1
|
Roth BJ. The magnetocardiogram. BIOPHYSICS REVIEWS 2024; 5:021305. [PMID: 38827563 PMCID: PMC11139488 DOI: 10.1063/5.0201950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Accepted: 05/06/2024] [Indexed: 06/04/2024]
Abstract
The magnetic field produced by the heart's electrical activity is called the magnetocardiogram (MCG). The first 20 years of MCG research established most of the concepts, instrumentation, and computational algorithms in the field. Additional insights into fundamental mechanisms of biomagnetism were gained by studying isolated hearts or even isolated pieces of cardiac tissue. Much effort has gone into calculating the MCG using computer models, including solving the inverse problem of deducing the bioelectric sources from biomagnetic measurements. Recently, most magnetocardiographic research has focused on clinical applications, driven in part by new technologies to measure weak biomagnetic fields.
Collapse
Affiliation(s)
- Bradley J. Roth
- Department of Physics, Oakland University, Rochester, Michigan 48309, USA
| |
Collapse
|
2
|
Hwang M, Lee SJ, Lim CH, Shim EB, Lee HA. The three-dimensionality of the hiPSC-CM spheroid contributes to the variability of the field potential. Front Physiol 2023; 14:1123190. [PMID: 37025386 PMCID: PMC10070703 DOI: 10.3389/fphys.2023.1123190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 03/10/2023] [Indexed: 04/08/2023] Open
Abstract
Background: Field potential (FP) signals from human induced pluripotent stem cell-derived cardiomyocyte (hiPSC-CM) spheroid which are used for drug safety tests in the preclinical stage are different from action potential (AP) signals and require working knowledge of the multi-electrode array (MEA) system. In this study, we developed in silico three-dimensional (3-D) models of hiPSC-CM spheroids for the simulation of field potential measurement. We compared our model simulation results against in vitro experimental data under the effect of drugs E-4031 and nifedipine. Methods: In silico 3-D models of hiPSC-CM spheroids were constructed in spherical and discoidal shapes. Tetrahedral meshes were generated inside the models, and the propagation of the action potential in the model was obtained by numerically solving the monodomain reaction-diffusion equation. An electrical model of electrode was constructed and FPs were calculated using the extracellular potentials from the AP propagations. The effects of drugs were simulated by matching the simulation results with in vitro experimental data. Results: The simulated FPs from the 3-D models of hiPSC-CM spheroids exhibited highly variable shapes depending on the stimulation and measurement locations. The values of the IC50 of E-4031 and nifedipine calculated by matching the simulated FP durations with in vitro experimental data were in line with the experimentally measured ones reported in the literature. Conclusion: The 3-D in silico models of hiPSC-CM spheroids generated highly variable FPs similar to those observed in in vitro experiments. The in silico model has the potential to complement the interpretation of the FP signals obtained from in vitro experiments.
Collapse
Affiliation(s)
| | - Su-Jin Lee
- Department of Predictive Toxicology, Korea Institute of Toxicology, Daejeon, Republic of Korea
| | | | - Eun Bo Shim
- AI Medic, Inc., Seoul, Republic of Korea
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, Republic of Korea
- *Correspondence: Eun Bo Shim, ; Hyang-Ae Lee,
| | - Hyang-Ae Lee
- Department of Predictive Toxicology, Korea Institute of Toxicology, Daejeon, Republic of Korea
- *Correspondence: Eun Bo Shim, ; Hyang-Ae Lee,
| |
Collapse
|
3
|
Hwang M, Uhm JS, Park MC, Shim EB, Lee CJ, Oh J, Yu HT, Kim TH, Joung B, Pak HN, Kang SM, Lee MH. In silico screening method for non-responders to cardiac resynchronization therapy in patients with heart failure: a pilot study. INTERNATIONAL JOURNAL OF ARRHYTHMIA 2022. [DOI: 10.1186/s42444-021-00052-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
Cardiac resynchronization therapy (CRT) is an effective treatment option for patients with heart failure (HF) and left ventricular (LV) dyssynchrony. However, the problem of some patients not responding to CRT remains unresolved. This study aimed to propose a novel in silico method for CRT simulation.
Methods
Three-dimensional heart geometry was constructed from computed tomography images. The finite element method was used to elucidate the electric wave propagation in the heart. The electric excitation and mechanical contraction were coupled with vascular hemodynamics by the lumped parameter model. The model parameters for three-dimensional (3D) heart and vascular mechanics were estimated by matching computed variables with measured physiological parameters. CRT effects were simulated in a patient with HF and left bundle branch block (LBBB). LV end-diastolic (LVEDV) and end-systolic volumes (LVESV), LV ejection fraction (LVEF), and CRT responsiveness measured from the in silico simulation model were compared with those from clinical observation. A CRT responder was defined as absolute increase in LVEF ≥ 5% or relative increase in LVEF ≥ 15%.
Results
A 68-year-old female with nonischemic HF and LBBB was retrospectively included. The in silico CRT simulation modeling revealed that changes in LVEDV, LVESV, and LVEF by CRT were from 174 to 173 mL, 116 to 104 mL, and 33 to 40%, respectively. Absolute and relative ΔLVEF were 7% and 18%, respectively, signifying a CRT responder. In clinical observation, echocardiography showed that changes in LVEDV, LVESV, and LVEF by CRT were from 162 to 119 mL, 114 to 69 mL, and 29 to 42%, respectively. Absolute and relative ΔLVESV were 13% and 31%, respectively, also signifying a CRT responder. CRT responsiveness from the in silico CRT simulation model was concordant with that in the clinical observation.
Conclusion
This in silico CRT simulation method is a feasible technique to screen for CRT non-responders in patients with HF and LBBB.
Collapse
|
4
|
Hwang M, Han S, Park MC, Leem CH, Shim EB, Yim DS. Three-Dimensional Heart Model-Based Screening of Proarrhythmic Potential by in silico Simulation of Action Potential and Electrocardiograms. Front Physiol 2019; 10:1139. [PMID: 31551815 PMCID: PMC6738014 DOI: 10.3389/fphys.2019.01139] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Accepted: 08/20/2019] [Indexed: 12/19/2022] Open
Abstract
The proarrhythmic risk is a major concern in drug development. The Comprehensive in vitro Proarrhythmia Assay (CiPA) initiative has proposed the JTpeak interval on electrocardiograms (ECGs) and qNet, an in silico metric, as new biomarkers that may overcome the limitations of the hERG assay and QT interval. In this study, we simulated body-surface ECGs from patch-clamp data using realistic models of the ventricles and torso to explore their suitability as new in silico biomarkers for cardiac safety. We tested seven drugs in this study: dofetilide (high proarrhythmic risk), ranolazine, verapamil (QT increasing, but safe), bepridil, cisapride, mexiletine, and diltiazem. Human ventricular geometry was reconstructed from computed tomography (CT) images, and a Purkinje fiber network was mapped onto the endocardial surface. The electrical wave propagation in the ventricles was obtained by solving a reaction-diffusion equation using finite-element methods. The body-surface ECG data were calculated using a torso model that included the ventricles. The effects of the drugs were incorporated in the model by partly blocking the appropriate ion channels. The effects of the drugs on single-cell action potential (AP) were examined first, and three-dimensional (3D) body-surface ECG simulations were performed at free Cmax values of 1×, 5×, and 10×. In the single-cell and ECG simulations at 5× Cmax, dofetilide, but not verapamil or ranolazine, caused arrhythmia. However, the non-increasing JTpeak caused by verapamil and ranolazine that has been observed in humans was not reproduced in our simulation. Our results demonstrate the potential of 3D body-surface ECG simulation as a biomarker for evaluation of the proarrhythmic risk of candidate drugs.
Collapse
Affiliation(s)
| | - Seunghoon Han
- Department of Clinical Pharmacology and Therapeutics, Seoul St. Mary's Hospital, Seoul, South Korea.,Pharmacometrics Institute for Practical Education and Training (PIPET), College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Min Cheol Park
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Chae Hun Leem
- Department of Physiology, College of Medicine, University of Ulsan, Asan Medical Center, Seoul, South Korea
| | - Eun Bo Shim
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Dong-Seok Yim
- Department of Clinical Pharmacology and Therapeutics, Seoul St. Mary's Hospital, Seoul, South Korea.,Pharmacometrics Institute for Practical Education and Training (PIPET), College of Medicine, The Catholic University of Korea, Seoul, South Korea
| |
Collapse
|
5
|
Ryu AJ, Lee KE, Kwon SS, Shin ES, Shim EB. In silico evaluation of the acute occlusion effect of coronary artery on cardiac electrophysiology and the body surface potential map. THE KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY : OFFICIAL JOURNAL OF THE KOREAN PHYSIOLOGICAL SOCIETY AND THE KOREAN SOCIETY OF PHARMACOLOGY 2018; 23:71-79. [PMID: 30627012 PMCID: PMC6315095 DOI: 10.4196/kjpp.2019.23.1.71] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Revised: 11/21/2018] [Accepted: 12/01/2018] [Indexed: 11/15/2022]
Abstract
Body surface potential map, an electric potential distribution on the body torso surface, enables us to infer the electrical activities of the heart. Therefore, observing electric potential projected to the torso surface can be highly useful for diagnosing heart diseases such as coronary occlusion. The BSPM for the heart of a patient show a higher level of sensitivity than 12-lead ECG. Relevant research has been mostly based on clinical statistics obtained from patients, and, therefore, a simulation for a variety of pathological phenomena of the heart is required. In this study, by using computer simulation, a body surface potential map was implemented according to various occlusion locations (distal, mid, proximal occlusion) in the left anterior descending coronary artery. Electrophysiological characteristics of the body surface during the ST segment period were observed and analyzed based on an ST isointegral map. We developed an integrated system that takes into account the cellular to organ levels, and performed simulation regarding the electrophysiological phenomena of the heart that occur during the first 5 minutes (stage 1) and 10 minutes (stage 2) after commencement of coronary occlusion. Subsequently, we calculated the bipolar angle and amplitude of the ST isointegral map, and observed the correlation between the relevant characteristics and the location of coronary occlusion. In the result, in the ventricle model during the stage 1, a wider area of ischemia led to counterclockwise rotation of the bipolar angle; and, during the stage 2, the amplitude increased when the ischemia area exceeded a certain size.
Collapse
Affiliation(s)
| | - Kyung Eun Lee
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea
| | | | - Eun-Seok Shin
- Department of Cardiology, University of Ulsan College of Medicine, Ulsan 44033, Korea
| | - Eun Bo Shim
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon 24341, Korea
| |
Collapse
|
6
|
Hwang M, Park J, Lee YS, Park JH, Choi SH, Shim EB, Pak HN. Fibrillation Number Based on Wavelength and Critical Mass in Patients Who Underwent Radiofrequency Catheter Ablation for Atrial Fibrillation. IEEE Trans Biomed Eng 2015; 62:673-9. [DOI: 10.1109/tbme.2014.2363669] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
7
|
Clinical application of the fibrillation number in patients with an implantable cardioverter defibrillator. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2014; 116:33-9. [DOI: 10.1016/j.pbiomolbio.2014.09.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Revised: 09/05/2014] [Accepted: 09/07/2014] [Indexed: 11/21/2022]
|
8
|
Yun Y, Hwang M, Park JH, Shin H, Shim EB, Pak HN. The relationship among complex fractionated electrograms, wavebreak, phase singularity, and local dominant frequency in fibrillation wave-dynamics: a modeling comparison study. J Korean Med Sci 2014; 29:370-7. [PMID: 24616586 PMCID: PMC3945132 DOI: 10.3346/jkms.2014.29.3.370] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2013] [Accepted: 12/17/2013] [Indexed: 11/20/2022] Open
Abstract
Although complex fractionated electrogram (CFE) is known to be a target for catheter ablation of fibrillation, its physiological meaning in fibrillation wave-dynamics remains to be clarified. We evaluated the spatiotemporal relationships among the parameters of fibrillation wave-dynamics by simulation modeling. We generated maps of CFE-cycle length (CFE-CL), local dominant frequency (LDF), wave break (WB), and phase singularity (PS) of fibrillation in 2-dimensional homogeneous bidomain cardiac modeling (1,000 × 1,000 cells ten Tusscher model). We compared spatiotemporal correlations by dichotomizing each maps into 10 × 10 lattice zones. In spatial distribution, WB and PS showed excellent correlation (R = 0.963, P < 0.001). CFE-CL had weak correlations with WB (R = 0.288, P < 0.001), PS (R = 0.313, P < 0.001), and LDF (R = -0.411, P < 0.001). However, LDF did not show correlation with PS or WB. PSs were mostly distributed at the periphery of low CFE-CL area. Virtual ablation (5% of critical mass) of CFE-CL < 100 ms terminated fibrillation at 14.3 sec, and high LDF ablation (5% of critical mass) changed fibrillation to organized tachycardia, respectively. In homogeneous 2D fibrillation modeling, CFE-CL was weakly correlated with WB, PS, and LDF, spatiotemporally. PSs are mostly positioned at the periphery of low CFE-CL areas, and virtual ablation targeting low CFE-CL regions terminated fibrillation successfully.
Collapse
Affiliation(s)
- Yonghyeon Yun
- Department of Convergence Biomedical Engineering, Daelim University College, Anyang, Korea
| | - Minki Hwang
- Division of Cardiology, Yonsei University Health System, Seoul, Korea
| | - Jae Hyung Park
- Division of Cardiology, Yonsei University Health System, Seoul, Korea
| | - Hangsik Shin
- Department of Biomedical Engineering, Chonnam National University, Yeosu, Korea
| | - Eun Bo Shim
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, Korea
| | - Hui-Nam Pak
- Division of Cardiology, Yonsei University Health System, Seoul, Korea
| |
Collapse
|
9
|
Lim KM, Jeon JW, Gyeong MS, Hong SB, Ko BH, Bae SK, Shin KS, Shim EB. Patient-specific identification of optimal ubiquitous electrocardiogram (U-ECG) placement using a three-dimensional model of cardiac electrophysiology. IEEE Trans Biomed Eng 2012; 60:245-9. [PMID: 22893363 DOI: 10.1109/tbme.2012.2209648] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A bipolar mini-ECG for ubiquitous healthcare (U-ECG) has been introduced, and various studies using the U-ECG device are in progress. Because it uses two electrodes within a small torso surface area, the design of the U-ECG must be suitable for detecting ECG signals. Using a 3-D model of cardiac electrophysiology, we have developed a simulation method for identifying the optimal placement of U-ECG electrodes on the torso surface. We simulated the heart-torso model to obtain a body surface potential map and ECG waveforms, which were compared with the empirical data. Using this model, we determined the optimal placement of the two U-ECG electrodes, spaced 5 cm apart, for detecting the P, R, and T waves. The ECG data, obtained using the optimal U-ECG placement for a specific wave, showed a clear shape for the target wave, but equivocal shapes for the other waves. The present study provides an efficient simulation method to identify the optimal attachment position and direction of the U-ECG electrodes on the surface of the torso.
Collapse
Affiliation(s)
- Ki Moo Lim
- Department of Medical IT Convergence Engineering, Kumoh Institute of Technology, Gyungbuk 730-701, South Korea.
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Lim KM, Hong SB, Jeon JW, Gyung MS, Ko BH, Bae SK, Shin KS, Shim EB. Predicting the optimal position and direction of a ubiquitous ECG using a multi-scale model of cardiac electrophysiology. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:993-6. [PMID: 22254479 DOI: 10.1109/iembs.2011.6090230] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this study, we determined the optimal position and direction of a one-channel bipolar electrocardiogram (ECG), used ubiquitously in healthcare. To do this, we developed a three-dimensional (3D) electrophysiological model of the heart coupled with a torso model that can generate a virtual body surface potential map (BSPM). Finite element models of the atria and ventricles incorporated the electrophysiological dynamics of atrial and ventricular myocytes, respectively. The torso model, in which the electric wave pattern on the cardiac tissue is reflected onto the body surface, was implemented using a boundary element method. Using the model, we derived the optimal positions of two electrodes, 5 cm apart, of the bipolar ubiquitous ECG (U-ECG) for detecting the P, R, and T waves. This model can be used as a simulation tool to design U-ECG device for use for various arrhythmia and normal patients.
Collapse
Affiliation(s)
- Ki Moo Lim
- Department of Mechanical & Biomedical Engineering, Kangwon National University, Chuncheon, Ganwon-do, South Korea.
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Shim EB, Hong SB, Lim KM, Leem CH, Youn CH, Pak HN, Earm YE, Noble D. New index for categorising cardiac reentrant wave: in silico evaluation. IET Syst Biol 2011; 5:317-23. [PMID: 22010758 DOI: 10.1049/iet-syb.2011.0019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Based on the similarity between a reentrant wave in cardiac tissue and a vortex in fluid dynamics, the authors hypothesised that a new non-dimensional index, like the Reynolds number in fluid dynamics, may play a critical role in categorising reentrant wave dynamics. Therefore the goal of the present study is to devise a new index to characterise electric wave conduction in cardiac tissue and examined whether this index can be used as a biomarker for categorising the reentrant wave pattern in cardiac tissue. Similar to the procedure used to derive the Reynolds number in fluid dynamics, the authors used a non-dimensionalisation technique to obtain the new index. Its usefulness was verified using a two-dimensional simulation model of electrical wave propagation in cardiac tissue. The simulation results showed that electrical waves in cardiac tissue move into an unstable region when the index exceeds a threshold value.
Collapse
Affiliation(s)
- E B Shim
- Department of Mechanical & Biomedical Engineering, Kangwon National University, Republic of Korea.
| | | | | | | | | | | | | | | |
Collapse
|