1
|
Motahari-Nezhad H, Al-Abdulkarim H, Fgaier M, Abid MM, Péntek M, Gulácsi L, Zrubka Z. Digital Biomarker-Based Interventions: Systematic Review of Systematic Reviews. J Med Internet Res 2022; 24:e41042. [PMID: 36542427 PMCID: PMC9813819 DOI: 10.2196/41042] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 09/22/2022] [Accepted: 10/07/2022] [Indexed: 11/07/2022] Open
Abstract
BACKGROUND The introduction of new medical technologies such as sensors has accelerated the process of collecting patient data for relevant clinical decisions, which has led to the introduction of a new technology known as digital biomarkers. OBJECTIVE This study aims to assess the methodological quality and quality of evidence from meta-analyses of digital biomarker-based interventions. METHODS This study follows the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guideline for reporting systematic reviews, including original English publications of systematic reviews reporting meta-analyses of clinical outcomes (efficacy and safety endpoints) of digital biomarker-based interventions compared with alternative interventions without digital biomarkers. Imaging or other technologies that do not measure objective physiological or behavioral data were excluded from this study. A literature search of PubMed and the Cochrane Library was conducted, limited to 2019-2020. The quality of the methodology and evidence synthesis of the meta-analyses were assessed using AMSTAR-2 (A Measurement Tool to Assess Systematic Reviews 2) and GRADE (Grading of Recommendations, Assessment, Development, and Evaluations), respectively. This study was funded by the National Research, Development and Innovation Fund of Hungary. RESULTS A total of 25 studies with 91 reported outcomes were included in the final analysis; 1 (4%), 1 (4%), and 23 (92%) studies had high, low, and critically low methodologic quality, respectively. As many as 6 clinical outcomes (7%) had high-quality evidence and 80 outcomes (88%) had moderate-quality evidence; 5 outcomes (5%) were rated with a low level of certainty, mainly due to risk of bias (85/91, 93%), inconsistency (27/91, 30%), and imprecision (27/91, 30%). There is high-quality evidence of improvements in mortality, transplant risk, cardiac arrhythmia detection, and stroke incidence with cardiac devices, albeit with low reporting quality. High-quality reviews of pedometers reported moderate-quality evidence, including effects on physical activity and BMI. No reports with high-quality evidence and high methodological quality were found. CONCLUSIONS Researchers in this field should consider the AMSTAR-2 criteria and GRADE to produce high-quality studies in the future. In addition, patients, clinicians, and policymakers are advised to consider the results of this study before making clinical decisions regarding digital biomarkers to be informed of the degree of certainty of the various interventions investigated in this study. The results of this study should be considered with its limitations, such as the narrow time frame. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID) RR2-10.2196/28204.
Collapse
Affiliation(s)
- Hossein Motahari-Nezhad
- Health Economics Research Center, University Research and Innovation Center, Óbuda University, Budapest, Hungary
- Doctoral School of Business and Management, Corvinus University of Budapest, Budapest, Hungary
| | - Hana Al-Abdulkarim
- Doctoral School of Applied Informatics and Applied Mathematics, Óbuda University, Budapest, Hungary
- Drug Policy and Economic Center, National Guard Health Affairs, King Abdullah International Medical Research Center, Riyadh, Saudi Arabia
| | - Meriem Fgaier
- Doctoral School of Applied Informatics and Applied Mathematics, Óbuda University, Budapest, Hungary
| | - Mohamed Mahdi Abid
- Research Center of Epidemiology and Statistics, Université Sorbonne Paris Cité, Paris, France
| | - Márta Péntek
- Health Economics Research Center, University Research and Innovation Center, Óbuda University, Budapest, Hungary
| | - László Gulácsi
- Health Economics Research Center, University Research and Innovation Center, Óbuda University, Budapest, Hungary
- Corvinus Institute for Advanced Studies, Corvinus University of Budapest, Budapest, Hungary
| | - Zsombor Zrubka
- Health Economics Research Center, University Research and Innovation Center, Óbuda University, Budapest, Hungary
- Corvinus Institute for Advanced Studies, Corvinus University of Budapest, Budapest, Hungary
| |
Collapse
|
2
|
Li J, Zhang Y, Gao X, Dou T, Li X. Accelerometer-based navigation vs. conventional techniques for total knee arthroplasty (TKA): a systematic review and meta-analysis of randomized controlled trials. ARTHROPLASTY 2022; 4:35. [PMID: 36050798 PMCID: PMC9438290 DOI: 10.1186/s42836-022-00135-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Accepted: 06/09/2022] [Indexed: 11/23/2022] Open
Abstract
Background The aim of the study was to determine whether accelerometer-based navigation (ABN) can improve radiological and functional outcomes during total knee arthroplasty (TKA) compared with conventional techniques (CONV). Method We comprehensively searched the PubMed, Embase, Web of Science, Cochrane Library, and Clinical Trials databases. Only randomized controlled trials were selected for meta-analysis and, ultimately, 10 studies were included. Results The 10 studies involved 1,125 knees, of which 573 were in the ABN group and 552 in the CONV group. The results demonstrated that ABN significantly reduced the number of outliers for mechanical alignment (MA) (RR: 0.38, 95% CI: 0.27 to 0.54, P < 0.00001, I2 = 45%), achieving more accurate MA (RR: –0.78, 95% CI: –0.93 to –0.62, P < 0.00001, I2 = 76%). The results revealed that there was no significant difference in duration of surgery between the ABN and CONV groups (MD: –0.2, 95% CI: –1.45 to 1.05, P = 0.75, I2 = 48%). There was less blood loss through the use of ABN (SMD: –0.49, 95% CI: –0.93 to –0.06, P = 0.03, I2 = 75%). However, ABN group didn’t show better knee function (SMD: 0.13, 95% CI: –0.07 to 0.33, P = 0.20, I2 = 0%), though the incidence of overall complications was significantly lower (RR: 0.69, 95% CI: 0.50 to 0.95, P = 0.02, I2 = 0%). Conclusions The present meta-analysis demonstrated that ABN was superior to CONV in restoring MA of the lower limb. In addition, ABN reduced the loss of blood and the duration of surgery was not prolonged. However, patient-reported outcome measurements (PROMs) were not improved.
Collapse
|
3
|
Accelerometer-based, hand-held navigation for improved knee alignment in total knee arthroplasty: An observational study. J Clin Orthop Trauma 2021; 24:101689. [PMID: 34840947 PMCID: PMC8605332 DOI: 10.1016/j.jcot.2021.101689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 11/01/2021] [Accepted: 11/02/2021] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Malalignment in total knee arthroplasty has been associated with poor implant longevity and clinical outcomes. The aim of this study was to investigate the accuracy of accelerometer-based navigation in restoring the mechanical axis. METHODS 106 primary total knee arthroplasties performed during February 2016 to September 2017 at a tertiary care centre in India were enrolled in this observational study. We noted the intra-op tourniquet time. Two separate blinded observers measured the preoperative mechanical axis and the post operative radiological results (mechanical axis, coronal and sagittal alignment of femoral and tibial components) and the mean value was taken as final data. Interclass correlation was done to look for variability between the two observers. RESULTS The mean pre operative mechanical axis was 13.74 ± 10.44. The mean tourniquet time was 53.14 ± 7.42 min 91.5% (96/106) knees were within ±3° of neutral mechanical axis with a mean of 1.00° ± 2.68°. The femoral and tibial components with coronal alignment within ±3° perpendicular to the mechanical axis were 93.39% (99/106) and 89.62% (95/106) respectively. In the sagittal plane 89.62% of the femoral components and 87.73% of the tibial components were within ±3° perpendicular to the axis of tibia. CONCLUSION The Accelerometer based portable navigation system effectively reduces the coronal and sagittal alignment outliers in total knee arthroplasty and has no role in rotational alignment of components.
Collapse
|
4
|
Shigemura T, Baba Y, Murata Y, Yamamoto Y, Shiratani Y, Hamano H, Wada Y. Is a portable accelerometer-based navigation system useful in total hip arthroplasty?: A systematic review and meta-analysis. Orthop Traumatol Surg Res 2021; 107:102742. [PMID: 33358026 DOI: 10.1016/j.otsr.2020.08.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 07/31/2020] [Accepted: 08/19/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND Precise implant alignment is a crucial prognostic factor for successful outcomes following total hip arthroplasty (THA). A portable accelerometer-based navigation (PN) device may achieve the same accuracy as that achieved by the computer-assisted navigation surgery technique, with the convenience of a conventional technique. Although the usefulness of PN in THA (PN-THA) has been reported, whether it is more accurate than performing THA with a conventional technique (CON-THA) remains controversial. The difference in surgical time between PN-THA and CON-THA is also unclear. Therefore, we conducted a systematic review and meta-analysis of studies comparing results of PN-THA with those of CON-THA. We focused on the following question: is PN-THA superior to CON-THA in terms of radiological parameters and surgical time? PATIENTS AND METHODS A literature search was conducted in PubMed, Web of Science, and Cochrane Library, to identify studies that met the following inclusion criteria: randomised controlled trials (RCT) or non-RCT, studies involving patients who underwent PN-THA and patients who underwent CON-THA, studies including data on radiological parameters and surgical outcomes. Author names, publication year, country, study design, surgical approach, demographic characteristics of the participants (diagnosis, gender, age, and body mass index), and surgical outcomes (the radiological parameters and the surgical time) were extracted. We calculated the mean differences (MDs) for continuous data with 95% confidence intervals (CIs) for each outcome. p<0.05 was considered significant. RESULTS Three studies were included in this meta-analysis. The meta-analysis showed that absolute deviation of the postoperative measured angles from the target position for the cup anteversion was significantly smaller in PN-THA than in CON-THA (MD=-1.70, 95% CI=-2.91 to -0.50, [p=0.005]). There was no significant difference in the absolute deviation of the postoperative measured angles from the target position for cup abduction between the groups (MD=-1.82, 95% CI=-4.32-0.67, [p=0.15]). The surgical time was significantly longer in PN-THA than in CON-THA (MD=8.58, 95% CI=4.05-13.10, [p=0.0002]). DISCUSSION This systematic review and meta-analysis of studies comparing the results of PN-THA with those of CON-THA showed that the PN-THA is advantageous for precise cup implantation compared to CON-THA, although PN-THA has a longer surgical time compared to CON-THA. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Tomonori Shigemura
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan.
| | - Yoshihiko Baba
- Department of English, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, Tokyo, 181-8611, Japan
| | - Yasuaki Murata
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan
| | - Yohei Yamamoto
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan
| | - Yuki Shiratani
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan
| | - Hiroyuki Hamano
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan
| | - Yuichi Wada
- Department of Orthopaedic Surgery, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan
| |
Collapse
|
5
|
Gao X, Sun Y, Chen ZH, Dou TX, Liang QW, Li X. Comparison of the accelerometer-based navigation system with conventional instruments for total knee arthroplasty: a propensity score-matched analysis. J Orthop Surg Res 2019; 14:223. [PMID: 31319875 PMCID: PMC6637591 DOI: 10.1186/s13018-019-1258-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 07/04/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The accelerometer-based navigation (ABN) system is an emerging navigation system for total knee arthroplasty (TKA). This study aimed to determine whether the ABN system could improve the accuracy of mechanical alignment, component positioning, and short-term clinical outcomes for TKA when compared to conventional instruments (CON). METHODS A total of 204 patients were selected and divided into two groups (CON: 135, ABN: 69) after applying the inclusion and exclusion criteria. Then, 1:1 propensity score matching was performed for age, gender, body mass index, hip-knee-ankle angle (HKA), Knee Society Score (KSS), Western Ontario and McMaster Universities (WOMAC) score, and follow-up times. A total of 82 consecutive patients (82 knees) underwent total knee arthroplasty using ABN (n = 41) or CON (n = 41) were enrolled in this study. The postoperative HKA, frontal femoral component (FFC) angle, frontal tibial component (FTC) angle, lateral femoral flexion (LFF) angle, and lateral tibial component (LTC) angle were compared between the two groups to evaluate mechanical alignment and component positioning. Additional clinical parameters, including haemoglobin reduction, the KSS, and the WOMAC score, were assessed at the final follow-up (the mean follow-up period was 20.9 months in the CON group and 21.2 months in the ABN group). RESULTS The ABN group had a significantly improved mean absolute deviation of HKA (P = 0.033), FFC (P = 0.004), FTC (P = 0.017), LFF (P = 0.023), and LTC (P = 0.031) compared to those of the CON group. The numbers of FFCs and LTCs within 3° were significantly different (P = 0.021, P = 0.023, respectively) between the two groups. However, no differences in the numbers of FTCs within 3° (P = 0.166) and LFF within 3° (P = 0.556) were found. The ABN group had a significantly higher KS function score (P = 0.032), and the pain and stiffness scores were significantly different (P = 0.034, P = 0.020, respectively) between the two groups. Moreover, the ABN system could reduce hidden blood loss postoperatively. However, no difference was found in the KS knee score and the total WOMAC score between the two groups. CONCLUSION This study demonstrates that ABN system improved TKA mechanical alignment and component positioning and decreased the hidden blood loss postoperatively compared to conventional instruments. However, no significant differences were found in short-term clinical outcomes between ABN and conventional instruments at the final follow-up. However, whether this system contributes to revision rates and long-term clinical outcomes requires further study.
Collapse
Affiliation(s)
- Xiang Gao
- Department of Orthopedics, The First Hospital of China Medical University, 155, Shenyang, 110000 Liaoning Province People’s Republic of China
| | - Yu Sun
- Department of Orthopedics, The First Hospital of China Medical University, 155, Shenyang, 110000 Liaoning Province People’s Republic of China
| | - Zhao-He Chen
- Department of Orthopedics, The First Hospital of China Medical University, 155, Shenyang, 110000 Liaoning Province People’s Republic of China
| | - Tian-Xu Dou
- Department of Orthopedics, The First Hospital of China Medical University, 155, Shenyang, 110000 Liaoning Province People’s Republic of China
| | - Qing-Wei Liang
- Department of Orthopedics, The First Hospital of China Medical University, 155, Shenyang, 110000 Liaoning Province People’s Republic of China
| | - Xu Li
- Department of Orthopedics, The First Hospital of China Medical University, 155, Shenyang, 110000 Liaoning Province People’s Republic of China
| |
Collapse
|