1
|
Miranda JLA, Mesquita RBR, Leite A, Silva AMN, Rangel M, Rangel AOSS. Non-transferrin-bound iron determination in blood serum using microsequential injection solid phase spectrometry- proof of concept. Talanta 2023; 257:124345. [PMID: 36791595 DOI: 10.1016/j.talanta.2023.124345] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 02/07/2023] [Accepted: 02/09/2023] [Indexed: 02/12/2023]
Abstract
Non-transferrin-bound iron (NTBI) is a group of circulating toxic iron forms, which occur in iron overload or health conditions with dysregulation of iron metabolism. NTBI is responsible for increased oxidative stress and tissue iron loading. Despite its relevance as a biochemical marker in several diseases, a standardized assay is still lacking. Several methods were developed to quantify NTBI, but results show high inter-method and even inter-laboratory variability. Thus, the development of a consistent NTBI assay is a major goal in the management of iron overload and related clinical conditions. In this work, a micro sequential injection lab-on-valve (μSI-LOV) method in a solid phase spectrophotometry (SPS) mode was developed for the quantification of NTBI, using a bidentate 3,4-hydroxypyridinone (3,4-HPO) ligand anchored to sepharose beads as a chromogenic reagent. To attain SPS, the functionalized beads were packed into a column in the flow cell, and the analyte, NTBI retained as iron (III), formed a colored complex at the beads while eliminating the sample matrix. The dynamic concentration range was 1.62-7.16 μmol L-1 of iron (III), with a limit of detection of 0.49 μmol L-1 and a limit of quantification of 1.62 μmol L-1. The proposed μSI-LOV-SPS method is a contribution to the development of an automatic method for the quantification of the NTBI in serum samples.
Collapse
Affiliation(s)
- Joana L A Miranda
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho, 1327, 4169-005, Porto, Portugal
| | - Raquel B R Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho, 1327, 4169-005, Porto, Portugal.
| | - Andreia Leite
- REQUIMTE - LAQV, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Rua do Campo Alegre s/n, 4169-007, Porto, Portugal
| | - André M N Silva
- REQUIMTE - LAQV, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Rua do Campo Alegre s/n, 4169-007, Porto, Portugal; REQUIMTE - LAQV, Instituto de Ciências Biomédicas de Abel Salazar, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal
| | - Maria Rangel
- REQUIMTE - LAQV, Instituto de Ciências Biomédicas de Abel Salazar, Universidade do Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal
| | - António O S S Rangel
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho, 1327, 4169-005, Porto, Portugal.
| |
Collapse
|
2
|
Amaral LM, Moniz T, Leite A, Oliveira A, Fernandes P, Ramos MJ, Araújo AN, Freitas M, Fernandes E, Rangel M. A combined experimental and computational study to discover novel tyrosinase inhibitors. J Inorg Biochem 2022; 234:111879. [DOI: 10.1016/j.jinorgbio.2022.111879] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 05/12/2022] [Accepted: 05/27/2022] [Indexed: 11/29/2022]
|
3
|
Tang H, Raymond O, Thomas HP, Henderson W. Synthetic and ESI mass spectrometric investigations of Pt, Pd, Ir, Ru and Rh complexes of a polyether-functionalised thiourea ligand. TRANSIT METAL CHEM 2022. [DOI: 10.1007/s11243-022-00500-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
4
|
Mesquita RBR, Moniz T, Nunes MJM, Mesquita LS, Rangel M, Rangel AOSS. Sequential injection method for bi-parametric determination of iron and manganese in soil leachates. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:180-187. [PMID: 34935789 DOI: 10.1039/d1ay01932e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The aim of this work was to develop a sequential injection (SI) method for the determination of the micronutrients iron and manganese, in soil leachates, as a tool to assess potential groundwater contamination. The described sequential injection method was based on the reaction of iron with chelator MRB12, a greener alternative chromogenic reagent, and the reaction of manganese with zincon, within a single manifold. The developed SI method enabled the determination of iron in the range 0.10-1.00 mg L-1, and manganese in the range 0.25-2.5 mg L-1 with a limit of detection of 0.08 mg L-1 for iron and 0.24 mg L-1 for manganese. The determination of both parameters was made in 6 minutes, in triplicate. The application to monitor laboratory scale soil core columns (LSSCs), as a simulation of the soil leaching process, proved its efficiency to assess potential contamination of ground waters. Iron and manganese contents were effectively analysed in two different scenarios to mimic the leaching process with rainwater and fertilizer.
Collapse
Affiliation(s)
- Raquel B R Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| | - Tânia Moniz
- LAQV, REQUIMTE, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Rua do Campo Alegre, s/n, 4169-007, Porto, Portugal
| | - Maria J M Nunes
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| | - Letícia S Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| | - Maria Rangel
- LAQV, REQUIMTE, Instituto de Ciências Biomédicas de Abel Salazar, Universidade do Porto, Rua Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal
| | - António O S S Rangel
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| |
Collapse
|
5
|
A simple extract of Leucaena leucocephala (Lam.) de Wit leaf containing mimosine as a natural color reagent for iron determination. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105860] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
6
|
Design and synthesis of a new conjugate of a tris(3-hydroxy-4-pyridinone) chelator (KC18) for potential use as gallium-68-labeled prostate-specific membrane antigen (PSMA) radiopharmaceutical. RESULTS IN CHEMISTRY 2021. [DOI: 10.1016/j.rechem.2021.100240] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
|
7
|
Ribas TCF, Mesquita RBR, Moniz T, Rangel M, Rangel AOSS. Greener and wide applicability range flow-based spectrophotometric method for iron determination in fresh and marine water. Talanta 2020; 216:120925. [PMID: 32456899 DOI: 10.1016/j.talanta.2020.120925] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2020] [Revised: 03/09/2020] [Accepted: 03/11/2020] [Indexed: 10/24/2022]
Abstract
A flow-based method for the spectrophotometric determination of iron in recreational waters, both fresh and marine (variable salinity content), was developed. For that purpose, 3-hydroxy-4-pyrydinone ligand functionalized with an ether function was synthetized and used as chromogenic chelator (1-(3'-methoxypropyl)-2-methyl-3-benzyloxy-4-(1H)pyridinone - MRB13) for iron quantification. This water-soluble reagent was previously reported as a greener alternative to quantify iron, due to its low toxicity and a more environmental friendly synthesis. Furthermore, it also displayed a high affinity and specificity for iron. With the main objective of quantifying iron in a variety of water types (different matrices and iron content), two strategies were developed, one of them including on-line solid-phase extraction (SPE), and the other without resorting to a SPE process. Water matrix clean-up and iron enrichment was achieved using a nitrilotriacetic acid resin column. The potential interference of metal ions usually present in water samples was assessed and no significant interference (<10%) was observed. The limits of detection were 11 and 2.9 μg L-1 without and with SPE, respectively. For one determination (three replicates), the corresponding consumption of MRB13 is 90 μg, sodium hydroxide is 1.4 mg, and boric acid is 5.6 mg. The method was applied to certified water samples and the results were in agreement with certified values. The developed method was also applied to fresh and marine water, and recovery ratios of 103 ± 4 and 101 ± 7 without and with SPE, respectively, were achieved.
Collapse
Affiliation(s)
- Tânia C F Ribas
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal
| | - Raquel B R Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal
| | - Tânia Moniz
- REQUIMTE-LAQV, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, 4169-007, Porto, Portugal
| | - Maria Rangel
- REQUIMTE-LAQV, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, 4169-007, Porto, Portugal; REQUIMTE-LAQV, Instituto de Ciências Biomédicas de Abel Salazar, Universidade do Porto, 4050-313, Porto, Portugal
| | - António O S S Rangel
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| |
Collapse
|
8
|
Use of an ether-derived 3-hydroxy-4-pyridinone chelator as a new chromogenic reagent in the development of a microfluidic paper-based analytical device for Fe(III) determination in natural waters. Talanta 2020; 214:120887. [PMID: 32278410 DOI: 10.1016/j.talanta.2020.120887] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 02/27/2020] [Accepted: 02/28/2020] [Indexed: 11/21/2022]
Abstract
This article reports on the development and validation of a disposable microfluidic paper-based analytical device (μPAD) for on-hand, in-situ, and cheap Fe(III) determination in natural waters complying with World Health Organization guidelines. The developed μPAD used 3-hydroxy-4-pyridinone (3,4-HPO) as a colour reagent due to its considerably lower toxicity than traditionally used iron analytical reagents. It was selected among a group of hydrophilic 3,4-HPO chelators containing ether-derived chains in their structure which were prepared using green methods. The relatively high water solubility of these chelators improved the detection limit and applicability as μPAD reagents. Under optimal conditions, the μPAD is characterised by a quantification range between 0.25 and 2.0 mg/L, a detection limit of 55 μg/L and 15 min of analysis time. The signal stability extends up to 4 h and the device is stable for at least one month. The reagent consumption is below 0.2 mg per analysis and the μPAD method was validated by analysis certified reference materials and by comparison with atomic absorption results (RD < 10%). The newly developed μPAD was successfully applied to the determination of iron in river, well and tap waters with no need of any prior sample pre-treatment.
Collapse
|
9
|
Moniz T, Cunha-Silva L, Mesquita RB, Miranda JL, Silva AM, Silva AM, Rangel AO, de Castro B, Rangel M. New hydrophilic 3-hydroxy-4-pyridinone chelators with ether-derived substituents: Synthesis and evaluation of analytical performance in the determination of iron in waters. Polyhedron 2019. [DOI: 10.1016/j.poly.2018.12.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
|
10
|
Miranda JL, Mesquita RB, Nunes A, Rangel M, Rangel AO. Determination of iron(III) in water samples by microsequential injection solid phase spectrometry using an hexadentate 3-hydroxy-4-pyridinone chelator as reagent. Talanta 2019; 191:409-414. [DOI: 10.1016/j.talanta.2018.08.063] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 07/12/2018] [Accepted: 08/24/2018] [Indexed: 10/28/2022]
|
11
|
Study of the effect of thiourea and N-ethyl groups on antibacterial activity of rhodamine-labeled 3,4-HPO iron chelators against Gram (+/−) bacteria. Med Chem Res 2018. [DOI: 10.1007/s00044-018-2165-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
12
|
González A, Mesquita RB, Avivar J, Moniz T, Rangel M, Cerdà V, Rangel AO. Microsequential injection lab-on-valve system for the spectrophotometric bi-parametric determination of iron and copper in natural waters. Talanta 2017; 167:703-708. [DOI: 10.1016/j.talanta.2017.02.055] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 02/22/2017] [Accepted: 02/25/2017] [Indexed: 11/26/2022]
|