1
|
Dot G, Licha R, Goussard F, Sansalone V. A new protocol to accurately track long-term orthodontic tooth movement and support patient-specific numerical modeling. J Biomech 2021; 129:110760. [PMID: 34628204 DOI: 10.1016/j.jbiomech.2021.110760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 09/15/2021] [Accepted: 09/18/2021] [Indexed: 10/20/2022]
Abstract
Numerical simulation of long-term orthodontic tooth movement based on Finite Element Analysis (FEA) could help clinicians to plan more efficient and mechanically sound treatments. However, most of FEA studies assume idealized loading conditions and lack experimental calibration or validation. The goal of this paper is to propose a novel clinical protocol to accurately track orthodontic tooth displacement in three-dimensions (3D) and provide 3D models that may support FEA. Our protocol uses an initial cone beam computed tomography (CBCT) scan and several intra-oral scans (IOS) to generate 3D models of the maxillary bone and teeth ready for use in FEA. The protocol was applied to monitor the canine retraction of a patient during seven months. A second CBCT scan was performed at the end of the study for validation purposes. In order to ease FEA, a frictionless and statically determinate lingual device for maxillary canine retraction was designed. Numerical simulations were set up using the 3D models provided by our protocol to show the relevance of our proposal. Comparison of numerical and clinical results highlights the suitability of this protocol to support patient-specific FEA.
Collapse
Affiliation(s)
- Gauthier Dot
- Univ Paris Est Creteil, CNRS, MSME, F-94010, Creteil, France; Univ Gustave Eiffel, MSME, F-77474, Marne-la-Vallée, France; Service d'Odontologie, Hopital Pitie-Salpetriere, AP-HP, Universite de Paris, Paris, France
| | - Raphael Licha
- Univ Paris Est Creteil, CNRS, MSME, F-94010, Creteil, France; Univ Gustave Eiffel, MSME, F-77474, Marne-la-Vallée, France
| | - Florent Goussard
- CR2P, UMR 7207, Muséum national d'Histoire naturelle, CNRS, Sorbonne Université, 8 rue Buffon, CP38 75005, Paris, France
| | - Vittorio Sansalone
- Univ Paris Est Creteil, CNRS, MSME, F-94010, Creteil, France; Univ Gustave Eiffel, MSME, F-77474, Marne-la-Vallée, France.
| |
Collapse
|
2
|
Tsai MT, Huang HL, Yang SG, Su KC, Fuh LJ, Hsu JT. Biomechanical analysis of occlusal modes on the periodontal ligament while orthodontic force applied. Clin Oral Investig 2021; 25:5661-5670. [PMID: 33665683 DOI: 10.1007/s00784-021-03868-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 02/25/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The study objective was to investigate four common occlusal modes by using the finite element (FE) method and to conduct a biomechanical analysis of the periodontal ligament (PDL) and surrounding bone when orthodontic force is applied. MATERIALS AND METHODS A complete mandibular FE model including teeth and the PDL was established on the basis of cone-beam computed tomography images of an artificial mandible. In the FE model, the left and right mandibular first premolars were not modeled because both canines required distal movement. In addition, four occlusal modes were simulated: incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), and right group function (RGF). The effects of these four occlusal modes on the von Mises stress and strain of the canine PDLs and bone were analyzed. RESULTS Occlusal mode strongly influenced the distribution and value of von Mises strain in the canine PDLs. The maximum von Mises strain values on the canine PDLs were 0.396, 1.811, 0.398, and 1.121 for INC, ICP, RMOL, and RGF, respectively. The four occlusal modes had smaller effects on strain distribution in the cortical bone, cancellous bone, and miniscrews. CONCLUSION Occlusal mode strongly influenced von Mises strain on the canine PDLs when orthodontic force was applied. CLINICAL RELEVANCE When an FE model is used to analyze the biomechanical behavior of orthodontic treatments, the effect of muscle forces caused by occlusion must be considered.
Collapse
Affiliation(s)
- Ming-Tzu Tsai
- Department of Biomedical Engineering, Hungkuang University, Taichung, 433, Taiwan
| | - Heng-Li Huang
- School of Dentistry, College of Medicine, China Medical University, Taichung, 404, Taiwan
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung, 413, Taiwan
| | - Shih-Guang Yang
- Master Program for Biomedical Engineering, China Medical University, Taichung, 404, Taiwan
| | - Kuo-Chih Su
- Department of Biomedical Engineering, Hungkuang University, Taichung, 433, Taiwan
- Department of Medical Research, Taichung Veterans General Hospital, Taichung, 407, Taiwan
| | - Lih-Jyh Fuh
- School of Dentistry, College of Medicine, China Medical University, Taichung, 404, Taiwan
- Department of Dentistry, China Medical University and Hospital, Taichung, 404, Taiwan
| | - Jui-Ting Hsu
- School of Dentistry, College of Medicine, China Medical University, Taichung, 404, Taiwan.
- Department of Bioinformatics and Medical Engineering, Asia University, Taichung, 413, Taiwan.
- School of Dentistry, College of Dentistry, China Medical University, 91 Hsueh-Shih Road, Taichung, 40402, Taiwan.
| |
Collapse
|
3
|
Mandible Integrity and Material Properties of the Periodontal Ligament during Orthodontic Tooth Movement: A Finite-Element Study. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10082980] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We used the finite-element method (FEM) to investigate the effects of jawbone model integrity and the material properties of the periodontal ligament (PDL) on orthodontic tooth movement. Medical imaging software and computer-aided design software were used to create finite-element models of a partial and complete mandibles based on dental cone beam computed tomography images of the human skull. Additionally, we exerted an orthodontic force on the canine crown in the direction of an orthodontic miniscrew under a lower molar root to compare the von Mises strain on the canine PDL in three models: a partial mandible model under orthodontic force (Model 1), a complete mandible model under orthodontic force (Model 2), and a complete mandible model under orthodontic force with clench occlusion in the intercuspal position (ICP; Model 3). Additionally, in the complete mandible model under orthodontic force with ICP occlusion, we analyzed the effects of a PDL with a low (Model 4), moderate (Model 5), and high (Model 6) linear elastic modulus and a PDL a bilinear elastic modulus (Model 7). The simulation results for mandible integrity indicated that the maximum von Mises strains on the canine PDL for Models 1, 2, and 3 were 0.461, 0.394, and 1.811, respectively. Moreover, for the models with different PDL material properties, the maximum von Mises strains on the canine PDLs for Models 4, 5, 6, and 7 were 6.047, 2.594, 0.887, and 1.811, respectively. When the FEM was used to evaluate tooth movement caused by orthodontic force, the transformation of a complete mandible model into a partial mandible model or alteration of the elastic modulus of the PDL influenced the biomechanical responses of the PDL. Additionally, the incorporation of daily ICP occlusion resulted in a larger effect.
Collapse
|
4
|
Baghdadi D, Reimann S, Keilig L, Reichert C, Jäger A, Bourauel C. Biomechanical analysis of initial incisor crowding alignment in the periodontally reduced mandible using the finite element method. J Orofac Orthop 2019; 80:184-193. [PMID: 31139844 DOI: 10.1007/s00056-019-00179-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 04/11/2019] [Indexed: 12/20/2022]
Abstract
AIMS To reduce remaining plaque niches due to dental malocclusion after periodontal treatment and to avoid reinflammation of periodontitis, severe anterior crowding can be treated orthodontically. The treatment indication is motivated by aesthetic and functional needs. In this study the biomechanical behaviour of crowded lower front teeth in reduced periodontium is analysed. METHODS Using the finite element (FE) method, a model of the mandible was constructed with an anterior crowding of 4 mm and a vertical bone loss of 4 mm in the front tooth area. A 0.3 mm (0.012″) round superelastic nickel titanium (NiTi) arch wire was fitted to an ideal positioned teeth set-up and was inserted into the brackets of teeth 34 to 44 in the crowded model. The premolars were used as the anchorage unit. Material parameters were adopted from previous investigations, including bone (homogenous, isotropic, E = 2 GPa), teeth (E = 20 GPa) and healthy periodontal ligament (PDL, bilinear elastic; E1 = 0.05 MPa; E2 = 0.2 MPa; ε12 = 7%). All simulations were compared to simulations with a physiological periodontal model to assess the effect of bone loss at teeth 42 to 32. Additionally, the influence of three arch wire materials (nonsuperelastic NiTi, superelastic NiTi and stainless steel) were analysed in a reduced model, including only brackets in position of the crowded front teeth, wire and ligatures. Wire force levels and stresses were determined to assess the influence of material variation. RESULTS Initial tooth mobility is increased by a factor of 2.5 in case of a moderate periodontal defect. Front teeth with reduced attachment display increased strains in the periodontal ligament up to a factor of 2. Forces in the model with reduced periodontium were decreased by a factor of 2. Comparing different aligning arch wires, stainless steel appears to have the highest force and stress levels. Force levels of this alloy were 7.5 times higher than with the superelastic NiTi wire. Force levels of nonsuperelastic NiTi appeared to be 1.8 times higher than superelastic NiTi. Calculated stresses with stainless steel were 5 times higher than with the nonsuperelastic NiTi and 10 times higher than with superelastic NiTi. CONCLUSION Periodontally reduced incisors 42 to 32 are associated with an increased load on periodontal tissue and increased level of tooth mobility during fixed orthodontic treatment. This has to be considered by reducing orthodontic force levels and by selecting mechanics that reduce the load to the tissue.
Collapse
Affiliation(s)
- Dorna Baghdadi
- Oralmedizinische Technologie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Welschnonnenstraße 17, 53111, Bonn, Germany.
| | - Susanne Reimann
- Oralmedizinische Technologie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Welschnonnenstraße 17, 53111, Bonn, Germany.,Hochschule Bremerhaven, Bremerhaven, Germany
| | - Ludger Keilig
- Oralmedizinische Technologie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Welschnonnenstraße 17, 53111, Bonn, Germany.,Abteilung für Zahnärztliche Prothetik, Propädeutik und Werkstoffwissenschaften, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany
| | - Christoph Reichert
- Poliklinik für Kieferorthopädie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany
| | - Andreas Jäger
- Poliklinik für Kieferorthopädie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Bonn, Germany
| | - Christoph Bourauel
- Oralmedizinische Technologie, Universitätsklinikum Bonn, Rheinische Friedrich-Wilhelms-Universität Bonn, Welschnonnenstraße 17, 53111, Bonn, Germany
| |
Collapse
|
5
|
Cai Y. A three-dimensional finite element analysis of the effect of archwire characteristics on the self-ligating orthodontic tooth movement of the canine. Technol Health Care 2019; 27:195-204. [PMID: 31045539 PMCID: PMC6598007 DOI: 10.3233/thc-199019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
Abstract
BACKGROUND: In orthodontics, the tooth movement is a biologic reaction to applied force systems, brackets, archwires, and periodontium tissue. OBJECTIVE: To investigate the effects of the various archwire characteristics like the friction coebetween bracket and archwire, the cross-section shape, and the cross-section dimension, on the displacement and the periodontal ligament (PDL) stresses of canine’s movement in a self-ligating treatment using the finite element (FE) analysis method. METHODS: Models of teeth and their supporting tissues, brackets and archwires were constructed. Ten kinds of archwires were used for the simulation. RESULTS: Considering the translation movement, the maximum displacement, highest stress, and Rcr increased with an increase in the cross-section area. The maximum displacement and highest stress increased with an increase in the friction coefficient. The Rcr values increased with an increase in the friction coefficient in the round archwires, while decreased with an increase in the rectangular archwires. However, these change tends were different in rotation and inclination movement. CONCLUSION: The archwire characteristics (round archwire, rectangular archwire, cross-section area, and friction coefficient) exhibited different effects on the tooth translation, rotation, and inclination. Our results can assist in the improvement of the self-ligating orthodontic treatment.
Collapse
|