1
|
Carlier B, Heymans SV, Nooijens S, Collado-Lara G, Toumia Y, Delombaerde L, Paradossi G, D’hooge J, Van Den Abeele K, Sterpin E, Himmelreich U. A Preliminary Investigation of Radiation-Sensitive Ultrasound Contrast Agents for Photon Dosimetry. Pharmaceuticals (Basel) 2024; 17:629. [PMID: 38794199 PMCID: PMC11125270 DOI: 10.3390/ph17050629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 04/28/2024] [Accepted: 04/30/2024] [Indexed: 05/26/2024] Open
Abstract
Radiotherapy treatment plans have become highly conformal, posing additional constraints on the accuracy of treatment delivery. Here, we explore the use of radiation-sensitive ultrasound contrast agents (superheated phase-change nanodroplets) as dosimetric radiation sensors. In a series of experiments, we irradiated perfluorobutane nanodroplets dispersed in gel phantoms at various temperatures and assessed the radiation-induced nanodroplet vaporization events using offline or online ultrasound imaging. At 25 °C and 37 °C, the nanodroplet response was only present at higher photon energies (≥10 MV) and limited to <2 vaporization events per cm2 per Gy. A strong response (~2000 vaporizations per cm2 per Gy) was observed at 65 °C, suggesting radiation-induced nucleation of the droplet core at a sufficiently high degree of superheat. These results emphasize the need for alternative nanodroplet formulations, with a more volatile perfluorocarbon core, to enable in vivo photon dosimetry. The current nanodroplet formulation carries potential as an innovative gel dosimeter if an appropriate gel matrix can be found to ensure reproducibility. Eventually, the proposed technology might unlock unprecedented temporal and spatial resolution in image-based dosimetry, thanks to the combination of high-frame-rate ultrasound imaging and the detection of individual vaporization events, thereby addressing some of the burning challenges of new radiotherapy innovations.
Collapse
Affiliation(s)
- Bram Carlier
- Department of Oncology, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (B.C.); (L.D.); (E.S.)
- Department of Imaging and Pathology, KU Leuven-University of Leuven, 3000 Leuven, Belgium
- Molecular Small Animal Imaging Center (MoSAIC), KU Leuven-University of Leuven, 3000 Leuven, Belgium
| | - Sophie V. Heymans
- Department of Physics, KU Leuven Campus Kortrijk—KULAK, Etienne Sabbelaan 53, 8500 Kortrijk, Belgium; (S.V.H.); (K.V.D.A.)
- Department of Cardiovascular Sciences, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (S.N.); (J.D.)
| | - Sjoerd Nooijens
- Department of Cardiovascular Sciences, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (S.N.); (J.D.)
| | - Gonzalo Collado-Lara
- Department of Cardiology, Erasmus MC University Medical Center, 3015 GD Rotterdam, The Netherlands;
| | - Yosra Toumia
- National Institute for Nuclear Physics, INFN Sezione di Roma Tor Vergata, 00133 Rome, Italy;
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Laurence Delombaerde
- Department of Oncology, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (B.C.); (L.D.); (E.S.)
- Department of Radiotherapy, UH Leuven, 3000 Leuven, Belgium
| | - Gaio Paradossi
- Department of Chemical Science and Technologies, University of Rome Tor Vergata, 00133 Rome, Italy;
| | - Jan D’hooge
- Department of Cardiovascular Sciences, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (S.N.); (J.D.)
| | - Koen Van Den Abeele
- Department of Physics, KU Leuven Campus Kortrijk—KULAK, Etienne Sabbelaan 53, 8500 Kortrijk, Belgium; (S.V.H.); (K.V.D.A.)
| | - Edmond Sterpin
- Department of Oncology, KU Leuven-University of Leuven, 3000 Leuven, Belgium; (B.C.); (L.D.); (E.S.)
- Particle Therapy Interuniversity Center Leuven—PARTICLE, 3000 Leuven, Belgium
| | - Uwe Himmelreich
- Department of Imaging and Pathology, KU Leuven-University of Leuven, 3000 Leuven, Belgium
- Molecular Small Animal Imaging Center (MoSAIC), KU Leuven-University of Leuven, 3000 Leuven, Belgium
| |
Collapse
|
2
|
Kirby J, Chester K. Automation to facilitate optimisation of breast radiotherapy treatments using EPID-based in vivodosimetry. Phys Med Biol 2024; 69:095018. [PMID: 38537296 DOI: 10.1088/1361-6560/ad387e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 03/26/2024] [Indexed: 04/25/2024]
Abstract
Objective. To use automation to facilitate the monitoring of each treatment fraction using an electronic portal imaging device (EPID) basedin vivodosimetry (IVD) system, allowing optimisation of breast radiotherapy delivery for individual patients and cohorts.Approach. A suite of in-house software was developed to reduce the number of manual interactions with the commercial IVD system, dosimetry check. An EPID specific pixel sensitivity map facilitated use of the EPID panel away from the central axis. Point dose difference and the change in standard deviation in dose were identified as useful dose metrics, with standard deviation used in preference to gamma in the presence of a systematic dose offset. Automated IVD was completed for 3261 fractions across 704 patients receiving breast radiotherapy.Main results. Multiple opportunities for treatment optimisation were identified for individual patients and across patient cohorts as a result of successful implementation of automated IVD. 5.1% of analysed fractions were out of tolerance with 27.1% of these considered true positives. True positive results were obtained on any fraction of treatment and if IVD had only been completed on the first fraction, 84.4% of true positive results would have been missed. This was made possible due to the automation that saved over 800 h of manual intervention and stored data in an accessible database.Significance. An improved EPID calibration to allow off-axis measurement maximises the number of patients eligible for IVD (36.8% of patients in this study). We also demonstrate the importance in selecting context-specific assessment metrics and how these can lead to a managable false positive rate. We have shown that the use of fully automated IVD facilitates use on every fraction of treatment. This leads to identification of areas for treatment improvement for both individuals and across a patient cohort, expanding the uses of IVD from simply gross error detection towards treatment optimisation.
Collapse
Affiliation(s)
- Joshua Kirby
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Freeman Hospital, United Kingdom
| | - Katherine Chester
- Northern Centre for Cancer Care, Newcastle upon Tyne Hospitals NHS Foundation Trust, Cumberland Infirmary, United Kingdom
| |
Collapse
|
3
|
Olaciregui-Ruiz I, Simões R, Jan-Jakob S. Deep learning-based tools to distinguish plan-specific from generic deviations in EPID-based in vivo dosimetry. Med Phys 2024; 51:854-869. [PMID: 38112213 DOI: 10.1002/mp.16895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 11/24/2023] [Accepted: 12/01/2023] [Indexed: 12/21/2023] Open
Abstract
BACKGROUND Dose distributions calculated with electronic portal imaging device (EPID)-based in vivo dosimetry (EIVD) differ from planned dose distributions due to generic and plan-specific deviations. Generic deviations are characteristic to a class of plans. Examples include limitations in EIVD dose reconstruction, inaccuracies in treatment planning system (TPS) calculations and systematic machine deviations. Plan-specific deviations have an unpredictable character. Examples include discrepancies between the patient model used for dose calculation and the patient position or anatomy during delivery, random machine deviations, and data transfer, human or software errors. During the inspection work performed with traditional γ-evaluation statistical methods: (i) generic deviations raise alerts that need to be inspected but that rarely lead to action as their root cause is usually understood and (ii) the detection of relevant plan-specific deviations may be hindered by the presence of generic deviations. PURPOSE To investigate whether deep learning-based tools can help in identifying γ-alerts raised by generic deviations and in improving the detectability of plan-specific deviations. METHODS A 3D U-Net was trained as an autoencoder to reconstruct underlying patterns of generic deviations in γ-distributions. The network was trained for four treatment disease sites differently affected by generic deviations: volumetric modulated arc therapy (VMAT) lung (no known deviations), VMAT prostate (TPS inaccuracies), VMAT head-and-neck (EIVD limitations) and intensity modulated radiation therapy (IMRT) breast (large EIVD limitations). The network was trained with virtual non-transit γ-distributions: 60 train/10 validation for the VMAT sites and 30 train/10 validation for IMRT breast. It was hypothesized that in vivo γ-distributions obtained in the presence of plan-specific deviations would differ from those seen during training. For each disease site, the sensitivity of γ-analysis and the network to detect (synthetically introduced) patient-related deviations was compared by receiver operator characteristic analysis. The investigated deviations were patient positioning errors, weight gain or loss, and tumor volume changes. The clinical relevance was illustrated qualitatively with 793 in vivo clinical cases (141 lung, 136 head-and-neck, 209 prostate and 307 breast). RESULTS Error detectability of patient-related deviations was better with the network than with γ-analysis. The average area under the curve values over all sites were 0.86 ± 0.12(1SD) and 0.69 ± 0.25(1SD), respectively. Regarding in vivo clinical results, the percentage of cases differently classified by γ-analysis and the network was 1%, 19%, 18% and 64% for lung, head-and-neck, prostate, and breast, respectively. In head-and-neck and breast cases, 45 γ-only alerts were examined, of which 43 were attributed to EPID dose reconstruction limitations. For prostate, all 15 investigated γ-only alerts were due to known TPS inaccuracies. All 59 investigated network alerts were explained by either patient-related deviations or EPID acquisition incidents. Some patient-related deviations detected by the network were not detected by γ-analysis. CONCLUSIONS Deep learning-based tools trained to reconstruct underlying patterns of generic deviations in γ-distributions can be used to (i) automatically identify false positives within the set of γ-alerts and (ii) improve the detection of plan-specific deviations, hence minimizing the likelihood of false negatives. The presented method provides clear additional value to the γ-alert management process for large scale EIVD systems.
Collapse
Affiliation(s)
- Igor Olaciregui-Ruiz
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Rita Simões
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Sonke Jan-Jakob
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Sánchez‐Artuñedo D, Pié‐Padró S, Hermida‐López M, Duch‐Guillén MA, Beltran‐Vilagrasa M. Validation of an in vivo transit dosimetry algorithm using Monte Carlo simulations and ionization chamber measurements. J Appl Clin Med Phys 2024; 25:e14187. [PMID: 37890864 PMCID: PMC10860462 DOI: 10.1002/acm2.14187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/14/2023] [Accepted: 10/11/2023] [Indexed: 10/29/2023] Open
Abstract
PURPOSE Transit dosimetry is a safety tool based on the transit images acquired during treatment. Forward-projection transit dosimetry software, as PerFRACTION, compares the transit images acquired with an expected image calculated from the DICOM plan, the CT, and the structure set. This work aims to validate PerFRACTION expected transit dose using PRIMO Monte Carlo simulations and ionization chamber measurements, and propose a methodology based on MPPG5a report. METHODS The validation process was divided into three groups of tests according to MPPG5a: basic dose validation, IMRT dose validation, and heterogeneity correction validation. For the basic dose validation, the fields used were the nine fields needed to calibrate PerFRACTION and three jaws-defined. For the IMRT dose validation, seven sweeping gaps fields, the MLC transmission and 29 IMRT fields from 10 breast treatment plans were measured. For the heterogeneity validation, the transit dose of these fields was studied using three phantoms: 10 , 30 , and a 3 cm cork slab placed between 10 cm of solid water. The PerFRACTION expected doses were compared with PRIMO Monte Carlo simulation results and ionization chamber measurements. RESULTS Using the 10 cm solid water phantom, for the basic validation fields, the root mean square (RMS) of the difference between PerFRACTION and PRIMO simulations was 0.6%. In the IMRT fields, the RMS of the difference was 1.2%. When comparing respect ionization chamber measurements, the RMS of the difference was 1.0% both for the basic and the IMRT validation. The average passing rate with a γ(2%/2 mm, TH = 20%) criterion between PRIMO dose distribution and PerFRACTION expected dose was 96.0% ± 5.8%. CONCLUSION We validated PerFRACTION calculated transit dose with PRIMO Monte Carlo and ionization chamber measurements adapting the methodology of the MMPG5a report. The methodology presented can be applied to validate other forward-projection transit dosimetry software.
Collapse
Affiliation(s)
- David Sánchez‐Artuñedo
- Servei de Física i Protecció RadiològicaHospital Universitari Vall d'HebronBarcelonaSpain
| | - Savannah Pié‐Padró
- Servei de Física i Protecció RadiològicaHospital Universitari Vall d'HebronBarcelonaSpain
| | | | | | | |
Collapse
|
5
|
Stedem A, Tutty M, Chofor N, Langhans M, Kleefeld C, Schönfeld AA. Systematic evaluation of spatial resolution and gamma criteria for quality assurance with detector arrays in stereotactic radiosurgery. J Appl Clin Med Phys 2024; 25:e14274. [PMID: 38265979 PMCID: PMC10860444 DOI: 10.1002/acm2.14274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 12/08/2023] [Accepted: 01/02/2024] [Indexed: 01/26/2024] Open
Abstract
PURPOSE To characterize detector array spacing and gamma index for quality assurance (QA) of stereotactic radiosurgery (SRS) deliveries. Use the Nyquist theorem to determine the required detector spacing in SRS fields, and find optimal gamma indices to detect MLC errors using the SRS MapCHECK, ArcCHECK, and a portal imaging device (EPID). METHODS The required detector spacing was determined via Fourier analysis of small radiation fields and profiles of typical SRS treatment plans. The clinical impact of MLC errors of 0.5, 1, and 2 mm was evaluated. Global gamma (low-dose threshold 10%) was evaluated for the three detector systems using various combinations of the distance to agreement and the dose difference. RESULTS While MLC errors only slightly affected mean dose to PTV and a 2 mm thick surrounding structure (PTV_2 mm), significant PTV underdose incurred with increase in maximum dose to PTV_2 mm. Gamma indices with highest sensitivity to the introduced errors at 95% tolerance level for plans on target volumes of 3.2 cm3 (plan 3 cc) and 35.02 cm3 (plan 35 cc) were 2%/1 mm for the SRS MapCHECK and 2%/3 mm for the ArcCHECK, with 3%/1 mm (plan 3cc) and 2%/1 mm (plan 35cc) for the EPID. Drops in passing rates for a 2 mm MLC error were (46.2%, 41.6%) for the SRS MapCHECK and (12.2%, 4.2%) for the ArcCHECK for plan 3cc and plan 35cc, respectively. For Portal Dose, values were 4.5% (plan 3cc) and 7% (plan 35cc). The Nyquist frequency of two SRS dose distributions lie between 0.26 and 0.1 mm-1 , corresponding to detector spacings of 1.9 and 5 mm. Evaluation of SRS MapCHECK data with doubled detector density indicates that increased detector density may reduce the system's sensitivity to errors, necessitating a tighter gamma index. CONCLUSIONS The present results give insight on the performance of detector arrays and gamma indices for the investigated detectors during SRS QA.
Collapse
Affiliation(s)
- Ann‐Kathrin Stedem
- Asklepios Klinik St. GeorgHermann‐Holthusen‐Institut für StrahlentherapieHamburgGermany
| | - Mark Tutty
- Radiotherapy DepartmentBeacon HospitalDublinIreland
| | - Ndimofor Chofor
- Physics Research and OutreachSun NuclearA Mirion Medical CompanyNorderstedtGermany
| | | | - Christoph Kleefeld
- National University of IrelandSchool of PhysicsUniversity RoadGalwayIreland
| | - Andreas A. Schönfeld
- Physics Research and OutreachSun NuclearA Mirion Medical CompanyNorderstedtGermany
| |
Collapse
|
6
|
Claessens M, De Kerf G, Vanreusel V, Mollaert I, Hernandez V, Saez J, Jornet N, Verellen D. Multi-institutional generalizability of a plan complexity machine learning model for predicting pre-treatment quality assurance results in radiotherapy. Phys Imaging Radiat Oncol 2024; 29:100525. [PMID: 38204910 PMCID: PMC10776441 DOI: 10.1016/j.phro.2023.100525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Revised: 12/05/2023] [Accepted: 12/12/2023] [Indexed: 01/12/2024] Open
Abstract
Background and purpose Treatment plans in radiotherapy are subject to measurement-based pre-treatment verifications. In this study, plan complexity metrics (PCMs) were calculated per beam and used as input features to develop a predictive model. The aim of this study was to determine the robustness against differences in machine type and institutional-specific quality assurance (QA). Material and methods A number of 567 beams were collected, where 477 passed and 90 failed the pre-treatment QA. Treatment plans of different anatomical regions were included. One type of linear accelerator was represented. For all beams, 16 PCMs were calculated. A random forest classifier was trained to distinct between acceptable and non-acceptable beams. The model was validated on other datasets to investigate its robustness. Firstly, plans for another machine type from the same institution were evaluated. Secondly, an inter-institutional validation was conducted on three datasets from different centres with their associated QA. Results Intra-institutionally, the PCMs beam modulation, mean MLC gap, Q1 gap, and Modulation Complexity Score were the most informative to detect failing beams. Eighty-tree percent of the failed beams (15/18) were detected correctly. The model could not detect over-modulated beams of another machine type. Inter-institutionally, the model performance reached higher accuracy for centres with comparable equipment both for treatment and QA as the local institute. Conclusions The study demonstrates that the robustness decreases when major differences appear in the QA platform or in planning strategies, but that it is feasible to extrapolate institutional-specific trained models between centres with similar clinical practice. Predictive models should be developed for each machine type.
Collapse
Affiliation(s)
- Michaël Claessens
- Department of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium
- Centre for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), University of Antwerp, Antwerp, Belgium
| | - Geert De Kerf
- Department of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium
| | - Verdi Vanreusel
- Department of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium
- Centre for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), University of Antwerp, Antwerp, Belgium
- Research in Dosimetric Applications (RDA), SCK CEN, Mol (Antwerp), Belgium
| | - Isabelle Mollaert
- Department of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium
| | - Victor Hernandez
- Department of Medical Physics, Hospital Sant Joan de Reus, IISPV, 43204 Tarragona, Spain
| | - Jordi Saez
- Department of Radiation Oncology, Hospital Clínic de Barcelona, 08036 Barcelona, Spain
| | - Núria Jornet
- Servei de Radiofísica i Radioprotecció, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Dirk Verellen
- Department of Radiation Oncology, Iridium Netwerk, Wilrijk (Antwerp), Belgium
- Centre for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), University of Antwerp, Antwerp, Belgium
| |
Collapse
|
7
|
Esposito M, Mancosu P, Bruschi A, Ghirelli A, Pini S, Alpi P, Barca R, Paoli CD, Meacci F, Leonulli BG, Fondelli S, Paoletti L, Scoccianti S, Russo S. The role of EPID in vivo dosimetry in the risk management of stereotactic lung treatments. Strahlenther Onkol 2023; 199:992-999. [PMID: 37256302 DOI: 10.1007/s00066-023-02081-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Accepted: 03/26/2023] [Indexed: 06/01/2023]
Abstract
BACKGROUND AND OBJECTIVE In this work we report our experience with the use of in vivo dosimetry (IVD) in the risk management of stereotactic lung treatments. METHODS A commercial software based on the electronic portal imaging device (EPID) signal was used to reconstruct the actual planning target volume (PTV) dose of stereotactic lung treatments. The study was designed in two phases: i) in the observational phase, the IVD results of 41 consecutive patients were reviewed and out-of-tolerance cases were studied for root cause analysis; ii) in the active phase, the IVD results of 52 patients were analyzed and corrective actions were taken when needed. Moreover, proactive preventions were further introduced to reduce the risk of future failures. The error occurrence rate was analyzed to evaluate the effectiveness of proactive actions. RESULTS A total of 330 fractions were analyzed. In the first phase, 13 errors were identified. In the active phase, 12 errors were detected, 5 of which needed corrective actions; in 4 patients the actions taken corrected the error. Several preventions and barriers were introduced to reduce the risk of future failures: the planning checklist was updated, the procedure for vacuum pillows was improved, and use of the respiratory compression belt was optimized. A decrease in the failure rate was observed, showing the effectiveness of procedural adjustment. CONCLUSION The use of IVD allowed the quality of lung stereotactic body radiation therapy (SBRT) treatments to be improved. Patient-specific and procedural corrective actions were successfully taken as part of risk management, leading to an overall improvement in the dosimetric accuracy.
Collapse
Affiliation(s)
- Marco Esposito
- S. C. Fisica Sanitaria, Firenze-Azienda Sanitaria USL Toscana Centro, Via dell'Antella 58, 50012, Bagno a Ripoli, Firenze, Italy.
- International Center for Theoretical Physics, Strada Costiera, 11, 34151, Trieste, Italy.
| | - Pietro Mancosu
- Medical Physics Unit of Radiotherapy Dept., IRCCS Humanitas Research Hospital, Rozzano, Italy
| | - Andrea Bruschi
- S. C. Fisica Sanitaria, Firenze-Azienda Sanitaria USL Toscana Centro, Via dell'Antella 58, 50012, Bagno a Ripoli, Firenze, Italy
| | - Alessandro Ghirelli
- S. C. Fisica Sanitaria, Firenze-Azienda Sanitaria USL Toscana Centro, Via dell'Antella 58, 50012, Bagno a Ripoli, Firenze, Italy
| | - Silvia Pini
- S. C. Fisica Sanitaria, Firenze-Azienda Sanitaria USL Toscana Centro, Via dell'Antella 58, 50012, Bagno a Ripoli, Firenze, Italy
| | - Paolo Alpi
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | - Raffaella Barca
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | - Camilla Delli Paoli
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | - Fiammetta Meacci
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | | | - Simona Fondelli
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | - Lisa Paoletti
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | - Silvia Scoccianti
- S. C. Radioterapia, Firenze-Azienda Sanitaria USL Toscana Centro, Firenze, Italy
| | - Serenella Russo
- S. C. Fisica Sanitaria, Firenze-Azienda Sanitaria USL Toscana Centro, Via dell'Antella 58, 50012, Bagno a Ripoli, Firenze, Italy
| |
Collapse
|
8
|
Stevens S, Moloney S, Blackmore A, Hart C, Rixham P, Bangiri A, Pooler A, Doolan P. IPEM topical report: guidance for the clinical implementation of online treatment monitoring solutions for IMRT/VMAT. Phys Med Biol 2023; 68:18TR02. [PMID: 37531959 DOI: 10.1088/1361-6560/acecd0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 08/02/2023] [Indexed: 08/04/2023]
Abstract
This report provides guidance for the implementation of online treatment monitoring (OTM) solutions in radiotherapy (RT), with a focus on modulated treatments. Support is provided covering the implementation process, from identification of an OTM solution to local implementation strategy. Guidance has been developed by a RT special interest group (RTSIG) working party (WP) on behalf of the Institute of Physics and Engineering in Medicine (IPEM). Recommendations within the report are derived from the experience of the WP members (in consultation with manufacturers, vendors and user groups), existing guidance or legislation and a UK survey conducted in 2020 (Stevenset al2021). OTM is an inclusive term representing any system capable of providing a direct or inferred measurement of the delivered dose to a RT patient. Information on each type of OTM is provided but, commensurate with UK demand, guidance is largely influenced byin vivodosimetry methods utilising the electronic portal imager device (EPID). Sections are included on the choice of OTM solutions, acceptance and commissioning methods with recommendations on routine quality control, analytical methods and tolerance setting, clinical introduction and staffing/resource requirements. The guidance aims to give a practical solution to sensitivity and specificity testing. Functionality is provided for the user to introduce known errors into treatment plans for local testing. Receiver operating characteristic analysis is discussed as a tool to performance assess OTM systems. OTM solutions can help verify the correct delivery of radiotherapy treatment. Furthermore, modern systems are increasingly capable of providing clinical decision-making information which can impact the course of a patient's treatment. However, technical limitations persist. It is not within the scope of this guidance to critique each available solution, but the user is encouraged to carefully consider workflow and engage with manufacturers in resolving compatibility issues.
Collapse
Affiliation(s)
| | - Stephen Moloney
- University Hospitals Dorset NHS Foundation Trust, Poole, United Kingdom
| | | | - Clare Hart
- Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom
| | - Philip Rixham
- Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom
| | - Anna Bangiri
- Nottingham University Hospitals NHS Trust, Nottingham, United Kingdom
| | - Alistair Pooler
- Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, United Kingdom
| | | |
Collapse
|
9
|
Dogan N, Mijnheer BJ, Padgett K, Nalichowski A, Wu C, Nyflot MJ, Olch AJ, Papanikolaou N, Shi J, Holmes SM, Moran J, Greer PB. AAPM Task Group Report 307: Use of EPIDs for Patient-Specific IMRT and VMAT QA. Med Phys 2023; 50:e865-e903. [PMID: 37384416 PMCID: PMC11230298 DOI: 10.1002/mp.16536] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 04/23/2023] [Accepted: 05/15/2023] [Indexed: 07/01/2023] Open
Abstract
PURPOSE Electronic portal imaging devices (EPIDs) have been widely utilized for patient-specific quality assurance (PSQA) and their use for transit dosimetry applications is emerging. Yet there are no specific guidelines on the potential uses, limitations, and correct utilization of EPIDs for these purposes. The American Association of Physicists in Medicine (AAPM) Task Group 307 (TG-307) provides a comprehensive review of the physics, modeling, algorithms and clinical experience with EPID-based pre-treatment and transit dosimetry techniques. This review also includes the limitations and challenges in the clinical implementation of EPIDs, including recommendations for commissioning, calibration and validation, routine QA, tolerance levels for gamma analysis and risk-based analysis. METHODS Characteristics of the currently available EPID systems and EPID-based PSQA techniques are reviewed. The details of the physics, modeling, and algorithms for both pre-treatment and transit dosimetry methods are discussed, including clinical experience with different EPID dosimetry systems. Commissioning, calibration, and validation, tolerance levels and recommended tests, are reviewed, and analyzed. Risk-based analysis for EPID dosimetry is also addressed. RESULTS Clinical experience, commissioning methods and tolerances for EPID-based PSQA system are described for pre-treatment and transit dosimetry applications. The sensitivity, specificity, and clinical results for EPID dosimetry techniques are presented as well as examples of patient-related and machine-related error detection by these dosimetry solutions. Limitations and challenges in clinical implementation of EPIDs for dosimetric purposes are discussed and acceptance and rejection criteria are outlined. Potential causes of and evaluations of pre-treatment and transit dosimetry failures are discussed. Guidelines and recommendations developed in this report are based on the extensive published data on EPID QA along with the clinical experience of the TG-307 members. CONCLUSION TG-307 focused on the commercially available EPID-based dosimetric tools and provides guidance for medical physicists in the clinical implementation of EPID-based patient-specific pre-treatment and transit dosimetry QA solutions including intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) treatments.
Collapse
Affiliation(s)
- Nesrin Dogan
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Ben J Mijnheer
- Department of Radiation Oncology, Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Kyle Padgett
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, Florida, USA
| | - Adrian Nalichowski
- Department of Radiation Oncology, Karmanos Cancer Institute, Detroit, Michigan, USA
| | - Chuan Wu
- Department of Radiation Oncology, Sutter Medical Foundation, Roseville, California, USA
| | - Matthew J Nyflot
- Department of Radiation Oncology, University of Washington, Seattle, Washington, USA
| | - Arthur J Olch
- Department of Radiation Oncology, University of Southern California, and Children's Hospital Los Angeles, Los Angeles, California, USA
| | - Niko Papanikolaou
- Division of Medical Physics, UT Health-MD Anderson, San Antonio, Texas, USA
| | - Jie Shi
- Sun Nuclear Corporation - A Mirion Medical Company, Melbourne, Florida, USA
| | | | - Jean Moran
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Peter B Greer
- Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, NSW, Australia
- School of Information and Physical Sciences, University of Newcastle, Newcastle, NSW, Australia
| |
Collapse
|
10
|
A C Fiagan Y, Bossuyt E, Nevens D, Machiels M, Chiairi I, Joye I, Paul M, Gevaert T, Verellen D. The use of in-vivo dosimetry to identify head and neck cancer patients needing adaptive radiotherapy. Radiother Oncol 2023; 184:109676. [PMID: 37084887 DOI: 10.1016/j.radonc.2023.109676] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 04/12/2023] [Accepted: 04/12/2023] [Indexed: 04/23/2023]
Abstract
BACKGROUND AND PURPOSE Head and neck cancer (HNC) patients experiencing anatomical changes during their radiotherapy (RT) course may benefit from adaptive RT (ART). We investigated the sensitivity of an electronic portal imaging device (EPID)-based in-vivo dosimetry (EIVD) systemto detect patients that require ART and identified its limitations. MATERIALS AND METHODS A retrospective study was conducted for 182 HNC patients: laryngeal cancer without elective lymph nodes (group A), postoperative RT (group B) and primary RT including elective lymph nodes (group C). The effect of anatomical changes on the dose distribution and volumetric changes was quantified. The receiver operating characteristic curve was used to obtain the optimal cut-off value for the gamma passing rate (%GP) with a dose difference of 3% and a distance to agreement of 3mm. RESULTS Fifty HNC patients receiving ART were analyzed: 1 in group A, 10 in group B and 39 in group C. Failed fractions (FFs) occurred in 1/1, 6/10 and 23/39 cases before ART in group A, B and C respectively. In the four cases in group B without FFs, only minor dosimetric changes were observed. One of the cases in group C without FFs had significant dosimetric changes (false negative). Three cases received ART because of clinical reasons that cannot be detected by EIVD. The optimal cut-off value for the %GP was 95%/95.2% for old/new generation machines respectively. CONCLUSION EIVD in combined with 3D imaging techniques can be synergistic in the detection of anatomical changes in HNC patients who benefit from ART.
Collapse
Affiliation(s)
- Yawo A C Fiagan
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium.
| | - Evy Bossuyt
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium
| | - Daan Nevens
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Health Sciences, Center for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), Universiteit Antwerpen, Antwerp, Belgium
| | - Melanie Machiels
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Health Sciences, Center for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), Universiteit Antwerpen, Antwerp, Belgium
| | - Ibrahim Chiairi
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Health Sciences, Center for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), Universiteit Antwerpen, Antwerp, Belgium
| | - Ines Joye
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Health Sciences, Center for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), Universiteit Antwerpen, Antwerp, Belgium
| | - Meijnders Paul
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Health Sciences, Center for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), Universiteit Antwerpen, Antwerp, Belgium
| | - Thierry Gevaert
- Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium; Department of Radiation Oncology, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Dirk Verellen
- Iridium Netwerk, Radiation Oncology, Antwerp, Belgium; Faculty of Medicine and Health Sciences, Center for Oncological Research (CORE), Integrated Personalized and Precision Oncology Network (IPPON), Universiteit Antwerpen, Antwerp, Belgium
| |
Collapse
|
11
|
van Reenen CJ, Trauernicht CJ, Bojechko C. The application of gradient dose segmented analysis of in-vivo EPID images for patients undergoing VMAT in a resource-constrained environment. J Appl Clin Med Phys 2023:e13985. [PMID: 37051765 PMCID: PMC10402667 DOI: 10.1002/acm2.13985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 03/13/2023] [Accepted: 03/20/2023] [Indexed: 04/14/2023] Open
Abstract
The gamma analysis metric is a commonly used metric for VMAT plan evaluation. The major drawback of this is the lack of correlation between gamma passing rates and DVH values. The novel GDSAmean metric was developed by Steers et al. to quantify changes in the PTV mean dose (Dmean ) for VMAT patients. The aim of this work is to apply the GDSA retrospectively on head-and-neck cancer patients treated on the newly acquired Varian Halcyon, to assess changes in GDSAmean , and to evaluate the cause of day-to-day changes in the time-plot series. In-vivo EPID transmission images of head-and-neck cancer patients treated between August 2019 and July 2020 were analyzed retrospectively. The GDSAmean was determined for all patients treated. The changes in patient anatomy and rotational errors were quantified using the daily CBCT images and added to a time-plot with the daily change in GDSAmean . Over 97% of the delivered treatment fractions had a GDSAmean < 3%. Thirteen of the patients received at least one treatment fraction where the GDSAmean > 3%. Most of these deviations occurred for the later fractions of radiotherapy treatment. Additionally, 92% of these patients were treated for malignancies involving the larynx and oropharynx. Notable deviations in the effective separation diameters were observed for 62% of the patients where the change in GDSAmean > 3%. For the other five cases with GDSAmean < 3%, the mean pitch, roll, and yaw rotational errors were 0.90°, 0.45°, and 0.43°, respectively. A GDSAmean > 3% was more likely due to a change in separation, whereas a GDSAmean < 3% was likely caused by rotational errors. Pitch errors were shown to be the most dominant. The GDSAmean is easily implementable and can aid in scheduling new CT scans for patients before significant deviations in dose delivery occur.
Collapse
Affiliation(s)
- Christoffel Jacobus van Reenen
- Department of Medical Imaging and Radiation Oncology, Medical Physics Division, Stellenbosch University, Cape Town, Western Cape, South Africa
| | - Christoph Jan Trauernicht
- Department of Medical Imaging and Radiation Oncology, Medical Physics Division, Stellenbosch University, Cape Town, Western Cape, South Africa
| | - Casey Bojechko
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, San Diego, California, USA
| |
Collapse
|
12
|
Mao SPH, Han-Oh S, Moore J, Huang E, McNutt TR, Souranis AN, Briner V, Halthore A, Alcorn SR, Meyer JJ, Viswanathan AN, Wright JL. Selective de-implementation of routine in vivo dosimetry. J Appl Clin Med Phys 2023:e13953. [PMID: 36877712 DOI: 10.1002/acm2.13953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 01/25/2023] [Accepted: 01/30/2023] [Indexed: 03/07/2023] Open
Abstract
As cone-beam computed tomography (CBCT) has become the localization method for a majority of cases, the indications for diode-based confirmation of accurate patient set-up and treatment are now limited and must be balanced between proper resource allocation and optimizing efficiency without compromising safety. We undertook a de-implementation quality improvement project to discontinue routine diode use in non-intensity modulated radiotherapy (IMRT) cases in favor of tailored selection of scenarios where diodes may be useful. After analysis of safety reports from the last 5 years, literature review, and stakeholder discussions, our safety and quality (SAQ) committee introduced a recommendation to limit diode use to specific scenarios in which in vivo verification may add value to standard quality assurance (QA) processes. To assess changes in patterns of use, we reviewed diode use by clinical indication 4 months prior and after the implementation of the revised policy, which includes use of diodes for: 3D conformal photon fields set up without CBCT; total body irradiation (TBI); electron beams; cardiac devices within 10 cm of the treatment field; and unique scenarios on a case-by-case basis. We identified 4459 prescriptions and 1038 unique instances of diode use across five clinical sites from 5/2021 to 1/2022. After implementation of the revised policy, we observed an overall decrease in diode use from 32% to 13.2%, with a precipitous drop in 3D cases utilizing CBCT (from 23.2% to 4%), while maintaining diode utilization in the 5 selected scenarios including 100% of TBI and electron cases. By identifying specific indications for diode use and creating a user-friendly platform for case selection, we have successfully de-implemented routine diode use in favor of a selective process that identifies cases where the diode is important for patient safety. In doing so, we have streamlined patient care and decreased cost without compromising patient safety.
Collapse
Affiliation(s)
- Serena P H Mao
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Sarah Han-Oh
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Joseph Moore
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Ellen Huang
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Todd R McNutt
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Annette N Souranis
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Valerie Briner
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Aditya Halthore
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Sarah R Alcorn
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Jeffrey J Meyer
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Akila N Viswanathan
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| | - Jean L Wright
- Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD, USA
| |
Collapse
|
13
|
Bossuyt E, Nevens D, Weytjens R, Taieb Mokaddem A, Verellen D. Assessing the impact of adaptations to the clinical workflow in radiotherapy using transit in vivo dosimetry. Phys Imaging Radiat Oncol 2023; 25:100420. [PMID: 36820237 PMCID: PMC9937948 DOI: 10.1016/j.phro.2023.100420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 01/26/2023] [Accepted: 01/26/2023] [Indexed: 01/31/2023] Open
Abstract
Background and Purpose Currently in-vivo dosimetry (IVD) is primarily used to identify individual patient errors in radiotherapy. This study investigated possible correlations of observed trends in transit IVD results, with adaptations to the clinical workflow, aiming to demonstrate the possibility of using the bulk data for continuous quality improvement. Materials and methods In total 84,100 transit IVD measurements were analyzed of all patients treated between 2018 and 2022, divided into four yearly periods. Failed measurements (FM) were divided per pathology and into four categories of causes of failure: technical, planning and positioning problems, and anatomic changes. Results The number of FM due to patient related problems gradually decreased from 9.5% to 6.6%, 6.1% and 5.6% over the study period. FM attributed to positioning problems decreased from 10.0% to 4.9% in boost breast cancer patients after introduction of extra imaging, from 9.1% to 3.9% in Head&Neck patients following education of radiation therapists on positioning of patients' shoulders, from 6.1% to 2.8% in breast cancer patients after introduction of ultrahypofractionated breast radiotherapy with daily online pre-treatment imaging and from 11.2% to 4.3% in extremities following introduction of immobilization with calculated couch parameters and a Surface Guided Radiation Therapy solution. FM related to anatomic changes decreased from 10.2% to 4.0% in rectum patients and from 6.7% to 3.3% in prostate patients following more patient education from dieticians. Conclusions Our study suggests that IVD can be a powerful tool to assess the impact of adaptations to the clinical workflow and its use for continuous quality improvement.
Collapse
Affiliation(s)
- Evy Bossuyt
- Iridium Netwerk, GZA Hospitals, Radiation Oncology Department, Antwerp, Belgium,Corresponding author.
| | - Daan Nevens
- Iridium Netwerk, GZA Hospitals, Radiation Oncology Department, Antwerp, Belgium,Faculty of Medicine and Health Sciences, Antwerp University, Antwerp, Belgium
| | - Reinhilde Weytjens
- Iridium Netwerk, GZA Hospitals, Radiation Oncology Department, Antwerp, Belgium
| | | | - Dirk Verellen
- Iridium Netwerk, GZA Hospitals, Radiation Oncology Department, Antwerp, Belgium,Faculty of Medicine and Health Sciences, Antwerp University, Antwerp, Belgium
| |
Collapse
|
14
|
Skrobala A, Kruszyna-Mochalska M, Graczyk K, Ryczkowski A, Fundowicz M, Milecki P, Malicki J. Radiotherapy planning in a prostate cancer phantom model with intraprostatic dominant lesions using stereotactic body radiotherapy with volumetric modulated arcs and a simultaneous integrated boost. Front Oncol 2023; 13:1147593. [PMID: 37188175 PMCID: PMC10175813 DOI: 10.3389/fonc.2023.1147593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 04/10/2023] [Indexed: 05/17/2023] Open
Abstract
Aim In the treatment of prostate cancer with radiation therapy, the addition of a simultaneous integrated boost (SIB) to the dominant intraprostatic lesions (DIL) may improve local control. In this study, we aimed to determine the optimal radiation strategy in a phantom model of prostate cancer using volumetric modulated arc therapy for stereotactic body radiotherapy (SBRT-VMAT) with a SIB of 1-4 DILs. Methods We designed and printed a three-dimensional anthropomorphic phantom pelvis to simulate individual patient structures, including the prostate gland. A total of 36.25 Gy (SBRT) was delivered to the whole prostate. The DILs were irradiated with four different doses (40, 45, 47.5, and 50 Gy) to assess the influence of different SIB doses on dose distribution. The doses were calculated, verified, and measured using both transit and non-transit dosimetry for patient-specific quality assurance using a phantom model. Results The dose coverage met protocol requirements for all targets. However, the dose was close to violating risk constraints to the rectum when four DILs were treated simultaneously or when the DILs were located in the posterior segments of the prostate. All verification plans passed the assumed tolerance criteria. Conclusions Moderate dose escalation up to 45 Gy seems appropriate in cases with DILs located in posterior prostate segments or if there are three or more DILs located in other segments.
Collapse
Affiliation(s)
- Agnieszka Skrobala
- Department of Electroradiology, Poznan University of Medical Science, Poznan, Poland
- Department of Medical Physics, Greater Poland Cancer Centre, Poznan, Poland
- *Correspondence: Agnieszka Skrobala,
| | - Marta Kruszyna-Mochalska
- Department of Electroradiology, Poznan University of Medical Science, Poznan, Poland
- Department of Medical Physics, Greater Poland Cancer Centre, Poznan, Poland
| | - Kinga Graczyk
- Department of Medical Physics, Greater Poland Cancer Centre, Poznan, Poland
| | - Adam Ryczkowski
- Department of Medical Physics, Greater Poland Cancer Centre, Poznan, Poland
| | - Magdalena Fundowicz
- Department of Radiation Oncology I, Greater Poland Cancer Centre, Poznan, Poland
| | - Piotr Milecki
- Department of Electroradiology, Poznan University of Medical Science, Poznan, Poland
- Department of Radiation Oncology I, Greater Poland Cancer Centre, Poznan, Poland
| | - Julian Malicki
- Department of Electroradiology, Poznan University of Medical Science, Poznan, Poland
| |
Collapse
|
15
|
Kosaka T, Takatsu J, Inoue T, Hara N, Mitsuhashi T, Suzuki M, Shikama N. Effective clinical applications of Monte Carlo-based independent secondary dose verification software for helical tomotherapy. Phys Med 2022; 104:112-122. [PMID: 36395639 DOI: 10.1016/j.ejmp.2022.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 10/28/2022] [Accepted: 11/05/2022] [Indexed: 11/17/2022] Open
Abstract
PURPOSE To investigate the scope of the effective clinical application of Monte Carlo (MC)-based independent dose verification software for helical tomotherapy. METHODS DoseCHECK was selected as the MC-based dose calculation software. First, the dose calculation accuracy of DoseCHECK was evaluated with film and chamber measurements in a water-equivalent phantom. Second, the dose calculation accuracy was examined in several heterogeneous materials. Finally, dosimetric comparisons between DoseCHECK and the treatment planning system (TPS) were performed for clinical patient plans. Prostate IMRT, head and neck IMRT (HN), total body irradiation (TBI), and brain stereotactic radiotherapy (SRT) were evaluated. RESULT The DoseCHECK calculations agreed with the chamber and film measurements in the homogenous phantom. For heterogeneous phantom cases, the dose differences between DoseCHECK and TPS were within 3 %, except in air, in which large dose differences of 20 % were observed. In clinical patient plans, the median dose differences between the lung Dmean in TBI cases and the normal brain Dmean in brain SRT cases were significantly >3 %. For HN and brain SRT cases, the median target dose differences were >3 %. CONCLUSION Our results show that independent dose verification with the MC algorithm can detect systematic errors caused by the lack of heterogeneity correction in the TPS. In particular, MC-based independent dose verification is required for HN, TBI, and brain SRT cases in helical tomotherapy.
Collapse
Affiliation(s)
- Takahiro Kosaka
- Department of Radiation Oncology, Graduate School of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan; Department of Radiology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu-shi, Chiba 279-0021, Japan.
| | - Jun Takatsu
- Department of Radiation Oncology, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan.
| | - Tatsuya Inoue
- Department of Radiology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu-shi, Chiba 279-0021, Japan; Department of Radiation Oncology, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan.
| | - Naoya Hara
- Department of Radiology, Juntendo University Hospital, 3-1-3 Hongo, Bunkyo-ku, Tokyo 113-8431, Japan.
| | - Taira Mitsuhashi
- Department of Radiology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu-shi, Chiba 279-0021, Japan.
| | - Michimasa Suzuki
- Department of Radiology, Juntendo University Urayasu Hospital, 2-1-1 Tomioka, Urayasu-shi, Chiba 279-0021, Japan.
| | - Naoto Shikama
- Department of Radiation Oncology, Graduate School of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan; Department of Radiation Oncology, Faculty of Medicine, Juntendo University, 2-1-1 Hongo, Bunkyo-ku, Tokyo 113-8421, Japan; Department of Radiology, Juntendo University Hospital, 3-1-3 Hongo, Bunkyo-ku, Tokyo 113-8431, Japan.
| |
Collapse
|
16
|
Chen L, Zhang Z, Yu L, Peng J, Feng B, Zhao J, Liu Y, Xia F, Zhang Z, Hu W, Wang J. A clinically relevant online patient QA solution with daily CT scans and EPID-based in vivo dosimetry: a feasibility study on rectal cancer. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac9950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Accepted: 10/11/2022] [Indexed: 11/06/2022]
Abstract
Abstract
Objective. Adaptive radiation therapy (ART) could protect organs at risk (OARs) while maintain high dose coverage to targets. However, there is still a lack of efficient online patient quality assurance (QA) methods, which is an obstacle to large-scale adoption of ART. We aim to develop a clinically relevant online patient QA solution for ART using daily CT scans and EPID-based in vivo dosimetry. Approach. Ten patients with rectal cancer at our center were included. Patients’ daily CT scans and portal images were collected to generate reconstructed 3D dose distributions. Contours of targets and OARs were recontoured on these daily CT scans by a clinician or an auto-segmentation algorithm, then dose-volume indices were calculated, and the percent deviation of these indices to their original plans were determined. This deviation was regarded as the metric for clinically relevant patient QA. The tolerance level was obtained using a 95% confidence interval of the QA metric distribution. These deviations could be further divided into anatomically relevant or delivery relevant indicators for error source analysis. Finally, our QA solution was validated on an additional six clinical patients. Main results. In rectal cancer, the 95% confidence intervals of the QA metric for PTV ΔD
95 (%) were [−3.11%, 2.35%], and for PTV ΔD
2 (%) were [−0.78%, 3.23%]. In validation, 68% for PTV ΔD
95 (%), and 79% for PTV ΔD
2 (%) of the 28 fractions are within tolerances of the QA metrics. one patient’s dosimetric impact of anatomical variations during treatment were observed through the source of error analysis. Significance. The online patient QA solution using daily CT scans and EPID-based in vivo dosimetry is clinically feasible. Source of error analysis has the potential for distinguishing sources of error and guiding ART for future treatments.
Collapse
|
17
|
Vasina EN, Kong N, Greer P, Baeza Ortega J, Kron T, Ludbrook JJ, Thwaites D, Lehmann J. First clinical experience with real-time portal imaging-based breath-hold monitoring in tangential breast radiotherapy. Phys Imaging Radiat Oncol 2022; 24:1-6. [PMID: 36092771 PMCID: PMC9450128 DOI: 10.1016/j.phro.2022.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 08/09/2022] [Accepted: 08/09/2022] [Indexed: 11/28/2022] Open
Abstract
Background and purpose Real-time treatment monitoring with the electronic portal imaging device (EPID) can conceptually provide a more accurate assessment of the quality of deep inspiration breath-hold (DIBH) and patient movement during tangential breast radiotherapy (RT). A system was developed to measure two geometrical parameters, the lung depth (LD) and the irradiated width (named here skin distance, SD), along three user-selected lines in MV EPID images of breast tangents. The purpose of this study was to test the system during tangential breast RT with DIBH. Materials and methods Measurements of LDs and SDs were carried out in real time. DIBH was guided with a commercial system using a marker block. Results from 17 patients were assessed. Mean midline LDs, <mLDs>, per tangent were compared to the planned mLDs; differences between the largest and smallest observed <mLDs> (<mSDs>) per tangent were calculated. Results For 56% (162/288) of the tangents tested, <mLDs> were outside the tolerance window. All but one patient had at least one fraction showing this behaviour. The largest difference found between an <mLD> and its planned mLD was −16.9 mm. The accuracy of patient positioning and the quality of marker-block-based DIBH guidance contributed to the differences. Fractions with patient position verification using a single EPID image taken before treatment showed a lower rate (34%), suggesting reassessment of setup procedures. Conclusions Real-time treatment monitoring of the internal anatomy during DIBH delivery of tangential breast RT is feasible and useful. The new system requires no additional radiation for the patient.
Collapse
Affiliation(s)
- Elena N. Vasina
- School of Information and Physical Sciences, University of Newcastle, Newcastle, Australia
- Corresponding author at: School of Information and Physical Sciences, University of Newcastle, University Drive, Callaghan, NSW 2308, Australia.
| | - Natalie Kong
- Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, Australia
| | - Peter Greer
- School of Information and Physical Sciences, University of Newcastle, Newcastle, Australia
- Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, Australia
| | - Jose Baeza Ortega
- School of Information and Physical Sciences, University of Newcastle, Newcastle, Australia
| | - Tomas Kron
- Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia
| | - Joanna J. Ludbrook
- Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, Australia
| | - David Thwaites
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
| | - Joerg Lehmann
- School of Information and Physical Sciences, University of Newcastle, Newcastle, Australia
- Department of Radiation Oncology, Calvary Mater Newcastle, Newcastle, Australia
- Institute of Medical Physics, School of Physics, University of Sydney, Sydney, Australia
| |
Collapse
|
18
|
Wolfs CJ, Verhaegen F. What is the optimal input information for deep learning-based pre-treatment error identification in radiotherapy? Phys Imaging Radiat Oncol 2022; 24:14-20. [PMID: 36106060 PMCID: PMC9465434 DOI: 10.1016/j.phro.2022.08.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 08/17/2022] [Accepted: 08/18/2022] [Indexed: 11/21/2022] Open
Abstract
The choice of dose comparison method impacts deep learning error identification accuracy most. Simple dose comparison methods are more beneficial than gamma analysis and alternative methods. Mean/standard deviation normalization and high image resolution improve error identification.
Background and purpose Deep learning (DL) provides high sensitivity for detecting and identifying errors in pre-treatment radiotherapy quality assurance (QA). This work’s objective was to systematically evaluate the impact of different dose comparison and image preprocessing methods on DL model performance for error identification in pre-treatment QA. Materials and methods For 53 volumetric modulated arc therapy (VMAT) and 69 stereotactic body radiotherapy (SBRT) treatment plans of lung cancer patients, mechanical errors were simulated (MLC leaf positions, monitor unit scaling, collimator rotation). Two classification levels were assessed: error type (Level 1) and error magnitude (Level 2). Portal dose images with and without errors were compared using standard (gamma analysis), simple (absolute/relative dose difference, ratio) and alternative (distance-to-agreement, structural similarity index, gradient) dose comparison methods. For preprocessing, different normalization methods (min/max and mean/standard deviation) and image resolutions (32 × 32, 64 × 64 and 128 × 128) were evaluated. All possible combinations of classification level, dose comparison, normalization method and image size resulted in 144 input datasets for DL networks for error identification. Results Average accuracy was highest for simple dose comparison methods (Level 1: 97.7%, Level 2: 78.1%) while alternative methods scored lowest (Level 1: 91.6%, Level 2: 71.2%). Mean/stdev normalization particularly improved Level 2 classification. Higher image resolution improved error identification, although for SBRT lower image resolution was also sufficient. Conclusions The choice of dose comparison method has the largest impact on error identification for pre-treatment QA using DL, compared to image preprocessing. Model performance can improve by using simple dose comparison methods, mean/stdev normalization and high image resolution.
Collapse
Affiliation(s)
- Cecile J.A. Wolfs
- Corresponding author at: Dr Tanslaan 12, 6229 ET Maastricht, the Netherlands.
| | | |
Collapse
|
19
|
Olaciregui-Ruiz I, Osinga-Blaettermann JM, Ortega-Marin K, Mijnheer B, Mans A. Extending in aqua portal dosimetry with dose inhomogeneity conversion maps for accurate patient dose reconstruction in external beam radiotherapy. Phys Imaging Radiat Oncol 2022; 22:20-27. [PMID: 35493851 PMCID: PMC9038561 DOI: 10.1016/j.phro.2022.04.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Revised: 04/07/2022] [Accepted: 04/08/2022] [Indexed: 11/24/2022] Open
|
20
|
Fiagan YA, Bossuyt E, Machiels M, Nevens D, Billiet C, Poortmans P, Gevaert T, Verellen D. Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry. Phys Imaging Radiat Oncol 2022; 22:85-90. [PMID: 35602547 PMCID: PMC9117915 DOI: 10.1016/j.phro.2022.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 05/04/2022] [Accepted: 05/05/2022] [Indexed: 11/26/2022] Open
Abstract
Background and purpose Postoperative ultrahypofractionated radiation therapy (UHFRT) in 5 fractions (fx) for breast cancer patients is as effective and safe as conventionally hypofractionated RT (HFRT) in 15 fx, liberating time for higher-level daily online Image-Guided Radiation Therapy (IGRT) corrections. In this retrospective study, treatment uncertainties occurring in patients treated with 5fx (5fx-group) were evaluated using electronic portal imaging device (EPID)-based in-vivo dosimetry (EIVD) and compared with the results from patients treated with conventionally HFRT (15fx-group) to validate the new technique and to evaluate if the shorter treatment schedule could have a positive effect on the treatment uncertainties. Materials and methods EPID-based integrated transit dose images were acquired for each treatment fraction in the 5fx-group (203 patients) and on the first 3 days of treatment and weekly thereafter in the 15fx-group (203 patients). A total of 1015 EIVD measurements in the 5fx-group and 1144 in the 15fx-group were acquired. Of the latter group, 755 had been treated with online IGRT correction (i.e., Online-IGRT 15fx-group). Results In the 15fx-group 12.0% of fractions failed (FFs) compared to 3.8% in the 5fx-group and 6.9% in the online-IGRT 15fx-group. Causes for FFs in the 15fx-group compared with the 5fx-group were patient positioning (7.4% vs. 2.2%), technical issues (3.1% vs. 1.2%) and breast swelling (1.4% vs. 0.5%). In the online-IGRT 15fx-group, 2.5% were attributed to patient positioning, 3.8% to technical issues and 0.5% to breast swelling. Conclusions EIVD demonstrated that UHFRT for breast cancer results in less FFs compared to standard HFRT. A large proportion of this decrease could be explained by using daily online IGRT.
Collapse
|
21
|
Chalise AR, Bojechko C. Using eclipse scripting to fully automate in-vivo image analysis to improve treatment quality and safety. J Appl Clin Med Phys 2022; 23:e13585. [PMID: 35315570 PMCID: PMC9194972 DOI: 10.1002/acm2.13585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 01/13/2022] [Accepted: 02/23/2022] [Indexed: 11/09/2022] Open
Abstract
PURPOSE An automated, in-vivo system to detect patient anatomy changes and machine output was developed using novel analysis of in-vivo electronic portal imaging device (EPID) images for every fraction of treatment on a Varian Halcyon. In-vivo approach identifies errors that go undetected by routine quality assurance (QA) to compliment daily machine performance check (MPC), with minimal physicist workload. METHODS Images for all fractions treated on a Halcyon were automatically downloaded and analyzed at the end of treatment day. For image analysis, compared to first fraction, the mean difference of high-dose region of interest is calculated. This metric has shown to predict changes in planning treatment volume (PTV) mean dose. Flags are raised for: (Type-A) treatment fraction whose mean difference exceeds 10%, to protect against large errors, and (Type-B) patients with three consecutive fractions with mean exceeding ±3%, to protect against systematic trends. If a threshold is exceeded, a physicist is e-mailed, a report for flagged patients, for investigation. To track machine output changes, for all patients treated on a day, the average and standard deviations are uploaded to a QA portal, along with the reviewed MPC, ensuring comprehensive QA for the Halcyon. To guide clinical implementation, a retrospective study from November 2017 till December 2020 was conducted, which grouped errors by treatment site. This framework has been used prospectively since January 2021. RESULTS From retrospective data of 1633 patients (35 759 fractions), no Type-A errors were found and only 45 patients (2.76%) had Type-B errors. These Type-B deviations were due to head-and-neck weight loss. For 6 months of prospective use (345 patients), 13 patients (3.7%) had Type-B errors and no Type-A errors. CONCLUSIONS This automated system protects against errors that can occur in vivo to provide a more comprehensive QA. This fully automated framework can be implemented in other centers with a Halcyon, requiring a desktop computer and analysis scripts.
Collapse
Affiliation(s)
- Ananta Raj Chalise
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California, USA
| | - Casey Bojechko
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California, USA
| |
Collapse
|
22
|
Mans A, Rozendaal R, Janssen T, Damen E, Kaas J, van Mourik A, Mijnheer B. Reduction of systematic dosimetric uncertainties in volumetric modulated arc therapy triggered by patient-specific quality assurance. Phys Imaging Radiat Oncol 2022; 21:6-10. [PMID: 35106384 PMCID: PMC8789528 DOI: 10.1016/j.phro.2022.01.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 12/24/2021] [Accepted: 01/07/2022] [Indexed: 10/27/2022] Open
|
23
|
Renaud J, Muir B. Assessing the accuracy of electronic portal imaging device (EPID)-based dosimetry: I. Quantities influencing long-term stability. Med Phys 2021; 49:1231-1237. [PMID: 34964136 DOI: 10.1002/mp.15434] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 12/08/2021] [Accepted: 12/12/2021] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The aim of this study is to reduce the uncertainty associated with determining dose-to-water using an amorphous silicon electronic portal imaging detector (EPID) under reference conditions by identifying and accounting for operational and environmental factors influencing long-term stability of EPID response. METHODS Measurements of the EPID relative response, corrected for variations in linear accelerator (linac) output, were performed regularly over a period of 12 months. For every acquired image set, measurements of detector supply voltages, internal operating temperature, and ambient environmental conditions were obtained. Pearson r correlation coefficients were then calculated for each pair of variables, a subset of which were fitted using multiple linear regression to develop a predictive model of EPID response. Principal component analysis was performed on the dataset to reveal the internal structure of the data in a way that best accounts for the observed variations. RESULTS The +5.5 V power supply voltage, internal operating temperature, and the accumulated dose absorbed in EPID were identified as having the greatest influence on the long-term stability of EPID response. By correcting for the combined effect of these variables, the mean difference in linac output as measured by the EPID relative to a reference-class chamber improved from -0.46 % to 0.23 % over the period of the study. CONCLUSIONS This work suggests that the stability of an EPID over a period of a year can be improved by a factor of two by monitoring and accounting for the effects of variations in power supply voltage, internal temperature of the detector, and accumulated absorbed dose. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- James Renaud
- Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada
| | - Bryan Muir
- Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada
| |
Collapse
|
24
|
Renaud J, Muir B. Assessing the accuracy of electronic portal imaging device (EPID)-based dosimetry: II. Evaluation of a dosimetric uncertainty budget and development of a new film-in-EPID absorbed dose calibration methodology. Med Phys 2021; 49:1238-1247. [PMID: 34954834 DOI: 10.1002/mp.15425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2021] [Accepted: 12/12/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The aim of this study is to reduce the uncertainty associated with determining dose-to-water using an amorphous silicon electronic portal imaging detector (EPID) under reference conditions by developing a direct calibration formalism based on radiochromic film measurements made within the EPID panel and detailed Monte Carlo simulations. To our knowledge, this is the first EPID-based dosimetry study reporting an uncertainty budget . METHODS Pixel sensitivity and relative off-axis response was mapped by simultaneously irradiating film contained within the imager panel and acquiring an EPID image set. The detector panel was disassembled for the purpose of modeling the EPID in detail using the EGSnrc DOSXYZnrc usercode, which was in turn used to calculate dose-to-film in EPID to dose-to-water in water conversion factors . RESULTS A direct comparison of the two correction methodologies investigated in this work, the previously established empirical method and the proposed simultaneous measurement approach involving in-EPID film dosimetry, produced an agreement with an RMS deviation of 1.4 % overall. A combined standard relative uncertainty of 3.3 % (k = 1) was estimated for the determination of absorbed dose to water at the position of the EPID using the proposed calibration methodology . CONCLUSIONS This work describes a direct method of calibrating EPID response in terms of absorbed dose to water requiring fewer measurements than other empirical approaches, and without 2D spatial interpolation of correction factors. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- James Renaud
- Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada
| | - Bryan Muir
- Metrology Research Centre, National Research Council Canada, Ottawa, Ontario, Canada
| |
Collapse
|
25
|
Calvo‐Ortega J, Greer PB, Hermida‐López M, Moragues‐Femenía S, Laosa‐Bello C, Casals‐Farran J. Validation of virtual water phantom software for pre-treatment verification of single-isocenter multiple-target stereotactic radiosurgery. J Appl Clin Med Phys 2021; 22:241-252. [PMID: 34028955 PMCID: PMC8200437 DOI: 10.1002/acm2.13269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 02/05/2021] [Accepted: 04/13/2021] [Indexed: 11/09/2022] Open
Abstract
The aim of this study was to benchmark the accuracy of the VIrtual Phantom Epid dose Reconstruction (VIPER) software for pre-treatment dosimetric verification of multiple-target stereotactic radiosurgery (SRS). VIPER is an EPID-based method to reconstruct a 3D dose distribution in a virtual phantom from in-air portal images. Validation of the VIPER dose calculation was assessed using several MLC-defined fields for a 6 MV photon beam. Central axis percent depth doses (PDDs) and output factors were measured with an ionization chamber in a water tank, while dose planes at a depth of 10 cm in a solid flat phantom were acquired with radiochromic films. The accuracy of VIPER for multiple-target SRS plan verification was benchmarked against Monte Carlo simulations. Eighteen multiple-target SRS plans designed with the Eclipse treatment planning system were mapped to a cylindrical water phantom. For each plan, the 3D dose distribution reconstructed by VIPER within the phantom was compared with the Monte Carlo simulation, using a 3D gamma analysis. Dose differences (VIPER vs. measurements) generally within 2% were found for the MLC-defined fields, while film dosimetry revealed gamma passing rates (GPRs) ≥95% for a 3%/1 mm criteria. For the 18 multiple-target SRS plans, average 3D GPRs greater than 93% and 98% for the 3%/2 mm and 5%/2 mm criteria, respectively. Our results validate the use of VIPER as a dosimetric verification tool for pre-treatment QA of single-isocenter multiple-target SRS plans. The method requires no setup time on the linac and results in an accurate 3D characterization of the delivered dose.
Collapse
Affiliation(s)
- Juan‐Francisco Calvo‐Ortega
- Servicio de Oncología RadioterápicaHospital QuirónsaludBarcelonaSpain
- Servicio de Oncología RadioterápicaHospital Universitari DexeusBarcelonaSpain
| | - Peter B. Greer
- Department of Radiation OncologyCalvary Mater Newcastle HospitalNewcastleNSW2298Australia
- School of Mathematical and Physical SciencesUniversity of NewcastleNewcastleNSW2300Australia
| | | | - Sandra Moragues‐Femenía
- Servicio de Oncología RadioterápicaHospital QuirónsaludBarcelonaSpain
- Servicio de Oncología RadioterápicaHospital Universitari DexeusBarcelonaSpain
| | - Coral Laosa‐Bello
- Servicio de Oncología RadioterápicaHospital QuirónsaludBarcelonaSpain
- Servicio de Oncología RadioterápicaHospital Universitari DexeusBarcelonaSpain
| | - Joan Casals‐Farran
- Servicio de Oncología RadioterápicaHospital QuirónsaludBarcelonaSpain
- Servicio de Oncología RadioterápicaHospital Universitari DexeusBarcelonaSpain
| |
Collapse
|
26
|
Corradini S, Niyazi M, Verellen D, Valentini V, Walsh S, Grosu AL, Lauber K, Giaccia A, Unger K, Debus J, Pieters BR, Guckenberger M, Senan S, Budach W, Rad R, Mayerle J, Belka C. X-change symposium: status and future of modern radiation oncology-from technology to biology. Radiat Oncol 2021; 16:27. [PMID: 33541387 PMCID: PMC7863262 DOI: 10.1186/s13014-021-01758-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 01/28/2021] [Indexed: 02/06/2023] Open
Abstract
Future radiation oncology encompasses a broad spectrum of topics ranging from modern clinical trial design to treatment and imaging technology and biology. In more detail, the application of hybrid MRI devices in modern image-guided radiotherapy; the emerging field of radiomics; the role of molecular imaging using positron emission tomography and its integration into clinical routine; radiation biology with its future perspectives, the role of molecular signatures in prognostic modelling; as well as special treatment modalities such as brachytherapy or proton beam therapy are areas of rapid development. More clinically, radiation oncology will certainly find an important role in the management of oligometastasis. The treatment spectrum will also be widened by the rational integration of modern systemic targeted or immune therapies into multimodal treatment strategies. All these developments will require a concise rethinking of clinical trial design. This article reviews the current status and the potential developments in the field of radiation oncology as discussed by a panel of European and international experts sharing their vision during the "X-Change" symposium, held in July 2019 in Munich (Germany).
Collapse
Affiliation(s)
- Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Dirk Verellen
- Department of Radiotherapy, Iridium Network, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Vincenzo Valentini
- Department of Radiation Oncology and Hematology, Fondazione Policlinico Universitario A.Gemelli IRCCS, Università Cattolica S. Cuore, Rome, Italy
| | | | - Anca-L Grosu
- Department of Radiation Oncology, Medical Center, Medical Faculty, University of Freiburg, Freiburg, Germany
- German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany
| | - Kirsten Lauber
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| | - Amato Giaccia
- Division of Radiation and Cancer Biology, Department of Radiation Oncology, Stanford University, Stanford, USA
| | - Kristian Unger
- Integrative Biology Group, Helmholtz Zentrum Munich, Munich, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Bradley R Pieters
- Department of Radiation Oncology, Amsterdam University Medical Centers, Location Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland
| | - Suresh Senan
- Department of Radiation Oncology, Amsterdam University Medical Centers, Location VUmc, Amsterdam, The Netherlands
| | - Wilfried Budach
- Department of Radiation Oncology, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany
| | - Roland Rad
- Center for Translational Cancer Research (TranslaTUM), TU Munich, Munich, Germany
| | - Julia Mayerle
- Department of Internal Medicine II, University Hospital, LMU, Munich, Germany
| | - Claus Belka
- Department of Radiation Oncology, University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany
| |
Collapse
|
27
|
Fiagan YA, Bossuyt E, Nevens D, Dirix P, Theys F, Gevaert T, Verellen D. In vivo dosimetry for patients with prostate cancer to assess possible impact of bladder and rectum preparation. Tech Innov Patient Support Radiat Oncol 2020; 16:65-69. [PMID: 33294646 PMCID: PMC7701258 DOI: 10.1016/j.tipsro.2020.10.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/28/2020] [Accepted: 10/29/2020] [Indexed: 11/19/2022] Open
Abstract
PURPOSE/OBJECTIVE In all treatment sites of our radiotherapy network, in vivo dosimetry (PerFRACTION™) was fully implemented in February 2018. We hypothesized that additional help with bladder and rectum preparation by home nursing would improve patients' preparation and investigated if this could be assessed using in vivo dosimetry (IVD). MATERIALS/METHODS A retrospective study was conducted with a test group who received additional help with bladder and rectum preparation by home nurses and a control group who only received information on bladder and rectum preparation according to the standard protocol. Patients were treated with a 6 MV Volumetric Modulated Arc Therapy (VMAT) technique. Electronic portal imaging device (EPID)-based integrated transit dose images were acquired on the first 3 days of treatment and weekly thereafter or more if failed fractions (FF) occurred. Results were analyzed using a global gamma analysis with a threshold of 20%, tolerance of 5% (dose difference) and 5 mm (distance to agreement), and a passing level of 95%. RESULTS Data of 462 prostate patients was analyzed: 39 and 423 in a test and control group respectively with a comparable number of measurements (on average 8.0 (σ = 4.8) and 7.1 (σ = 4.5) respectively per treatment course). Of the FF, 39% and 31% were related to variations in bladder and rectum filling for the test and control group respectively. Subgroups were created based on the number of FF, no statistically significant differences were observed. CONCLUSION Two dimensional EPID-based IVD successfully detected deviations due to variations in bladder and rectum filling, however it could not confirm the hypothesis.
Collapse
Affiliation(s)
- Yawo A.C. Fiagan
- Iridium Netwerk, Radiation Oncology Department, Universiteit Antwerpen, Antwerp, Belgium
- Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium
| | - Evy Bossuyt
- Iridium Netwerk, Radiation Oncology Department, Universiteit Antwerpen, Antwerp, Belgium
| | - Daan Nevens
- Iridium Netwerk, Radiation Oncology Department, Universiteit Antwerpen, Antwerp, Belgium
- Faculty of Medicine and Health Sciences, Universiteit Antwerpen, Antwerp, Belgium
| | - Piet Dirix
- Iridium Netwerk, Radiation Oncology Department, Universiteit Antwerpen, Antwerp, Belgium
- Faculty of Medicine and Health Sciences, Universiteit Antwerpen, Antwerp, Belgium
| | - Frank Theys
- Iridium Netwerk, Radiation Oncology Department, Universiteit Antwerpen, Antwerp, Belgium
| | - Thierry Gevaert
- Faculty of Medicine and Pharmacy, Vrije Universiteit Brussel, Brussels, Belgium
| | - Dirk Verellen
- Iridium Netwerk, Radiation Oncology Department, Universiteit Antwerpen, Antwerp, Belgium
- Faculty of Medicine and Health Sciences, Universiteit Antwerpen, Antwerp, Belgium
| |
Collapse
|