1
|
Sola-Martínez RA, Zeng J, Awchi M, Gisler A, Arnold K, Singh KD, Frey U, Díaz MC, de Diego Puente T, Sinues P. Preservation of exhaled breath samples for analysis by off-line SESI-HRMS: proof-of-concept study. J Breath Res 2023; 18:011002. [PMID: 38029449 DOI: 10.1088/1752-7163/ad10e1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 11/29/2023] [Indexed: 12/01/2023]
Abstract
Secondary electrospray ionization-high resolution mass spectrometry (SESI-HRMS) is an established technique in the field of breath analysis characterized by its short analysis time, as well as high levels of sensitivity and selectivity. Traditionally, SESI-HRMS has been used for real-time breath analysis, which requires subjects to be at the location of the analytical platform. Therefore, it limits the possibilities for an introduction of this methodology in day-to-day clinical practice. However, recent methodological developments have shown feasibility on the remote sampling of exhaled breath in Nalophan® bags prior to measurement using SESI-HRMS. To further explore the range of applications of this method, we conducted a proof-of-concept study to assess the impact of the storage time of exhaled breath in Nalophan® bags at different temperatures (room temperature and dry ice) on the relative intensities of the compounds. In addition, we performed a detailed study of the storage effect of 27 aldehydes related to oxidative stress. After 2 h of storage, the mean of intensity of allm/zsignals relative to the samples analyzed without prior storage remained above 80% at both room temperature and dry ice. For the 27 aldehydes, the mean relative intensity losses were lower than 20% at 24 h of storage, remaining practically stable since the first hour of storage following sample collection. Furthermore, the mean relative intensity of most aldehydes in samples stored at room temperature was higher than those stored in dry ice, which could be related to water vapor condensation issues. These findings indicate that the exhaled breath samples could be preserved for hours with a low percentage of mean relative intensity loss, thereby allowing more flexibility in the logistics of off-line SESI-HRMS studies.
Collapse
Affiliation(s)
- Rosa A Sola-Martínez
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain
| | - Jiafa Zeng
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Mo Awchi
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Amanda Gisler
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
| | - Kim Arnold
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Kapil Dev Singh
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Urs Frey
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
- Pediatric Respiratory Medicine, Department of Pediatrics, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| | - Manuel Cánovas Díaz
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain
| | - Teresa de Diego Puente
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain
| | - Pablo Sinues
- University of Basel Children's Hospital (UKBB), Basel, Switzerland
- Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland
| |
Collapse
|
2
|
Walsh CM, Fadel MG, Jamel SH, Hanna GB. Breath Testing in the Surgical Setting: Applications, Challenges, and Future Perspectives. Eur Surg Res 2023; 64:315-322. [PMID: 37311421 PMCID: PMC10614239 DOI: 10.1159/000531504] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Accepted: 06/05/2023] [Indexed: 06/15/2023]
Abstract
BACKGROUND The potential for exhaled breath to be a valuable diagnostic tool is often overlooked as it can be difficult to imagine how a barely visible sample of breath could hold such a rich source of information about the state of our health. However, technological advances over the last 50 years have enabled us to detect volatile organic compounds (VOCs) present in exhaled breath, and this provides the key to understanding the wealth of information contained within these readily available samples. SUMMARY VOCs are produced as a by-product of metabolism; hence, changes in the underlying physiological processes will be reflected in the exact composition of VOCs in exhaled breath. It has been shown that characteristic changes occur in the breath VOC profile associated with certain diseases including cancer, which may enable the non-invasive detection of cancer at primary care level for patients with vague symptoms. The use of breath testing as a diagnostic tool has many advantages. It is non-invasive and quick, and the test is widely accepted by patients and clinicians. However, breath samples provide a snapshot of the VOCs present in a particular patient at a given point in time, so this can be heavily influenced by external factors such as diet, smoking, and the environment. These must all be accounted for when attempting to draw conclusions about disease status. This review focuses on the current applications for breath testing in the field of surgery, as well as discussing the challenges encountered with developing a breath test in a clinical environment. The future of breath testing in the surgical setting is also discussed, including the translation of breath research into clinical practice. KEY MESSAGES Analysis of VOCs in exhaled breath can identify the presence of underlying disease including cancer as well as other infectious or inflammatory conditions. Despite the patient factors, environmental factors, storage, and transport considerations that must be accounted for, breath testing demonstrates ideal characteristics for a triage test, being non-invasive, simple, and universally acceptable to patients and clinicians. Many novel biomarkers and diagnostic tests fail to translate into clinical practice because their potential clinical application does not align with the requirements and unmet needs of the healthcare sector. Non-invasive breath testing, however, has the great potential to revolutionise the early detection of diseases, such as cancer, in the surgical setting for patients with vague symptoms.
Collapse
Affiliation(s)
- Caoimhe M Walsh
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Michael G Fadel
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - Sara H Jamel
- Department of Surgery and Cancer, Imperial College London, London, UK
| | - George B Hanna
- Department of Surgery and Cancer, Imperial College London, London, UK
| |
Collapse
|
3
|
P H, Rangarajan M, Pandya HJ. Breath VOC analysis and machine learning approaches for disease screening: a review. J Breath Res 2023; 17. [PMID: 36634360 DOI: 10.1088/1752-7163/acb283] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Accepted: 01/12/2023] [Indexed: 01/14/2023]
Abstract
Early disease detection is often correlated with a reduction in mortality rate and improved prognosis. Currently, techniques like biopsy and imaging that are used to screen chronic diseases are invasive, costly or inaccessible to a large population. Thus, a non-invasive disease screening technology is the need of the hour. Existing non-invasive methods like gas chromatography-mass spectrometry, selected-ion flow-tube mass spectrometry, and proton transfer reaction-mass-spectrometry are expensive. These techniques necessitate experienced operators, making them unsuitable for a large population. Various non-invasive sources are available for disease detection, of which exhaled breath is preferred as it contains different volatile organic compounds (VOCs) that reflect the biochemical reactions in the human body. Disease screening by exhaled breath VOC analysis can revolutionize the healthcare industry. This review focuses on exhaled breath VOC biomarkers for screening various diseases with a particular emphasis on liver diseases and head and neck cancer as examples of diseases related to metabolic disorders and diseases unrelated to metabolic disorders, respectively. Single sensor and sensor array-based (Electronic Nose) approaches for exhaled breath VOC detection are briefly described, along with the machine learning techniques used for pattern recognition.
Collapse
Affiliation(s)
- Haripriya P
- Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore 560012, India
| | - Madhavan Rangarajan
- Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore 560012, India
| | - Hardik J Pandya
- Department of Electronic Systems Engineering, Indian Institute of Science, Bangalore 560012, India.,Centre for Product Design and Manufacturing, Indian Institute of Science, Bangalore 560012, India
| |
Collapse
|
4
|
Current Insights and Progress in the Clinical Management of Head and Neck Cancer. Cancers (Basel) 2022; 14:cancers14246079. [PMID: 36551565 PMCID: PMC9776832 DOI: 10.3390/cancers14246079] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2022] [Revised: 12/05/2022] [Accepted: 12/06/2022] [Indexed: 12/14/2022] Open
Abstract
Head and neck cancer (HNC), also known as the cancer that can affect the structures between the dura mater and the pleura, is the 6th most common type of cancer. This heterogeneous group of malignancies is usually treated with a combination of surgery and radio- and chemotherapy, depending on if the disease is localized or at an advanced stage. However, most HNC patients are diagnosed at an advanced stage, resulting in the death of half of these patients. Thus, the prognosis of advanced or recurrent/metastatic HNC, especially HNC squamous cell carcinoma (HNSCC), is notably poorer than the prognosis of patients diagnosed with localized HNC. This review explores the epidemiology and etiologic factors of HNC, the histopathology of this heterogeneous cancer, and the diagnosis methods and treatment approaches currently available. Moreover, special interest is given to the novel therapies used to treat HNC subtypes with worse prognosis, exploring immunotherapies and targeted/multi-targeted drugs undergoing clinical trials, as well as light-based therapies (i.e., photodynamic and photothermal therapies).
Collapse
|
5
|
Kwon IJ, Jung TY, Son Y, Kim B, Kim SM, Lee JH. Detection of volatile sulfur compounds (VSCs) in exhaled breath as a potential diagnostic method for oral squamous cell carcinoma. BMC Oral Health 2022; 22:268. [PMID: 35778718 PMCID: PMC9250215 DOI: 10.1186/s12903-022-02301-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2021] [Accepted: 06/09/2022] [Indexed: 12/24/2022] Open
Abstract
Background Oral squamous cell carcinoma causes a significant proportion of global cancer morbidity and mortality. The aim of this study is to investigate whether the exhaled breath test can be a new, non-invasive, and effective method for diagnosing oral squamous cell carcinoma. Methods A comparative analysis of exhaled breath between patients with oral squamous cell carcinoma (OSCC) and healthy controls (HC) was performed with the Twin Breasor II™, a simple gas chromatography system. Results Both hydrogen sulfide (H2S) and methyl mercaptan (Ch3SH) were significantly higher in the OSCC group than in the HC group. The total sulfur concentration was also higher in the OSCC group, but there was no significant difference in the ratio of Ch3SH to H2S between the two groups. Using logistic regression, we constructed a new variable with an area under the curve (AUC) of 0.740, 68.0% sensitivity, and 72.0% specificity. Conclusions Exhaled gas analysis via simple gas chromatography can potentially serve as an accessory non-invasive method for OSCC diagnosis. Supplementary Information The online version contains supplementary material available at 10.1186/s12903-022-02301-3.
Collapse
Affiliation(s)
- Ik-Jae Kwon
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehakro, Jongnogu, Seoul, 03080, Korea
| | - Tae-Young Jung
- Department of Oral and Maxillofacial Surgery, Busan Paik Hospital, Inje University, Bokji-ro 75, Busanjin-gu, Busan, 47392, Korea
| | - Youjeong Son
- Dental Life Science Research Institute/Innovation Research & Support Center for Dental Science, Seoul National University Dental Hospital, Seoul, 03080, Korea
| | - Bongju Kim
- Dental Life Science Research Institute/Innovation Research & Support Center for Dental Science, Seoul National University Dental Hospital, Seoul, 03080, Korea
| | - Soung-Min Kim
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehakro, Jongnogu, Seoul, 03080, Korea
| | - Jong-Ho Lee
- Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, 101 Daehakro, Jongnogu, Seoul, 03080, Korea. .,Dental Life Science Research Institute/Innovation Research & Support Center for Dental Science, Seoul National University Dental Hospital, Seoul, 03080, Korea.
| |
Collapse
|
6
|
Volatile Organic Compounds in the Early Diagnosis of Non-healing Surgical Wounds: A Systematic Review. World J Surg 2022; 46:1669-1677. [DOI: 10.1007/s00268-022-06548-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/13/2022] [Indexed: 11/27/2022]
|
7
|
Shlomo IB, Frankenthal H, Laor A, Greenhut AK. Detection of SARS-CoV-2 infection by exhaled breath spectral analysis: Introducing a ready-to-use point-of-care mass screening method. EClinicalMedicine 2022; 45:101308. [PMID: 35224472 PMCID: PMC8856887 DOI: 10.1016/j.eclinm.2022.101308] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/23/2022] [Accepted: 01/31/2022] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND The current SARS-CoV-2 pandemic created an urgent need for rapid, infection screening applied to large numbers of asymptomatic individuals. To date, nasal/throat swab polymerase chain reaction (PCR) is considered the "gold standard". However, this is inconducive to mass, point-of-care (POC) testing due to person discomfort during sampling and a prolonged result turnaround. Breath testing for disease specific organic compounds potentially offers a practical, rapid, non-invasive, POC solution. The study compares the Breath of Health, Ltd. (BOH) breath analysis system to PCR's ability to screen asymptomatic individuals for SARS-CoV-2 infection. The BOH system is mobile and combines Fourier-transform infrared (FTIR) spectroscopy with artificial intelligence (AI) to generate results within 2 min and 15 s. In contrast to prior SARS-CoV-2 breath analysis research, this study focuses on diagnosing SARS-CoV-2 via disease specific spectrometric profiles rather than through identifying the disease specific molecules. METHODS Asymptomatic emergency room patients with suspected SARS-CoV-2 exposure in two leading Israeli hospitals were selected between February through April 2021. All were tested via nasal/throat-swab PCR and BOH breath analysis. In total, 297 patients were sampled (mean age 57·08 ± SD 18·86, 156 males, 139 females, 2 unknowns). Of these, 96 were PCR-positive (44 males, 50 females, 2 unknowns), 201 were PCR-negative (112 males, 89 females). One hundred samples were used for AI identification of SARS-CoV-2 distinguishing spectroscopic wave-number patterns and diagnostic algorithm creation. Algorithm validation was tested in 100 proof-of-concept samples (34 PCR-positive, 66 PCR-negative) by comparing PCR with AI algorithm-based breath-test results determined by a blinded medical expert. One hundred additional samples (12 true PCR-positive, 85 true PCR-negative, 3 confounder false PCR-positive [not included in the 297 total samples]) were evaluated by two blinded medical experts for further algorithm validation and inter-expert correlation. FINDINGS The BOH system identified three distinguishing wave numbers for SARS-CoV-2 infection. In the first phase, the single expert identified the first 100 samples correctly, yielding a 1:1 FTIR/AI:PCR correlation. The two-expert second-phase also yielded 1:1 FTIR/AI:PCR correlation for 97 non-confounders and null correlation for the 3 confounders. Inter-expert correlation was 1:1 for all results. In total, the FTIR/AI algorithm demonstrated 100% sensitivity and specificity for SARS-CoV-2 detection when compared with PCR. INTERPRETATION The SARS-CoV-2 method of breath analysis via FTIR with AI-based algorithm demonstrated high PCR correlation in screening for asymptomatic individuals. This is the first practical, rapid, POC breath analysis solution with such high PCR correlation in asymptomatic individuals. Further validation is required with a larger sample size. FUNDING Breath of Health Ltd, Rehovot, Israel provided study funding.
Collapse
Affiliation(s)
- Izhar Ben Shlomo
- Emergency Medicine Program, Zefat Academic College, Safed, Israel
| | - Hilel Frankenthal
- Emergency Medicine Program, Zefat Academic College, Safed, Israel
- Pediatric Intensive Care Unit, Rebecca Sieff Hospital, Safed, Israel
| | - Arie Laor
- Breath of Health Ltd., Rehovot, Israel
| | - Ayala Kobo Greenhut
- Emergency Medicine Program, Zefat Academic College, Safed, Israel
- Corresponding author at: Emergency Medicine Program, Zefat Academic College, Ider 42, Haifa, Safed, Israel
| |
Collapse
|
8
|
Dima AC, Balaban DV, Dima A. Diagnostic Application of Volatile Organic Compounds as Potential Biomarkers for Detecting Digestive Neoplasia: A Systematic Review. Diagnostics (Basel) 2021; 11:diagnostics11122317. [PMID: 34943554 PMCID: PMC8700395 DOI: 10.3390/diagnostics11122317] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 11/30/2021] [Accepted: 12/03/2021] [Indexed: 02/07/2023] Open
Abstract
Volatile organic compounds (VOCs) are part of the exhaled breath that were proposed as non-invasive breath biomarkers via different human discharge products like saliva, breath, urine, blood, or tissues. Particularly, due to the non-invasive approach, VOCs were considered as potential biomarkers for non-invasive early cancer detection. We herein aimed to review the data over VOCs utility in digestive neoplasia as early diagnosis or monitoring biomarkers. A systematic literature search was done using MEDLINE via PubMed, Cochrane Library, and Thomson Reuters' Web of Science Core Collection. We identified sixteen articles that were included in the final analysis. Based on the current knowledge, we cannot identify a single VOC as a specific non-invasive biomarker for digestive neoplasia. Several combinations of up to twelve VOCs seem promising for accurately detecting some neoplasia types. A combination of different VOCs breath expression are promising tools for digestive neoplasia screening.
Collapse
Affiliation(s)
- Augustin Catalin Dima
- Department of General Surgery and Department of Gastroenterology, Dr. Carol Davila Central Military Emergency University Hospital, 010825 Bucharest, Romania;
- Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania
| | - Daniel Vasile Balaban
- Department of General Surgery and Department of Gastroenterology, Dr. Carol Davila Central Military Emergency University Hospital, 010825 Bucharest, Romania;
- Carol Davila University of Medicine and Pharmacy, 020021 Bucharest, Romania
- Correspondence:
| | - Alina Dima
- Department of Rheumatology, Colentina Clinical Hospital, 020125 Bucharest, Romania;
| |
Collapse
|
9
|
Dixit K, Fardindoost S, Ravishankara A, Tasnim N, Hoorfar M. Exhaled Breath Analysis for Diabetes Diagnosis and Monitoring: Relevance, Challenges and Possibilities. BIOSENSORS 2021; 11:476. [PMID: 34940233 PMCID: PMC8699302 DOI: 10.3390/bios11120476] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 11/18/2021] [Accepted: 11/20/2021] [Indexed: 05/15/2023]
Abstract
With the global population prevalence of diabetes surpassing 463 million cases in 2019 and diabetes leading to millions of deaths each year, there is a critical need for feasible, rapid, and non-invasive methodologies for continuous blood glucose monitoring in contrast to the current procedures that are either invasive, complicated, or expensive. Breath analysis is a viable methodology for non-invasive diabetes management owing to its potential for multiple disease diagnoses, the nominal requirement of sample processing, and immense sample accessibility; however, the development of functional commercial sensors is challenging due to the low concentration of volatile organic compounds (VOCs) present in exhaled breath and the confounding factors influencing the exhaled breath profile. Given the complexity of the topic and the skyrocketing spread of diabetes, a multifarious review of exhaled breath analysis for diabetes monitoring is essential to track the technological progress in the field and comprehend the obstacles in developing a breath analysis-based diabetes management system. In this review, we consolidate the relevance of exhaled breath analysis through a critical assessment of current technologies and recent advancements in sensing methods to address the shortcomings associated with blood glucose monitoring. We provide a detailed assessment of the intricacies involved in the development of non-invasive diabetes monitoring devices. In addition, we spotlight the need to consider breath biomarker clusters as opposed to standalone biomarkers for the clinical applicability of exhaled breath monitoring. We present potential VOC clusters suitable for diabetes management and highlight the recent buildout of breath sensing methodologies, focusing on novel sensing materials and transduction mechanisms. Finally, we portray a multifaceted comparison of exhaled breath analysis for diabetes monitoring and highlight remaining challenges on the path to realizing breath analysis as a non-invasive healthcare approach.
Collapse
Affiliation(s)
- Kaushiki Dixit
- Department of Electronics and Electrical Communication Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India;
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Somayeh Fardindoost
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Adithya Ravishankara
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
| | - Nishat Tasnim
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
- Faculty of Engineering and Computer Science, University of Victoria, Victoria, BC V8W 2Y2, Canada
| | - Mina Hoorfar
- School of Engineering, University of British Columbia, Kelowna, BC V1V 1V7, Canada; (S.F.); (A.R.); (N.T.)
- Faculty of Engineering and Computer Science, University of Victoria, Victoria, BC V8W 2Y2, Canada
| |
Collapse
|
10
|
Gouzerh F, Bessière JM, Ujvari B, Thomas F, Dujon AM, Dormont L. Odors and cancer: Current status and future directions. Biochim Biophys Acta Rev Cancer 2021; 1877:188644. [PMID: 34737023 DOI: 10.1016/j.bbcan.2021.188644] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Revised: 10/22/2021] [Accepted: 10/23/2021] [Indexed: 02/07/2023]
Abstract
Cancer is the second leading cause of death in the world. Because tumors detected at early stages are easier to treat, the search for biomarkers-especially non-invasive ones-that allow early detection of malignancies remains a central goal to reduce cancer mortality. Cancer, like other pathologies, often alters body odors, and much has been done by scientists over the last few decades to assess the value of volatile organic compounds (VOCs) as signatures of cancers. We present here a quantitative review of 208 studies carried out between 1984 and 2020 that explore VOCs as potential biomarkers of cancers. We analyzed the main findings of these studies, listing and classifying VOCs related to different cancer types while considering both sampling methods and analysis techniques. Considering this synthesis, we discuss several of the challenges and the most promising prospects of this research direction in the war against cancer.
Collapse
Affiliation(s)
- Flora Gouzerh
- CREEC/CANECEV (CREES), Montpellier, France; MIVEGEC, Université de Montpellier, CNRS, IRD, Montpellier, France; CEFE, Univ Montpellier, CNRS, EPHE, IRD, Univ Paul Valéry Montpellier 3, Montpellier, France.
| | - Jean-Marie Bessière
- Ecole Nationale de Chimie de Montpellier, Laboratoire de Chimie Appliquée, Montpellier, France
| | - Beata Ujvari
- Deakin University, School of Life and Environmental Sciences, Centre for Integrative Ecology, Waurn Ponds, Vic 3216, Australia
| | - Frédéric Thomas
- CREEC/CANECEV (CREES), Montpellier, France; MIVEGEC, Université de Montpellier, CNRS, IRD, Montpellier, France
| | - Antoine M Dujon
- CREEC/CANECEV (CREES), Montpellier, France; MIVEGEC, Université de Montpellier, CNRS, IRD, Montpellier, France; Deakin University, School of Life and Environmental Sciences, Centre for Integrative Ecology, Waurn Ponds, Vic 3216, Australia
| | - Laurent Dormont
- CEFE, Univ Montpellier, CNRS, EPHE, IRD, Univ Paul Valéry Montpellier 3, Montpellier, France
| |
Collapse
|
11
|
Zhang J, Tian Y, Luo Z, Qian C, Li W, Duan Y. Breath volatile organic compound analysis: an emerging method for gastric cancer detection. J Breath Res 2021; 15. [PMID: 34610588 DOI: 10.1088/1752-7163/ac2cde] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Accepted: 10/05/2021] [Indexed: 12/14/2022]
Abstract
Gastric cancer is a common malignancy, being the fifth most frequently diagnosed cancer and the fourth leading cause of cancer-related deaths worldwide. Diagnosis of gastric cancer at the early stage is critical to effectively improve the survival rate. However, a substantial proportion of patients with gastric cancer in the early stages lack specific symptoms or are asymptomatic. Moreover, the imaging techniques currently used for gastric cancer screening, such as computed tomography and barium examination, are usually radioactive and have low sensitivity and specificity. Even though endoscopy has high accuracy for gastric cancer screening, its application is limited by the invasiveness of the technique. Breath analysis is an economic, effective, easy to perform, non-invasive detection method, and has no undesirable side effects on subjects. Extensive worldwide research has been conducted on breath volatile organic compounds (VOCs), which reveals its prospect as a potential method for gastric cancer detection. Many interesting results have been obtained and innovative methods have been introduced in this subject; hence, an extensive review would be beneficial. By providing a comprehensive list of breath VOCs identified by gastric cancer would promote further research in this field. This review summarizes the commonly used technologies for exhaled breath analysis, focusing on the application of analytical instruments in the detection of breath VOCs in gastric cancers, and the alterations in the profile of breath biomarkers in gastric cancer patients are discussed as well.
Collapse
Affiliation(s)
- Jing Zhang
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| | - Yonghui Tian
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| | - Zewei Luo
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| | - Cheng Qian
- Shaanxi Key Laboratory of Earth Surface System and Environmental Carrying Capacity, College of Urban and Environmental Sciences, Northwest University, Xi'an 710127, People's Republic of China
| | - Wenwen Li
- West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, People's Republic of China
| | - Yixiang Duan
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| |
Collapse
|
12
|
Surface composite and morphology tuning of tungsten oxide thin films for acetone gas sensing. Chem Phys Lett 2021. [DOI: 10.1016/j.cplett.2021.138659] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
13
|
Wang YL, Liu B, Pang YN, Liu J, Shi JL, Wan SP, He XD, Yuan J, Wu Q. Low-Cost Wearable Sensor Based on a D-Shaped Plastic Optical Fiber for Respiration Monitoring. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT 2021; 70:1-8. [PMID: 0 DOI: 10.1109/tim.2021.3075033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
|