1
|
Kaketaka T, Mineo I, Kimura Y, Ito N, Okauchi Y, Tamura H, Adachi S, Iwahashi H. Insulinoma with Hyperprocalcitoninemia and Hypercalcitoninemia Showing Coexpression of Insulin and Calcitonin in Its Tumor Cells. Intern Med 2024; 63:1415-1420. [PMID: 37839887 PMCID: PMC11157324 DOI: 10.2169/internalmedicine.1565-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 08/28/2023] [Indexed: 10/17/2023] Open
Abstract
Neuroendocrine neoplasms can produce multiple hormones that are released into the bloodstream, causing symptoms that vary depending on the type and quantity of hormones involved. We herein report a 63-year-old asymptomatic patient with pancreatic insulinoma who showed marked elevations in circulating calcitonin and procalcitonin levels that returned to normal following surgery. Immunohistochemical analyses confirmed the co-staining of calcitonin and insulin immunoreactivity in the tumor cells, suggesting a calcitonin-producing insulinoma. This insulinoma released calcitonin and a considerable amount of its precursor peptide, procalcitonin, resulting in both hyperprocalcitoninemia and hypercalcitoninemia.
Collapse
Affiliation(s)
| | - Ikuo Mineo
- Diabetes Center, Toyonaka Municipal Hospital, Japan
| | - Yu Kimura
- Diabetes Center, Toyonaka Municipal Hospital, Japan
| | - Naohiko Ito
- Diabetes Center, Toyonaka Municipal Hospital, Japan
| | | | - Hiromi Tamura
- Department of Pathology, Toyonaka Municipal Hospital, Japan
| | - Shiro Adachi
- Department of Pathology, Toyonaka Municipal Hospital, Japan
| | | |
Collapse
|
2
|
Nakagawa M, Tomioka Y, Akuta T. Efficient expression and purification of tag-free recombinant human procalcitonin (hPCT) with precise sequence in E.coli. Protein Expr Purif 2024; 214:106374. [PMID: 37793478 DOI: 10.1016/j.pep.2023.106374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 09/15/2023] [Accepted: 09/23/2023] [Indexed: 10/06/2023]
Abstract
We present an efficient method for expression and purification of recombinant human procalcitonin (hPCT) in E. coli T7 express LysY/Iq cells, ensuring precise N- and C-terminal amino acid sequences. Our method involves fusing codon-optimized cDNA with two distinct tag sequences: eXact tag and chitin binding domain (CBD) tag. To purify the protein, we employ a two-step affinity chromatography process. Firstly, we utilize the N-terminal Profinity eXact tag and purify the protein through Profinity eXact-affinity column chromatography using a resin on which a mutant subtilisin protease was immobilized. The eXact tag was removed by adding NaF to activate the enzyme. Subsequently, the digested sample containing C-terminal CBD tag is directly loaded for the second step of chitin affinity chromatography. Elution is achieved through dithiothreitol (DTT)-catalyzed self-cleavage of the intein sequence from the fusion protein. As a result, the target protein is selectively recovered in the flow-through, completely tag-free, with a purity exceeding 95%. To ensure high purity and eliminate potential contaminants, we effectively remove E. coli host DNA and endotoxins through a combination of streptomycin sulfate, Triton X-114, and ammonium sulfate treatment. The exceptional level of purity obtained eliminates the need for further purification steps in most applications. This highly purified hPCT can be used as a calibrator in procalcitonin or calcitonin immunoassays. Notably, our approach effectively manages small peptides that are prone to degradation by E. coli host proteases, offering a robust solution for various research and application requirements.
Collapse
Affiliation(s)
- Masataka Nakagawa
- Research and Development Division, Kyokuto Pharmaceutical Industrial Co., Ltd., 3333-26, Aza-Asayama, Kamitezuna Takahagi-shi, Ibaraki, 318-0004, Japan
| | - Yui Tomioka
- Research and Development Division, Kyokuto Pharmaceutical Industrial Co., Ltd., 3333-26, Aza-Asayama, Kamitezuna Takahagi-shi, Ibaraki, 318-0004, Japan
| | - Teruo Akuta
- Research and Development Division, Kyokuto Pharmaceutical Industrial Co., Ltd., 3333-26, Aza-Asayama, Kamitezuna Takahagi-shi, Ibaraki, 318-0004, Japan.
| |
Collapse
|
3
|
Tölke SA, Masetto T, Reuschel T, Grimmler M, Bindila L, Schneider K. Immunoaffinity LC-MS/MS Quantification of the Sepsis Biomarker Procalcitonin Using Magnetic- and Polystyrene-Bead Immobilized Polyclonal Antibodies. J Proteome Res 2023; 22:3135-3148. [PMID: 37672672 DOI: 10.1021/acs.jproteome.3c00082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
Procalcitonin (PCT) is a biomarker for bacterial sepsis, and accurate quantification of PCT is critical for sepsis diagnosis and treatment. Immunological PCT quantification methods are routinely used in clinical laboratories, yet there is a need for harmonization of PCT quantification protocols. An orthogonal method to clinical immunological assays, such as LC-MS/MS, is required. In this study, a highly sensitive and robust immunoaffinity LC-MRM quantitative method for detecting procalcitonin in human serum has been developed. An initial comparison of immunocapture of PCT with a polyclonal anti-PCT antibody immobilized on polystyrene nanoparticles (Latex) and magnetic beads demonstrated superior performance with magnetic beads. Three tryptic PCT peptides from the N- and C-terminal regions of PCT were selected for LC-MS/MS quantification. For PCT quantification, an LLOQ of 0.25 ng/mL of PCT in human serum was achieved using a sample volume of 1 mL. The method's trueness and precision consistently lie within the 15% margin. The parallel measurement of three PCT peptides may allow future differentiation of intact PCT vs other PCT forms originating from potential degradation, processing, or polymorphisms. An established and validated LC-MRM-based quantification of PCT will be relevant as an orthogonal method for harmonization and standardization of clinical assays for PCT.
Collapse
Affiliation(s)
- Sebastian-Alexander Tölke
- Institute for Biomolecular Research, Hochschule Fresenius, University of Applied Sciences, Limburger Straße 2, 65510 Idstein, Germany
- Clinical Lipidomics Unit, Institute of Physiological Chemistry, University Medical Center, 55131 Mainz, Germany
| | - Thomas Masetto
- Institute of Molecular Medicine I, Medical Faculty,, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany
- DiaSys Diagnostic Systems GmbH, Alte Straße 9, 65558 Holzheim, Germany
| | - Thomas Reuschel
- Institute for Biomolecular Research, Hochschule Fresenius, University of Applied Sciences, Limburger Straße 2, 65510 Idstein, Germany
| | - Matthias Grimmler
- Institute for Biomolecular Research, Hochschule Fresenius, University of Applied Sciences, Limburger Straße 2, 65510 Idstein, Germany
- DiaSys Diagnostic Systems GmbH, Alte Straße 9, 65558 Holzheim, Germany
- DiaServe Laboratories GmbH, Seeshaupter Straße 27, 82393 Iffeldorf, Germany
| | - Laura Bindila
- Clinical Lipidomics Unit, Institute of Physiological Chemistry, University Medical Center, 55131 Mainz, Germany
| | - Klaus Schneider
- Institute for Biomolecular Research, Hochschule Fresenius, University of Applied Sciences, Limburger Straße 2, 65510 Idstein, Germany
| |
Collapse
|
4
|
Huynh HH, Delatour V, Derbez-Morin M, Liu Q, Boeuf A, Vinh J. Candidate High-Resolution Mass Spectrometry-Based Reference Method for the Quantification of Procalcitonin in Human Serum Using a Characterized Recombinant Protein as a Primary Calibrator. Anal Chem 2022; 94:4146-4154. [PMID: 35235744 PMCID: PMC8928150 DOI: 10.1021/acs.analchem.1c03061] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
![]()
Procalcitonin
(PCT) is a widely used biomarker for rapid sepsis
diagnosis and antibiotic stewardship. Variability of results in commercial
assays has highlighted the need for standardization of PCT measurements.
An antibody-free candidate reference measurement procedure (RMP) based
on the isotope dilution mass spectrometry and protein calibration
approach was developed and validated to quantify PCT in human serum.
The method allows quantification of PCT from 0.25 to 13.74 μg/L
(R > 0.998) with extension up to 132 μg/L
after
dilution of samples with PCT concentration above 13.74 μg/L.
Intraday bias was between −3.3 and +5.7%, and interday bias
was between −3.0 and −0.7%. Intraday precision was below
5.1%, and interday precision was below 4.0%. The candidate RMP was
successfully applied to the absolute quantification of PCT in five
frozen human serum pools. A recombinant PCT used as a primary calibrator
was characterized by high-resolution mass spectrometry and amino acid
analysis to establish traceability of the results to the SI units.
This candidate RMP is fit to assign target values to secondary certified
reference materials (CRMs) for further use in external quality assessment
schemes to monitor the accuracy and comparability of the commercially
available immunoassay results and to confirm the need for improving
the harmonization of PCT assays. The candidate RMP will also be used
to evaluate whether the correlation between the candidate RMP and
immunoassays is sufficiently high. Overall, this candidate RMP will
support reliable sepsis diagnosis and guide treatment decisions, patient
monitoring, and outcomes.
Collapse
Affiliation(s)
- Huu-Hien Huynh
- Department of Biomedical and Organic Chemistry, Laboratoire National de Métrologie et d'Essais (LNE), 75724 Paris, France.,Biological Mass Spectrometry and Proteomics, SMBP, PDC UMR 8249 CNRS, ESPCI Paris, Université PSL, 75005 Paris, France
| | - Vincent Delatour
- Department of Biomedical and Organic Chemistry, Laboratoire National de Métrologie et d'Essais (LNE), 75724 Paris, France
| | - Maxence Derbez-Morin
- Department of Biomedical and Organic Chemistry, Laboratoire National de Métrologie et d'Essais (LNE), 75724 Paris, France.,CEA, INRAE, Département Médicaments et Technologies pour la Santé (DMTS), SPI, Université Paris-Saclay, 91191 Gif-sur-Yvette, France
| | - Qinde Liu
- Chemical Metrology Division, Applied Sciences Group, Health Sciences Authority, 117528 Singapore
| | - Amandine Boeuf
- Department of Biomedical and Organic Chemistry, Laboratoire National de Métrologie et d'Essais (LNE), 75724 Paris, France
| | - Joëlle Vinh
- Biological Mass Spectrometry and Proteomics, SMBP, PDC UMR 8249 CNRS, ESPCI Paris, Université PSL, 75005 Paris, France
| |
Collapse
|
5
|
Huynh HH, Bœuf A, Pfannkuche J, Schuetz P, Thelen M, Nordin G, van der Hagen E, Kaiser P, Kesseler D, Badrick T, Poggi B, Tiikkainen U, Davies GJ, Kessler A, Plebani M, Vinh J, Delatour V. Harmonization status of procalcitonin measurements: what do comparison studies and EQA schemes tell us? Clin Chem Lab Med 2021; 59:1610-1622. [PMID: 34147043 DOI: 10.1515/cclm-2021-0566] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 06/09/2021] [Indexed: 11/15/2022]
Abstract
Sepsis represents a global health priority because of its high mortality and morbidity. The key to improving prognosis remains an early diagnosis to initiate appropriate antibiotic treatment. Procalcitonin (PCT) is a recognized biomarker for the early indication of bacterial infections and a valuable tool to guide and individualize antibiotic treatment. To meet the increasing demand for PCT testing, numerous PCT immunoassays have been developed and commercialized, but results have been questioned. Many comparison studies have been carried out to evaluate analytical performance and comparability of results provided by the different commercially available immunoassays for PCT, but results are conflicting. External Quality Assessment Schemes (EQAS) for PCT constitute another way to evaluate results comparability. However, when making this comparison, it must be taken into account that the variety of EQA materials consist of different matrices, the commutability of which has not yet been investigated. The present study gathers results from all published comparison studies and results from 137 EQAS surveys to describe the current state-of-the-art harmonization of PCT results. Comparison studies globally highlight a significant variability of measurement results that nonetheless seem to have a moderate impact on medical decision-making. For their part, EQAS for PCT provides highly discrepant estimates of the interlaboratory CV. Due to differences in commutability of the EQA materials, the results from different peer groups could not be compared. To improve the informative value of the EQA data, the existing limitations such as non-harmonized conditions and suboptimal and/or unknown commutability of the EQA materials have to be overcome. The study highlights the need for commutable reference materials that could be used to properly evaluate result comparability and possibly standardize calibration, if necessary. Such an initiative would further improve the safe use of PCT in clinical routine.
Collapse
Affiliation(s)
- Huu-Hien Huynh
- Laboratoire National de Métrologie et d'Essais, Paris, France
- Biological Mass Spectrometry and Proteomics, SMBP, ESPCI Paris, Université PSL, CNRS, Paris, France
| | - Amandine Bœuf
- Laboratoire National de Métrologie et d'Essais, Paris, France
| | | | - Philipp Schuetz
- University Department of Medicine, Kantonsspital Aarau, Switzerland
- Faculty of medicine, University of Basel, Basel, Switzerland
| | - Marc Thelen
- Dutch Foundation for Quality Assessment in Medical Laboratories (SKML), Nijmegen, The Netherlands
| | - Gunnar Nordin
- External Quality Assurance in Laboratory Medicine in Sweden (Equalis), Uppsala, Sweden
| | - Eline van der Hagen
- MCA laboratory, Streekziekenhuis Koningin Beatrix, Winterswijk, The Netherlands
| | | | - Dagmar Kesseler
- Quality Control Center Switzerland (CSCQ), Chêne-Bourg, Switzerland
| | - Tony Badrick
- Royal College of Pathologists of Australasia Quality Assurance Programs (RCPAQAP), Sydney, Australia
| | - Bernard Poggi
- ProBioQual, Lyon, France
- Laboratoire de Biochimie des Hospices Civiles de Lyon, Lyon, France
| | | | - Gareth J Davies
- Weqas, Cardiff and Vale University Health Board, Cardiff, Wales, UK
| | - Anja Kessler
- Reference Institute for Bioanalytics (RfB), Bonn, Germany
| | - Mario Plebani
- Department of Laboratory Medicine, University Hospital of Padova, Verona, Italy
| | - Joëlle Vinh
- Biological Mass Spectrometry and Proteomics, SMBP, ESPCI Paris, Université PSL, CNRS, Paris, France
| | | |
Collapse
|
6
|
Huynh HH, Bœuf A, Vinh J, Delatour V. Evaluation of the necessity and the feasibility of the standardization of procalcitonin measurements: Activities of IFCC WG-PCT with involvement of all stakeholders. Clin Chim Acta 2021; 515:111-121. [PMID: 33450213 DOI: 10.1016/j.cca.2021.01.004] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 12/10/2020] [Accepted: 01/06/2021] [Indexed: 12/11/2022]
Abstract
Procalcitonin (PCT) is an important biomarker for sepsis diagnosis and management. To date, there is no higher-order reference measurement procedure (RMP) and certified reference material to achieve global standardization of results and results traceability to the SI units. Although efforts have been made to harmonize PCT results, a number of comparison studies and external quality assessment (EQA) schemes show conflicting results regarding results comparability and to date, equivalence of PCT results across the assays remains questionable in absence of studies relying on commutable EQA materials. In this context, the IFCC initiated activities to fill these gaps through the creation of the working group on standardization of PCT assays that gathers experts from National Metrology Institutes, calibration laboratories, clinicians, biologists, EQA providers and assay manufacturers. Among the activities, a higher order RMP and commutable reference materials are under development to build a robust reference measurement system (RMS). A commutability study is being organized to identify EQA materials that are fit for purpose to reliably estimate the current comparability of PCT results. This work will make it possible to evaluate the necessity and the feasibility for establishing and maintaining a new RMS for PCT assays, if deemed necessary.
Collapse
Affiliation(s)
- Huu-Hien Huynh
- Laboratoire National de Métrologie et d'Essai, Paris, France; Biological Mass Spectrometry and Proteomics, SMBP, ESPCI Paris, Université PSL, CNRS, Paris, France
| | - Amandine Bœuf
- Laboratoire National de Métrologie et d'Essai, Paris, France
| | - Joëlle Vinh
- Biological Mass Spectrometry and Proteomics, SMBP, ESPCI Paris, Université PSL, CNRS, Paris, France
| | | | | |
Collapse
|
7
|
Wang G, Wan Y, Lin G, Li Z, Dong Z, Liu T. Development of a novel chemiluminescence immunoassay for the detection of procalcitonin. J Immunol Methods 2020; 484-485:112829. [PMID: 32673618 DOI: 10.1016/j.jim.2020.112829] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/08/2020] [Accepted: 07/09/2020] [Indexed: 01/28/2023]
Abstract
OBJECTIVE To evaluate the analytical performance of our previously developed chemiluminescence immunoassay (CLIA) kit for the detection of procalcitonin (PCT) and compare with the results obtained using the Vidas B.R.A.H.M.S. PCT™ test (PCT-V). DESIGN AND METHODS Our laboratory previously designed a novel CLIA kit and supporting instrument (AE-180) for the detection of PCT. We analyzed the clinical performance of this system, including the imprecision, limit of detection, and linearity of analyses of 305 serum specimens. The results were compared with measurements of the same serum samples obtained with PCT-V. RESULTS The limit of detection and blank of our kit were 0.0075 and 0.0039 ng/mL, respectively. The intra- and inter-assay coefficient of variation of the kit were both between 0.8% and 3.9%. The equation of linearity was found to be y = 1.03× + 0.06 (r = 0.99) for concentrations in the range of 0.01-110 ng/mL. The correlation coefficient with the results of PCT-V was 0.995, and the equation obtained for Passing and Bablok regression analysis was 1.061 for our CLIA PCT kit and - 0.003 for PCT-V. Our kit slightly overestimated the concentration according to comparison with PCT-V results. CONCLUSION The kit that was previously developed in our laboratory for the measurement of serum PCT concentration using CLIA technology shows excellent performance, just that the functional sensitivity is not as good as the PCT-V; therefore, we suggest that this kit is suitable for clinical use.
Collapse
Affiliation(s)
- Gang Wang
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong, PR China
| | - Yong Wan
- Research Institute, Guangzhou Darui Biotechnology Co., Ltd., Guangzhou 510507, Guangdong, PR China
| | - Guanfeng Lin
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong, PR China
| | - Zhixiong Li
- Research Institute, Guangzhou Darui Biotechnology Co., Ltd., Guangzhou 510507, Guangdong, PR China
| | - Zhining Dong
- Research Institute, Guangzhou Darui Biotechnology Co., Ltd., Guangzhou 510507, Guangdong, PR China
| | - Tiancai Liu
- Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong, PR China; Guangdong Provincial Key Laboratory of Construction and Detection in Tissue Engineering, Southern Medical University, Guangzhou 510515, Guangdong, PR China.
| |
Collapse
|
8
|
Lippi G, Salvagno GL, Gelati M, Pucci M, Demonte D, Faggian D, Plebani M. Analytical Evaluation of the New Beckman Coulter Access Procalcitonin (PCT) Chemiluminescent Immunoassay. Diagnostics (Basel) 2020; 10:diagnostics10030128. [PMID: 32111028 PMCID: PMC7151122 DOI: 10.3390/diagnostics10030128] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2019] [Revised: 02/01/2020] [Accepted: 02/25/2020] [Indexed: 12/21/2022] Open
Abstract
This study was designed to evaluate the analytical performance of the recently commercialized Beckman Coulter Access procalcitonin (PCT) chemiluminescent test on the Access immunoassay system. The analytical assessment encompassed the estimation of limit of blank (LoB), limit of detection (LoD), functional sensitivity (i.e., PCT value with ≤10% imprecision), linearity, imprecision and comparability of values with BRAHMS PCT-sensitive Kryptor. LoB, LoD and functional sensitivity were 0.002 μg/L, 0.003 μg/L and 0.003 μg/L, respectively. Intra-assay, inter-assay and total imprecision for plasma pools with low, medium and high PCT values were 1.8–2.1%, 2.4–3.7% and 3.1–4.3%, respectively. The assay exhibited excellent linearity between 0.02 and 84.0 μg/L. Excellent correlation (r = 0.999; p < 0.001) and negligible bias (3.2%) were found by comparing values obtained in paired plasma samples with BRAHMS PCT-sensitive Kryptor. Diagnostic agreement at 0.5, 2.0 and 10 μg/L PCT values ranged between 98%-100%. The results of this study confirm that Access PCT displays excellent analytical performance and high comparability with BRAHMS PCT-sensitive Kryptor.
Collapse
Affiliation(s)
- Giuseppe Lippi
- Section of Clinical Biochemistry, University of Verona, 37134 Verona, Italy; (G.L.); (M.G.); (M.P.); (D.D.)
| | - Gian Luca Salvagno
- Section of Clinical Biochemistry, University of Verona, 37134 Verona, Italy; (G.L.); (M.G.); (M.P.); (D.D.)
- Correspondence:
| | - Matteo Gelati
- Section of Clinical Biochemistry, University of Verona, 37134 Verona, Italy; (G.L.); (M.G.); (M.P.); (D.D.)
| | - Mairi Pucci
- Section of Clinical Biochemistry, University of Verona, 37134 Verona, Italy; (G.L.); (M.G.); (M.P.); (D.D.)
| | - Davide Demonte
- Section of Clinical Biochemistry, University of Verona, 37134 Verona, Italy; (G.L.); (M.G.); (M.P.); (D.D.)
| | - Diego Faggian
- Department of Laboratory Medicine, University Hospital of Padova, 35128 Padova, Italy; (D.F.); (M.P.)
| | - Mario Plebani
- Department of Laboratory Medicine, University Hospital of Padova, 35128 Padova, Italy; (D.F.); (M.P.)
| |
Collapse
|