: 10.1136/bjophthalmol-2020-317681] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2020] [Revised: 09/22/2020] [Accepted: 10/03/2020] [Indexed: 11/03/2022]
Abstract
AIM To compare intraocular lens (IOL) calculation methods not requiring refraction data prior to myopic laser-assisted in situ keratomileusis (LASIK) and radial keratotomy (RK). METHODS In post-LASIK eyes, the methods not requiring prior refraction data were Hagis-L; Shammas; Barrett True-K no-history; Wang-Koch-Maloney; 'average', 'minimum' and 'maximum' IOL power on the American Society of Cataract and Refractive Surgeons (ASCRS) IOL calculator. Double-K method and Barrett True-K no-history, 'average', 'minimum' and 'maximum' IOL power on ASCRS IOL calculator were evaluated in post-RK eyes. The predicted IOL power was calculated with each method using the manifest postoperative refraction. Arithmetic and absolute IOL prediction errors (PE) (implanted-predicted IOL powers), variances in arithmetic IOL PE and percentage of eyes within ±0.50 and ±1.00 D of refractive PE were calculated. RESULTS Arithmetic or absolute IOL PE were not significantly different between the methods in post-LASIK and post-RK eyes. In post-LASIK eyes, 'average' showed the highest and 'minimum' showed the least variance, whereas 'average' and 'minimum' had highest percentage of eyes within ±0.5 D and 'minimum' had the highest percentage of eyes within ±1.0 D. In the post-RK eyes, 'minimum' had highest variance, and 'average' had the least variance and highest percentage of eyes within ±0.5 D and ±1.0 D. CONCLUSION In post-LASIK and post-RK eyes, there are no significant differences in IOL PE between the methods not requiring prior refraction data. 'Minimum' showed least variance in PEs and more chances of eyes to be within ±1.0 D postoperatively in post-LASIK eyes. 'Average' had least variance and more chance of eyes within ±1.0 D in post-RK eyes.
Collapse
Affiliation(s)
- Priyanka Patel
- Iladevi Cataract and IOL Research Center, Ahmedabad, India
| | - Zahra Ashena
- Sussex Eye Hospital, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK
| | - Viraj Vasavada
- Iladevi Cataract and IOL Research Center, Ahmedabad, India
| | | | | | | | - Mayank A Nanavaty
- Sussex Eye Hospital, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK .,Brighton and Sussex Medical School, Brighton, BN1 9PX, United Kingdom
| |
Collapse
|
22
|
Rosa N, Cione F, Pepe A, Musto S, De Bernardo M. An Advanced Lens Measurement Approach (ALMA) in post refractive surgery IOL power calculation with unknown preoperative parameters. PLoS One 2020; 15:e0237990. [PMID: 32841281 PMCID: PMC7447029 DOI: 10.1371/journal.pone.0237990] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Accepted: 08/06/2020] [Indexed: 12/23/2022] Open
Abstract
PURPOSE To test a new method to calculate the Intraocular Lens (IOL) power, that combines R Factor and ALxK methods, that we called Advance Lens Measurement Approach (ALMA). DESIGN Retrospective, Comparative, Observational study. SETTING Department of Medicine and Surgery, University of Salerno, Italy. METHODS Ninety one eyes of 91 patients previously treated with Photorefractive Keratectomy (PRK) or Laser-Assisted in Situ Keratomileusis (LASIK) that underwent phacoemulsification and IOL implantation in the capsular bag were analyzed. For 68 eyes it was possible to zero out the Mean Errors (ME) for each formula and for selected IOL models, in order to eliminate the bias of the lens factor (A-Costant). Main outcome, measured in this study, was the median absolute error (MedAE) of the refraction prediction. RESULTS In the sample with ME zeroed (68 eyes) both R Factor and ALxK methods resulted in MedAE of 0.67 D. For R Factor 33 eyes (48.53%) reported a refractive error <0.5D, and 53 eyes (77.94%) reported a refractive error <1D, For ALxK method, 32 eyes (47.06%) reported a refractive error <0.5 D, and 53 eyes (77.94%) reported a refractive error <1 D. ALMA method, reported a MedAE of 0.55 D, and an higher number of patients with a refractive error <0.5 D (35 eyes, 51.47%), and with a refractive error <1 D (54 eyes, 79.41%). CONCLUSIONS Based on the results obtained from this study, ALMA method can improve R Factor and ALxK methods. This improvement is confirmed both by zeroing the mean error and without zeroing it.
Collapse
Affiliation(s)
- Nicola Rosa
- Department of Medicine, Surgery and Dentistry “Scuola Medica Salernitana”, University of Salerno, Salerno, Italy
| | - Ferdinando Cione
- Department of Medicine, Surgery and Dentistry “Scuola Medica Salernitana”, University of Salerno, Salerno, Italy
| | - Angela Pepe
- Department of Medicine, Surgery and Dentistry “Scuola Medica Salernitana”, University of Salerno, Salerno, Italy
| | - Salvatore Musto
- Department of Medicine, Surgery and Dentistry “Scuola Medica Salernitana”, University of Salerno, Salerno, Italy
| | - Maddalena De Bernardo
- Department of Medicine, Surgery and Dentistry “Scuola Medica Salernitana”, University of Salerno, Salerno, Italy
- * E-mail:
| |
Collapse
|
23
|
Wen D, Yu J, Zeng Z, McAlinden C, Hu L, Feng K, Wang Y, Song B, Chen S, Ning R, Jin Y, Wang Q, Yu AY, Huang J. Network Meta-analysis of No-History Methods to Calculate Intraocular Lens Power in Eyes With Previous Myopic Laser Refractive Surgery. J Refract Surg 2020; 36:481-490. [PMID: 32644171 DOI: 10.3928/1081597x-20200519-04] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Accepted: 05/19/2020] [Indexed: 01/10/2024]
Abstract
PURPOSE To systematically compare and rank the predictability of no-history intraocular lens (IOL) power calculation methods after myopic laser refractive surgery. METHODS PubMed, Embase, the Cochrane Library, and the U.S. trial registry (www.ClinicalTrial.gov) were used to systematically search trials published up to August 2019. Included were case series studies reporting the following outcomes in patients with cataract undergoing phacoemulsification after laser refractive surgery: percentage of eyes with a refractive prediction error (PE) within ±0.50 and ±1.00 diopters (D), mean absolute error (MAE), and median absolute error (MedAE). A network meta-analysis was conducted using the STATA software version 13.1 (STATACorp LLC). RESULTS Nineteen studies involving 1,098 eyes and 19 formulas were identified. A network meta-analysis for the percentage of eyes with a PE within ±0.50 D found that ray-tracing (Okulix), intraoperative aberrometry (Optiwave Refractive Analysis [ORA]), BESSt, and Seitz/Speicher/Savini (Triple-S) (D-K SRK/T), and Fourier-Domain OCT-Based formulas were more predictive than the Wang/Koch/Maloney, Shammas-PL, modified Rosa, Ferrara, and Equivalent K reading at 4.5 mm using the Double-K Holladay 1 formulas. With regard to ranking, the top four formulas as per the surface under the cumulative ranking curve (SUCRA) values for the percentage of eyes with a PE within ±0.50 D were the Okulix, ORA, BESSt, and Triple-S (D-K SRK/T). With regard to MAE, the ORA showed lower errors when compared to the Shammas-PL formula. In this regard, the top four formulas based on the SUCRA values were the Triple-S, BESSt, ORA, and Fourier-Domain OCT-Based formulas. The SToP (SRK/T), ORA, Fourier-Domain OCT-Based, and BESSt formulas had the lowest MedAE. CONCLUSIONS Considering all three outcome measures of highest percentages of eyes with a PE within ±0.50 and ±1.00 D, lowest MAE, and lowest MedAE, the top three no-history formulas for IOL power calculation in eyes with previous myopic corneal laser refractive surgery were: ORA, BESSt, and Triple-S (D-K SRK/T). [J Refract Surg. 2020;36(7):481-490.].
Collapse
|
24
|
Comparative postoperative topography pattern recognition analysis using axial vs tangential curvature maps. J Cataract Refract Surg 2020; 46:1368-1373. [PMID: 32483077 DOI: 10.1097/j.jcrs.0000000000000264] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine prediction accuracy of patient refractive surgery status by novice reviewers based on topography pattern analysis using axial or tangential anterior curvature maps. SETTING Four U.S. academic centers. DESIGN Prospective case-control study. METHODS Image evaluation was performed by novice reviewers (n = 52) at 4 academic institutions. Participants were shown 60 total images from 30 eyes presenting for cataract surgery evaluation with known refractive surgery status, including 12 eyes imaged with Placido-based topography and 18 eyes imaged with Scheimpflug-based tomography. There were 12 eyes with myopic ablations, 12 eyes with hyperopic ablations, and 6 eyes with no previous refractive surgery performed. Each eye was shown in both axial and tangential curvature from either device, reviewed as a single image at a time, and masked to the map type (axial vs tangential). RESULTS For the 52 novice reviewers included, accuracy of pattern identification was 82.9% (517 of 624) for tangential vs 55.0% (343 of 624) for axial maps for eyes with myopic ablation (P < .00001), 90.9% (567 of 624) for tangential vs 58.3% (364 of 624) for axial maps for eyes with hyperopic ablation (P < .00001), and 15.4% (48 of 312) for tangential vs 62.8% (196 of 312) for axial maps for eyes with no ablation (P < .00001). There were no significant differences between Placido and Scheimpflug devices and no significant differences across groups based on year of training. CONCLUSIONS Tangential curvature maps yielded significantly better pattern recognition accuracy compared with axial maps after myopic and hyperopic corneal refractive surgery ablations for novice reviewers. Using tangential curvature maps, especially for challenging cases, should benefit post-LASIK intraocular lens (IOL) calculator selection and, thereby, improve IOL power calculation accuracy.
Collapse
|
25
|
New method for intraocular lens power calculation using a rotating Scheimpflug camera in eyes with corneal refractive surgery. Sci Rep 2020; 10:8992. [PMID: 32488057 PMCID: PMC7265558 DOI: 10.1038/s41598-020-65827-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2020] [Accepted: 05/07/2020] [Indexed: 11/08/2022] Open
Abstract
To introduce and evaluate a refraction-based method for calculating the correct power of the intraocular lens (IOL) in eyes with corneal refractive surgery and to compare the results here to previously published methods. Retrospective review of medical records was done. Group 1 was used to derive two formulas. From the relevant IOL calculation and postoperative refractive data, the refraction-derived K values (Krd) were calculated using a linear regression analysis. The values obtained with the two formulas were compared to previously published methods in group 2 to validate the results. The following methods were evaluated: Haigis-L, Barrett True-K (no history), Potvin-Hill, BESSt 2, Scheimpflug total corneal refractive power (TCRP) 4 mm (Haigis), Scheimpflug total refractive power (TRP) 4 mm (Haigis), modified Scheimpflug TCRP 4 mm (Haigis), and modified Scheimpflug TRP 4 mm (Haigis). The modified TCRP 4 mm Krd (Haigis) had good outcomes, with 60% and 90% of eyes within ±0.50 D and ±1.00 D of the refractive target, respectively. A new method using modified Scheimpflug total corneal refractive power in the 4.0 mm zone appeared to be an accurate method for determining IOL power in eyes with corneal refractive surgery.
Collapse
|
26
|
Xia T, Martinez CE, Tsai LM. Update on Intraocular Lens Formulas and Calculations. Asia Pac J Ophthalmol (Phila) 2020; 9:186-193. [PMID: 32501896 PMCID: PMC7299214 DOI: 10.1097/apo.0000000000000293] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 04/04/2020] [Indexed: 12/13/2022] Open
Abstract
Investigators, scientists, and physicians continue to develop new methods of intraocular lens (IOL) calculation to improve the refractive accuracy after cataract surgery. To gain more accurate prediction of IOL power, vergence lens formulas have incorporated additional biometric variables, such as anterior chamber depth, lens thickness, white-to-white measurement, and even age in some algorithms. Newer formulas diverge from their classic regression and vergence-based predecessors and increasingly utilize techniques such as exact ray-tracing data, more modern regression models, and artificial intelligence. This review provides an update on recent literature comparing the commonly used third- and fourth-generation IOL formulas with newer generation formulas. Refractive outcomes with newer formulas are increasingly more and more accurate, so it is important for ophthalmologists to be aware of the various options for choosing IOL power. Historically, refractive outcomes have been especially unpredictable in patients with unusual biometry, corneal ectasia, a history of refractive surgery, and in pediatric patients. Refractive outcomes in these patient populations are improving. Improved biometry technology is also allowing for improved refractive outcomes and surgery planning convenience with the availability of newer formulas on various biometry platforms. It is crucial for surgeons to understand and utilize the most accurate formulas for their patients to provide the highest quality of care.
Collapse
Affiliation(s)
- Tina Xia
- John F Hardesty MD Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis MO
| | | | | |
Collapse
|
27
|
Calculation of the Real Corneal Refractive Power after Photorefractive Keratectomy Using Pentacam, When Only the Preoperative Refractive Error is Known. J Ophthalmol 2020; 2020:1916369. [PMID: 32318276 PMCID: PMC7152949 DOI: 10.1155/2020/1916369] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 02/10/2020] [Accepted: 02/17/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose To check if a regression formula, IOLMaster-derived, to calculate the real corneal power after photorefractive keratectomy (PRK), can give reliable results utilizing the Pentacam. Methods Pre- and postoperative IOLMaster, Km, and Pentacam K readings were measured. Patients who had myopic PRK were divided into two groups: the first group (108 eyes) was utilized to check which of the preop Pentacam K readings (P-Kpre) better fitted with the preop IOLMaster measurements; in the second group (120 eyes), the real K (Kr), obtained adding the effective treatment to the P-Kpre, were compared with the K readings calculated with the IOLMaster-derived formula (Kc). Moreover, an attempt to find a different formula utilizing the P-Kpre was made. Results In group 1, the best correlation was found between IOLMaster Km and Pentacam equivalent K readings (r2 0.9519). In group 2, the comparison between Kr and Pentacam postop Km showed 69 eyes (57%) with differences >0.5 D and 38 eyes (31%) with differences >1 D, (P < 0.001). The comparison between Kr and Kc showed 55 eyes (45%) with differences >0.5 D and 22 eyes (18%) with differences >1 D, (P < 0.001). Moreover, a regression formula K = EKR - [ETcp + (0.8114 ∗ ETcp - 0.2031)] was obtained in order to calculate the K readings to be used with the Pentacam in the IOL power calculation in case the effective treatment is known. Conclusions K calculated with the new formula could be used in patients that underwent refractive corneal surgery in case a Pentacam device is used, pending further studies conducted in clinical practice to establish its accuracy and effectiveness. This study further proves that data obtained from different machines cannot be used interchangeably.
Collapse
|
28
|
Pan C, Tan W, Hua Y, Lei X. Corneal power measurement with a new aberrometer/corneal topographer in eyes after small incision lenticule extraction for myopia. Int Ophthalmol 2019; 39:2815-2824. [PMID: 31134424 DOI: 10.1007/s10792-019-01128-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2018] [Accepted: 05/22/2019] [Indexed: 11/27/2022]
Abstract
PURPOSE To assess corneal power measurements obtained by the OPD SCAN III Topographer in eyes with prior myopic small incision lenticule extraction (SMILE) surgery. METHODS Sixty untreated myopic eyes of sixty subjects and forty previous myopic SMILE surgery eyes of forty subjects were consecutively enrolled in the present study. Manifest refraction, OPD SCAN III and Pentacam HR were performed. Keratometric measurements assessed by OPD SCAN III-simulated keratometry, average pupil power and effective central corneal power (ECCP) were compared with mean keratometry (Km) obtained by Pentacam HR in the untreated group and the clinical history method (CHM) in the treated group. RESULTS In the untreated group, no statistically significant differences were revealed between all corneal power measurements obtained with OPD SCAN III and Km. In the treated group, all the corneal power measurements were statistically different from the CHM except for the Haigis method and the Shammas method, while ECCP had a statistically but not clinically significant overestimation of 0.42 D with 95% limit of agreement (LOA) of - 0.81 D to 1.64 D. The three modified ECCP had better prediction performance with narrower 95% of LOA lying in (- 1.20, 1.20 D) (- 1.22, 1.23 D) and (- 0.90, 1.00 D), respectively. CONCLUSIONS The ECCP provided with OPD SCAN III could be used as an alternative option for the CHM after specific modifications in eyes with previous myopic SMILE surgery when the preoperative data are unavailable considering the narrowest agreement between the modified ECCP and the CHM. Otherwise, caution must be raised considering the wide LOA.
Collapse
Affiliation(s)
- Chao Pan
- Hankou Aier Eye Hospital, 34 Machang Road, Jianghan District, Wuhan, Hubei Province, China
| | - Weina Tan
- Hankou Aier Eye Hospital, 34 Machang Road, Jianghan District, Wuhan, Hubei Province, China
| | - Yanjun Hua
- Department of Ophthalmology, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Xuhui District, Shanghai, China
| | - Xiaohua Lei
- Hankou Aier Eye Hospital, 34 Machang Road, Jianghan District, Wuhan, Hubei Province, China.
| |
Collapse
|
29
|
Cho K, Lim DH, Yang CM, Chung ES, Chung TY. Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera. KOREAN JOURNAL OF OPHTHALMOLOGY 2019; 32:497-505. [PMID: 30549474 PMCID: PMC6288016 DOI: 10.3341/kjo.2018.0008] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Accepted: 04/10/2018] [Indexed: 11/24/2022] Open
Abstract
Purpose To evaluate and compare published methods of calculating intraocular lens (IOL) power following myopic laser refractive surgery. Methods We performed a retrospective review of the medical records of 69 patients (69 eyes) who had undergone myopic laser refractive surgery previously and subsequently underwent cataract surgery at Samsung Medical Center in Seoul, South Korea from January 2010 to June 2016. None of the patients had pre-refractive surgery biometric data available. The Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug total corneal refractive power (TCRP) 3 and 4 mm (SRK-T and Haigis), Scheimpflug true net power, and Scheimpflug true refractive power (TRP) 3 mm, 4 mm, and 5 mm (SRK-T and Haigis) methods were employed. IOL power required for target refraction was back-calculated using stable post-cataract surgery manifest refraction, and implanted IOL power and formula accuracy were subsequently compared among calculation methods. Results Haigis-L, Shammas, Barrett True-K (no history), Wang-Koch-Maloney, Scheimpflug TCRP 4 mm (Haigis), Scheimpflug true net power 4 mm (Haigis), and Scheimpflug TRP 4 mm (Haigis) formulae showed high predictability, with mean arithmetic prediction errors and standard deviations of −0.25 ± 0.59, −0.05 ± 1.19, 0.00 ± 0.88, −0.26 ± 1.17, 0.00 ± 1.09, −0.71 ± 1.20, and 0.03 ± 1.25 diopters, respectively. Conclusions Visual outcomes within 1.0 diopter of target refraction were achieved in 85% of eyes using the calculation methods listed above. Haigis-L, Barrett True-K (no history), and Scheimpflug TCRP 4 mm (Haigis) and TRP 4 mm (Haigis) methods showed comparably low prediction errors, despite the absence of historical patient information.
Collapse
Affiliation(s)
- Kyuyeon Cho
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Dong Hui Lim
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Chan Min Yang
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | | | - Tae Young Chung
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
| |
Collapse
|
30
|
Hsieh YH, Weng TH, Chou YC, Wu KL, Liang CM, Tai MC. Agreement of post-LASIK corneal power and corneal thickness measurements by pentacam and GALILEI corneal tomography systems. J Chin Med Assoc 2019; 82:72-77. [PMID: 30839408 DOI: 10.1016/j.jcma.2018.07.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
Abstract
BACKGROUND Post-LASIK corneal conditions cannot be accurately measured by traditional optometric approaches. Therefore, we aimed to analyze the agreement of two rotating Scheimpflug cameras in corneal assessment. METHODS Fifty otherwise healthy volunteers who had undergone LASIK were recruited in this study. The values of mean and central total corneal power (TCP), including TCP1, TCP2, and TCP-IOL, were measured by GALILEI Scheimpflug camera. The values of total corneal refractive power (TCRP) readings at both 2 mm ring and 3 and 4 mm zones were detected by Pentacam Scheimpflug camera. Central corneal thickness (CCT) and thinnest corneal thickness (TCT) were quantified by GALILEI and Pentacam respectively. Paired t-tests and Bland-Altman analyses were used to evaluate statistical differences between measurement results obtained by GALILEI and by Pentacam. RESULTS Among these 50 subjects, the mean and central TCP1 values (37.31 ± 2.61 and 37.27 ± 2.64) derived from GALILEI measurements were consistent with the TCRP values (37.08 ± 2.76, 37.11 ± 2.74, and 37.19 ± 2.68; p > 0.05) determined by Pentacam at the 2 mm ring apex, 3 mm zone apex, and 4 mm zone apex. There were no statistically significant differences in central corneal thickness (CCT) values measured by the two cameras (463.64 ± 55.67 μm for GALILEI and 470.69 ± 44.04 μm for Pentacam, respectively; p > 0.05). However, the limits of agreement were wide when comparing mean TCP1 (-1.4 to 1.8 D, -1.4 to 1.8 D, and -1.3 to 1.6 D), central TCP1 (-1.2 to 1.6 D, -1.2 to 1.6 D, and -1.2 to 1.4 D) and CCT (-77.2-63.0 μm). CONCLUSION Corneal power and corneal thickness are disparate post-LASIK evaluation parameters when comparing the utility of GALILEI with that of Pentacam.
Collapse
Affiliation(s)
- Yun-Hsiu Hsieh
- Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC
| | - Tzu-Heng Weng
- Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC
| | - Yu-Ching Chou
- School of Public Health, National Defense Medical Center, Taipei, Taiwan, ROC
| | - Kuan-Liang Wu
- National Defense Medical Center, Taipei, Taiwan, ROC
| | - Chang-Min Liang
- Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC
| | - Ming-Cheng Tai
- Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, ROC
| |
Collapse
|
31
|
Savini G, Hoffer KJ. Intraocular lens power calculation in eyes with previous corneal refractive surgery. EYE AND VISION 2018; 5:18. [PMID: 30038922 PMCID: PMC6053834 DOI: 10.1186/s40662-018-0110-5] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2018] [Accepted: 06/22/2018] [Indexed: 01/14/2023]
Abstract
Background This review aims to explain the reasons why intraocular lens (IOL) power calculation is challenging in eyes with previous corneal refractive surgery and what solutions are currently available to obtain more accurate results. Review After IOL implantation in eyes with previous LASIK, PRK or RK, a refractive surprise can occur because i) the altered ratio between the anterior and posterior corneal surface makes the keratometric index invalid; ii) the corneal curvature radius is measured out of the optical zone; and iii) the effective lens position is erroneously predicted if such a prediction is based on the post-refractive surgery corneal curvature. Different methods are currently available to obtain the best refractive outcomes in these eyes, even when the perioperative data (i.e. preoperative corneal power and surgically induced refractive change) are not known. In this review, we describe the most accurate methods based on our clinical studies. Conclusions IOL power calculation after myopic corneal refractive surgery can be calculated with a variety of methods that lead to relatively accurate outcomes, with 60 to 70% of eyes showing a prediction error within 0.50 diopters.
Collapse
Affiliation(s)
| | - Kenneth J Hoffer
- 2Stein Eye Institute, University of California, Los Angeles, CA USA.,St. Mary's Eye Center, Santa Monica, CA USA
| |
Collapse
|
32
|
Chia TMT, Jung HC. Cataract Surgery following Sequential Myopic and Hyperopic LASIK. Case Rep Ophthalmol 2018; 9:264-268. [PMID: 29928221 PMCID: PMC6006602 DOI: 10.1159/000488849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 03/26/2018] [Indexed: 12/02/2022] Open
Abstract
We report a case of patient dissatisfaction after sequential myopic and hyperopic LASIK in the same eye. We discuss the course of management for this patient involving eventual cataract extraction and intraocular lens (IOL) implantation with attention to the IOL power calculation method used.
Collapse
Affiliation(s)
- Tao Ming Thomas Chia
- University of Southern California - Roski Eye Institute, Los Angeles, California, USA
| | - Hoon C Jung
- University of Washington, Veterans Affairs Puget Sound Hospital Department of Ophthalmology, Seattle, Washington, USA
| |
Collapse
|
33
|
Wei P, Wang Y, Chan TC, Ng AL, Cheng GP, Jhanji V. Determining total corneal power after small-incision lenticule extraction in myopic eyes. J Cataract Refract Surg 2017; 43:1450-1457. [DOI: 10.1016/j.jcrs.2017.08.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Revised: 08/10/2017] [Accepted: 08/13/2017] [Indexed: 10/18/2022]
|
34
|
Abulafia A, Hill WE, Wang L, Reitblat O, Koch DD. Intraocular Lens Power Calculation in Eyes After Laser In Situ Keratomileusis or Photorefractive Keratectomy for Myopia. Asia Pac J Ophthalmol (Phila) 2017; 6:332-338. [PMID: 28780776 DOI: 10.22608/apo.2017187] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Accepted: 07/25/2017] [Indexed: 11/08/2022] Open
Abstract
Intraocular power calculation is challenging for patients who have previously undergone corneal refractive surgery. The sources of prediction errors for these eyes are well known; however, the numerous formulas and methods available for calculating intraocular lens power in these cases are eloquent testimony to the absence of a definitive solution. This review discusses some of the available methods for improving the accuracy for predicting the refractive outcome for these patients. It focuses mainly on the methods available on the American Society of Cataract and Refractive Surgery (ASCRS) online calculator and provides some practical guidelines for cataract surgeons who encounter these challenging cases.
Collapse
Affiliation(s)
- Adi Abulafia
- Shaare Zedek Medical Centre, Jerusalem, Israel
- Hebrew University of Jerusalem, Jersusalem, Israel
| | | | - Li Wang
- Cullen Eye Institute, Baylor College of Medicine, Houston, Texas
| | - Olga Reitblat
- Shaare Zedek Medical Centre, Jerusalem, Israel
- Hebrew University of Jerusalem, Jersusalem, Israel
| | - Douglas D Koch
- Cullen Eye Institute, Baylor College of Medicine, Houston, Texas
| |
Collapse
|
35
|
Kang BS, Han JM, Oh JY, Kim MK, Wee WR. Intraocular Lens Power Calculation after Refractive Surgery: A Comparative Analysis of Accuracy and Predictability. KOREAN JOURNAL OF OPHTHALMOLOGY 2017; 31:479-488. [PMID: 28913996 PMCID: PMC5726982 DOI: 10.3341/kjo.2016.0078] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Accepted: 11/01/2016] [Indexed: 11/23/2022] Open
Affiliation(s)
- Byeong Soo Kang
- Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea
| | - Jeong Mo Han
- Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea
| | - Joo Youn Oh
- Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea.,Laboratory of Ocular Regenerative Medicine and Immunology, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| | - Mee Kum Kim
- Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea.,Laboratory of Ocular Regenerative Medicine and Immunology, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea.
| | - Won Ryang Wee
- Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea.,Laboratory of Ocular Regenerative Medicine and Immunology, Biomedical Research Institute, Seoul National University Hospital, Seoul, Korea
| |
Collapse
|
36
|
Wu Y, Liu S, Liao R. Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery. BMC Ophthalmol 2017; 17:44. [PMID: 28390411 PMCID: PMC5385019 DOI: 10.1186/s12886-017-0439-x] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2016] [Accepted: 04/05/2017] [Indexed: 11/14/2022] Open
Abstract
Background This study aimed to evaluate the prediction accuracy of postoperative refractions using partial coherence interferometry (IOL-Master) and applanation ultrasound (AL-3000) assisted with corneal topography (TMS-4) in eyes that had undergone myopic laser-assisted in situ keratomileusis (LASIK). Methods Haigis-L formula, Koch–Maloney method using Haigis formula, Shammas clinically derived K-value (simulated keratometric value) correction (Shammas c.d.) using Haigis formula, and Shammas post-LASIK (Shammas-PL) formula were used in eyes with myopic LASIK. Constants were derived from the optimized constants in 133 virgin eyes. Refractive outcomes were determined by streak retinoscopy and subjective manifest refraction. Methods and formulas were evaluated by mean error (ME), standard deviation (SD), range of error, mean absolute error (MAE), median absolute error, 95% confidence interval of MAE, and percentage of eyes within ±0.5 diopter (D), ±1.0 D, and ±1.5 D of prediction. Results SDs of the Haigis-L, Koch-Maloney method using the Haigis formula, Shammas c.d. using the Haigis formula, and the Shammas-PL formula using IOL-Master were 0.721, 0.695, 0.695, and 0.698; and those using AL-3000 assisted with TMS-4 were 0.782, 0.741, 0.743, and 0.778, respectively. Conclusions No-history methods that corrected corneal power with measurements using IOL-Master were promising in myopic post-LASIK eyes, but still a gap in prediction accuracy exists between virgin eyes and post-LASIK eyes. Electronic supplementary material The online version of this article (doi:10.1186/s12886-017-0439-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Yubo Wu
- Department of Ophthalmology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui, 230022, China
| | - Songyu Liu
- Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui, 230022, China
| | - Rongfeng Liao
- Department of Ophthalmology, The First Affiliated Hospital of Anhui Medical University, No. 218 Jixi Road, Hefei, Anhui, 230022, China.
| |
Collapse
|
37
|
Myopic Laser Corneal Refractive Surgery Reduces Interdevice Agreement in the Measurement of Anterior Corneal Curvature. Eye Contact Lens 2017; 44 Suppl 1:S151-S157. [PMID: 28346277 DOI: 10.1097/icl.0000000000000364] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To investigate interdevice differences and agreement in the measurement of anterior corneal curvature obtained by different technologies after laser corneal refractive surgery. METHODS The prospective study comprised 109 eyes of 109 consecutive patients who had undergone laser-assisted in situ keratomileusis (LASIK). Preoperative and postoperative corneal parameters were measured by Scheimpflug imaging (Pentacam), Placido-slit-scanning (Orbscan) and auto-keratometry (IOLMaster). Preoperative and postoperative anterior corneal curvatures (K readings) were compared between devices. Interdevice agreement was evaluated by Bland-Altman analysis. RESULTS Preoperatively, the difference of K reading for Pentacam-IOLMaster (0.04±0.20 D) was not statistically significant (P=0.059). The differences between Pentacam-Orbscan and Orbscan-IOLMaster were 0.20±0.34 D (P<0.001) and -0.17±0.29 D (P<0.001), respectively. After surgery, no difference was found for Pentacam-Orbscan (-0.05±0.38, P=0.136). The differences between Pentacam-IOLMaster and Orbscan-IOLMaster were 0.13±0.29 D (P<0.001) and 0.19±0.34 D (P<0.001). Preoperative interdevice agreement (95% limit of agreement [LOA]) between Pentacam and Orbscan, Pentacam and IOLMaster, and Orbscan and IOLMaster were 1.31 D, 0.79 D and 1.14 D, respectively. The 95% LOAs decreased to 1.47 D, 1.14 D, and 1.34 D after refractive surgery. CONCLUSION Corneal refractive surgery changed the preoperative and postoperative interdevice differences in corneal curvature measurements and reduced interdevice agreement, indicating that the devices are not interchangeable.
Collapse
|
38
|
Diakonis VF, Yesilirmak N, Kymionis GD, Yoo SH. Intraocular lens power overestimation in a patient with history of circling keratorraphy. Saudi J Ophthalmol 2017; 30:198-200. [PMID: 28210183 PMCID: PMC5299111 DOI: 10.1016/j.sjopt.2016.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2015] [Revised: 02/02/2016] [Accepted: 06/12/2016] [Indexed: 11/24/2022] Open
Abstract
We report a case of cataract extraction and intraocular lens (IOL) power overestimation in a patient with history of hyperopia managed with circling keratorraphy. A 65-year-old female presented to our institute complaining of decreased vision in both eyes. The patient had a history of bilateral hyperopia that was managed 20 years ago (1994) with circling keratorraphy. At presentation her uncorrected distance visual acuity (UDVA) was 20/70 and 20/60 in her right eye (OD) and left eye (OS), respectively, while her corrected distance visual acuity (CDVA) was 20/25 OD and 20/25 OS with manifest refraction of −0.50 + 1.50 × 75 OD and +0.50sph + 1.50cyl × 30 OS. Slit lamp examination revealed the presence of a circular intrastromal corneal suture (6 mm diameter) and mild (+1) nuclear sclerosis in both eyes. The patient was scheduled to undergo cataract extraction targeting plano, using a toric IOL; one month after the surgery, the manifest refraction of the operated right eye was −2.00 + 0.50 × 175, reflecting an overestimation of the intraocular lens (IOL) power for the attempted target. Cataract extraction in patients with history of circling keratorraphy for the management of hyperopia results in IOL power overestimation, consistent with that which is seen in patients with other previous hyperopic corneal refractive procedures.
Collapse
Affiliation(s)
- Vasilios F Diakonis
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Nilufer Yesilirmak
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - George D Kymionis
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Sonia H Yoo
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA
| |
Collapse
|
39
|
|
40
|
Abstract
PURPOSE OF REVIEW This article describes different strategies for corneal measurements and/or intraocular lens (IOL) calculations and proposes a systematic approach for IOL selection in patients who have undergone laser corneal refractive surgery. RECENT FINDINGS Corneal measurements and IOL calculations cannot be obtained accurately with the standard measuring technologies and formulas in patients with history of laser corneal refractive surgery; therefore a variety of methods and formulas, some of which required prerefractive surgery data, have been proposed to improve the accuracy of measurements and calculations. Formulas that do not rely on prerefractive data seem to be as accurate as those that do; therefore the lack of prerefractive data no longer presents an obstacle for accurate IOL selection in these patients. SUMMARY Postrefractive patients undergoing cataract extraction and IOL implantation should have corneal measurements and IOL calculations that take into account and compensate for the limitations in accurate measurements and calculations. IOL selection should also aim to compensate for induced spherical aberration according to the ablation pattern.
Collapse
|
41
|
Zhang B, Ma JX, Liu DY, Guo CR, Du YH, Guo XJ, Cui YX. Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction. Int J Ophthalmol 2016; 9:1276-82. [PMID: 27672591 DOI: 10.18240/ijo.2016.09.07] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2015] [Accepted: 11/16/2015] [Indexed: 12/30/2022] Open
Abstract
AIM To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism. METHODS Fifty-seven patients with toric intraocular lens (IOL) implantation and posterior corneal astigmatism exceeding 0.5 diopter were enrolled in this retrospective study. The keratometric astigmatism (KA) and total corneal astigmatism (TA) were measured using a Pentacam rotating Scheimpflug camera to assess the outcomes of AcrySof IOL implantation. Toric IOLs were evaluated in 26 eyes using KA measurements and in 31 eyes using TA measurements. Preoperative corneal astigmatism and postoperative refractive astigmatism were recorded for statistical analysis. The cylindrical power of toric IOLs was estimated in all eyes. RESULTS In all cases, the difference of toric IOL astigmatism magnitude between KA and TA measurements for the estimation of preoperative corneal astigmatism was statistically significant. Of a total of 57 cases, the 50.88% decreased from Tn to Tn-1, and 10.53% decreased from Tn to Tn-2. In all cases, 5.26% increased from Tn to Tn+1. The mean postoperative astigmatism within the TA group was significantly lower than that in the KA group. CONCLUSION The accuracy of total corneal astigmatism calculations and the efficacy of toric IOL correction can be enhanced by measuring both the anterior and posterior corneal surfaces using a Pentacam rotating Scheimpflug camera.
Collapse
Affiliation(s)
- Bin Zhang
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| | - Jing-Xue Ma
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| | - Dan-Yan Liu
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| | - Cong-Rong Guo
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| | - Ying-Hua Du
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| | - Xiu-Jin Guo
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| | - Yue-Xian Cui
- Department of Ophthalmology, the Second Hospital of Hebei Medical University, Shijiazhuang 050000, Hebei Province, China
| |
Collapse
|
42
|
Yaguchi Y, Negishi K, Saiki M, Torii H, Tsubota K. Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy. Jpn J Ophthalmol 2016; 60:365-72. [PMID: 27277426 DOI: 10.1007/s10384-016-0452-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2015] [Accepted: 03/23/2016] [Indexed: 10/21/2022]
Abstract
PURPOSE To compare the accuracy of several methods of intraocular lens (IOL) power calculations used for cataract surgery in eyes treated with phototherapeutic keratectomy (PTK) that results in changes in the anterior corneal surface and axial length; these results make power calculations less predictable. METHODS We evaluated the medical records of 23 eyes of 13 patients (mean age, 68.8 years; range 62-80 years) who underwent cataract surgery after PTK at Keio University Hospital, Tokyo, Japan. The prediction error, defined as the difference between the estimated postoperative spherical equivalent and the postoperative manifest refraction at the spectacle plane, was calculated using five formulas: SRK/T, Haigis-L, Shammas-PL, Camellin-Calossi, and OKULIX ray tracing software. We compared the median values of the arithmetic and absolute prediction errors among the five formulas. RESULTS The median arithmetic errors after cataract surgery for the five formulas were 0.70 D (diopter) (range -0.41 to 2.78), -0.96 D (range -2.14 to 0.81), -0.81 D (range -1.89 to 1.15), -0.04 D (range -1.35 to 1.47), and 0.68 D (range -0.61 to 2.50), respectively. CONCLUSION The Camellin-Calossi formula is a good option for calculating IOL powers in eyes that underwent PTK.
Collapse
Affiliation(s)
- Yukari Yaguchi
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Kazuno Negishi
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
| | - Megumi Saiki
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Hidemasa Torii
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| | - Kazuo Tsubota
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan
| |
Collapse
|
43
|
Veitía Rovirosa ZA, Bauza Fortunato Y, Pérez Candelaria EDLC, Méndez Duque de Estrada AM, Hormigó Puertas IF, Rodríguez Suárez B. Utilización de la fórmula de Haigis y el método de Maloney para el cálculo de pacientes vitrectomizados con cirugía refractiva corneal previa y catarata. REVISTA MEXICANA DE OFTALMOLOGÍA 2016. [DOI: 10.1016/j.mexoft.2015.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
44
|
Savini G, Hoffer KJ, Schiano-Lomoriello D, Ducoli P. Estimating the Preoperative Corneal Power With Scheimpflug Imaging in Eyes That Have Undergone Myopic LASIK. J Refract Surg 2016; 32:332-6. [DOI: 10.3928/1081597x-20160225-03] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Accepted: 01/15/2016] [Indexed: 11/20/2022]
|
45
|
Evaluation of Equivalent Keratometry Readings Obtained by Pentacam HR (High Resolution). PLoS One 2016; 11:e0150121. [PMID: 26950834 PMCID: PMC4780706 DOI: 10.1371/journal.pone.0150121] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2015] [Accepted: 02/09/2016] [Indexed: 11/20/2022] Open
Abstract
Purpose To assess the repeatability of Equivalent Keratometry Readings (EKRs) obtained by the Pentacam HR (high resolution) in untreated and post-LASIK eyes, and to compare them with the keratometry (K) values obtained by other algorithms. Methods In this prospective study, 100 untreated eyes and 71 post-LASIK eyes were included. In the untreated group, each eye received 3 consecutive scans using the Pentacam HR, and EKR values in all central corneal zone, the true net power (Knet) and the simulated K (SimK) were obtained for each scan. In the post-LASIK group, each eye received subjective refraction and 3 consecutive scans with the Pentacam HR preoperatively. During the 3-month post-surgery exam, the same examinations and the use of an IOLMaster were conducted for each eye. The EKRs in all zone, the Knet, the mean K (Km) by IOLMaster and the K values by clinical history method (KCHM) were obtained. The repeatability of the EKRs was assessed by the within-subject standard deviation (Sw), 2.77Sw, coefficient of variation (CVw) and intraclass correlation coefficient (ICC). The bonferroni corrected multiple comparisons were performed to analyze the differences among the EKRs and K values calculated by other algorithms within the 2 groups. The 95% limits of agreement (LoA) were calculated. Results The EKR values in all central corneal zone were repeatable in both the untreated group (Sw≦0.19 D, 2.77Sw≦0.52 D, CVw≦1%, ICC≧0.978) and the post-LASIK group (Sw≦0.22 D, 2.77Sw≦0.62 D, CVw≦1%, ICC≧0.980). In the untreated group, the EKR in 4mm zone was close to SimK (P = 1.000), and the 95% LoA was (-0.13 to 0.15 D). The difference between Knet and SimK was -1.30±0.13 D (95% LoA -1.55 to -1.55 D, P<0.001). In the post-LASIK group, all the EKRs were significantly higher than KCHM (all P<0.001). The differences between the EKR in 4mm zone and KCHM, the EKR in 7mm zone and KCHM, Knet and KCHM, Km and KCHM, SimK and Knet were 0.64±0.50 D (95% LoA, -0.33 to 1.62 D), 1.77±0.88 D (95% LoA, 0.04 to 3.51 D), -0.98±0.48 D (95% LoA, -1.92 to -0.04 D), 0.64±0.53 D (95% LoA, -0.40 to 1.68 D), and 1.73±0.20 D (95% LoA, 1.33 to 2.13 D), respectively. Conclusions The EKRs obtained by the Pentacam HR were repeatable in both untreated eyes and post-LASIK eyes. Compared to the total corneal power obtained by the clinical history method, the EKR values generally overestimated the total corneal power in post-LASIK eyes. So, further calibrations for the EKR values should be conducted, before they were used for the total corneal power assessment in post-LASIK eyes.
Collapse
|
46
|
Pan C, Hua Y, Huang J, Tan W, Lu W, Wang Q. Corneal Power Measurement With the Dual Scheimpflug-Placido Topographer After Myopic Excimer Laser Surgery. J Refract Surg 2016; 32:182-6. [DOI: 10.3928/1081597x-20160106-02] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2015] [Accepted: 11/24/2015] [Indexed: 11/20/2022]
|
47
|
Montes de Oca I, Gökce SE, Hallahan K, Wang L, Koch DD. IOL Calculations in Short, Long, and Postrefractive Eyes. Int Ophthalmol Clin 2016; 56:49-70. [PMID: 27257722 DOI: 10.1097/iio.0000000000000119] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
48
|
Chen X, Yuan F, Wu L. Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes. J Cataract Refract Surg 2016; 42:163-70. [DOI: 10.1016/j.jcrs.2015.12.005] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2015] [Revised: 08/06/2015] [Accepted: 08/11/2015] [Indexed: 10/22/2022]
|
49
|
Manning S, Barry P, Henry Y, Rosen P, Stenevi U, Lundström M. Cataract surgery outcomes in corneal refractive surgery eyes. J Cataract Refract Surg 2015; 41:2358-65. [DOI: 10.1016/j.jcrs.2015.04.034] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2015] [Revised: 03/29/2015] [Accepted: 04/18/2015] [Indexed: 11/24/2022]
|
50
|
Comparison of Newer Intraocular Lens Power Calculation Methods for Eyes after Corneal Refractive Surgery. Ophthalmology 2015; 122:2443-9. [PMID: 26459996 DOI: 10.1016/j.ophtha.2015.08.037] [Citation(s) in RCA: 94] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2015] [Revised: 08/24/2015] [Accepted: 08/25/2015] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To compare the newer formulae, the optical coherence tomography (OCT)-based intraocular lens (IOL) power formula (OCT formula) and the Barrett True-K formula (True-K), with the methods on the American Society of Cataract and Refractive Surgery (ASCRS) calculator in eyes with previous myopic LASIK/photorefractive keratectomy (PRK). DESIGN Prospective case series. PARTICIPANTS A total of 104 eyes of 80 patients who had previous myopic LASIK/PRK and subsequent cataract surgery and IOL implantation. METHODS By using the actual refraction after cataract surgery as target refraction, predicted IOL power for each method was calculated. The IOL prediction error (PE) was obtained by subtracting the predicted IOL power from the power of the IOL implanted. MAIN OUTCOME MEASURES Arithmetic IOL PEs, variances of mean arithmetic IOL PE, median refractive PE, and percent of eyes within 0.5 diopters (D) and 1.0 D of refractive PE. RESULTS Optical coherence tomography produced smaller variance of IOL PE than did Wang-Koch-Maloney (WKM) and Shammas (P < 0.05). With the OCT, True-K No History, WKM, Shammas, Haigis-L, and Average of these 5 formulas, the median refractive PEs were 0.35 D, 0.42 D, 0.51 D, 0.48 D, 0.39 D, and 0.35 D, respectively, the percentage of eyes within 0.5 D of refractive PE were 68.3%, 58.7%, 50.0%, 52.9%, 55.8%, and 67.3%, respectively, and the percentage of eyes within 1.0 D of refractive PE were 92.3%, 90.4%, 86.9%, 88.5%, 90.4%, and 94.2%, respectively. The OCT formula had smaller refractive PE compared with the WKM and Shammas, and the Average approach produced significantly smaller refractive PE than all methods except OCT (all P < 0.05). CONCLUSIONS The OCT and True-K No History are promising formulas. The ASCRS IOL calculator has been updated to include the OCT and Barrett True K formulas. TRIAL REGISTRATION Intraocular Lens Power Calculation After Laser Refractive Surgery Based on Optical Coherence Tomography (OCT IOL); Identifier: NCT00532051; www.ClinicalTrials.gov.
Collapse
|