1
|
Lathouwers E, Díaz MA, Maricot A, Tassignon B, Cherelle C, Cherelle P, Meeusen R, De Pauw K. Therapeutic benefits of lower limb prostheses: a systematic review. J Neuroeng Rehabil 2023; 20:4. [PMID: 36639655 PMCID: PMC9840272 DOI: 10.1186/s12984-023-01128-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Accepted: 01/07/2023] [Indexed: 01/15/2023] Open
Abstract
BACKGROUND Enhancing the quality of life of people with a lower limb amputation is critical in prosthetic development and rehabilitation. Yet, no overview is available concerning the impact of passive, quasi-passive and active ankle-foot prostheses on quality of life. OBJECTIVE To systematically review the therapeutic benefits of performing daily activities with passive, quasi-passive and active ankle-foot prostheses in people with a lower limb amputation. METHODS We searched the Pubmed, Web of Science, Scopus and Pedro databases, and backward citations until November 3, 2021. Only English-written randomised controlled trials, cross-sectional, cross-over and cohort studies were included when the population comprised individuals with a unilateral transfemoral or transtibial amputation, wearing passive, quasi-passive or active ankle-foot prostheses. The intervention and outcome measures had to include any aspect of quality of life assessed while performing daily activities. We synthesised the participants' characteristics, type of prosthesis, intervention, outcome and main results, and conducted risk of bias assessment using the Cochrane risk of bias tool. This study is registered on PROSPERO, number CRD42021290189. RESULTS We identified 4281 records and included 34 studies in total. Results indicate that quasi-passive and active prostheses are favoured over passive prostheses based on biomechanical, physiological, performance and subjective measures in the short-term. All studies had a moderate or high risk of bias. CONCLUSION Compared to passive ankle-foot prostheses, quasi-passive and active prostheses significantly enhance the quality of life. Future research should investigate the long-term therapeutic benefits of prosthetics devices.
Collapse
Affiliation(s)
- Elke Lathouwers
- grid.8767.e0000 0001 2290 8069Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050 Brussels, Belgium ,grid.8767.e0000 0001 2290 8069Brussels Human Robotics Research Center (BruBotics), Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | - María Alejandra Díaz
- grid.8767.e0000 0001 2290 8069Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050 Brussels, Belgium ,grid.8767.e0000 0001 2290 8069Brussels Human Robotics Research Center (BruBotics), Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | - Alexandre Maricot
- grid.8767.e0000 0001 2290 8069Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | - Bruno Tassignon
- grid.8767.e0000 0001 2290 8069Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | | | | | - Romain Meeusen
- grid.8767.e0000 0001 2290 8069Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050 Brussels, Belgium ,grid.8767.e0000 0001 2290 8069Brussels Human Robotics Research Center (BruBotics), Vrije Universiteit Brussel, 1050 Brussels, Belgium
| | - Kevin De Pauw
- Human Physiology and Sports Physiotherapy Research Group, Vrije Universiteit Brussel, 1050, Brussels, Belgium. .,Brussels Human Robotics Research Center (BruBotics), Vrije Universiteit Brussel, 1050, Brussels, Belgium.
| |
Collapse
|
2
|
Tran M, Gabert L, Hood S, Lenzi T. A lightweight robotic leg prosthesis replicating the biomechanics of the knee, ankle, and toe joint. Sci Robot 2022; 7:eabo3996. [PMID: 36417500 PMCID: PMC9894662 DOI: 10.1126/scirobotics.abo3996] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Robotic leg prostheses promise to improve the mobility and quality of life of millions of individuals with lower-limb amputations by imitating the biomechanics of the missing biological leg. Unfortunately, existing powered prostheses are much heavier and bigger and have shorter battery life than conventional passive prostheses, severely limiting their clinical viability and utility in the daily life of amputees. Here, we present a robotic leg prosthesis that replicates the key biomechanical functions of the biological knee, ankle, and toe in the sagittal plane while matching the weight, size, and battery life of conventional microprocessor-controlled prostheses. The powered knee joint uses a unique torque-sensitive mechanism combining the benefits of elastic actuators with that of variable transmissions. A single actuator powers the ankle and toe joints through a compliant, underactuated mechanism. Because the biological toe dissipates energy while the biological ankle injects energy into the gait cycle, this underactuated system regenerates substantial mechanical energy and replicates the key biomechanical functions of the ankle/foot complex during walking. A compact prosthesis frame encloses all mechanical and electrical components for increased robustness and efficiency. Preclinical tests with three individuals with above-knee amputation show that the proposed robotic leg prosthesis allows for common ambulation activities with close to normative kinematics and kinetics. Using an optional passive mode, users can walk on level ground indefinitely without charging the battery, which has not been shown with any other powered or microprocessor-controlled prostheses. A prosthesis with these characteristics has the potential to improve real-world mobility in individuals with above-knee amputation.
Collapse
Affiliation(s)
- Minh Tran
- Department of Mechanical Engineering and Robotics Center, University of Utah, Salt Lake City, UT, USA
| | - Lukas Gabert
- Department of Mechanical Engineering and Robotics Center, University of Utah, Salt Lake City, UT, USA
| | - Sarah Hood
- Department of Mechanical Engineering and Robotics Center, University of Utah, Salt Lake City, UT, USA
| | - Tommaso Lenzi
- Department of Mechanical Engineering and Robotics Center, University of Utah, Salt Lake City, UT, USA
| |
Collapse
|
3
|
Evaluation of an articulated passive ankle-foot prosthesis. Biomed Eng Online 2022; 21:28. [PMID: 35477464 PMCID: PMC9047309 DOI: 10.1186/s12938-022-00997-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Accepted: 04/08/2022] [Indexed: 11/17/2022] Open
Abstract
Background Current ankle prostheses for people with unilateral transtibial amputation (TTA) or transfemoral amputation (TFA) are unable to mimic able-bodied performance during daily activities. A new mechanical ankle–foot prosthesis was developed to further optimise the gait of people with a lower-limb amputation. This study aimed to evaluate the Talaris Demonstrator (TD) during daily activities by means of performance-related, physiological and subjective outcome measures. Materials and methods Forty-two participants completed a protocol assessing performance and functional mobility with their current prosthesis and the TD. The protocol comprised the L-test, 2 min of stair climbing, 2 min of inclined treadmill walking, 6 min of treadmill walking at 3 different speeds in consecutive blocks of 2 min, and a 3-m Backward Walk test (3mBWT). Heart rate was measured during each task, and oxygen uptake was collected during all tasks except for the L-test and 3mBWT. Time of execution was recorded on the L-test and 3mBWT, and the rate of perceived exertion (score = 6–20), fatigue and comfort (score = 0–100) were assessed after each task. Paired sample t-tests and Wilcoxon Signed-rank tests were performed to compare outcomes between prosthetic devices. Benjamini–Hochberg corrections were applied to control for multiple comparisons with a level of significance set at α = 0.05. Results Subjects with a TTA (N = 28) were faster with their current prosthesis compared to the TD on the L-test and 3mBWT (p = 0.005). In participants with a TFA (N = 14), we observed a tendency towards a higher heart rate during the L-test and towards increased comfort during inclined walking, with the TD compared to the participants’ current prosthetic device (0.05 < p < 0.10). Further, no significant results were observed. Conclusion The Talaris Demonstrator is a novel state-of-the-art passive ankle–foot prosthesis for both people with a TTA and TFA. Subjective measures indicate the added value of this device, while overall task performance and intensity of effort do not differ between the Talaris Demonstrator and the current prosthesis. Further investigations unravelling both acute and more prolonged adaptations will be conducted to evaluate the TD more thoroughly.
Collapse
|
4
|
Alleva S, Antonelli MG, Beomonte Zobel P, Durante F. Biomechanical Design and Prototyping of a Powered Ankle-Foot Prosthesis. MATERIALS 2020; 13:ma13245806. [PMID: 33352691 PMCID: PMC7766738 DOI: 10.3390/ma13245806] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 12/11/2020] [Accepted: 12/16/2020] [Indexed: 12/02/2022]
Abstract
Powered ankle-foot prostheses for walking often have limitations in the range of motion and in push-off power, if compared to a lower limb of a healthy person. A new design of a powered ankle-foot prosthesis is proposed to obtain a wide range of motion and an adequate power for a push-off step. The design methodology for this prosthesis has three points. In the first one, a dimensionless kinematic model of the lower limb in the sagittal plane is built, through an experimental campaign with healthy subjects, to calculate the angles of lower limb during the gait. In the second point a multibody inverse dynamic model of the lower limb is constructed to calculate the foot-ground contact force, its point of application and the ankle torque too, entering as input data the calculated angles of the lower limb in the previous point. The third point requires, as input of the inverse dynamic model, the first dimensioning data of the ankle-foot prosthesis to obtain the load acting on the components of the prosthesis and the angle torque of the actuator during the gait cycle. Finally, an iteration cycle begins with the inverse dynamic model modifying the ankle torque and angle until these quantities during the gait are as close as possible to the physiological quantities. After the mechanical design and the construction of the prototype of the prosthesis, an experimental methodology was used for preliminary validation of the design. The preliminary tests in the laboratory on the prototype alone show that the range of motion of the ankle angle during the gait is close to a healthy person’s: 27.6° vs. 29°. The pushing force of the distal area of the prototype is 1.000 N, instead of 1.600 N, because a budget reduction forced us to choose components for the prototype with lower performance.
Collapse
|
5
|
Hobusch GM, Döring K, Brånemark R, Windhager R. Advanced techniques in amputation surgery and prosthetic technology in the lower extremity. EFORT Open Rev 2020; 5:724-741. [PMID: 33204516 PMCID: PMC7608512 DOI: 10.1302/2058-5241.5.190070] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Bone-anchored implants give patients with unmanageable stump problems hope for drastic improvements in function and quality of life and are therefore increasingly considered a viable solution for lower-limb amputees and their orthopaedic surgeons, despite high infection rates.Regarding diversity and increasing numbers of implants worldwide, efforts are to be supported to arrange an international bone-anchored implant register to transparently overview pros and cons.Due to few, but high-quality, articles about the beneficial effects of targeted muscle innervation (TMR) and regenerative peripheral nerve interface (RPNI), these surgical techniques ought to be directly transferred into clinical protocols, observations and routines.Bionics of the lower extremity is an emerging cutting-edge technology. The main goal lies in the reduction of recognition and classification errors in changes of ambulant modes. Agonist-antagonist myoneuronal interfaces may be a most promising start in controlling of actively powered ankle joints.As advanced amputation surgical techniques are becoming part of clinical routine, the development of financing strategies besides medical strategies ought to be boosted, leading to cutting-edge technology at an affordable price.Microprocessor-controlled components are broadly available, and amputees do see benefits. Devices from different manufacturers differ in gait kinematics with huge inter-individual varieties between amputees that cannot be explained by age. Active microprocessor-controlled knees/ankles (A-MPK/As) might succeed in uneven ground-walking. Patients ought to be supported to receive appropriate prosthetic components to reach their everyday goals in a desirable way.Increased funding of research in the field of prosthetic technology could enhance more high-quality research in order to generate a high level of evidence and to identify individuals who can profit most from microprocessor-controlled prosthetic components. Cite this article: EFORT Open Rev 2020;5:724-741. DOI: 10.1302/2058-5241.5.190070.
Collapse
Affiliation(s)
- Gerhard M Hobusch
- Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna, Austria
| | - Kevin Döring
- Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna, Austria
| | - Rickard Brånemark
- Gothenburg University, Gothenburg, Sweden.,Biomechatronics Group, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | - Reinhard Windhager
- Medical University of Vienna, Department of Orthopaedics and Trauma Surgery, Vienna, Austria
| |
Collapse
|
6
|
Müller R, Tronicke L, Abel R, Lechler K. Prosthetic push-off power in trans-tibial amputee level ground walking: A systematic review. PLoS One 2019; 14:e0225032. [PMID: 31743353 PMCID: PMC6863538 DOI: 10.1371/journal.pone.0225032] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Accepted: 10/09/2019] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVE Unilateral trans-tibial amputation signifies a challenge to locomotion. Prosthetic ankle-foot units are developed to mimic the missing biological system which adapts push-off power to walking speed in some new prosthetic ankle-foot designs. The first systematic review including the two factors aims to investigate push-off power differences among Solid Ankle Cushion Heel (SACH), Energy Storage And Return (ESAR) and Powered ankle-foot units (PWR) and their relation to walking speed. DATA SOURCES A literature search was undertaken in the Web of Science, PubMed, IEEE xplore, and Google Scholar databases. The search term included: ampu* AND prosth* AND ankle-power AND push-off AND walking. STUDY APPRAISAL AND SYNTHESIS METHODS Studies were included if they met the following criteria: unilateral trans-tibial amputees, lower limb prosthesis, reported analysis of ankle power during walking. Data extracted from the included studies were clinical population, type of the prosthetic ankle-foot units (SACH, ESAR, PWR), walking speed, and peak ankle power. Linear regression was used to determine whether the push-off power of different prosthetic ankle-foot units varied regarding walking speed. Push-off power of the different prosthetic ankle-foot units were compared using one-way between subjects' ANOVAs with post hoc analysis, separately for slower and faster walking speeds. RESULTS 474 publications were retrieved, 28 of which were eligible for inclusion. Correlations between walking speed and peak push-off power were found for ESAR (r = 0.568, p = 0.006) and PWR (r = 0.820, p = 0.000) but not for SACH (r = 0.267, p = 0.522). ESAR and PWR demonstrated significant differences in push-off power for slower and faster walking speeds (ESAR (p = 0.01) and PWR (p = 0.02)). CONCLUSION Push-off power can be used as a selection criterion to differentiate ankle-foot units for prosthetic users and their bandwidth of walking speeds.
Collapse
Affiliation(s)
- Roy Müller
- Department of Orthopedic Surgery, Klinikum Bayreuth GmbH, Bayreuth, Germany
- Institute of Sport Sciences, Friedrich Schiller University Jena, Jena, Germany
| | | | - Rainer Abel
- Department of Orthopedic Surgery, Klinikum Bayreuth GmbH, Bayreuth, Germany
| | | |
Collapse
|
7
|
Hope J, Aristovich K, Chapman CAR, Volschenk A, Vanholsbeeck F, McDaid A. Extracting impedance changes from a frequency multiplexed signal during neural activity in sciatic nerve of rat: preliminary study in vitro. Physiol Meas 2019; 40:034006. [DOI: 10.1088/1361-6579/ab0c24] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|